{"canonical":"https://sealedbidder.com/opportunities/75n98026q00434","key":"75N98026Q00434","url":"https://sealedbidder.com/opportunities/75n98026q00434","title":"Multisizer 4e Coulter Counter","solicitation_number":"75N98026Q00434","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-03T13:00:00Z","first_posted":"2026-05-22","last_posted":"2026-05-22","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"1a8af077f9a74b35963e4c47cfe527cf","title":"Multisizer 4e Coulter Counter","solicitation_number":"75N98026Q00434","notice_type":"p","base_type":"p","posted":"2026-05-22","posted_at":"2026-05-22T13:24:46.091Z","due_at":"2026-06-03T13:00:00Z","due_date":"2026-06-03","cancelled":false,"archived":true,"archive_date":"2026-06-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1a8af077f9a74b35963e4c47cfe527cf/view","enriched":true,"history":[{"index":3,"title":"Multisizer 4e Coulter Counter","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-22T13:24:46.091Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1a8af077f9a74b35963e4c47cfe527cf","solicitation_number":"75N98026Q00434"}]}],"latest_notice_id":"1a8af077f9a74b35963e4c47cfe527cf","first_type":"p","notices":[{"dates":{"posted":"2026-05-22","posted_at":"2026-05-22T13:24:46.091Z","created_at":"2026-05-22T12:54:48.858Z","modified_at":"2026-06-04T03:55:45.207Z","response_deadline":{"raw":"2026-06-03T09:00:00-04:00","utc":"2026-06-03T13:00:00Z","date":"2026-06-03","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1a8af077f9a74b35963e4c47cfe527cf/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Multisizer 4e Coulter Counter","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_id":"100189057","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-03","archive_type":"auto_custom"},"history":[{"index":3,"title":"Multisizer 4e Coulter Counter","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-22T13:24:46.091Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1a8af077f9a74b35963e4c47cfe527cf","solicitation_number":"75N98026Q00434"}],"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"1a8af077f9a74b35963e4c47cfe527cf","lineage_id":"1a8af077f9a74b35963e4c47cfe527cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T03:19:41.237199573Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"9ada08a769facef2a02aeb15c4acaf26fe407e5c454fa2e4a798f77edd5587b5","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-03T03:19:41.237199573Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The required&nbsp;Multisizer&nbsp;provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols.&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;<strong>Specifications &amp; Requirements</strong></p>\n\n<p></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The product shall include/use:&nbsp;</p>\n\n<ul>\n\t<li>Coulter method of measurement&nbsp;using patented digital pulse processing technology&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Automatic aperture blockage&nbsp;detection and&nbsp;clearing during runs and sample analysis&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Fluid level monitoring&nbsp;for solutions and waste&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Selectable stirrer speed and direction&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Particle sizing&nbsp;range: 0.2 &ndash; 1,600uM&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Measurement range:&nbsp;2 &ndash; 80% of aperture size&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Measurement linearity: Diameter &plusmn; 1%, Volume &plusmn; 3%&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Dynamic range&nbsp;(accuracy): 1:40 (diameter), 1:64,000&nbsp;(volume)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Accurate determination of sample cell number, size,&nbsp;distribution,&nbsp;and concentration&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Particle count, sizing,&nbsp;and volume distribution&nbsp;data, including diameter, volume,&nbsp;and area of number, number&nbsp;percent, number&nbsp;per&nbsp;mL, volume, volume&nbsp;percent, volume&nbsp;per&nbsp;mL, surface&nbsp;area, surface area&nbsp;percent, surface area&nbsp;per&nbsp;mL&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Pulse distribution data, including&nbsp;time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average&nbsp;pulse&nbsp;height diameter, average pulse height&nbsp;volume&nbsp;and average pulse width. Number distribution by width.&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Up to 400 size classes&nbsp;or&nbsp;channels&nbsp;with the ability to change number of size classes&nbsp;or&nbsp;channels&nbsp;and width&nbsp;and reprocess&nbsp;as needed&nbsp;without having to re-run the samples&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Time-stamped pulses up to 525,000&nbsp;per single analysis&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Modes for Total Count (up to 500,000&nbsp;counts), Modal Count (up to&nbsp;100,000 counts), and Volumetric Count (up to 2000uL)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Digital Pulse Processor with proprietary high-speed signal digitalization&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Real time detection of volume changes&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Stirrer&nbsp;with ability to adjust stir speed and direction for