Special notice

Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications

BA-1063

Department of Energy, Battelle Energy Alliance–doe CNTR. Medical Laboratories.

Response deadline

January 13, 2026 at 11:00 AM EST

Closed 317 days ago. Posted January 13, 2025. Scheduled to archive January 28, 2026.

Get the next one like this from Department of Energy by email, the day it is posted.Find my opportunities

This one closed in 2026

4 like it are open now in medical laboratories

  • NWI Offsite Pathology Services

    Department of Veterans Affairs, Network Contract Office 23

    SolicitationSmall businessNAICS 621511Nebraska36C26326R0063
    Due in 4 daysNov 30
  • NBIMC Bloodborne Services

    Department of the Navy, NAVSUP FLT Log CTR Norfolk

    Sources soughtNAICS 621511MarylandN0018927R0001
    Closes in 13 daysDec 9
  • Reference and Esoteric Laboratory Testing

    Department of Veterans Affairs, 242-Network Contract Office 02

    SolicitationNAICS 621511Location not published36C24227R0003
    Closes in 18 daysDec 14

All 4 open in medical laboratories

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary

Description

As published on SAM.gov.

Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications

An innovative electrochemical process delivering cost-effective, sustainable solutions for alloy coatings and bulk manufacturing directly from metal oxides.

The Challenge

Traditional methods for manufacturing titanium-tantalum alloys rely on energy-intensive melting or complex powder metallurgy (PM) processes. These approaches are time-consuming, expensive, and generate significant material waste, particularly from degraded components exposed to corrosive environments during production. As demand for advanced biomedical materials and high-performance alloys grows, the industry faces pressure to innovate cost-effective and sustainable manufacturing technologies.

How It Works

This groundbreaking process utilizes the “contact electrode” concept to synthesize titanium-tantalum alloys directly from tantalum oxide:

  • Direct Electrochemical Reduction: Tantalum oxide is electrochemically reduced in molten calcium chloride, releasing oxygen ions to the electrolyte.
  • In Situ Alloy Formation: The reduced tantalum reacts chemically with a titanium current collector to form the alloy during the reduction process.
  • Versatility: The method is applicable to both alloy coatings and bulk alloys, supporting a wide range of manufacturing needs.
  • Low-Waste Approach: Unlike traditional methods, the current collector is intentionally incorporated into the final alloy, eliminating waste and maximizing material use.

Key Advantages

  • Cost Efficiency: Simplifies manufacturing by eliminating intermediate processing steps, reducing time and energy consumption.
  • Material Versatility: Enables synthesis of advanced engineering alloys directly from oxide precursors.
  • Sustainability: Converts degraded current collectors into valuable alloy materials, reducing industrial waste.
  • Scalability: Offers potential integration with additive manufacturing (AM) techniques for near-net-shape production.
  • Biomedical Potential: Titanium-tantalum alloys are ideal for applications such as implants, thanks to their biocompatibility and corrosion resistance.

Market Applications

  • Biomedical Devices: Manufacturing biocompatible titanium-tantalum alloys for implants and prosthetics.
  • Metal and Structural Materials: Producing high-performance alloys for aerospace, automotive, and defense applications.
  • Corrosion-Resistant Coatings: Creating durable alloy coatings for industrial equipment.
  • Additive Manufacturing Integration: Fabricating near-net-shape alloy components for advanced engineering applications.

INL’s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations.

We do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. January 13, 2025

    Special notice

    Due January 13, 2026 at 11:00 AM EST. SAM.gov, notice 77eb73d8edc144dab861921986719c5c

    1 revision on SAM
    • January 13, 2025: publish, special notice

Points of contact