{"canonical":"https://sealedbidder.com/opportunities/fa3016fy2620tonac","key":"FA3016FY2620TONAC","url":"https://sealedbidder.com/opportunities/fa3016fy2620tonac","title":"RFI-Recommendation or Suggestion for a Replacement AC Unit","solicitation_number":"FA3016FY2620TONAC","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-20T22:00:00Z","first_posted":"2026-02-12","last_posted":"2026-02-12","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA3016 502 CONS CL","naics":"423730","psc":"4120","set_aside":"SBA","place_state":"TX","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":"4865000","place_city_name":"San Antonio","winner":null,"award_amount":null,"publications":[{"notice_id":"a4cfc7adb3be4e59843b8f8c8888d63d","title":"RFI-Recommendation or Suggestion for a Replacement AC Unit","solicitation_number":"FA3016FY2620TONAC","notice_type":"p","base_type":"p","posted":"2026-02-12","posted_at":"2026-02-12T16:57:50.478Z","due_at":"2026-02-20T22:00:00Z","due_date":"2026-02-20","cancelled":false,"archived":true,"archive_date":"2026-03-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a4cfc7adb3be4e59843b8f8c8888d63d/view","enriched":true,"history":[{"index":3,"title":"RFI-Recommendation or Suggestion for a Replacement AC Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-12T16:57:50.478Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a4cfc7adb3be4e59843b8f8c8888d63d","solicitation_number":"FA3016FY2620TONAC"}]}],"latest_notice_id":"a4cfc7adb3be4e59843b8f8c8888d63d","first_type":"p","notices":[{"dates":{"posted":"2026-02-12","posted_at":"2026-02-12T16:57:50.478Z","created_at":"2026-02-12T15:31:44.560Z","modified_at":"2026-03-08T04:55:43.778Z","response_deadline":{"raw":"2026-02-20T16:00:00-06:00","utc":"2026-02-20T22:00:00Z","date":"2026-02-20","time":"16:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a4cfc7adb3be4e59843b8f8c8888d63d/view"},"naics":{"codes":["423730"],"primary":"423730"},"title":"RFI-Recommendation or Suggestion for a Replacement AC Unit","agency":{"office":{"code":"FA3016","name":"FA3016 502 CONS CL"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"78236-5286","city":"JBSA LACKLAND","state":"TX","country":"USA"},"organization_id":"500034248","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-07","archive_type":"auto15"},"history":[{"index":3,"title":"RFI-Recommendation or Suggestion for a Replacement AC Unit","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-12T16:57:50.478Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"a4cfc7adb3be4e59843b8f8c8888d63d","solicitation_number":"FA3016FY2620TONAC"}],"contacts":[{"name":"Ernest Sutton","role":"primary","email":"ernest.sutton@us.af.mil"},{"name":"Erika Turner","role":"secondary","email":"erika.turner.1@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"a4cfc7adb3be4e59843b8f8c8888d63d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"a4cfc7adb3be4e59843b8f8c8888d63d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-13T02:51:23.097849893Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6165a5cfb1808829611f2b32141833af729b1075a68aa5e2dda32be77fc0723d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-13T02:51:23.097849893Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.</p>\n\n<p></p>\n\n<p>The replacement needs to be compatible with the following specifications:&nbsp;</p>\n\n<p>Outdoor Unit (Condenser):</p>\n\n<p>Nominal Capacity: 20 TON (240,000 BTU/h)</p>\n\n<p>Voltage: 208/230V &ndash; 3 Phase &ndash; 60HZ</p>\n\n<p>Refrigerant TYPE: R-22</p>\n\n<p>Compressors: 2-Stage (Dual) Scroll Compressors</p>\n\n<p>Fans: 2</p>\n\n<p>Efficiency: Up to 11.0 EER / 14.8 IEER</p>\n\n<p>Dimensions: ~50.4&rdquo; H x 103.4&rdquo; W x 54.3&rdquo; D</p>\n\n<p>Weight: 1133lbs</p>\n\n<p></p>\n\n<p>Inside Unit (Air Handler):</p>\n\n<p>Nominal Capacity: 20 TON (240,000 BTU/h)</p>\n\n<p>Fan Motor Horsepower: 3HP</p>\n\n<p>Nominal Air Flow: 8000 CFM</p>\n\n<p>Electrical: 208/230 Volt, 3-Phrase, 60Hz</p>\n\n<p>Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)</p>\n\n<p></p>\n\n<p></p>\n\n<p>Commercial Heat Element Kit</p>\n\n<p>For Air Handler Unit: 20 TON</p>\n\n<p>Voltage: 240Volts &ndash; 3 Phase &ndash; 60HZ</p>\n\n<p>240 Volts, 3 Phrase</p>\n\n<p>Heating Capacity 19.1W</p>\n\n<p>Total Amps: 46 AMPS</p>\n\n<p></p>\n\n<p>The Statement Of Need and pictures of the current unit are attached for reference.