{"canonical":"https://sealedbidder.com/opportunities/ba1063","key":"BA1063","url":"https://sealedbidder.com/opportunities/ba1063","title":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications","solicitation_number":"BA-1063","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-13T16:00:00Z","first_posted":"2025-01-13","last_posted":"2025-01-13","department":"ENERGY, DEPARTMENT OF","subagency":"ENERGY, DEPARTMENT OF","office":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":"621511","psc":null,"set_aside":null,"place_state":"ID","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"16019","place_county_name":"Bonneville County","place_city":"1639700","place_city_name":"Idaho Falls","winner":null,"award_amount":null,"publications":[{"notice_id":"77eb73d8edc144dab861921986719c5c","title":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications","solicitation_number":"BA-1063","notice_type":"s","base_type":"s","posted":"2025-01-13","posted_at":"2025-01-13T17:18:47.983Z","due_at":"2026-01-13T16:00:00Z","due_date":"2026-01-13","cancelled":false,"archived":true,"archive_date":"2026-01-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/77eb73d8edc144dab861921986719c5c/view","enriched":true,"history":[{"index":3,"title":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-13T17:18:47.983Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"77eb73d8edc144dab861921986719c5c","solicitation_number":"BA-1063"}]}],"latest_notice_id":"77eb73d8edc144dab861921986719c5c","first_type":"s","notices":[{"dates":{"posted":"2025-01-13","posted_at":"2025-01-13T17:18:47.983Z","created_at":"2025-01-13T17:16:05.835Z","modified_at":"2026-01-29T04:55:43.303Z","response_deadline":{"raw":"2026-01-13T11:00:00-05:00","utc":"2026-01-13T16:00:00Z","date":"2026-01-13","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/77eb73d8edc144dab861921986719c5c/view"},"naics":{"codes":["621511"],"primary":"621511"},"title":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications","agency":{"office":{"code":"899050","name":"BATTELLE ENERGY ALLIANCE–DOE CNTR"},"subtier":{"code":"8900","name":"ENERGY, DEPARTMENT OF"},"department":{"code":"089","name":"ENERGY, DEPARTMENT OF"},"office_address":{"zip":"83415","city":"Idaho Falls","state":"ID","country":"USA"},"organization_id":"500047763","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-28","archive_type":"auto15"},"history":[{"index":3,"title":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-13T17:18:47.983Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"77eb73d8edc144dab861921986719c5c","solicitation_number":"BA-1063"}],"contacts":[{"name":"Technology Deployment","role":"primary","email":"td@inl.gov"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"77eb73d8edc144dab861921986719c5c","lineage_id":"77eb73d8edc144dab861921986719c5c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-25T04:26:06.136329116Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5132cc97954760f399c0b2d0c154e2048bb8722d221c7cad36b88d5e33d43860","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-25T04:26:06.136329116Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications</p>\n\n<p>An innovative electrochemical process delivering cost-effective, sustainable solutions for alloy coatings and bulk manufacturing directly from metal oxides.</p>\n\n<p>The Challenge</p>\n\n<p>Traditional methods for manufacturing titanium-tantalum alloys rely on energy-intensive melting or complex powder metallurgy (PM) processes. These approaches are time-consuming, expensive, and generate significant material waste, particularly from degraded components exposed to corrosive environments during production. As demand for advanced biomedical materials and high-performance alloys grows, the industry faces pressure to innovate cost-effective and sustainable manufacturing technologies.</p>\n\n<p>How It Works</p>\n\n<p>This groundbreaking process utilizes the &ldquo;contact electrode&rdquo; concept to synthesize titanium-tantalum alloys directly from tantalum oxide:</p>\n\n<ul>\n\t<li>Direct Electrochemical Reduction: Tantalum oxide is electrochemically reduced in molten calcium chloride, releasing oxygen ions to the electrolyte.</li>\n\t<li>In Situ Alloy Formation: The reduced tantalum reacts chemically with a titanium current collector to form the alloy during the reduction process.</li>\n\t<li>Versatility: The method is applicable to both alloy coatings and bulk alloys, supporting a wide range of manufacturing needs.</li>\n\t<li>Low-Waste Approach: Unlike traditional methods, the current collector is intentionally incorporated into the final alloy, eliminating waste and maximizing material use.</li>\n</ul>\n\n<p>Key Advantages</p>\n\n<ul>\n\t<li>Cost Efficiency: Simplifies manufacturing by eliminating intermediate processing steps, reducing time and energy consumption.</li>\n\t<li>Material Versatility: Enables synthesis of advanced engineering alloys directly from oxide precursors.</li>\n\t<li>Sustainability: Converts degraded current collectors into valuable alloy materials, reducing industrial waste.