even particle distribution in sample suspensions&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>100uM and 400uM&nbsp;size&nbsp;aperture tubes, with&nbsp;instrument&nbsp;ability to use&nbsp;apertures ranging from 10uM&nbsp;up to 2000uM&nbsp;size&nbsp;as needed, with&nbsp;aperture&nbsp;tube&nbsp;calibration and verification&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>100/200mL beakers, with ability to use&nbsp;additional&nbsp;size beakers and&nbsp;accuvettes, as required by the sample type, sample volume, or other need&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Isoton&nbsp;II Diluent and Coulter&nbsp;Clenz&nbsp;solutions&nbsp;for instrument operation and cleaning,&nbsp;and spigot assemblies&nbsp;for both solutions&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Mixed Standards Kit (L2, L5, L10, L20, L40)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>300uM Particle Standard&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Installation&nbsp;</li>\n</ul>\n\n<p></p>","text":"The required Multisizer provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols.\n\nSpecifications & Requirements\n\nThe product shall include/use:\n\n• Coulter method of measurement using patented digital pulse processing technology\n\n• Automatic aperture blockage detection and clearing during runs and sample analysis\n\n• Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers\n\n• Fluid level monitoring for solutions and waste\n\n• Selectable stirrer speed and direction\n\n• Particle sizing range: 0.2 – 1,600uM\n\n• Measurement range: 2 – 80% of aperture size\n\n• Measurement linearity: Diameter ± 1%, Volume ± 3%\n\n• Dynamic range (accuracy): 1:40 (diameter), 1:64,000 (volume)\n\n• Accurate determination of sample cell number, size, distribution, and concentration\n\n• Particle count, sizing, and volume distribution data, including diameter, volume, and area of number, number percent, number per mL, volume, volume percent, volume per mL, surface area, surface area percent, surface area per mL\n\n• Pulse distribution data, including time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average pulse height diameter, average pulse height volume and average pulse width. Number distribution by width.\n\n• Up to 400 size classes or channels with the ability to change number of size classes or channels and width and reprocess as needed without having to re-run the samples\n\n• Time-stamped pulses up to 525,000 per single analysis\n\n• Modes for Total Count (up to 500,000 counts), Modal Count (up to 100,000 counts), and Volumetric Count (up to 2000uL)\n\n• Digital Pulse Processor with proprietary high-speed signal digitalization\n\n• Real time detection of volume changes\n\n• Stirrer with ability to adjust stir speed and direction for even particle distribution in sample suspensions\n\n• 100uM and 400uM size aperture tubes, with instrument ability to use apertures ranging from 10uM up to 2000uM size as needed, with aperture tube calibration and verification\n\n• 100/200mL beakers, with ability to use additional size beakers and accuvettes, as required by the sample type, sample volume, or other need\n\n• Isoton II Diluent and Coulter Clenz solutions for instrument operation and cleaning, and spigot assemblies for both solutions\n\n• Mixed Standards Kit (L2, L5, L10, L20, L40)\n\n• 300uM Particle Standard\n\n• Installation","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"75N98026Q00434","place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-06-03T13:00:00Z","due_date":"2026-06-03","closes_at":"2026-06-03T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T03:22:18.780940Z","principal_notice_id":"1a8af077f9a74b35963e4c47cfe527cf","description":{"text":"The required Multisizer provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols.\n\nSpecifications & Requirements\n\nThe product shall include/use:\n\n• Coulter method of measurement using patented digital pulse processing technology\n\n• Automatic aperture blockage detection and clearing during runs and sample analysis\n\n• Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers\n\n• Fluid level monitoring for solutions and waste\n\n• Selectable stirrer speed and direction\n\n• Particle sizing range: 0.2 – 1,600uM\n\n• Measurement range: 2 – 80% of aperture size\n\n• Measurement linearity: Diameter ± 1%, Volume ± 3%\n\n• Dynamic range (accuracy): 1:40 (diameter), 1:64,000 (volume)\n\n• Accurate determination of sample cell number, size, distribution, and concentration\n\n• Particle count, sizing, and volume distribution data, including diameter, volume, and area of number, number percent, number per mL, volume, volume percent, volume per mL, surface area, surface area percent, surface area per mL\n\n• Pulse distribution data, including time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average pulse height diameter, average pulse height volume and average pulse width. Number distribution by width.