Presolicitation, total small business set-aside
RFI-Recommendation or Suggestion for a Replacement AC Unit
FA3016FY2620TONAC
Department of the Air Force, FA3016 502 Cons CL. Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers.
Response deadline
February 20, 2026 at 5:00 PM EST
Closed 279 days ago. Posted February 12, 2026. Scheduled to archive March 7, 2026.
Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 423730 (warm air heating and air-conditioning equipment and supplies merchant wholesalers), means no more than 175 employees, counted with affiliates. Open Small business opportunities
- What comes next
- No solicitation was published under this number after the presolicitation of February 12, 2026. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.
The replacement needs to be compatible with the following specifications:
Outdoor Unit (Condenser):
Nominal Capacity: 20 TON (240,000 BTU/h)
Voltage: 208/230V – 3 Phase – 60HZ
Refrigerant TYPE: R-22
Compressors: 2-Stage (Dual) Scroll Compressors
Fans: 2
Efficiency: Up to 11.0 EER / 14.8 IEER
Dimensions: ~50.4” H x 103.4” W x 54.3” D
Weight: 1133lbs
Inside Unit (Air Handler):
Nominal Capacity: 20 TON (240,000 BTU/h)
Fan Motor Horsepower: 3HP
Nominal Air Flow: 8000 CFM
Electrical: 208/230 Volt, 3-Phrase, 60Hz
Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)
Commercial Heat Element Kit
For Air Handler Unit: 20 TON
Voltage: 240Volts – 3 Phase – 60HZ
240 Volts, 3 Phrase
Heating Capacity 19.1W
Total Amps: 46 AMPS
The Statement Of Need and pictures of the current unit are attached for reference.
Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.
We kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Statement of NEED 20 TON Split AC System.docx50 KB, February 12, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 12, 2026
Presolicitation
Due February 20, 2026 at 5:00 PM EST. SAM.gov, notice a4cfc7adb3be4e59843b8f8c8888d63d
1 revision on SAM
- February 12, 2026: publish, presolicitation
Points of contact
- Ernest Suttonernest.sutton@us.af.mil
- Erika Turnererika.turner.1@us.af.mil