Multisizer 4e Coulter Counter
75N98026Q00434
National Institutes of Health, National Institutes of Health Olao. Analytical Laboratory Instrument Manufacturing.
Response deadline
June 3, 2026 at 9:00 AM EDT
Closed 176 days ago. Posted May 22, 2026. Scheduled to archive June 3, 2026.
Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities
This one closed in 2026
55 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due in 2 daysNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 5 daysDec 1
All 55 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the presolicitation of May 22, 2026. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The required Multisizer provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols.
Specifications & Requirements
The product shall include/use:
- Coulter method of measurement using patented digital pulse processing technology
- Automatic aperture blockage detection and clearing during runs and sample analysis
- Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers
- Fluid level monitoring for solutions and waste
- Selectable stirrer speed and direction
- Particle sizing range: 0.2 – 1,600uM
- Measurement range: 2 – 80% of aperture size
- Measurement linearity: Diameter ± 1%, Volume ± 3%
- Dynamic range (accuracy): 1:40 (diameter), 1:64,000 (volume)
- Accurate determination of sample cell number, size, distribution, and concentration
- Particle count, sizing, and volume distribution data, including diameter, volume, and area of number, number percent, number per mL, volume, volume percent, volume per mL, surface area, surface area percent, surface area per mL
- Pulse distribution data, including time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average pulse height diameter, average pulse height volume and average pulse width. Number distribution by width.
- Up to 400 size classes or channels with the ability to change number of size classes or channels and width and reprocess as needed without having to re-run the samples
- Time-stamped pulses up to 525,000 per single analysis
- Modes for Total Count (up to 500,000 counts), Modal Count (up to 100,000 counts), and Volumetric Count (up to 2000uL)
- Digital Pulse Processor with proprietary high-speed signal digitalization
- Real time detection of volume changes
- Stirrer with ability to adjust stir speed and direction for even particle distribution in sample suspensions
- 100uM and 400uM size aperture tubes, with instrument ability to use apertures ranging from 10uM up to 2000uM size as needed, with aperture tube calibration and verification
- 100/200mL beakers, with ability to use additional size beakers and accuvettes, as required by the sample type, sample volume, or other need
- Isoton II Diluent and Coulter Clenz solutions for instrument operation and cleaning, and spigot assemblies for both solutions
- Mixed Standards Kit (L2, L5, L10, L20, L40)
- 300uM Particle Standard
- Installation
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Specifications Requirements rev2.docx19 KB, May 22, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 22, 2026
Presolicitation
Due June 3, 2026 at 9:00 AM EDT. SAM.gov, notice 1a8af077f9a74b35963e4c47cfe527cf
1 revision on SAM
- May 22, 2026: publish, presolicitation
Points of contact
- John Burtonburtonjo@mail.nih.gov