Solicitation
VAlve
SLAC_357639_Valve
Department of Energy, SLAC Natl Accel Lab -DOE Contractor. Commercial and Service Industry Machinery Manufacturing.
Response deadline
July 30, 2025 at 8:00 PM EDT
Closed 482 days ago. Posted July 16, 2025, first published July 15, 2025. Scheduled to archive August 14, 2025.
Get the next one like this from Department of Energy by email, the day it is posted.Find my opportunities
This one closed in 2025
60 like it are open now in commercial and service industry machinery manufacturing
- Brand Name Southbend Kettle, Electric, Stationary
Department of the Navy, NAVSUP FLT Log CTR Puget Sound
SolicitationWOSBNAICS 333310Ship to San Diego, CAN0040627Q0037Due in 5 daysNov 30 - Iris aiOne System
Department of Energy, SLAC Natl Accel Lab -DOE Contractor
Combined synopsis and solicitationNAICS 333310Menlo Park, CAReq-369230Due in 6 daysDec 1 - FEEDER,CHEMICAL SOLUTI
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSmall businessNAICS 333310Ship to the buyerSPE8E827Q0069Due tomorrowNov 25
All 60 open in commercial and service industry machinery manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 333310 (commercial and service industry machinery manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 15 days from the day the solicitation was posted, July 15, 2025, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.
The following Addendum is being issued for the subject Request for Quotation: #357639_Valve
- Required item listed Qty revised:
- Item #4:
Flow Safe Spring Op. Relief Valve QTY: 1
P/N S846B-15RF2-02RF2-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 300# RF-ANSI Flange
Outlet: 2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ -321
Functional Test Report, C of C
This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal.
The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same.
---------------------------------------------------------------------------------------------------------------------------------
The follow has been attached for you to complete and review:
- (BAA) Buy American Act Certification
- Representations & Certifications Rider
- Confirm Attached SLAC terms are accepted: FP Commercial Supplies-Services T&Cs (August 2023)
Required item(s) listed below:
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84JE-02RF1-03RF1-SS-SS-TT
Body & Trim: SS
Inlet: 2” 150# RF-ANSI Flange
Outlet: 3” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 70 psig
Process: He gas @ -321
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84FD-15RF1-02RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 150# RF-ANSI Flange
Outlet: 2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: He gas @ -321
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S841M-05RF2-05RF2-SS-SS-TT
Body & Trim: SS
Inlet: 1/2” 300# RF-ANSI Flange
Outlet: 1/2” 300# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: H2 @131
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 2
P/N S846B-15RF2-02RF2-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 300# RF-ANSI Flange
Outlet: 2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ -321
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S848B-01RF2-01RF2-SS-SS-TT
Body & Trim: SS
Inlet: 1” 300# RF-ANSI Flange
Outlet: 1” 300# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ -428
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 2
P/N S846B-15RF1-02RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 150# RF-ANSI Flange
Outlet: 2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: N2 gas @ -268
Functional Test Report, C of C \
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S842M-34RF1-01RF1-SS-SS-TT
Body & Trim: SS
Inlet: 3/4” 150# RF-ANSI Flange
Outlet: 1” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: N2 gas @ -268
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S841M-05RF2-05RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1/2” 300# RF-ANSI Flange
Outlet: 1/2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ 131
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84HE-02RF1-03RF1-SS-SS-TT
Body & Trim: SS
Inlet: 2” 150# RF-ANSI Flange
Outlet: 3” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 75 psig
Process: He gas @ 80
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S844B-34RF1-01RF1-SS-SS-TT
Body & Trim: SS
Inlet: 3/4” 150# RF-ANSI Flange
Outlet: 1” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: He gas @ -442
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84FD-15RF1-03RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 150# RF-ANSI Flange