</li>\n\t<li>Scalability: Offers potential integration with additive manufacturing (AM) techniques for near-net-shape production.</li>\n\t<li>Biomedical Potential: Titanium-tantalum alloys are ideal for applications such as implants, thanks to their biocompatibility and corrosion resistance.</li>\n</ul>\n\n<p>Market Applications</p>\n\n<ul>\n\t<li>Biomedical Devices: Manufacturing biocompatible titanium-tantalum alloys for implants and prosthetics.</li>\n\t<li>Metal and Structural Materials: Producing high-performance alloys for aerospace, automotive, and defense applications.</li>\n\t<li>Corrosion-Resistant Coatings: Creating durable alloy coatings for industrial equipment.</li>\n\t<li>Additive Manufacturing Integration: Fabricating near-net-shape alloy components for advanced engineering applications.</li>\n</ul>\n\n<p><!-- notionvc: 4b2a9493-89bc-48a1-a25f-468e0d989efc --></p>\n\n<p>INL&rsquo;s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations.</p>\n\n<p>We do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.</p>\n\n<p><!-- notionvc: cfa317e8-a07f-497e-a074-5f85ea0e6f1c --></p>","text":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications\n\nAn innovative electrochemical process delivering cost-effective, sustainable solutions for alloy coatings and bulk manufacturing directly from metal oxides.\n\nThe Challenge\n\nTraditional methods for manufacturing titanium-tantalum alloys rely on energy-intensive melting or complex powder metallurgy (PM) processes. These approaches are time-consuming, expensive, and generate significant material waste, particularly from degraded components exposed to corrosive environments during production. As demand for advanced biomedical materials and high-performance alloys grows, the industry faces pressure to innovate cost-effective and sustainable manufacturing technologies.\n\nHow It Works\n\nThis groundbreaking process utilizes the “contact electrode” concept to synthesize titanium-tantalum alloys directly from tantalum oxide:\n\n• Direct Electrochemical Reduction: Tantalum oxide is electrochemically reduced in molten calcium chloride, releasing oxygen ions to the electrolyte.\n\n• In Situ Alloy Formation: The reduced tantalum reacts chemically with a titanium current collector to form the alloy during the reduction process.\n\n• Versatility: The method is applicable to both alloy coatings and bulk alloys, supporting a wide range of manufacturing needs.\n\n• Low-Waste Approach: Unlike traditional methods, the current collector is intentionally incorporated into the final alloy, eliminating waste and maximizing material use.\n\nKey Advantages\n\n• Cost Efficiency: Simplifies manufacturing by eliminating intermediate processing steps, reducing time and energy consumption.\n\n• Material Versatility: Enables synthesis of advanced engineering alloys directly from oxide precursors.\n\n• Sustainability: Converts degraded current collectors into valuable alloy materials, reducing industrial waste.\n\n• Scalability: Offers potential integration with additive manufacturing (AM) techniques for near-net-shape production.\n\n• Biomedical Potential: Titanium-tantalum alloys are ideal for applications such as implants, thanks to their biocompatibility and corrosion resistance.\n\nMarket Applications\n\n• Biomedical Devices: Manufacturing biocompatible titanium-tantalum alloys for implants and prosthetics.\n\n• Metal and Structural Materials: Producing high-performance alloys for aerospace, automotive, and defense applications.\n\n• Corrosion-Resistant Coatings: Creating durable alloy coatings for industrial equipment.\n\n• Additive Manufacturing Integration: Fabricating near-net-shape alloy components for advanced engineering applications.\n\nINL’s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations.\n\nWe do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"BA-1063","place_of_performance":{"zip":"83415","city":{"code":"39700","name":"Idaho Falls"},"state":{"code":"ID","name":"Idaho"},"country":{"code":"USA","name":"UNITED STATES"}}}],"due_at":"2026-01-13T16:00:00Z","due_date":"2026-01-13","closes_at":"2026-01-13T16:00:00Z","awardable":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","state":"ID","county":"16019","county_name":"Bonneville County","city":"1639700","city_name":"Idaho Falls","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-25T05:14:59.249783Z","principal_notice_id":"77eb73d8edc144dab861921986719c5c","description":{"text":"Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications\n\nAn innovative electrochemical process delivering cost-effective, sustainable solutions for alloy coatings and bulk manufacturing directly from metal oxides.\n\nThe Challenge\n\nTraditional methods for manufacturing titanium-tantalum alloys rely on energy-intensive melting or complex powder metallurgy (PM) processes. These approaches are time-consuming, expensive, and generate significant material waste, particularly from degraded components exposed to corrosive environments during production. As demand for advanced biomedical materials and high-performance alloys grows, the industry faces pressure to innovate cost-effective and sustainable manufacturing technologies.