{"canonical":"https://sealedbidder.com/opportunities/spmym125q0137","key":"SPMYM125Q0137","url":"https://sealedbidder.com/opportunities/spmym125q0137","title":"FLUKE T5-1000","solicitation_number":"SPMYM125Q0137","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-13T16:00:00Z","first_posted":"2025-08-07","last_posted":"2025-08-07","department":"DEPT OF DEFENSE","subagency":"DEFENSE LOGISTICS AGENCY","office":"DLA MARITIME - NORFOLK","naics":"334515","psc":"6625","set_aside":"SBA","place_state":"VA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"51740","place_county_name":"City of Portsmouth","place_city":"5164000","place_city_name":"Portsmouth","winner":"SUPPLY SOLUTIONS INTERNATIONAL, INC.","award_amount":null,"publications":[{"notice_id":"0776d04b773d42e29770ec399408efcc","title":"FLUKE T5-1000","solicitation_number":"SPMYM125Q0137","notice_type":"o","base_type":"p","posted":"2025-08-07","posted_at":"2025-08-07T17:55:15.964Z","due_at":"2025-08-13T16:00:00Z","due_date":"2025-08-13","cancelled":false,"archived":true,"archive_date":"2025-08-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0776d04b773d42e29770ec399408efcc/view","enriched":true,"history":[{"index":6,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:55:15.964Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0776d04b773d42e29770ec399408efcc","solicitation_number":"SPMYM125Q0137","related_opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1"},{"index":4,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:48:07.740Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1","solicitation_number":"SPMYM125Q0137"}]},{"notice_id":"af8a37e1bb004629aa1bd31efb5d32d1","title":"FLUKE T5-1000","solicitation_number":"SPMYM125Q0137","notice_type":"p","base_type":"p","posted":"2025-08-07","posted_at":"2025-08-07T17:48:07.740Z","due_at":"2025-08-13T16:00:00Z","due_date":"2025-08-13","cancelled":false,"archived":true,"archive_date":"2025-08-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/af8a37e1bb004629aa1bd31efb5d32d1/view","enriched":true,"history":[{"index":6,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:55:15.964Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0776d04b773d42e29770ec399408efcc","solicitation_number":"SPMYM125Q0137","related_opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1"},{"index":4,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:48:07.740Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1","solicitation_number":"SPMYM125Q0137"}]}],"latest_notice_id":"af8a37e1bb004629aa1bd31efb5d32d1","first_type":"o","notices":[{"dates":{"posted":"2025-08-07","posted_at":"2025-08-07T17:55:15.964Z","created_at":"2025-08-07T17:48:58.059Z","modified_at":"2025-08-29T04:04:37.364Z","response_deadline":{"raw":"2025-08-13T12:00:00-04:00","utc":"2025-08-13T16:00:00Z","date":"2025-08-13","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0776d04b773d42e29770ec399408efcc/view"},"naics":{"codes":["334515"],"primary":"334515"},"title":"FLUKE T5-1000","agency":{"office":{"code":"SPMYM1","name":"DLA MARITIME - NORFOLK"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"23709-5000","city":"PORTSMOUTH","state":"VA","country":"USA"},"organization_id":"500032825","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-28","archive_type":"auto15"},"history":[{"index":6,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:55:15.964Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0776d04b773d42e29770ec399408efcc","solicitation_number":"SPMYM125Q0137","related_opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1"},{"index":4,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:48:07.740Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1","solicitation_number":"SPMYM125Q0137"}],"contacts":[{"name":"CURTIS DOUGLAS","role":"primary","email":"curtis.douglas@dla.mil","phone":"7572785058"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"0776d04b773d42e29770ec399408efcc","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"af8a37e1bb004629aa1bd31efb5d32d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-05T02:09:48.847102471Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"66bcd27e803cc1107e91bcb6b20e09ff331b452a95342ab830af5f61fda100b7","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-05T02:09:48.847102471Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)</p>\n\n<p>intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically</p>\n\n<p>Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for</p>\n\n<p>commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart</p>\n\n<p>12.6, as supplemented with the additional information included in this notice.</p>\n\n<p></p>\n\n<p>The Contract Line Item (CLIN) is as follows:</p>\n\n<p></p>\n\n<p><strong>ITEM NO.</strong></p>\n\n<p><strong><u>DESCRIPTION</u></strong></p>\n\n<p><strong><u>QTY</u></strong></p>\n\n<p><strong><u>U/I</u></strong></p>\n\n<p><strong><u>UNIT PRICE</u></strong></p>\n\n<p><strong><u>TOTAL</u></strong></p>\n\n<p>0001</p>\n\n<p>FLUKE T5-1000</p>\n\n<p>ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER</p>\n\n<p>MODEL#: FLUKE T5-H5-1AC II KIT</p>\n\n<p><u>REF P/N 2PY98</u></p>\n\n<p></p>\n\n<p>100</p>\n\n<p>EA</p>\n\n<p>Determined by vendors</p>\n\n<p>Determined by vendors</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><em>Parts and Service</em></p>\n\n<p>The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the</p>\n\n<p><em>TS-600/TS-1000 Electrical Tester Instruction Sheet.</em></p>\n\n<p>To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)</p>\n\n<p>Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200</p>\n\n<p>Japan: +81-3-3434-0181</p>\n\n<p>Singapore: +65-738-5655</p>\n\n<p>Anywhere in the world: +1-425-446-5500 Or, visit Fluke&#39;s Web site at www.fluke.com.