{"canonical":"https://sealedbidder.com/opportunities/panngb26p0000038507","key":"PANNGB26P0000038507","url":"https://sealedbidder.com/opportunities/panngb26p0000038507","title":"Fire Suppression Backflow preventer","solicitation_number":"PANNGB26P0000038507","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-20T14:00:00Z","first_posted":"2026-07-09","last_posted":"2026-07-09","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W7M9 USPFO ACTIVITY KSANG 184","naics":"238220","psc":"J012","set_aside":"SBA","place_state":"KS","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"20173","place_county_name":"Sedgwick County","place_city":"2043675","place_city_name":"McConnell AFB","winner":null,"award_amount":null,"publications":[{"notice_id":"2d64fac728be4aa585ac98144a2b0381","title":"Fire Suppression Backflow preventer","solicitation_number":"PANNGB26P0000038507","notice_type":"r","base_type":"r","posted":"2026-07-09","posted_at":"2026-07-09T19:01:05.029Z","due_at":"2026-07-20T14:00:00Z","due_date":"2026-07-20","cancelled":false,"archived":true,"archive_date":"2026-08-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2d64fac728be4aa585ac98144a2b0381/view","enriched":true,"history":[{"index":3,"title":"Fire Suppression Backflow preventer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T19:01:05.029Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2d64fac728be4aa585ac98144a2b0381","solicitation_number":"PANNGB26P0000038507"}]}],"latest_notice_id":"2d64fac728be4aa585ac98144a2b0381","first_type":"r","notices":[{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T19:01:05.029Z","created_at":"2026-07-09T17:44:33.905Z","modified_at":"2026-08-04T05:06:30.242Z","response_deadline":{"raw":"2026-07-20T09:00:00-05:00","utc":"2026-07-20T14:00:00Z","date":"2026-07-20","time":"09:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2d64fac728be4aa585ac98144a2b0381/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Fire Suppression Backflow preventer","agency":{"office":{"code":"W50S7X","name":"W7M9 USPFO ACTIVITY KSANG 184"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"67221-9000","city":"MCCONNELL AFB","state":"KS","country":"USA"},"organization_id":"500044287","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-04","archive_type":"auto15"},"history":[{"index":3,"title":"Fire Suppression Backflow preventer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T19:01:05.029Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2d64fac728be4aa585ac98144a2b0381","solicitation_number":"PANNGB26P0000038507"}],"contacts":[{"name":"Kevin Smith","role":"primary","email":"184wg.msg.contracting@us.af.mil","phone":"3167597591"},{"name":"Joshua Kingori","role":"secondary","email":"184WG.MSG.CONTRACTING@us.af.mil","phone":"3167597590"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2d64fac728be4aa585ac98144a2b0381","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"2d64fac728be4aa585ac98144a2b0381","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T02:25:39.009537485Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"5b6b179432c7c04f2591dedeb00c1d91fc6209fee57dc9fe6315a7601704e913","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T02:25:39.009537485Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.</p>\n\n<p>Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades.&nbsp;The work shall consist of&nbsp;removal of the&nbsp;five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will&nbsp;be responsible for&nbsp;removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects&nbsp;nor&nbsp;leaks. The project needs to include the following:&nbsp;</p>\n\n<ol>\n\t<li>Building 33, Southwest Bay &ndash; 6-inch diameter Backflow Preventer System for Fire Suppression&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new 6-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 44, Room&nbsp;122, South wall &ndash; 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 44, Room&nbsp;118, Interior, Southeast wall &ndash; 1-inch diameter Backflow Preventer System for Boiler Makeup&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 1-inch diameter&nbsp;Boiler Makeup&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;1-inch diameter Boiler Makeup Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;1-inch diameter Boiler Makeup Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 48, Room&nbsp;107,&nbsp;East&nbsp;wall &ndash;&nbsp;4-inch diameter Backflow Preventer System for&nbsp;Fire Suppression&nbsp;\n\t<ol>\n\t\t<li>Remove the existing&nbsp;4-inch diameter&nbsp;Fire Suppression&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;4-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;4-inch diameter Fire Suppression Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 65, Room&nbsp;154, Interior, South &ndash;&nbsp;2.5-inch diameter Backflow Preventer System for&nbsp;domestic water&nbsp;\n\t<ol>\n\t\t<li>Remove the existing&nbsp;2.5-inch diameter&nbsp;domestic water&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;2.5-inch diameter domestic water Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;2.5-inch diameter domestic water Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business&nbsp;In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line &quot;Fire Suppression Backfow Preventer Upgrades&quot; when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.