\n\nHow It Works\n\nThis groundbreaking process utilizes the “contact electrode” concept to synthesize titanium-tantalum alloys directly from tantalum oxide:\n\n• Direct Electrochemical Reduction: Tantalum oxide is electrochemically reduced in molten calcium chloride, releasing oxygen ions to the electrolyte.\n\n• In Situ Alloy Formation: The reduced tantalum reacts chemically with a titanium current collector to form the alloy during the reduction process.\n\n• Versatility: The method is applicable to both alloy coatings and bulk alloys, supporting a wide range of manufacturing needs.\n\n• Low-Waste Approach: Unlike traditional methods, the current collector is intentionally incorporated into the final alloy, eliminating waste and maximizing material use.\n\nKey Advantages\n\n• Cost Efficiency: Simplifies manufacturing by eliminating intermediate processing steps, reducing time and energy consumption.\n\n• Material Versatility: Enables synthesis of advanced engineering alloys directly from oxide precursors.\n\n• Sustainability: Converts degraded current collectors into valuable alloy materials, reducing industrial waste.\n\n• Scalability: Offers potential integration with additive manufacturing (AM) techniques for near-net-shape production.\n\n• Biomedical Potential: Titanium-tantalum alloys are ideal for applications such as implants, thanks to their biocompatibility and corrosion resistance.\n\nMarket Applications\n\n• Biomedical Devices: Manufacturing biocompatible titanium-tantalum alloys for implants and prosthetics.\n\n• Metal and Structural Materials: Producing high-performance alloys for aerospace, automotive, and defense applications.\n\n• Corrosion-Resistant Coatings: Creating durable alloy coatings for industrial equipment.\n\n• Additive Manufacturing Integration: Fabricating near-net-shape alloy components for advanced engineering applications.\n\nINL’s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations.\n\nWe do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.","html":"<p>Titanium-Tantalum Alloy Manufacturing for Biomedical and Engineering Applications</p>\n\n<p>An innovative electrochemical process delivering cost-effective, sustainable solutions for alloy coatings and bulk manufacturing directly from metal oxides.</p>\n\n<p>The Challenge</p>\n\n<p>Traditional methods for manufacturing titanium-tantalum alloys rely on energy-intensive melting or complex powder metallurgy (PM) processes. These approaches are time-consuming, expensive, and generate significant material waste, particularly from degraded components exposed to corrosive environments during production. As demand for advanced biomedical materials and high-performance alloys grows, the industry faces pressure to innovate cost-effective and sustainable manufacturing technologies.</p>\n\n<p>How It Works</p>\n\n<p>This groundbreaking process utilizes the &ldquo;contact electrode&rdquo; concept to synthesize titanium-tantalum alloys directly from tantalum oxide:</p>\n\n<ul>\n\t<li>Direct Electrochemical Reduction: Tantalum oxide is electrochemically reduced in molten calcium chloride, releasing oxygen ions to the electrolyte.</li>\n\t<li>In Situ Alloy Formation: The reduced tantalum reacts chemically with a titanium current collector to form the alloy during the reduction process.</li>\n\t<li>Versatility: The method is applicable to both alloy coatings and bulk alloys, supporting a wide range of manufacturing needs.</li>\n\t<li>Low-Waste Approach: Unlike traditional methods, the current collector is intentionally incorporated into the final alloy, eliminating waste and maximizing material use.</li>\n</ul>\n\n<p>Key Advantages</p>\n\n<ul>\n\t<li>Cost Efficiency: Simplifies manufacturing by eliminating intermediate processing steps, reducing time and energy consumption.</li>\n\t<li>Material Versatility: Enables synthesis of advanced engineering alloys directly from oxide precursors.</li>\n\t<li>Sustainability: Converts degraded current collectors into valuable alloy materials, reducing industrial waste.</li>\n\t<li>Scalability: Offers potential integration with additive manufacturing (AM) techniques for near-net-shape production.</li>\n\t<li>Biomedical Potential: Titanium-tantalum alloys are ideal for applications such as implants, thanks to their biocompatibility and corrosion resistance.</li>\n</ul>\n\n<p>Market Applications</p>\n\n<ul>\n\t<li>Biomedical Devices: Manufacturing biocompatible titanium-tantalum alloys for implants and prosthetics.</li>\n\t<li>Metal and Structural Materials: Producing high-performance alloys for aerospace, automotive, and defense applications.</li>\n\t<li>Corrosion-Resistant Coatings: Creating durable alloy coatings for industrial equipment.</li>\n\t<li>Additive Manufacturing Integration: Fabricating near-net-shape alloy components for advanced engineering applications.