</p>\n\n<p></p>\n\n<p><em>Specifications</em></p>\n\n<p>Accuracy is specified for one year after calibration, at 18 &deg;C to 28 &deg;C (64 &deg;F to 82 &deg;F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:</p>\n\n<p>::!;([ % of reading] + [number of least significant digits])</p>\n\n<p>Temperature coefficient of 0.1 x (specified accuracy)/ &deg;C for &lt;18 &deg;C or &gt;28 &deg;C (&lt;64.4 &deg;For &gt;82.4 &deg;F)</p>\n\n<p></p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79560000 </strong><strong><em>and Above</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between any Terminal and Earth Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2</p>\n\n<p>TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between Current Fork and Earth Ground</strong></p>\n\n<p>TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>O o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); o o/o to 75 %, 30 &deg;C to 40 &deg;C (86 &deg;F to 104 &deg;F);</p>\n\n<p>O o/o to 45 %, 40 &deg;C to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery Type and Life</strong></p>\n\n<p>AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride</p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at -10 &deg;C to + 50 &deg;C (14 &deg;F to 122 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-1</p>\n\n<p>1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p></p>\n\n<p><em>General</em><em> </em><em>Specifications</em><em> </em><em>(continued)</em></p>\n\n<p></p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 61326</p>\n\n<p><strong>Certifications</strong></p>\n\n<p><strong>CE</strong><strong>&nbsp;</strong>&lt;ti&reg;&nbsp;�<em>�</em><em>S</em>&reg;<em>IF,�</em><em>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </em><strong>C</strong></p>\n\n<p>In accordance with IEC 61010-1 54CJ</p>\n\n<p><strong><em>Resolution and Accuracy</em></strong></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>TS-600 Range</strong></p>\n\n<p><strong>TS-1000 Range</strong></p>\n\n<p><strong>Resolution</strong></p>\n\n<p><strong>Accuracy</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>~<strong>A</strong></p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>1000 0</p>\n\n<p>10</p>\n\n<p>:!(1o/o + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>Input Protection</p>\n\n<p>Input impedance (nomial</p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>TS-</strong><strong>1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>1.65 V de (nominal)</p>\n\n<p>&lt;600 <strong>&micro;A</strong></p>\n\n<p>CAT Ill protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT</strong><strong> </strong><strong>IV</strong><strong> </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79559999 </strong><strong><em>and Below</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage Between any Terminal</strong></p>\n\n<p><strong>and</strong><strong> </strong><strong>Earth</strong><strong> </strong><strong>Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>0 o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); 0 o/o to 75 %, 30 &deg;C to 40 &deg;c (86 &deg;F to 104 &deg;F);</p>\n\n<p>0 o/o to 45 %, 40 &deg;c to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery</strong><strong> </strong><strong>Type</strong><strong> </strong><strong>and</strong><strong> </strong><strong>Life</strong></p>\n\n<p>AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><em>General Specifications (continued)</em></strong></p>\n\n<p></p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at 15 &deg;C to 35 &deg;c (59 &deg;F to 95 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.</p>\n\n<p>Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 50081-1, EN 50082-1</p>\n\n<p><strong>Certifications</strong></p>\n\n<p>( <strong>E </strong>c@us <u>c</u>t &reg;&reg;</p>\n\n<p><em>Resolution and Accuracy</em></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>TS-600 Range</p>\n\n<p>TS-1000 Range</p>\n\n<p>Resolution</p>\n\n<p>Accuracy</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>A</p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>10000</p>\n\n<p>10</p>\n\n<p>:!(1% + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>Input Protection</strong></p>\n\n<p><strong>Input impedance (nomial</strong></p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>T5-1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>2.4 V de (nominal)</p>\n\n<p>&lt;600 &micro;A</p>\n\n<p><strong>CAT 111 </strong>protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT IV </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><em>Cleaning the Tester</em></p>\n\n<p><strong>�Warning</strong></p>\n\n<p><strong>To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester&#39;s case, never use solvents on the tester.</strong></p>\n\n<p>If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The requirement will be solicited as a total small business set aside</strong>. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.</p>\n\n<p></p>\n\n<p>The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only.</p>\n\n<p></p>\n\n<p>The solicitation number is <strong>SPMYM125Q0137, </strong>and it is expected to be available on or about<strong> </strong></p>\n\n<p><strong>07 AUG 2025 </strong>and posted to SAM.gov, https://sam.gov/ Quotes will be due by <strong>12:00 PM EST </strong>on <strong>13 AUG 2025. </strong>Responses to the solicitation notice shall be emailed to the attention of <strong>Curtis Douglas </strong>at Curtis.douglas@dla.mil &nbsp;. Please make sure that the solicitation number</p>\n\n<p>(<strong>SPMYM125Q0137</strong>) is included in the subject line of any email correspondence. Emails</p>\n\n<p>without subject lines will not be read because of security issues.</p>\n\n<p></p>\n\n<p>Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror&#39;s to access solicitation documents posted. Prospective Offeror&#39;s should also register on the interested vendor list under <strong>SPMYM125Q0137</strong>. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.</p>\n\n<p></p>\n\n<p>All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the</p>\n\n<p>solicitation, except for awards to foreign vendors for work to be performed outside the United</p>\n\n<p>States. Lack of registration in the SAM database will make an offeror ineligible for award.</p>\n\n<p>Offerors may obtain information on registration and annual confirmation requirements by calling</p>\n\n<p>1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in</p>\n\n<p>accordance with the solicitation, dates and procedures. Please direct all questions regarding this</p>\n\n<p>requirement to <strong>Curtis Douglas </strong>at Curtis.douglas<strong>@dla.mil</strong><strong> </strong></p>\n\n<p></p>\n\n<p></p>","text":"The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)\n\nintends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically\n\nAcceptable (LPTA) Evaluation Factors for the item listed below. The required item is for\n\ncommercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart\n\n12.6, as supplemented with the additional information included in this notice.\n\nThe Contract Line Item (CLIN) is as follows:\n\nITEM NO.\n\nDESCRIPTION\n\nQTY\n\nU/I\n\nUNIT PRICE\n\nTOTAL\n\n0001\n\nFLUKE T5-1000\n\nELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER\n\nMODEL#: FLUKE T5-H5-1AC II KIT\n\nREF P/N 2PY98\n\n100\n\nEA\n\nDetermined by vendors\n\nDetermined by vendors\n\nT5-600/T5-1000\n\nElectrical Tester\n\nParts and Service\n\nThe tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the\n\nTS-600/TS-1000 Electrical Tester Instruction Sheet.