</p>\n\n<p>Attachments:</p>\n\n<p>1. Statement of Work</p>\n\n<p>2. Sources Sought Response Form</p>","text":"This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.\n\nKansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following:\n\n• Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression\n\n• Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.\n\n• Install a new 6-inch diameter Fire Suppression Backflow Prevention System.\n\n• Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve\n\n• Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.\n\n• Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.\n\n• Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup\n\n• Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System.\n\n• Install a new 1-inch diameter Boiler Makeup Backflow Prevention System.\n\n• Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression\n\n• Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System.\n\n• Install a new 4-inch diameter Fire Suppression Backflow Prevention System.\n\n• Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water\n\n• Remove the existing 2.5-inch diameter domestic water Backflow Prevention System.\n\n• Install a new 2.5-inch diameter domestic water Backflow Prevention System.\n\n• Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\nFor this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line \"Fire Suppression Backfow Preventer Upgrades\" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.\n\nAttachments:\n\n1. Statement of Work\n\n2. Sources Sought Response Form","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"PANNGB26P0000038507","place_of_performance":{"zip":"67221","city":{"code":"0","name":"McConnell AFB"},"state":{"code":"KS","name":"Kansas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J012"}],"due_at":"2026-07-20T14:00:00Z","due_date":"2026-07-20","closes_at":"2026-07-20T14:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S7X","office_name":"W7M9 USPFO ACTIVITY KSANG 184","state":"KS","county":"20173","county_name":"Sedgwick County","city":"2043675","city_name":"McConnell AFB","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T03:29:01.199186Z","principal_notice_id":"2d64fac728be4aa585ac98144a2b0381","description":{"text":"This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.\n\nKansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following:\n\n• Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression\n\n• Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.\n\n• Install a new 6-inch diameter Fire Suppression Backflow Prevention System.\n\n• Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve\n\n• Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.\n\n• Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.\n\n• Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup\n\n• Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System.\n\n• Install a new 1-inch diameter Boiler Makeup Backflow Prevention System.\n\n• Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression\n\n• Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System.\n\n• Install a new 4-inch diameter Fire Suppression Backflow Prevention System.\n\n• Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\n• Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water\n\n• Remove the existing 2.5-inch diameter domestic water Backflow Prevention System.\n\n• Install a new 2.5-inch diameter domestic water Backflow Prevention System.\n\n• Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County.\n\n• Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:\n\n• Backflow Prevention System’s Installation Date\n\n• Backflow Prevention System’s Manufacture\n\n• Backflow Prevention System’s Model\n\n• Backflow Prevention System’s Serial Number\n\n• Backflow Prevention System’s Rebuild Kit Specifications\n\n• Backflow Prevention System’s Description\n\nFor this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line \"Fire Suppression Backfow Preventer Upgrades\" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.\n\nAttachments:\n\n1. Statement of Work\n\n2. Sources Sought Response Form","html":"<p>This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond.</p>\n\n<p>Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades.&nbsp;The work shall consist of&nbsp;removal of the&nbsp;five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will&nbsp;be responsible for&nbsp;removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects&nbsp;nor&nbsp;leaks. The project needs to include the following:&nbsp;</p>\n\n<ol>\n\t<li>Building 33, Southwest Bay &ndash; 6-inch diameter Backflow Preventer System for Fire Suppression&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new 6-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 44, Room&nbsp;122, South wall &ndash; 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 44, Room&nbsp;118, Interior, Southeast wall &ndash; 1-inch diameter Backflow Preventer System for Boiler Makeup&nbsp;\n\t<ol>\n\t\t<li>Remove the existing 1-inch diameter&nbsp;Boiler Makeup&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;1-inch diameter Boiler Makeup Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;1-inch diameter Boiler Makeup Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 48, Room&nbsp;107,&nbsp;East&nbsp;wall &ndash;&nbsp;4-inch diameter Backflow Preventer System for&nbsp;Fire Suppression&nbsp;\n\t<ol>\n\t\t<li>Remove the existing&nbsp;4-inch diameter&nbsp;Fire Suppression&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;4-inch diameter Fire Suppression Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;4-inch diameter Fire Suppression Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n\t<li>Building 65, Room&nbsp;154, Interior, South &ndash;&nbsp;2.5-inch diameter Backflow Preventer System for&nbsp;domestic water&nbsp;\n\t<ol>\n\t\t<li>Remove the existing&nbsp;2.5-inch diameter&nbsp;domestic water&nbsp;Backflow Prevention System.&nbsp;</li>\n\t\t<li>Install a new&nbsp;2.5-inch diameter domestic water Backflow Prevention System.&nbsp;</li>\n\t\t<li>Testing of the newly installed&nbsp;2.5-inch diameter domestic water Backflow Prevention System&nbsp;by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita &amp; Sedwick County.&nbsp;</li>\n\t\t<li>Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following:&nbsp;\n\t\t<ol>\n\t\t\t<li>Backflow Prevention System&rsquo;s Installation Date&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Manufacture&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Model&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Serial Number&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Rebuild Kit Specifications&nbsp;</li>\n\t\t\t<li>Backflow Prevention System&rsquo;s Description&nbsp;</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business&nbsp;In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line &quot;Fire Suppression Backfow Preventer Upgrades&quot; when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions.</p>\n\n<p>Attachments:</p>\n\n<p>1. Statement of Work</p>\n\n<p>2. Sources Sought Response Form</p>","origin":"detail"},"contacts":[{"name":"Kevin Smith","role":"primary","email":"184wg.msg.contracting@us.af.mil","phone":"3167597591"},{"name":"Joshua Kingori","role":"secondary","email":"184WG.MSG.CONTRACTING@us.af.mil","phone":"3167597590"}],"place_of_performance":{"zip":"67221","city":{"code":"0","name":"McConnell AFB"},"state":{"code":"KS","name":"Kansas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"67221-9000","city":"MCCONNELL AFB","state":"KS","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"eeee1773b5d54ae9a95c0cc6b7dab9f8","name":"Sources Sought Response Form - Fire Suppression Backflow Preventer.pdf","kind":"file","mime_type":".pdf","size_bytes":159929,"posted_at":"2026-07-09T19:01:05.029Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/eeee1773b5d54ae9a95c0cc6b7dab9f8/download","mirrored":false}],"awards":[],"related":[{"key":"W50S7X27Q0001","latest_notice_id":"80d75e4887404736b971a18a02e5f64e","title":"Switchgear Transformer Replacement","solicitation_number":"W50S7X27Q0001","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-20","notices":8,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S7X","office_name":"W7M9 USPFO ACTIVITY KSANG 184","naics":"335311","psc":"5950","set_aside":"SBA","state":"KS","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"57330 MUSTANG DR BLDG 42 MCCONNELLAFB, KS 67221-9000 UNITED STATES","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open":[{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"IHS1532768","latest_notice_id":"a173f2538e054794af04e5aa126d48b4","title":"SOURCES SOUGHT NOTICE: Preventive Maintenance Services for Medical Gas and Vacuum Systems","solicitation_number":"IHS1532768","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H710","office_name":"NAVAJO AREA INDIAN HEALTH SVC","naics":"238220","psc":"J045","set_aside":null,"state":"AZ","county":"04005","county_name":"Coconino County","city":"0474470","city_name":"Tonalea","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"30332Q270000002","latest_notice_id":"edb8b91a6c8d46b29652376b51dd3d21","title":"Remediation of storm damage to station multi-Purpose Bldg","solicitation_number":"30332Q270000002","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-28T18:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL28","office_name":"BASE NEW ORLEANS","naics":"238220","psc":"Z2AZ","set_aside":"SBA","state":"AL","county":"01097","county_name":"Mobile County","city":"0119744","city_name":"Dauphin Island","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":59,"indexable":false}