&nbsp;</p>\n\n<p>Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.</p>\n\n<p>We kindly request that you provide any recommendations no later than, <strong>Friday, February 20th by 16:00 CST</strong>.</p>\n\n<p></p>","text":"This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.\n\nThe replacement needs to be compatible with the following specifications:\n\nOutdoor Unit (Condenser):\n\nNominal Capacity: 20 TON (240,000 BTU/h)\n\nVoltage: 208/230V – 3 Phase – 60HZ\n\nRefrigerant TYPE: R-22\n\nCompressors: 2-Stage (Dual) Scroll Compressors\n\nFans: 2\n\nEfficiency: Up to 11.0 EER / 14.8 IEER\n\nDimensions: ~50.4” H x 103.4” W x 54.3” D\n\nWeight: 1133lbs\n\nInside Unit (Air Handler):\n\nNominal Capacity: 20 TON (240,000 BTU/h)\n\nFan Motor Horsepower: 3HP\n\nNominal Air Flow: 8000 CFM\n\nElectrical: 208/230 Volt, 3-Phrase, 60Hz\n\nCooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)\n\nCommercial Heat Element Kit\n\nFor Air Handler Unit: 20 TON\n\nVoltage: 240Volts – 3 Phase – 60HZ\n\n240 Volts, 3 Phrase\n\nHeating Capacity 19.1W\n\nTotal Amps: 46 AMPS\n\nThe Statement Of Need and pictures of the current unit are attached for reference.\n\nPlease be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.\n\nWe kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"FA3016FY2620TONAC","place_of_performance":{"city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4120"}],"due_at":"2026-02-20T22:00:00Z","due_date":"2026-02-20","closes_at":"2026-02-20T22:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","state":"TX","county":null,"county_name":null,"city":"4865000","city_name":"San Antonio","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-13T03:02:31.461264Z","principal_notice_id":"a4cfc7adb3be4e59843b8f8c8888d63d","description":{"text":"This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.\n\nThe replacement needs to be compatible with the following specifications:\n\nOutdoor Unit (Condenser):\n\nNominal Capacity: 20 TON (240,000 BTU/h)\n\nVoltage: 208/230V – 3 Phase – 60HZ\n\nRefrigerant TYPE: R-22\n\nCompressors: 2-Stage (Dual) Scroll Compressors\n\nFans: 2\n\nEfficiency: Up to 11.0 EER / 14.8 IEER\n\nDimensions: ~50.4” H x 103.4” W x 54.3” D\n\nWeight: 1133lbs\n\nInside Unit (Air Handler):\n\nNominal Capacity: 20 TON (240,000 BTU/h)\n\nFan Motor Horsepower: 3HP\n\nNominal Air Flow: 8000 CFM\n\nElectrical: 208/230 Volt, 3-Phrase, 60Hz\n\nCooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)\n\nCommercial Heat Element Kit\n\nFor Air Handler Unit: 20 TON\n\nVoltage: 240Volts – 3 Phase – 60HZ\n\n240 Volts, 3 Phrase\n\nHeating Capacity 19.1W\n\nTotal Amps: 46 AMPS\n\nThe Statement Of Need and pictures of the current unit are attached for reference.\n\nPlease be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.\n\nWe kindly request that you provide any recommendations no later than, Friday, February 20th by 16:00 CST.","html":"<p>This message is a Request for Information issued for market research purposes. We are looking for any recomendations or suggestions for a comparable replacement for a 20 TON Split A/C unit.</p>\n\n<p></p>\n\n<p>The replacement needs to be compatible with the following specifications:&nbsp;</p>\n\n<p>Outdoor Unit (Condenser):</p>\n\n<p>Nominal Capacity: 20 TON (240,000 BTU/h)</p>\n\n<p>Voltage: 208/230V &ndash; 3 Phase &ndash; 60HZ</p>\n\n<p>Refrigerant TYPE: R-22</p>\n\n<p>Compressors: 2-Stage (Dual) Scroll Compressors</p>\n\n<p>Fans: 2</p>\n\n<p>Efficiency: Up to 11.0 EER / 14.8 IEER</p>\n\n<p>Dimensions: ~50.4&rdquo; H x 103.4&rdquo; W x 54.3&rdquo; D</p>\n\n<p>Weight: 1133lbs</p>\n\n<p></p>\n\n<p>Inside Unit (Air Handler):</p>\n\n<p>Nominal Capacity: 20 TON (240,000 BTU/h)</p>\n\n<p>Fan Motor Horsepower: 3HP</p>\n\n<p>Nominal Air Flow: 8000 CFM</p>\n\n<p>Electrical: 208/230 Volt, 3-Phrase, 60Hz</p>\n\n<p>Cooling Coil: 4-Row Direct Expansion (DX) Coil (Copper Tube, Aluminum Fin)</p>\n\n<p></p>\n\n<p></p>\n\n<p>Commercial Heat Element Kit</p>\n\n<p>For Air Handler Unit: 20 TON</p>\n\n<p>Voltage: 240Volts &ndash; 3 Phase &ndash; 60HZ</p>\n\n<p>240 Volts, 3 Phrase</p>\n\n<p>Heating Capacity 19.1W</p>\n\n<p>Total Amps: 46 AMPS</p>\n\n<p></p>\n\n<p>The Statement Of Need and pictures of the current unit are attached for reference.