# Fire Suppression Backflow preventer

Canonical: https://sealedbidder.com/opportunities/panngb26p0000038507

- Solicitation number: PANNGB26P0000038507
- Notice type: Sources sought
- Status: Closed. Deadline was July 20, 2026 at 10:00 AM EDT
- Department: Department of the Army
- Agency: Department of the Army
- Contracting office: W7M9 Uspfo Activity Ksang 184 (W50S7X)
- NAICS: 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Product or service code: J012 Maintenance, Repair and Rebuilding of Equipment: Fire Control Equipment
- Set-aside: Total small business set-aside
- Small business size standard: $19 million in average annual receipts (13 CFR 121.201, NAICS 238220)
- Place of performance: McConnell AFB, Kansas
- County: Sedgwick County (FIPS 20173). https://sealedbidder.com/counties/sedgwick-county-ks-20173
- City: McConnell AFB. https://sealedbidder.com/cities/mcconnell-afb-ks-2043675
- First posted: July 9, 2026
- Last posted: July 9, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/2d64fac728be4aa585ac98144a2b0381/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: Total small business set-aside. Only small businesses may compete. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates.
- What comes next: No solicitation has been published under this number yet. The sources sought of July 9, 2026 is the earliest notice of the purchase.

## Description

This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.

Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following:

	Building 33, Southwest Bay &ndash; 6-inch diameter Backflow Preventer System for Fire Suppression

		Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.

		Install a new 6-inch diameter Fire Suppression Backflow Prevention System.

		Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.

		Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:

			Backflow Prevention System&rsquo;s Installation Date

			Backflow Prevention System&rsquo;s Manufacture

			Backflow Prevention System&rsquo;s Model

			Backflow Prevention System&rsquo;s Serial Number

			Backflow Prevention System&rsquo;s Rebuild Kit Specifications

			Backflow Prevention System&rsquo;s Description

	Building 44, Room 122, South wall &ndash; 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve

		Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.

		Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.

		Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.

		Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:

			Backflow Prevention System&rsquo;s Installation Date

			Backflow Prevention System&rsquo;s Manufacture

			Backflow Prevention System&rsquo;s Model

			Backflow Prevention System&rsquo;s Serial Number

			Backflow Prevention System&rsquo;s Rebuild Kit Specifications

			Backflow Prevention System&rsquo;s Description

	Building 44, Room 118, Interior, Southeast wall &ndash; 1-inch diameter Backflow Preventer System for Boiler Makeup

		Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System.

		Install a new 1-inch diameter Boiler Makeup Backflow Prevention System.

		Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.

		Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:

			Backflow Prevention System&rsquo;s Installation Date

			Backflow Prevention System&rsquo;s Manufacture

			Backflow Prevention System&rsquo;s Model

			Backflow Prevention System&rsquo;s Serial Number

			Backflow Prevention System&rsquo;s Rebuild Kit Specifications

			Backflow Prevention System&rsquo;s Description

	Building 48, Room 107, East wall &ndash; 4-inch diameter Backflow Preventer System for Fire Suppression

		Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System.

		Install a new 4-inch diameter Fire Suppression Backflow Prevention System.

		Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.

		Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:

			Backflow Prevention System&rsquo;s Installation Date

			Backflow Prevention System&rsquo;s Manufacture

			Backflow Prevention System&rsquo;s Model

			Backflow Prevention System&rsquo;s Serial Number

			Backflow Prevention System&rsquo;s Rebuild Kit Specifications

			Backflow Prevention System&rsquo;s Description

	Building 65, Room 154, Interior, South &ndash; 2.5-inch diameter Backflow Preventer System for domestic water

		Remove the existing 2.5-inch diameter domestic water Backflow Prevention System.

		Install a new 2.5-inch diameter domestic water Backflow Prevention System.

		Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.

		Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:

			Backflow Prevention System&rsquo;s Installation Date

			Backflow Prevention System&rsquo;s Manufacture

			Backflow Prevention System&rsquo;s Model

			Backflow Prevention System&rsquo;s Serial Number

			Backflow Prevention System&rsquo;s Rebuild Kit Specifications

			Backflow Prevention System&rsquo;s Description

For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.

Attachments:

1. Statement of Work

2. Sources Sought Response Form

## Attachments

- [Sources Sought Response Form - Fire Suppression Backflow Preventer.pdf](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/eeee1773b5d54ae9a95c0cc6b7dab9f8/download)

## Open now in the same industry

59 open in NAICS 238220.

- BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031 (36C26227Q0149), due November 27, 2026 at 12:00 PM EST. https://sealedbidder.com/opportunities/36c26227q0149
- SOURCES SOUGHT NOTICE: Preventive Maintenance Services for Medical Gas and Vacuum Systems (IHS1532768), due November 27, 2026 at 2:00 PM EST. https://sealedbidder.com/opportunities/ihs1532768
- Remediation of storm damage to station multi-Purpose Bldg (30332Q270000002), due November 28, 2026 at 1:00 PM EST. https://sealedbidder.com/opportunities/30332q270000002

## Publications

- July 9, 2026: Sources sought, due July 20, 2026 at 10:00 AM EDT. Notice 2d64fac728be4aa585ac98144a2b0381. https://sam.gov/workspace/contract/opp/2d64fac728be4aa585ac98144a2b0381/view

## Points of contact

- Kevin Smith, 184wg.msg.contracting@us.af.mil, 3167597591
- Joshua Kingori, 184WG.MSG.CONTRACTING@us.af.mil, 3167597590

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/panngb26p0000038507.