</li>\n</ul>\n\n<p><!-- notionvc: 4b2a9493-89bc-48a1-a25f-468e0d989efc --></p>\n\n<p>INL&rsquo;s Technology Deployment department focuses solely on licensing intellectual property and collaborating with industry partners who can commercialize our innovations.</p>\n\n<p>We do not engage in purchasing, procurement, or hiring external services for technology development. Our objective is to connect with companies interested in licensing and bringing our technologies to market.</p>\n\n<p><!-- notionvc: cfa317e8-a07f-497e-a074-5f85ea0e6f1c --></p>","origin":"detail"},"contacts":[{"name":"Technology Deployment","role":"primary","email":"td@inl.gov"}],"place_of_performance":{"zip":"83415","city":{"code":"39700","name":"Idaho Falls"},"state":{"code":"ID","name":"Idaho"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"83415","city":"Idaho Falls","state":"ID","country":"USA"},"naics_codes":["621511"],"award":null,"attachments":[],"awards":[],"related":[{"key":"INL26050","latest_notice_id":"f3cd6f0d4f88410cbb246717f5104db4","title":"Long-Duration Energy Storage (LDES) Battery System","solicitation_number":"INL-26-050","notice_type":"r","first_type":"r","first_posted":"2026-08-24","last_posted":"2026-11-17","notices":5,"due_at":"2026-12-09T06:59:00Z","due_date":"2026-12-08","closes_at":"2026-12-09T06:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":null,"psc":null,"set_aside":null,"state":"ID","county":"16019","county_name":"Bonneville County","city":"1639700","city_name":"Idaho Falls","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"INL26029","latest_notice_id":"f18b48de8e084122ba2896b09242d0ec","title":"Fiber Dial Room Refurbishment","solicitation_number":"INL-26-029","notice_type":"r","first_type":"r","first_posted":"2026-02-25","last_posted":"2026-03-18","notices":4,"due_at":"2026-12-12T06:59:00Z","due_date":"2026-12-11","closes_at":"2026-12-12T06:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":"238210","psc":null,"set_aside":null,"state":"ID","county":"16019","county_name":"Bonneville County","city":"1639700","city_name":"Idaho Falls","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"INL27008","latest_notice_id":"b13bed6365ad4327806d42552a28e099","title":"Launchpad Infrastructure Project","solicitation_number":"INL-27-008","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2027-01-16T06:59:00Z","due_date":"2027-01-15","closes_at":"2027-01-16T06:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":null,"psc":null,"set_aside":null,"state":"ID","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"INL26036","latest_notice_id":"f27aa458a37a49e2992cae155993cb67","title":"TAN 675 Lighting Controls Upgrade","solicitation_number":"INL-26-036","notice_type":"r","first_type":"r","first_posted":"2026-03-24","last_posted":"2026-03-24","notices":1,"due_at":"2027-01-30T06:59:00Z","due_date":"2027-01-29","closes_at":"2027-01-30T06:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":null,"psc":null,"set_aside":null,"state":"ID","county":"16019","county_name":"Bonneville County","city":"1639700","city_name":"Idaho Falls","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"INL026035","latest_notice_id":"d7adb0aee0094d8893919aba01b689c4","title":"TAN AHU Replacement","solicitation_number":"INL-026-035","notice_type":"r","first_type":"r","first_posted":"2026-03-24","last_posted":"2026-03-24","notices":1,"due_at":"2027-01-30T06:59:00Z","due_date":"2027-01-29","closes_at":"2027-01-30T06:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899050","office_name":"BATTELLE ENERGY ALLIANCE–DOE CNTR","naics":null,"psc":null,"set_aside":null,"state":"ID","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"36C26326R0063","latest_notice_id":"d70c843cc4d84fd69905d2e17ce78771","title":"NWI Offsite Pathology Services","solicitation_number":"36C26326R0063","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-20","notices":5,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"621511","psc":"Q515","set_aside":"SBA","state":"NE","county":"31055","county_name":"Douglas County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N0018927R0001","latest_notice_id":"63940568a9a1466e83c3068f740e6182","title":"NBIMC Bloodborne Services","solicitation_number":"N0018927R0001","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T21:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00189","office_name":"NAVSUP FLT LOG CTR NORFOLK","naics":"621511","psc":"Q301","set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"DEFENSE SERUM REPOSITORY (DODSR) IN SILVER SPRING, MARYLAND","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227R0003","latest_notice_id":"fdcb3e1754094283a6e075bd0ed363e9","title":"Q301--Reference and Esoteric Laboratory Testing","solicitation_number":"36C24227R0003","notice_type":"o","first_type":"p","first_posted":"2026-09-22","last_posted":"2026-11-20","notices":8,"due_at":"2026-12-14T20:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"621511","psc":"Q301","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":4,"indexable":false}