Outlet: 3” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: He gas @ 80
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84JE-02RF1-03RF1-SS-SS-TT
Body & Trim: SS
Inlet: 2” 150# RF-ANSI Flange
Outlet: 3” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: He gas @ 80
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S843M-05RF2-05RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1/2” 300# RF-ANSI Flange
Outlet: 1/2” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ -442
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84GD-15RF1-03RF1-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” 150# RF-ANSI Flange
Outlet: 3” 150# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 145 psig
Process: He gas @ 80
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S842M-01RF2-01RF2-SS-SS-TT
Body & Trim: SS
Inlet: 1” 300# RF-ANSI Flange
Outlet: 1” 300# RF-ANSI Flange
Seat: Teflon
Seals: Teflon
Set Point: 320 psig
Process: He gas @ -437
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S854B-01MNO-01FNO-SS-SS-VT
Body & Trim: SS
Inlet: 1” MNPT
Outlet: 1” FNPT
Seat: Viton
Seals: Teflon
Set Point: 300 psig
Process: He gas @ 250
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S854B-01RF2-01FNO-SS-SS-VT
Body: SS
Trim: SS
Inlet: 1” 300# RF-ANSI Flange
Outlet: 1” FNPT
Seat: Viton
Seals: Teflon
Set Point: 275 psig
Process: He gas @ 210
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S858B-01RF1-01RF1-SS-SS-VT
Body: SS
Trim: SS
Inlet: 1” 150# RF-ANSI Flange
Outlet: 1” 150# RF-ANSI Flange
Seat: Viton
Seals: Teflon
Set Point: 150 psig
Process: Air @130
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 2
P/N S846B-01FNO-01FNO-SS-SS-TT
Body & Trim: SS
Inlet: 1” FNPT
Outlet: 1” FNPT
Seat: Teflon
Seals: Teflon
Set Point: 75 psig
Process: He gas @ -445
Functional Test Report, C of C
- Flow Safe Spring Op. Relief Valve QTY: 1
P/N S84GD-15FNO-02FNO-SS-SS-TT
Body & Trim: SS
Inlet: 1 1/2” FNPT
Outlet: 2” FNPT
Seat: Teflon
Seals: Teflon
Set Point: 45 psig
Process: He gas @ -447
Functional Test Report, C of C
Quote is for product only; no on-site services permitted.
Source selection will be based on Lowest Price and Technically Acceptable Method (LPTA).
Technical evaluation criteria are as follows:
- Meets specified part numbers exactly (P/N)
- Conforms to requested materials (e.g., Stainless Steel body & trim, Teflon/Viton seats and seals).
- Meets ANSI flange or FNPT inlet/outlet connection specifications.
- Valves must precisely match requested pressure set points (e.g., 70 psig, 145 psig, 320 psig).
- Valves must be suitable for the specified gases and extreme temperature ranges (e.g., Helium at -321°F, Hydrogen at 131°F, Nitrogen at -268°F).
- Includes Functional Test Reports.
Please provide a price and lead time quotation by COB 7/30/2025.
Please be advised that the requirement was also posted on SAM.gov.
Send quote to marissat@SLAC.stanford.edu.
The bid closing date for this requirement is 7/30/2025.
Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?
If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.
- Buy American Act Certification (BAA) applies to awards that are over $10,000.
- Representations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.
- All subcontractors are required to register in the System for Award Management (www.sam.gov).
- The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order.
- Payment Terms will be NET-30 (SLAC is unable to do advance payments and or Prepayments).
- Freight terms will be FOB Destination Prepaid and Add
- Foreign Vendors Shipments will be made CIP SLAC, Menlo Park, and Duty Unpaid.
You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.
Contact me directly with any questions.
Kind regards,
Marissa Tanomrat
Procurement Commodities Team
SLAC National Accelerator Laboratory
2575 Sand Hill Road
Menlo Park, CA 94025
Email: marissat@slac.stanford.edu
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 01. BAA_Certification_08.29.2023_(D5) (1).pdf570 KB, July 15, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 15, 2025
Solicitation
Due July 30, 2025 at 8:00 PM EDT. SAM.gov, notice e1874829602d4cf7b764a8b13a7339ec
2 revisions on SAM
- July 16, 2025: publish, solicitation
- July 15, 2025: publish, solicitation
July 16, 2025
Solicitation
Due July 30, 2025 at 8:00 PM EDT. SAM.gov, notice 2effa695612d4ec88cc667d141ca6b12
2 revisions on SAM
- July 16, 2025: publish, solicitation
- July 15, 2025: publish, solicitation
Points of contact
- Katherine Jill A. Cohkcoh@slac.stanford.edu6509262770