\n\nTo order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)\n\nCanada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200\n\nJapan: +81-3-3434-0181\n\nSingapore: +65-738-5655\n\nAnywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.\n\nSpecifications\n\nAccuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:\n\n::!;([ % of reading] + [number of least significant digits])\n\nTemperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)\n\nSerial Numbers 79560000 and Above\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage\n\nBetween any Terminal and Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2\n\nTS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2\n\nMaximum Voltage\n\nBetween Current Fork and Earth Ground\n\nTS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\nO o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);\n\nO o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride\n\nShock, Vibration\n\n1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1\n\n1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nTS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nGeneral Specifications (continued)\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.\n\nEMC\n\nEN 61326\n\nCertifications\n\nCE <ti® ��S®IF,� C\n\nIn accordance with IEC 61010-1 54CJ\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\n~A\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n1000 0\n\n10\n\n:!(1o/o + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nTS-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n1.65 V de (nominal)\n\n<600 µA\n\nCAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nSerial Numbers 79559999 and Below\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage Between any Terminal\n\nand Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\n0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);\n\n0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride\n\nT5-600/T5-1000\n\nElectrical Tester\n\nGeneral Specifications (continued)\n\nShock, Vibration\n\n1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.\n\nSinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nT5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.\n\nEMC\n\nEN 50081-1, EN 50082-1\n\nCertifications\n\n( E c@us ct ®®\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\nA\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n10000\n\n10\n\n:!(1% + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nT5-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n2.4 V de (nominal)\n\n<600 µA\n\nCAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nCleaning the Tester\n\n�Warning\n\nTo avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.\n\nIf the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.\n\nThe requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.\n\nThe anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only.\n\nThe solicitation number is SPMYM125Q0137, and it is expected to be available on or about\n\n07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number\n\n(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails\n\nwithout subject lines will not be read because of security issues.\n\nPotential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.\n\nAll responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the\n\nsolicitation, except for awards to foreign vendors for work to be performed outside the United\n\nStates. Lack of registration in the SAM database will make an offeror ineligible for award.\n\nOfferors may obtain information on registration and annual confirmation requirements by calling\n\n1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in\n\naccordance with the solicitation, dates and procedures. Please direct all questions regarding this\n\nrequirement to Curtis Douglas at Curtis.douglas@dla.mil","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"SPMYM125Q0137","place_of_performance":{"zip":"23709","city":{"code":"64000","name":"Portsmouth"},"state":{"code":"VA","name":"Virginia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6625"},{"dates":{"posted":"2025-08-07","posted_at":"2025-08-07T17:48:07.740Z","created_at":"2025-07-25T14:07:28.546Z","modified_at":"2025-08-29T04:04:37.364Z","response_deadline":{"raw":"2025-08-13T12:00:00-04:00","utc":"2025-08-13T16:00:00Z","date":"2025-08-13","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/af8a37e1bb004629aa1bd31efb5d32d1/view"},"naics":{"codes":["334515"],"primary":"334515"},"title":"FLUKE T5-1000","agency":{"office":{"code":"SPMYM1","name":"DLA MARITIME - NORFOLK"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"23709-5000","city":"PORTSMOUTH","state":"VA","country":"USA"},"organization_id":"500032825","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-28","archive_type":"auto15"},"history":[{"index":6,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:55:15.964Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0776d04b773d42e29770ec399408efcc","solicitation_number":"SPMYM125Q0137","related_opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1"},{"index":4,"title":"FLUKE T5-1000","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-07T17:48:07.740Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"af8a37e1bb004629aa1bd31efb5d32d1","solicitation_number":"SPMYM125Q0137"}],"contacts":[{"name":"CURTIS DOUGLAS","role":"primary","email":"curtis.douglas@dla.mil","phone":"7572785058"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"af8a37e1bb004629aa1bd31efb5d32d1","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"af8a37e1bb004629aa1bd31efb5d32d1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-05T03:00:13.337537181Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"78fa0c652b8c4c9984853d4cdd87cb245cf5ced8144d08ef9e22bec7976c8c4e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-05T03:00:13.337537181Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)</p>\n\n<p>intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically</p>\n\n<p>Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for</p>\n\n<p>commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart</p>\n\n<p>12.6, as supplemented with the additional information included in this notice.</p>\n\n<p></p>\n\n<p>The Contract Line Item (CLIN) is as follows:</p>\n\n<p></p>\n\n<p><strong>ITEM NO.</strong></p>\n\n<p><strong><u>DESCRIPTION</u></strong></p>\n\n<p><strong><u>QTY</u></strong></p>\n\n<p><strong><u>U/I</u></strong></p>\n\n<p><strong><u>UNIT PRICE</u></strong></p>\n\n<p><strong><u>TOTAL</u></strong></p>\n\n<p>0001</p>\n\n<p>FLUKE T5-1000</p>\n\n<p>ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER</p>\n\n<p>MODEL#: FLUKE T5-H5-1AC II KIT</p>\n\n<p><u>REF P/N 2PY98</u></p>\n\n<p></p>\n\n<p>100</p>\n\n<p>EA</p>\n\n<p>Determined by vendors</p>\n\n<p>Determined by vendors</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><em>Parts and Service</em></p>\n\n<p>The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the</p>\n\n<p><em>TS-600/TS-1000 Electrical Tester Instruction Sheet.