Presolicitation, total small business set-aside, first published as solicitation
FLUKE T5-1000
SPMYM125Q0137
Defense Logistics Agency, DLA Maritime - Norfolk. Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals.
Awarded
Supply Solutions International, Inc.
$27,700.00 obligated so far on USAspending
Get the next one like this from Defense Logistics Agency by email, the day it is posted.Find my opportunities
This one was awarded in 2025
45 like it are open now in instrument manufacturing for measuring and testing electricity and electrical signals
- Request for Information Authorized Distributors/Resellers of Keysight Technologies Products
Department of the Navy, NAVAIR Warfare CTR Aircraft Div
Sources soughtNAICS 334515Ship to Gulfport, MSN68335-26-RFPREQ-BL31000-0026Due todayNov 26 - SERVER,AUTOMATIC DA
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 334515Ship to the buyerN0010426QNF12Due tomorrowNov 27 - SERVER,AUTOMATIC DA
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 334515Ship to the buyerN0010426QNE27Due tomorrowNov 27
All 45 open in instrument manufacturing for measuring and testing electricity and electrical signals
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 334515 (instrument manufacturing for measuring and testing electricity and electrical signals), means no more than 750 employees, counted with affiliates. Open Small business opportunities
- Time to respond
- Bidders had 6 days from the day the solicitation was posted, August 7, 2025, to the deadline.
- How it ended
- Awarded to Supply Solutions International, Inc. on August 25, 2025, 12 days after offers were due. The contracting office reported 2 offers (competed under simplified acquisition procedures).
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)
intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically
Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for
commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart
12.6, as supplemented with the additional information included in this notice.
The Contract Line Item (CLIN) is as follows:
ITEM NO.
DESCRIPTION
QTY
U/I
UNIT PRICE
TOTAL
0001
FLUKE T5-1000
ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER
MODEL#: FLUKE T5-H5-1AC II KIT
REF P/N 2PY98
100
EA
Determined by vendors
Determined by vendors
T5-600/T5-1000
Electrical Tester
Parts and Service
The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the
TS-600/TS-1000 Electrical Tester Instruction Sheet.
To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.
Specifications
Accuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:
::!;([ % of reading] + [number of least significant digits])
Temperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)
Serial Numbers 79560000 and Above
General Specifications
Calibration
One-year calibration cycle.
Maximum Voltage
Between any Terminal and Earth Ground
TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2
TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2
Maximum Voltage
Between Current Fork and Earth Ground
TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)
Relative Humidity
O o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);
O o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)
Battery Type and Life
AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride
Shock, Vibration
1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1
1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)
Surge Protection
TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010
Enclosure Rating
IP 52 per IEC 60529, no vacuum applied
General Specifications (continued)
RF Field Specification
0.5 % full scale + (specified accuracy) at 3 V/m
Safety
Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.
EMC
EN 61326
Certifications
CE <ti® ��S®IF,� C
In accordance with IEC 61010-1 54CJ
Resolution and Accuracy
Function
TS-600 Range
TS-1000 Range
Resolution
Accuracy
v
600 V rms
1000 V rms
lV
:!(1.5 % + 2 digits)
v
600V
1000V
lV
:!(1% + 1 digit)
~A
100.0A
100.0A
0.lA
:!(3 % + 3 digits)
n
10000
1000 0
10
:!(1o/o + 2 digits)
Input Characteristics
Function
Input Protection
Input impedance (nomial
T5-600
TS-1000
v
600 V rms
1000 V rms
1 MO, <100 pF ac-coupled
v
600 V rms
1000 V rms
1 MO, <100 pF
n
600 V rms
1000 V rms
n
Open Circuit Test Voltage
Short Circuit Current
1.65 V de (nominal)
<600 µA
CAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.
CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.
Serial Numbers 79559999 and Below
General Specifications
Calibration
One-year calibration cycle.
Maximum Voltage Between any Terminal
and Earth Ground
TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)
Relative Humidity
0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);
0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)
Battery Type and Life
AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride
T5-600/T5-1000
Electrical Tester
General Specifications (continued)
Shock, Vibration
1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.
Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)
Surge Protection
T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09
Enclosure Rating
IP 52 per IEC 60529, no vacuum applied
RF Field Specification
0.5 % full scale + (specified accuracy) at 3 V/m
Safety
Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.
EMC
EN 50081-1, EN 50082-1
Certifications
( E c@us ct ®®
Resolution and Accuracy
Function
TS-600 Range
TS-1000 Range
Resolution
Accuracy
v
600 V rms
1000 V rms
lV
:!(1.5 % + 2 digits)
v
600V
1000V
lV
:!(1% + 1 digit)
A
100.0A
100.0A
0.lA
:!(3 % + 3 digits)
n
10000
10000
10
:!(1% + 2 digits)
Input Characteristics
Function
Input Protection
Input impedance (nomial
T5-600
T5-1000
v
600 V rms
1000 V rms
1 MO, <100 pF ac-coupled
v
600 V rms
1000 V rms
1 MO, <100 pF
n
600 V rms
1000 V rms
n
Open Circuit Test Voltage
Short Circuit Current
2.4 V de (nominal)
<600 µA
CAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.
CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.
Cleaning the Tester
�Warning
To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.
If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.
The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.
The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. THE SOLICITATION IS NOT YET AVAILABLE.
The solicitation number is SPMYM125Q0137, and it is expected to be available on or about
07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number
(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails
without subject lines will not be read because of security issues.
Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.
All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the
solicitation, except for awards to foreign vendors for work to be performed outside the United
States. Lack of registration in the SAM database will make an offeror ineligible for award.
Offerors may obtain information on registration and annual confirmation requirements by calling
1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in
accordance with the solicitation, dates and procedures. Please direct all questions regarding this
requirement to Curtis Douglas at Curtis.douglas@dla.mil
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- KO approved Solicitation SPMYM125Q0137 JML 51182700.pdf1.3 MB, August 7, 2025
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Supply Solutions International, Inc.
- UEI
- LEJDP6LSN5M7
- CAGE
- 8FBX3
- Vendor location
- Temecula, CA
- Contract
- SPMYM125P1414, purchase order
- Obligated
- $27,700.00
- Actions
- 2 between August 25, 2025 and September 11, 2025
- Competition
- Competed Under SAP, 2 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- N4215851182700 Fluke T5
- Match
- solicitation number SPMYM125Q0137 equals the FPDS solicitation identifier; same awarding office SPMYM1 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 7, 2025
Solicitation, originally presolicitation
Due August 13, 2025 at 12:00 PM EDT. SAM.gov, notice 0776d04b773d42e29770ec399408efcc
2 revisions on SAM
- August 7, 2025: publish, solicitation
- August 7, 2025: publish, presolicitation
August 7, 2025
Presolicitation
Due August 13, 2025 at 12:00 PM EDT. SAM.gov, notice af8a37e1bb004629aa1bd31efb5d32d1
2 revisions on SAM
- August 7, 2025: publish, solicitation
- August 7, 2025: publish, presolicitation
Points of contact
- CURTIS DOUGLAScurtis.douglas@dla.mil7572785058