Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,733 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Solicitation, indian small business economic enterprise, first published as presolicitation

HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT

IHS1512570

Indian Health Service, Indian Health Service. Commercial and Institutional Building Construction.

Response deadline

July 7, 2025 at 6:00 PM EDT

Closed 506 days ago. Posted June 5, 2025, first published May 19, 2025. Scheduled to archive July 22, 2025.

Get the next one like this from Indian Health Service by email, the day it is posted.Find my opportunities

This one closed in 2025

195 like it are open now in commercial and institutional building construction

All 195 open in commercial and institutional building construction

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
Who may compete
Indian small business economic enterprise. Reserved under the Buy Indian Act for Indian small business economic enterprises. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. Open Indian small business opportunities
Time to respond
Bidders had 32 days from the day the solicitation was posted, June 5, 2025, to the deadline. The deadline moved once: it was first June 3, 2025 and ended as July 7, 2025.
Before the solicitation
The agency published a presolicitation on May 19, 2025, 17 days before the solicitation.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

1. PURPOSE OF THE PROJECT
The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the
replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and
transoms for all (4) vestibules.
2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS
• The interior and exterior doors shall be 42” wide to accommodate gurneys used by EMS and wide
wheelchairs.
• All exterior doors shall have a full window/daylight panel measuring approximately 34”x 69” and be
UL
752 Level 5 bullet resistant glazing or equivalent.
• All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet
resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door,
transom, sidelights) shall be ¼” tempered glass.
• The northwest corner of the building has an existing metal and glass vestibule protruding from the
building measuring approximately 36” out from the building and 64” wide. The (2) panes of glass on
the exterior vestibule measure approximately 30”x 90”. These panes of glass shall be replaced with
UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse
exterior door measuring 42”x 84”. The transom window shall be 4”x 42” and shall be 1/4” tempered
glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway,
shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 8”
x 100” and a transom measuring approximately 16” x 42”.
• The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door
measuring 42”x 84” with (2) sidelights measuring approximately 14”x 100”and a transom measuring
approximately 16”x 42”. The interior door shall be a left hand reverse door measuring 42”x 84” with
(2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.
• The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall
have a right hand reverse exterior door measuring 42”x 84” with (1) sidelight measuring approximately
13”x 101” and a transom measuring approximately 17”x 42”. The interior door shall be a right hand
reverse door measuring 42”x 84” with (2) sidelights measuring approximately 5”x 100” and a transom
measuring approximately 16”x 42”.
• The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42”x 84”
with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 17”x
42”. The interior door shall be a left hand reverse door measuring 42”x 84” with (2) sidelights
measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”.
• Contractor shall coordinate with the facility’s existing Secure Access Control provider (Cam-Dex
Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes
back to original locations or as close as possible for all replaced doors. Card readers and strikes shall
be in good working order before starting on the next exterior door for security purposes and to justify
egress.
• Door and window frames shall be black anodized aluminum and match the fit and finish of the current
frames.
• All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar,
heavy-duty continuous hinge with threshold, and lock keyed to the facility master key.
• All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when
viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior,
automatic sliding door entrance. Tinting shall be minimum of 35% shade.
• All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover
persons entering and exiting the building. The awnings shall be black anodized aluminum (or
equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more
than 36” away from the building. All awnings shall be equipped with gutters and downspouts to divert
water away from the building.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. May 19, 2025

    Presolicitation

    Due June 3, 2025 at 3:00 PM EDT. SAM.gov, notice 5adff37bb098484b9538c795fd5fa7c5

    2 revisions on SAM
    • June 5, 2025: publish, solicitation
    • May 19, 2025: publish, presolicitation
  2. June 5, 2025

    Solicitation, originally presolicitation

    Due July 7, 2025 at 6:00 PM EDT. SAM.gov, notice bed716b864a2457aa9335cdf4d7320ce

    2 revisions on SAM
    • June 5, 2025: publish, solicitation
    • May 19, 2025: publish, presolicitation

Points of contact