</em></p>\n\n<p>To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)</p>\n\n<p>Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200</p>\n\n<p>Japan: +81-3-3434-0181</p>\n\n<p>Singapore: +65-738-5655</p>\n\n<p>Anywhere in the world: +1-425-446-5500 Or, visit Fluke&#39;s Web site at www.fluke.com.</p>\n\n<p></p>\n\n<p><em>Specifications</em></p>\n\n<p>Accuracy is specified for one year after calibration, at 18 &deg;C to 28 &deg;C (64 &deg;F to 82 &deg;F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:</p>\n\n<p>::!;([ % of reading] + [number of least significant digits])</p>\n\n<p>Temperature coefficient of 0.1 x (specified accuracy)/ &deg;C for &lt;18 &deg;C or &gt;28 &deg;C (&lt;64.4 &deg;For &gt;82.4 &deg;F)</p>\n\n<p></p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79560000 </strong><strong><em>and Above</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between any Terminal and Earth Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2</p>\n\n<p>TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between Current Fork and Earth Ground</strong></p>\n\n<p>TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>O o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); o o/o to 75 %, 30 &deg;C to 40 &deg;C (86 &deg;F to 104 &deg;F);</p>\n\n<p>O o/o to 45 %, 40 &deg;C to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery Type and Life</strong></p>\n\n<p>AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride</p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at -10 &deg;C to + 50 &deg;C (14 &deg;F to 122 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-1</p>\n\n<p>1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p></p>\n\n<p><em>General</em><em> </em><em>Specifications</em><em> </em><em>(continued)</em></p>\n\n<p></p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 61326</p>\n\n<p><strong>Certifications</strong></p>\n\n<p><strong>CE</strong><strong>&nbsp;</strong>&lt;ti&reg;&nbsp;�<em>�</em><em>S</em>&reg;<em>IF,�</em><em>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </em><strong>C</strong></p>\n\n<p>In accordance with IEC 61010-1 54CJ</p>\n\n<p><strong><em>Resolution and Accuracy</em></strong></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>TS-600 Range</strong></p>\n\n<p><strong>TS-1000 Range</strong></p>\n\n<p><strong>Resolution</strong></p>\n\n<p><strong>Accuracy</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>~<strong>A</strong></p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>1000 0</p>\n\n<p>10</p>\n\n<p>:!(1o/o + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>Input Protection</p>\n\n<p>Input impedance (nomial</p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>TS-</strong><strong>1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>1.65 V de (nominal)</p>\n\n<p>&lt;600 <strong>&micro;A</strong></p>\n\n<p>CAT Ill protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT</strong><strong> </strong><strong>IV</strong><strong> </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79559999 </strong><strong><em>and Below</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage Between any Terminal</strong></p>\n\n<p><strong>and</strong><strong> </strong><strong>Earth</strong><strong> </strong><strong>Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>0 o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); 0 o/o to 75 %, 30 &deg;C to 40 &deg;c (86 &deg;F to 104 &deg;F);</p>\n\n<p>0 o/o to 45 %, 40 &deg;c to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery</strong><strong> </strong><strong>Type</strong><strong> </strong><strong>and</strong><strong> </strong><strong>Life</strong></p>\n\n<p>AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><em>General Specifications (continued)</em></strong></p>\n\n<p></p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at 15 &deg;C to 35 &deg;c (59 &deg;F to 95 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.</p>\n\n<p>Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 50081-1, EN 50082-1</p>\n\n<p><strong>Certifications</strong></p>\n\n<p>( <strong>E </strong>c@us <u>c</u>t &reg;&reg;</p>\n\n<p><em>Resolution and Accuracy</em></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>TS-600 Range</p>\n\n<p>TS-1000 Range</p>\n\n<p>Resolution</p>\n\n<p>Accuracy</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>A</p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>10000</p>\n\n<p>10</p>\n\n<p>:!(1% + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>Input Protection</strong></p>\n\n<p><strong>Input impedance (nomial</strong></p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>T5-1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>2.4 V de (nominal)</p>\n\n<p>&lt;600 &micro;A</p>\n\n<p><strong>CAT 111 </strong>protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT IV </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><em>Cleaning the Tester</em></p>\n\n<p><strong>�Warning</strong></p>\n\n<p><strong>To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester&#39;s case, never use solvents on the tester.</strong></p>\n\n<p>If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The requirement will be solicited as a total small business set aside</strong>. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.</p>\n\n<p></p>\n\n<p>The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. <strong>THE SOLICITATION IS NOT YET AVAILABLE</strong>.</p>\n\n<p></p>\n\n<p>The solicitation number is <strong>SPMYM125Q0137, </strong>and it is expected to be available on or about<strong> </strong></p>\n\n<p><strong>07 AUG 2025 </strong>and posted to SAM.gov, https://sam.gov/ Quotes will be due by <strong>12:00 PM EST </strong>on <strong>13 AUG 2025. </strong>Responses to the solicitation notice shall be emailed to the attention of <strong>Curtis Douglas </strong>at Curtis.douglas@dla.mil &nbsp;. Please make sure that the solicitation number</p>\n\n<p>(<strong>SPMYM125Q0137</strong>) is included in the subject line of any email correspondence. Emails</p>\n\n<p>without subject lines will not be read because of security issues.</p>\n\n<p></p>\n\n<p>Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror&#39;s to access solicitation documents posted. Prospective Offeror&#39;s should also register on the interested vendor list under <strong>SPMYM125Q0137</strong>. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.