# HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT

Canonical: https://sealedbidder.com/opportunities/ihs1512570

- Solicitation number: IHS1512570
- Notice type: Solicitation (first published as presolicitation)
- Status: Closed. Deadline was July 7, 2025 at 6:00 PM EDT
- Department: Department of Health and Human Services
- Agency: Indian Health Service
- Contracting office: Indian Health Service (75H711)
- NAICS: 236220 Commercial and Institutional Building Construction
- Product or service code: Z2DA Repair Or Alteration Of Hospitals And Infirmaries
- Set-aside: Indian small business economic enterprise
- Small business size standard: $45 million in average annual receipts (13 CFR 121.201, NAICS 236220)
- Place of performance: Lawrence, Kansas
- County: Douglas County (FIPS 20045). https://sealedbidder.com/counties/douglas-county-ks-20045
- City: Lawrence. https://sealedbidder.com/cities/lawrence-ks-2038900
- First posted: May 19, 2025
- Last posted: June 5, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/bed716b864a2457aa9335cdf4d7320ce/view

## Reading this notice

- Kind of notice: Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline.
- Who may compete: Indian small business economic enterprise. Reserved under the Buy Indian Act for Indian small business economic enterprises. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates.
- Time to respond: Bidders had 32 days from the day the solicitation was posted, June 5, 2025, to the deadline. The deadline moved once: it was first June 3, 2025 and ended as July 7, 2025.
- Before the solicitation: The agency published a presolicitation on May 19, 2025, 17 days before the solicitation.

## Description

1. PURPOSE OF THE PROJECT

The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the

replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and

transoms for all (4) vestibules.

2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS

&bull; The interior and exterior doors shall be 42&rdquo; wide to accommodate gurneys used by EMS and wide

wheelchairs.

&bull; All exterior doors shall have a full window/daylight panel measuring approximately 34&rdquo;x 69&rdquo; and be

UL

752 Level 5 bullet resistant glazing or equivalent.

&bull; All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet

resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door,

transom, sidelights) shall be &frac14;&rdquo; tempered glass.

&bull; The northwest corner of the building has an existing metal and glass vestibule protruding from the

building measuring approximately 36&rdquo; out from the building and 64&rdquo; wide. The (2) panes of glass on

the exterior vestibule measure approximately 30&rdquo;x 90&rdquo;. These panes of glass shall be replaced with

UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse

exterior door measuring 42&rdquo;x 84&rdquo;. The transom window shall be 4&rdquo;x 42&rdquo; and shall be 1/4&rdquo; tempered

glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway,

shall be a left hand reverse door measuring 42&rdquo;x 84&rdquo; with (2) sidelights measuring approximately 8&rdquo;

x 100&rdquo; and a transom measuring approximately 16&rdquo; x 42&rdquo;.

&bull; The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door

measuring 42&rdquo;x 84&rdquo; with (2) sidelights measuring approximately 14&rdquo;x 100&rdquo;and a transom measuring

approximately 16&rdquo;x 42&rdquo;. The interior door shall be a left hand reverse door measuring 42&rdquo;x 84&rdquo; with

(2) sidelights measuring approximately 15&rdquo;x 100&rdquo; and a transom measuring approximately 16&rdquo;x 42&rdquo;.

&bull; The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall

have a right hand reverse exterior door measuring 42&rdquo;x 84&rdquo; with (1) sidelight measuring approximately

13&rdquo;x 101&rdquo; and a transom measuring approximately 17&rdquo;x 42&rdquo;. The interior door shall be a right hand

reverse door measuring 42&rdquo;x 84&rdquo; with (2) sidelights measuring approximately 5&rdquo;x 100&rdquo; and a transom

measuring approximately 16&rdquo;x 42&rdquo;.

&bull; The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42&rdquo;x 84&rdquo;

with (2) sidelights measuring approximately 15&rdquo;x 100&rdquo; and a transom measuring approximately 17&rdquo;x

42&rdquo;. The interior door shall be a left hand reverse door measuring 42&rdquo;x 84&rdquo; with (2) sidelights

measuring approximately 15&rdquo;x 100&rdquo; and a transom measuring approximately 16&rdquo;x 42&rdquo;.

&bull; Contractor shall coordinate with the facility&rsquo;s existing Secure Access Control provider (Cam-Dex

Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes

back to original locations or as close as possible for all replaced doors. Card readers and strikes shall

be in good working order before starting on the next exterior door for security purposes and to justify

egress.

&bull; Door and window frames shall be black anodized aluminum and match the fit and finish of the current

frames.

&bull; All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar,

heavy-duty continuous hinge with threshold, and lock keyed to the facility master key.

&bull; All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when

viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior,

automatic sliding door entrance. Tinting shall be minimum of 35% shade.

&bull; All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover

persons entering and exiting the building. The awnings shall be black anodized aluminum (or

equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more

than 36&rdquo; away from the building. All awnings shall be equipped with gutters and downspouts to divert

water away from the building.

## Attachments

- [75H71125B00001 - Haskell Vestibule Update.pdf](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/65801fb0e4de4739ade155399d7780c4/download)
- [IHS1512570 PreSolicitation Notice.pdf](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2b8040663b544ff59cd6742d5b940575/download)

## Open now in the same industry

192 open in NAICS 236220.

- Chesapeake and Delaware (C and D) Canal Building Replacement Project. (W912BU27RA009), due November 25, 2026 at 2:00 PM EST. https://sealedbidder.com/opportunities/w912bu27ra009
- P758 Machinery Control Development Center, Philadelphia Navy Yard, PA (N4008527R0047), due November 25, 2026 at 2:00 PM EST. https://sealedbidder.com/opportunities/n4008527r0047
- SABER FY 27-32 (FA860126R0019), due November 25, 2026 at 2:00 PM EST. https://sealedbidder.com/opportunities/fa860126r0019

## Publications

- May 19, 2025: Presolicitation, due June 3, 2025 at 3:00 PM EDT. Notice 5adff37bb098484b9538c795fd5fa7c5. https://sam.gov/workspace/contract/opp/5adff37bb098484b9538c795fd5fa7c5/view
- June 5, 2025: Solicitation, due July 7, 2025 at 6:00 PM EDT. Notice bed716b864a2457aa9335cdf4d7320ce. https://sam.gov/workspace/contract/opp/bed716b864a2457aa9335cdf4d7320ce/view

## Points of contact

- Mary Ann Yocham, MaryAnn.Yocham@ihs.gov, 4059516043

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/ihs1512570.