Sources sought, total small business set-aside
Fire Suppression Backflow preventer
PANNGB26P0000038507
Department of the Army, W7M9 Uspfo Activity Ksang 184. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
July 20, 2026 at 10:00 AM EDT
Closed 129 days ago. Posted July 9, 2026. Scheduled to archive August 4, 2026.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2026
59 like it are open now in plumbing, heating, and air-conditioning contractors
- BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031
Department of Veterans Affairs, 262-Network Contract Office 22
Sources soughtSDVOSBNAICS 238220Loma Linda, CA36C26227Q0149Due tomorrowNov 27 - SOURCES SOUGHT NOTICE: Preventive Maintenance Services for Medical Gas and Vacuum Systems
Indian Health Service, Navajo Area Indian Health SVC
Sources soughtNAICS 238220Tonalea, AZIHS1532768Due tomorrowNov 27 - Remediation of storm damage to station multi-Purpose Bldg
US Coast Guard, Base New Orleans
Combined synopsis and solicitationSmall businessNAICS 238220Dauphin Island, AL30332Q270000002Due in 2 daysNov 28
All 59 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. Open Small business opportunities
- What comes next
- No solicitation has been published under this number yet. The sources sought of July 9, 2026 is the earliest notice of the purchase.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.
Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following:
- Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression
- Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.
- Install a new 6-inch diameter Fire Suppression Backflow Prevention System.
- Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
- Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
- Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve
- Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.
- Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.
- Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
- Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
- Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup
- Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System.
- Install a new 1-inch diameter Boiler Makeup Backflow Prevention System.
- Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
- Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
- Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression
- Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System.
- Install a new 4-inch diameter Fire Suppression Backflow Prevention System.
- Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
- Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
- Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water
- Remove the existing 2.5-inch diameter domestic water Backflow Prevention System.
- Install a new 2.5-inch diameter domestic water Backflow Prevention System.
- Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.
- Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:
- Backflow Prevention System’s Installation Date
- Backflow Prevention System’s Manufacture
- Backflow Prevention System’s Model
- Backflow Prevention System’s Serial Number
- Backflow Prevention System’s Rebuild Kit Specifications
- Backflow Prevention System’s Description
For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.
Attachments:
1. Statement of Work
2. Sources Sought Response Form
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Sources Sought Response Form - Fire Suppression Backflow Preventer.pdf156 KB, July 9, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 9, 2026
Sources sought
Due July 20, 2026 at 10:00 AM EDT. SAM.gov, notice 2d64fac728be4aa585ac98144a2b0381
1 revision on SAM
- July 9, 2026: publish, sources sought
Points of contact
- Kevin Smith184wg.msg.contracting@us.af.mil3167597591
- Joshua Kingori184WG.MSG.CONTRACTING@us.af.mil3167597590