</p>\n\n<p></p>\n\n<p>All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the</p>\n\n<p>solicitation, except for awards to foreign vendors for work to be performed outside the United</p>\n\n<p>States. Lack of registration in the SAM database will make an offeror ineligible for award.</p>\n\n<p>Offerors may obtain information on registration and annual confirmation requirements by calling</p>\n\n<p>1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in</p>\n\n<p>accordance with the solicitation, dates and procedures. Please direct all questions regarding this</p>\n\n<p>requirement to <strong>Curtis Douglas </strong>at Curtis.douglas<strong>@dla.mil</strong><strong> </strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)\n\nintends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically\n\nAcceptable (LPTA) Evaluation Factors for the item listed below. The required item is for\n\ncommercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart\n\n12.6, as supplemented with the additional information included in this notice.\n\nThe Contract Line Item (CLIN) is as follows:\n\nITEM NO.\n\nDESCRIPTION\n\nQTY\n\nU/I\n\nUNIT PRICE\n\nTOTAL\n\n0001\n\nFLUKE T5-1000\n\nELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER\n\nMODEL#: FLUKE T5-H5-1AC II KIT\n\nREF P/N 2PY98\n\n100\n\nEA\n\nDetermined by vendors\n\nDetermined by vendors\n\nT5-600/T5-1000\n\nElectrical Tester\n\nParts and Service\n\nThe tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the\n\nTS-600/TS-1000 Electrical Tester Instruction Sheet.\n\nTo order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)\n\nCanada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200\n\nJapan: +81-3-3434-0181\n\nSingapore: +65-738-5655\n\nAnywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.\n\nSpecifications\n\nAccuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:\n\n::!;([ % of reading] + [number of least significant digits])\n\nTemperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)\n\nSerial Numbers 79560000 and Above\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage\n\nBetween any Terminal and Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2\n\nTS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2\n\nMaximum Voltage\n\nBetween Current Fork and Earth Ground\n\nTS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\nO o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);\n\nO o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride\n\nShock, Vibration\n\n1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1\n\n1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nTS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nGeneral Specifications (continued)\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.\n\nEMC\n\nEN 61326\n\nCertifications\n\nCE <ti® ��S®IF,� C\n\nIn accordance with IEC 61010-1 54CJ\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\n~A\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n1000 0\n\n10\n\n:!(1o/o + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nTS-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n1.65 V de (nominal)\n\n<600 µA\n\nCAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nSerial Numbers 79559999 and Below\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage Between any Terminal\n\nand Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\n0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);\n\n0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride\n\nT5-600/T5-1000\n\nElectrical Tester\n\nGeneral Specifications (continued)\n\nShock, Vibration\n\n1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.\n\nSinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nT5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.\n\nEMC\n\nEN 50081-1, EN 50082-1\n\nCertifications\n\n( E c@us ct ®®\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\nA\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n10000\n\n10\n\n:!(1% + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nT5-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n2.4 V de (nominal)\n\n<600 µA\n\nCAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nCleaning the Tester\n\n�Warning\n\nTo avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.\n\nIf the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.\n\nThe requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.\n\nThe anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. THE SOLICITATION IS NOT YET AVAILABLE.\n\nThe solicitation number is SPMYM125Q0137, and it is expected to be available on or about\n\n07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number\n\n(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails\n\nwithout subject lines will not be read because of security issues.\n\nPotential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.\n\nAll responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the\n\nsolicitation, except for awards to foreign vendors for work to be performed outside the United\n\nStates. Lack of registration in the SAM database will make an offeror ineligible for award.\n\nOfferors may obtain information on registration and annual confirmation requirements by calling\n\n1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in\n\naccordance with the solicitation, dates and procedures. Please direct all questions regarding this\n\nrequirement to Curtis Douglas at Curtis.douglas@dla.mil","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"SPMYM125Q0137","place_of_performance":{"zip":"23709","city":{"code":"64000","name":"Portsmouth"},"state":{"code":"VA","name":"Virginia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6625"}],"due_at":"2025-08-13T16:00:00Z","due_date":"2025-08-13","closes_at":"2025-08-13T16:00:00Z","awardable":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM1","office_name":"DLA MARITIME - NORFOLK","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"LEJDP6LSN5M7","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-11-05T03:14:11.819253Z","principal_notice_id":"af8a37e1bb004629aa1bd31efb5d32d1","description":{"text":"The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)\n\nintends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically\n\nAcceptable (LPTA) Evaluation Factors for the item listed below. The required item is for\n\ncommercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart\n\n12.6, as supplemented with the additional information included in this notice.\n\nThe Contract Line Item (CLIN) is as follows:\n\nITEM NO.\n\nDESCRIPTION\n\nQTY\n\nU/I\n\nUNIT PRICE\n\nTOTAL\n\n0001\n\nFLUKE T5-1000\n\nELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER\n\nMODEL#: FLUKE T5-H5-1AC II KIT\n\nREF P/N 2PY98\n\n100\n\nEA\n\nDetermined by vendors\n\nDetermined by vendors\n\nT5-600/T5-1000\n\nElectrical Tester\n\nParts and Service\n\nThe tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the\n\nTS-600/TS-1000 Electrical Tester Instruction Sheet.