&nbsp;</p>\n\n<p>Please be advised this is an RFI only. This inquiry does not constitute a solicitation, a Request for Quote (RFQ), or a promise to issue and RFQ in the future. A contract will not be awarded based on responses to this notice.</p>\n\n<p>We kindly request that you provide any recommendations no later than, <strong>Friday, February 20th by 16:00 CST</strong>.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Ernest Sutton","role":"primary","email":"ernest.sutton@us.af.mil"},{"name":"Erika Turner","role":"secondary","email":"erika.turner.1@us.af.mil"}],"place_of_performance":{"city":{"code":"65000","name":"San Antonio"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"78236-5286","city":"JBSA LACKLAND","state":"TX","country":"USA"},"naics_codes":["423730"],"award":null,"attachments":[{"resource_id":"2807a897dd464f3aa8a3e91d69f2ec3f","name":"Statement of NEED 20 TON Split AC System.docx","kind":"file","mime_type":".docx","size_bytes":51200,"posted_at":"2026-02-12T16:57:50.478Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2807a897dd464f3aa8a3e91d69f2ec3f/download","mirrored":false}],"awards":[],"related":[{"key":"FA301627Q0008","latest_notice_id":"e1d2dcb8f1414d0abcb11f3cf24381b0","title":"JBSA Lodging Revised Solicitation","solicitation_number":"FA301627Q0008","notice_type":"k","first_type":"k","first_posted":"2026-10-21","last_posted":"2026-11-09","notices":2,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"721110","psc":"V231","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"_____________SOLICITATION NOTICE: JOINT BASE SAN ANTONIO","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-13T07:35:56.258674Z"},{"key":"FA301627Q0015","latest_notice_id":"d906318d3b3b4250971bd74daa469cf1","title":"METC Physical Therapy Technician eBooks FY 27","solicitation_number":"FA301627Q0015","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-01T16:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"513130","psc":"7610","set_aside":"SBA","state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA301626Q0012","latest_notice_id":"8c813adf60f24d628ee8f523a5306063","title":"637TRSS Carpet Cleaning","solicitation_number":"FA301626Q0012","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-25","notices":5,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"561740","psc":"S214","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"FA301627Q0014","latest_notice_id":"ac83672bac824490b0bae4a8eeef8a3a","title":"Aviation Support Equipment Load Testing","solicitation_number":"FA301627Q0014","notice_type":"k","first_type":"k","first_posted":"2026-11-21","last_posted":"2026-11-21","notices":1,"due_at":"2026-12-03T07:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T07:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"811310","psc":"J049","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"433D MAINTENANCE SQUADRON (MXS), JOINT BASE SAN ANTONIO","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-22T05:17:48.835238Z"},{"key":"FA301627Q0020","latest_notice_id":"74fb7dcc9dff472f98f5dc4d467684d9","title":"Licensed Practical Nurse (LPN)","solicitation_number":"FA301627Q0020","notice_type":"o","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-25","notices":2,"due_at":"2026-12-15T16:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"621399","psc":"Q401","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"1220 TRUEMPER DR., JBSA-LACKLAND, TX 78236","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open":[],"similar_open_total":0,"indexable":false}