\n\n• Up to 400 size classes or channels with the ability to change number of size classes or channels and width and reprocess as needed without having to re-run the samples\n\n• Time-stamped pulses up to 525,000 per single analysis\n\n• Modes for Total Count (up to 500,000 counts), Modal Count (up to 100,000 counts), and Volumetric Count (up to 2000uL)\n\n• Digital Pulse Processor with proprietary high-speed signal digitalization\n\n• Real time detection of volume changes\n\n• Stirrer with ability to adjust stir speed and direction for even particle distribution in sample suspensions\n\n• 100uM and 400uM size aperture tubes, with instrument ability to use apertures ranging from 10uM up to 2000uM size as needed, with aperture tube calibration and verification\n\n• 100/200mL beakers, with ability to use additional size beakers and accuvettes, as required by the sample type, sample volume, or other need\n\n• Isoton II Diluent and Coulter Clenz solutions for instrument operation and cleaning, and spigot assemblies for both solutions\n\n• Mixed Standards Kit (L2, L5, L10, L20, L40)\n\n• 300uM Particle Standard\n\n• Installation","html":"<p>The required&nbsp;Multisizer&nbsp;provides improved functionality and analysis capabilities, in addition to allowing continued measurement of cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols.&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;<strong>Specifications &amp; Requirements</strong></p>\n\n<p></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The product shall include/use:&nbsp;</p>\n\n<ul>\n\t<li>Coulter method of measurement&nbsp;using patented digital pulse processing technology&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Automatic aperture blockage&nbsp;detection and&nbsp;clearing during runs and sample analysis&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Code scanner to scan bar codes on samples, electrolytes, aperture tubes, and sample beakers&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Fluid level monitoring&nbsp;for solutions and waste&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Selectable stirrer speed and direction&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Particle sizing&nbsp;range: 0.2 &ndash; 1,600uM&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Measurement range:&nbsp;2 &ndash; 80% of aperture size&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Measurement linearity: Diameter &plusmn; 1%, Volume &plusmn; 3%&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Dynamic range&nbsp;(accuracy): 1:40 (diameter), 1:64,000&nbsp;(volume)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Accurate determination of sample cell number, size,&nbsp;distribution,&nbsp;and concentration&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Particle count, sizing,&nbsp;and volume distribution&nbsp;data, including diameter, volume,&nbsp;and area of number, number&nbsp;percent, number&nbsp;per&nbsp;mL, volume, volume&nbsp;percent, volume&nbsp;per&nbsp;mL, surface&nbsp;area, surface area&nbsp;percent, surface area&nbsp;per&nbsp;mL&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Pulse distribution data, including&nbsp;time, sequence and width for pulse height diameter, pulse height volume, pulse height volt, pulse width, pulse area, average&nbsp;pulse&nbsp;height diameter, average pulse height&nbsp;volume&nbsp;and average pulse width. Number distribution by width.&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Up to 400 size classes&nbsp;or&nbsp;channels&nbsp;with the ability to change number of size classes&nbsp;or&nbsp;channels&nbsp;and width&nbsp;and reprocess&nbsp;as needed&nbsp;without having to re-run the samples&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Time-stamped pulses up to 525,000&nbsp;per single analysis&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Modes for Total Count (up to 500,000&nbsp;counts), Modal Count (up to&nbsp;100,000 counts), and Volumetric Count (up to 2000uL)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Digital Pulse Processor with proprietary high-speed signal digitalization&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Real time detection of volume changes&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Stirrer&nbsp;with ability to adjust stir speed and direction for even particle distribution in sample suspensions&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>100uM and 400uM&nbsp;size&nbsp;aperture tubes, with&nbsp;instrument&nbsp;ability to use&nbsp;apertures ranging from 10uM&nbsp;up to 2000uM&nbsp;size&nbsp;as needed, with&nbsp;aperture&nbsp;tube&nbsp;calibration and verification&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>100/200mL beakers, with ability to use&nbsp;additional&nbsp;size beakers and&nbsp;accuvettes, as required by the sample type, sample volume, or other need&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Isoton&nbsp;II Diluent and Coulter&nbsp;Clenz&nbsp;solutions&nbsp;for instrument operation and cleaning,&nbsp;and spigot assemblies&nbsp;for both solutions&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Mixed Standards Kit (L2, L5, L10, L20, L40)&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>300uM Particle Standard&nbsp;</li>\n</ul>\n\n<p></p>\n\n<ul>\n\t<li>Installation&nbsp;</li>\n</ul>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"9e7db78c24fa4fb18300dfc8a7c2014f","name":"Specifications Requirements rev2.docx","kind":"file","mime_type":".docx","size_bytes":19691,"posted_at":"2026-05-22T13:24:46.091Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9e7db78c24fa4fb18300dfc8a7c2014f/download","mirrored":false}],"awards":[],"related":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}