\n\nTo order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)\n\nCanada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200\n\nJapan: +81-3-3434-0181\n\nSingapore: +65-738-5655\n\nAnywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.\n\nSpecifications\n\nAccuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:\n\n::!;([ % of reading] + [number of least significant digits])\n\nTemperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)\n\nSerial Numbers 79560000 and Above\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage\n\nBetween any Terminal and Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2\n\nTS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2\n\nMaximum Voltage\n\nBetween Current Fork and Earth Ground\n\nTS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\nO o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);\n\nO o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride\n\nShock, Vibration\n\n1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1\n\n1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nTS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nGeneral Specifications (continued)\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.\n\nEMC\n\nEN 61326\n\nCertifications\n\nCE <ti® ��S®IF,� C\n\nIn accordance with IEC 61010-1 54CJ\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\n~A\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n1000 0\n\n10\n\n:!(1o/o + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nTS-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n1.65 V de (nominal)\n\n<600 µA\n\nCAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nSerial Numbers 79559999 and Below\n\nGeneral Specifications\n\nCalibration\n\nOne-year calibration cycle.\n\nMaximum Voltage Between any Terminal\n\nand Earth Ground\n\nTS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill\n\nTemperature\n\nOperating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)\n\nAltitude\n\nOperating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)\n\nRelative Humidity\n\n0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);\n\n0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)\n\nBattery Type and Life\n\nAA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride\n\nT5-600/T5-1000\n\nElectrical Tester\n\nGeneral Specifications (continued)\n\nShock, Vibration\n\n1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.\n\nSinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)\n\nSurge Protection\n\nT5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09\n\nEnclosure Rating\n\nIP 52 per IEC 60529, no vacuum applied\n\nRF Field Specification\n\n0.5 % full scale + (specified accuracy) at 3 V/m\n\nSafety\n\nComplies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.\n\nEMC\n\nEN 50081-1, EN 50082-1\n\nCertifications\n\n( E c@us ct ®®\n\nResolution and Accuracy\n\nFunction\n\nTS-600 Range\n\nTS-1000 Range\n\nResolution\n\nAccuracy\n\nv\n\n600 V rms\n\n1000 V rms\n\nlV\n\n:!(1.5 % + 2 digits)\n\nv\n\n600V\n\n1000V\n\nlV\n\n:!(1% + 1 digit)\n\nA\n\n100.0A\n\n100.0A\n\n0.lA\n\n:!(3 % + 3 digits)\n\nn\n\n10000\n\n10000\n\n10\n\n:!(1% + 2 digits)\n\nInput Characteristics\n\nFunction\n\nInput Protection\n\nInput impedance (nomial\n\nT5-600\n\nT5-1000\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF ac-coupled\n\nv\n\n600 V rms\n\n1000 V rms\n\n1 MO, <100 pF\n\nn\n\n600 V rms\n\n1000 V rms\n\nn\n\nOpen Circuit Test Voltage\n\nShort Circuit Current\n\n2.4 V de (nominal)\n\n<600 µA\n\nCAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.\n\nCAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.\n\nCleaning the Tester\n\n�Warning\n\nTo avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.\n\nIf the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.\n\nThe requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.\n\nThe anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. THE SOLICITATION IS NOT YET AVAILABLE.\n\nThe solicitation number is SPMYM125Q0137, and it is expected to be available on or about\n\n07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number\n\n(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails\n\nwithout subject lines will not be read because of security issues.\n\nPotential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.\n\nAll responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the\n\nsolicitation, except for awards to foreign vendors for work to be performed outside the United\n\nStates. Lack of registration in the SAM database will make an offeror ineligible for award.\n\nOfferors may obtain information on registration and annual confirmation requirements by calling\n\n1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in\n\naccordance with the solicitation, dates and procedures. Please direct all questions regarding this\n\nrequirement to Curtis Douglas at Curtis.douglas@dla.mil","html":"<p>The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY)</p>\n\n<p>intends to award a Firm Fixed Price (FFP) Single Award Contract as Lowest Price Technically</p>\n\n<p>Acceptable (LPTA) Evaluation Factors for the item listed below. The required item is for</p>\n\n<p>commercial item prepared in accordance with the information in FAR Part 13 and FAR Subpart</p>\n\n<p>12.6, as supplemented with the additional information included in this notice.</p>\n\n<p></p>\n\n<p>The Contract Line Item (CLIN) is as follows:</p>\n\n<p></p>\n\n<p><strong>ITEM NO.</strong></p>\n\n<p><strong><u>DESCRIPTION</u></strong></p>\n\n<p><strong><u>QTY</u></strong></p>\n\n<p><strong><u>U/I</u></strong></p>\n\n<p><strong><u>UNIT PRICE</u></strong></p>\n\n<p><strong><u>TOTAL</u></strong></p>\n\n<p>0001</p>\n\n<p>FLUKE T5-1000</p>\n\n<p>ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER</p>\n\n<p>MODEL#: FLUKE T5-H5-1AC II KIT</p>\n\n<p><u>REF P/N 2PY98</u></p>\n\n<p></p>\n\n<p>100</p>\n\n<p>EA</p>\n\n<p>Determined by vendors</p>\n\n<p>Determined by vendors</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><em>Parts and Service</em></p>\n\n<p>The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the</p>\n\n<p><em>TS-600/TS-1000 Electrical Tester Instruction Sheet.</em></p>\n\n<p>To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)</p>\n\n<p>Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200</p>\n\n<p>Japan: +81-3-3434-0181</p>\n\n<p>Singapore: +65-738-5655</p>\n\n<p>Anywhere in the world: +1-425-446-5500 Or, visit Fluke&#39;s Web site at www.fluke.com.