Solicitation, indian small business economic enterprise, first published as presolicitation
HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT
IHS1512570
Indian Health Service, Indian Health Service. Commercial and Institutional Building Construction.
Response deadline
July 7, 2025 at 6:00 PM EDT
Closed 506 days ago. Posted June 5, 2025, first published May 19, 2025. Scheduled to archive July 22, 2025.
Get the next one like this from Indian Health Service by email, the day it is posted.Find my opportunities
This one closed in 2025
195 like it are open now in commercial and institutional building construction
- FY27 Design-Build (DB) Single Award Task Order Contract (SATOC) Baden-Wurttemberg Rheinland-Pfalz
Department of the Army, W2SD Endist Europe
Sources soughtNAICS 236220Outside the USW912GB271CUBDue todayNov 25 - P233 AIR TRAFFIC CONTROL TOWER AND FLIGHT SIMULATOR TRAINING FACILITY
Department of the Navy, Navfacsyscom Southeast
Due todayNov 25 - Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information
Department of Veterans Affairs, 260-Network Contract Office 20
SolicitationSDVOSBNAICS 236220Boise City, ID36C26027R0002-0006Due todayNov 25
All 195 open in commercial and institutional building construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- Indian small business economic enterprise. Reserved under the Buy Indian Act for Indian small business economic enterprises. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. Open Indian small business opportunities
- Time to respond
- Bidders had 32 days from the day the solicitation was posted, June 5, 2025, to the deadline. The deadline moved once: it was first June 3, 2025 and ended as July 7, 2025.
- Before the solicitation
- The agency published a presolicitation on May 19, 2025, 17 days before the solicitation.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
1. PURPOSE OF THE PROJECT
The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the
replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and
transoms for all (4) vestibules.
2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS
• The interior and exterior doors shall be 42” wide to accommodate gurneys used by EMS and wide
wheelchairs.
• All exterior doors shall have a full window/daylight panel measuring approximately 34”x 69” and be
UL
752 Level 5 bullet resistant glazing or equivalent.
• All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet
resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door,
transom, sidelights) shall be ¼” tempered glass.
• The northwest corner of the building has an existing metal and glass vestibule protruding from the
building measuring approximately 36” out from the building and 64” wide. The (2) panes of glass on
the exterior vestibule measure approximately 30”x 90”. These panes of glass shall be replaced with
UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse
exterior door measuring 42”x 84”. The transom window shall be 4”x 42” and shall be 1/4” tempered
glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway,
shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 8”
x 100” and a transom measuring approximately 16” x 42”.
• The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door
measuring 42”x 84” with (2) sidelights measuring approximately 14”x 100”and a transom measuring
approximately 16”x 42”. The interior door shall be a left hand reverse door measuring 42”x 84” with
(2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.
• The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall
have a right hand reverse exterior door measuring 42”x 84” with (1) sidelight measuring approximately
13”x 101” and a transom measuring approximately 17”x 42”. The interior door shall be a right hand
reverse door measuring 42”x 84” with (2) sidelights measuring approximately 5”x 100” and a transom
measuring approximately 16”x 42”.
• The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42”x 84”
with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 17”x
42”. The interior door shall be a left hand reverse door measuring 42”x 84” with (2) sidelights
measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.
• Contractor shall coordinate with the facility’s existing Secure Access Control provider (Cam-Dex
Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes
back to original locations or as close as possible for all replaced doors. Card readers and strikes shall
be in good working order before starting on the next exterior door for security purposes and to justify
egress.
• Door and window frames shall be black anodized aluminum and match the fit and finish of the current
frames.
• All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar,
heavy-duty continuous hinge with threshold, and lock keyed to the facility master key.
• All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when
viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior,
automatic sliding door entrance. Tinting shall be minimum of 35% shade.
• All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover
persons entering and exiting the building. The awnings shall be black anodized aluminum (or
equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more
than 36” away from the building. All awnings shall be equipped with gutters and downspouts to divert
water away from the building.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 75H71125B00001 - Haskell Vestibule Update.pdf3.7 MB, June 5, 2025
- IHS1512570 PreSolicitation Notice.pdf146 KB, May 19, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 19, 2025
Presolicitation
Due June 3, 2025 at 3:00 PM EDT. SAM.gov, notice 5adff37bb098484b9538c795fd5fa7c5
2 revisions on SAM
- June 5, 2025: publish, solicitation
- May 19, 2025: publish, presolicitation
June 5, 2025
Solicitation, originally presolicitation
Due July 7, 2025 at 6:00 PM EDT. SAM.gov, notice bed716b864a2457aa9335cdf4d7320ce
2 revisions on SAM
- June 5, 2025: publish, solicitation
- May 19, 2025: publish, presolicitation