</p>\n\n<p></p>\n\n<p><em>Specifications</em></p>\n\n<p>Accuracy is specified for one year after calibration, at 18 &deg;C to 28 &deg;C (64 &deg;F to 82 &deg;F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:</p>\n\n<p>::!;([ % of reading] + [number of least significant digits])</p>\n\n<p>Temperature coefficient of 0.1 x (specified accuracy)/ &deg;C for &lt;18 &deg;C or &gt;28 &deg;C (&lt;64.4 &deg;For &gt;82.4 &deg;F)</p>\n\n<p></p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79560000 </strong><strong><em>and Above</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between any Terminal and Earth Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2</p>\n\n<p>TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2</p>\n\n<p><strong>Maximum Voltage</strong></p>\n\n<p><strong>Between Current Fork and Earth Ground</strong></p>\n\n<p>TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>O o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); o o/o to 75 %, 30 &deg;C to 40 &deg;C (86 &deg;F to 104 &deg;F);</p>\n\n<p>O o/o to 45 %, 40 &deg;C to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery Type and Life</strong></p>\n\n<p>AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride</p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at -10 &deg;C to + 50 &deg;C (14 &deg;F to 122 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-1</p>\n\n<p>1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p></p>\n\n<p><em>General</em><em> </em><em>Specifications</em><em> </em><em>(continued)</em></p>\n\n<p></p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 61326</p>\n\n<p><strong>Certifications</strong></p>\n\n<p><strong>CE</strong><strong>&nbsp;</strong>&lt;ti&reg;&nbsp;�<em>�</em><em>S</em>&reg;<em>IF,�</em><em>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </em><strong>C</strong></p>\n\n<p>In accordance with IEC 61010-1 54CJ</p>\n\n<p><strong><em>Resolution and Accuracy</em></strong></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>TS-600 Range</strong></p>\n\n<p><strong>TS-1000 Range</strong></p>\n\n<p><strong>Resolution</strong></p>\n\n<p><strong>Accuracy</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>~<strong>A</strong></p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>1000 0</p>\n\n<p>10</p>\n\n<p>:!(1o/o + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>Input Protection</p>\n\n<p>Input impedance (nomial</p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>TS-</strong><strong>1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>1.65 V de (nominal)</p>\n\n<p>&lt;600 <strong>&micro;A</strong></p>\n\n<p>CAT Ill protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT</strong><strong> </strong><strong>IV</strong><strong> </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><strong><em>Serial Numbers </em></strong><strong>79559999 </strong><strong><em>and Below</em></strong></p>\n\n<p><strong><em>General Specifications</em></strong></p>\n\n<p><strong>Calibration</strong></p>\n\n<p>One-year calibration cycle.</p>\n\n<p><strong>Maximum Voltage Between any Terminal</strong></p>\n\n<p><strong>and</strong><strong> </strong><strong>Earth</strong><strong> </strong><strong>Ground</strong></p>\n\n<p>TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill</p>\n\n<p><strong>Temperature</strong></p>\n\n<p>Operating: -10 &deg;C to +50 &deg;C (14 &deg;F to 122 &deg;F); Storage: -30 &deg;C to +60 &deg;C (-22 &deg;F to +140 &deg;F)</p>\n\n<p><strong>Altitude</strong></p>\n\n<p>Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)</p>\n\n<p><strong>Relative Humidity</strong></p>\n\n<p>0 o/o to 95 %, 5 &deg;C to 30 &deg;C (41 &deg;F to 86&deg;F); 0 o/o to 75 %, 30 &deg;C to 40 &deg;c (86 &deg;F to 104 &deg;F);</p>\n\n<p>0 o/o to 45 %, 40 &deg;c to 50 &deg;C (104 &deg;F to 122 &deg;F)</p>\n\n<p><strong>Battery</strong><strong> </strong><strong>Type</strong><strong> </strong><strong>and</strong><strong> </strong><strong>Life</strong></p>\n\n<p>AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride</p>\n\n<p></p>\n\n<p><strong><em>T5-600/T5-1000</em></strong></p>\n\n<p><strong><em>Electrical Tester</em></strong></p>\n\n<p></p>\n\n<p><br />\n<br />\n<br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><em>General Specifications (continued)</em></strong></p>\n\n<p></p>\n\n<p><strong>Shock, Vibration</strong></p>\n\n<p>1 m drop at 15 &deg;C to 35 &deg;c (59 &deg;F to 95 &deg;F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.</p>\n\n<p>Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)</p>\n\n<p><strong>Surge Protection</strong></p>\n\n<p>T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09</p>\n\n<p><strong>Enclosure Rating</strong></p>\n\n<p>IP 52 per IEC 60529, no vacuum applied</p>\n\n<p><strong>RF Field Specification</strong></p>\n\n<p>0.5 % full scale + (specified accuracy) at 3 V/m</p>\n\n<p><strong>Safety</strong></p>\n\n<p>Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.</p>\n\n<p><strong>EMC</strong></p>\n\n<p>EN 50081-1, EN 50082-1</p>\n\n<p><strong>Certifications</strong></p>\n\n<p>( <strong>E </strong>c@us <u>c</u>t &reg;&reg;</p>\n\n<p><em>Resolution and Accuracy</em></p>\n\n<p></p>\n\n<p>Function</p>\n\n<p>TS-600 Range</p>\n\n<p>TS-1000 Range</p>\n\n<p>Resolution</p>\n\n<p>Accuracy</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>lV</p>\n\n<p>:!(1.5 % + 2 digits)</p>\n\n<p>v</p>\n\n<p>600V</p>\n\n<p>1000V</p>\n\n<p>lV</p>\n\n<p>:!(1% + 1 digit)</p>\n\n<p>A</p>\n\n<p>100.0A</p>\n\n<p>100.0A</p>\n\n<p>0.lA</p>\n\n<p>:!(3 % + 3 digits)</p>\n\n<p>n</p>\n\n<p>10000</p>\n\n<p>10000</p>\n\n<p>10</p>\n\n<p>:!(1% + 2 digits)</p>\n\n<p><em>Input Characteristics</em></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Function</strong></p>\n\n<p><strong>Input Protection</strong></p>\n\n<p><strong>Input impedance (nomial</strong></p>\n\n<p><strong>T5-600</strong></p>\n\n<p><strong>T5-1000</strong></p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF ac-coupled</p>\n\n<p>v</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p>1 MO, &lt;100 pF</p>\n\n<p>n</p>\n\n<p>600 V rms</p>\n\n<p>1000 V rms</p>\n\n<p></p>\n\n<p></p>\n\n<p>n</p>\n\n<p><strong>Open Circuit Test Voltage</strong></p>\n\n<p><strong>Short Circuit Current</strong></p>\n\n<p>2.4 V de (nominal)</p>\n\n<p>&lt;600 &micro;A</p>\n\n<p><strong>CAT 111 </strong>protects against transients in a <em>fixed equipment installation </em>such as a distribution panel, and lighting systems in large buildings.</p>\n\n<p><strong>CAT IV </strong>protects against transients from a <em>primary supply </em>such as an electricity meter or an overhead or underground utility service.</p>\n\n<p><em>Cleaning the Tester</em></p>\n\n<p><strong>�Warning</strong></p>\n\n<p><strong>To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester&#39;s case, never use solvents on the tester.</strong></p>\n\n<p>If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The requirement will be solicited as a total small business set aside</strong>. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.</p>\n\n<p></p>\n\n<p>The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. <strong>THE SOLICITATION IS NOT YET AVAILABLE</strong>.</p>\n\n<p></p>\n\n<p>The solicitation number is <strong>SPMYM125Q0137, </strong>and it is expected to be available on or about<strong> </strong></p>\n\n<p><strong>07 AUG 2025 </strong>and posted to SAM.gov, https://sam.gov/ Quotes will be due by <strong>12:00 PM EST </strong>on <strong>13 AUG 2025. </strong>Responses to the solicitation notice shall be emailed to the attention of <strong>Curtis Douglas </strong>at Curtis.douglas@dla.mil &nbsp;. Please make sure that the solicitation number</p>\n\n<p>(<strong>SPMYM125Q0137</strong>) is included in the subject line of any email correspondence. Emails</p>\n\n<p>without subject lines will not be read because of security issues.</p>\n\n<p></p>\n\n<p>Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror&#39;s to access solicitation documents posted. Prospective Offeror&#39;s should also register on the interested vendor list under <strong>SPMYM125Q0137</strong>. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.</p>\n\n<p></p>\n\n<p>All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the</p>\n\n<p>solicitation, except for awards to foreign vendors for work to be performed outside the United</p>\n\n<p>States. Lack of registration in the SAM database will make an offeror ineligible for award.</p>\n\n<p>Offerors may obtain information on registration and annual confirmation requirements by calling</p>\n\n<p>1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in</p>\n\n<p>accordance with the solicitation, dates and procedures. Please direct all questions regarding this</p>\n\n<p>requirement to <strong>Curtis Douglas </strong>at Curtis.douglas<strong>@dla.mil</strong><strong> </strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"CURTIS DOUGLAS","role":"primary","email":"curtis.douglas@dla.mil","phone":"7572785058"}],"place_of_performance":{"zip":"23709","city":{"code":"64000","name":"Portsmouth"},"state":{"code":"VA","name":"Virginia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"23709-5000","city":"PORTSMOUTH","state":"VA","country":"USA"},"naics_codes":["334515"],"award":null,"attachments":[{"resource_id":"4fc06dd6cfbc4b1b915f0f0c9e0be9a9","name":"KO approved Solicitation SPMYM125Q0137 JML 51182700.pdf","kind":"file","mime_type":".pdf","size_bytes":1393858,"posted_at":"2025-08-07T17:55:15.964Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4fc06dd6cfbc4b1b915f0f0c9e0be9a9/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_SPMYM125P1414_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_SPMYM125P1414_9700_-NONE-_-NONE-/","piid":"SPMYM125P1414","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"LEJDP6LSN5M7","recipient_name":"SUPPLY SOLUTIONS INTERNATIONAL, INC.","recipient_uei":"LEJDP6LSN5M7","recipient_cage":"8FBX3","recipient_city":"TEMECULA","recipient_state":"CA","sub_name":"Defense Logistics Agency","office_name":"DLA MARITIME - NORFOLK","office_key":"o-SPMYM1","first_action_date":"2025-08-25","last_action_date":"2025-09-11","actions":2,"obligated":"27700.00","current_total_value":"27700.00","potential_total_value":"27700.00","naics":"334515","psc":"6625","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":2,"description":"N4215851182700 FLUKE T5","method":"solicitation","confidence":"high","evidence":["solicitation number SPMYM125Q0137 equals the FPDS solicitation identifier","same awarding office SPMYM1"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"SPMYM127Q4015","latest_notice_id":"0ad8b216ecda4ff286822f1b46ac6c97","title":"TRIPPLE CABLE SET","solicitation_number":"SPMYM127Q4015","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T13:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM1","office_name":"DLA MARITIME - NORFOLK","naics":"332811","psc":"3424","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPMYM127Q4016","latest_notice_id":"992111b1ed7b46ec8b8b38b92c6a89ad","title":"HOSE ASSEMBLY, \"LAY-FLAT\" WATER DISCHARGE","solicitation_number":"SPMYM127Q4016","notice_type":"k","first_type":"k","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-01T13:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM1","office_name":"DLA MARITIME - NORFOLK","naics":"326220","psc":"4720","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"SPMYM127Q4014","latest_notice_id":"fc5be9b1dfea4703b84da149adf817e8","title":"SCAFFPADS","solicitation_number":"SPMYM127Q4014","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM1","office_name":"DLA MARITIME - NORFOLK","naics":"314999","psc":"5680","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPMYM127Q4013","latest_notice_id":"1cbc81c70286466e8d026de3b50597f2","title":"Retrofit Kit ASSY & Related Parts","solicitation_number":"SPMYM127Q4013","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM1","office_name":"DLA MARITIME - NORFOLK","naics":"332216","psc":"6670","set_aside":"SBA","state":"VA","county":"51740","county_name":"City of Portsmouth","city":"5164000","city_name":"Portsmouth","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N6833526RFPREQBL310000026","latest_notice_id":"238ef98fbffe40dcb3f4c0cecc2f707e","title":"Request for Information Authorized Distributors/Resellers of Keysight Technologies Products","solicitation_number":"N68335-26-RFPREQ-BL31000-0026","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-26T22:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N68335","office_name":"NAVAIR WARFARE CTR AIRCRAFT DIV","naics":"334515","psc":"6625","set_aside":null,"state":"MS","county":"28047","county_name":"Harrison County","city":"2829700","city_name":"Gulfport","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-11T05:50:21.226923Z"},{"key":"N0010426QNF12","latest_notice_id":"6983ef64eae84b6789638a6497ae12c9","title":"SERVER,AUTOMATIC DA","solicitation_number":"N0010426QNF12","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-10-21","notices":3,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"334515","psc":"7E20","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7E20)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"},{"key":"N0010426QNE27","latest_notice_id":"ea539f6613554537b19cefd8bfd54ab8","title":"SERVER,AUTOMATIC DA","solicitation_number":"N0010426QNE27","notice_type":"o","first_type":"o","first_posted":"2026-08-07","last_posted":"2026-10-21","notices":4,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"334515","psc":"7E20","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7E20)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open_total":45,"indexable":false}