Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,710 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Stryker Procare Endoscopy Mintenance Services

36C26025Q0811

Department of Veterans Affairs, 260-Network Contract Office 20. Electronic and Precision Equipment Repair and Maintenance.

Response deadline

August 18, 2025 at 6:00 PM EDT

Closed 465 days ago. Posted August 5, 2025. Scheduled to archive September 2, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

63 like it are open now in electronic and precision equipment repair and maintenance

All 63 open in electronic and precision equipment repair and maintenance

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 811210 (electronic and precision equipment repair and maintenance), means no more than $34 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of August 5, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

SOURCES SOUGHT NOTICE This is a Sources Sought NOTICE (SSN) ONLY. The U.S. Government is conducting market research only to determine the availability of qualified sources capable of providing maintenance and repair services to ensure proper operation of Stryker Endoscopes at the Boise VA Medical Center. Potential Contractors are invited to provide a response via e-mail to Contract Specialist at tracy.heath@va.gov by 08/18/2025 15:00 (PT). Responses will be used to determine the appropriate strategy for a potential acquisition. Please clearly identify any information your company considers sensitive or proprietary. This notice is issued solely for information and planning purposes - it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes in response to this sources sought synopsis. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ, if any is issued. BACKGROUND: The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service. NAICS: 811210, Electronic & Precision Equipment Repair and Maintenance. Interested potential Contractors please provide the following. 1) Company Name, address, point of contact, phone number, email address, and UEI Please indicate business size: Small Disadvantage Business (SDB)____ 8(a)____ Historically Underutilized Business Zone (HUBZone)____ Service-Disabled Veteran-Owned Small Business (SDVOSB)____ Veteran-Owned Small Business (VOSB)_____ Economically Disadvantaged Women-Owned Small Business (EDWOSB)_____ Women-Owned Small Business concerns (WOSB)_____ Small Business_____ Large Business_____ Please state if you possess a Federal Supply Schedule (FSS)______. Please state if your FSS Schedule is under Group 66 III Cat 605-2A________ 2) Please submit a brief capability statement (maximum three pages) with enough information to demonstrate to the Veterans Affairs that you have the enough resources, personnel, and experience to perform on-site preventative maintenance and repair services as required in the attached Draft Statement of Work. **Draft Statement of Work STATEMENT OF WORK (SOW) Stryker Pro-Care Maintenance Background. The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service. Sensitive Patient Records will not be viewed because of this requirement. Access to the controlled area will be provided by POC, OR Staff, Police Service, or another designated and authorized BVAMC employee. Scope. Contractor to provide on-site preventative maintenance and repair services on the same day as required, included but not limited to all labor, certified service technicians, travel, living expenses, maintenance materials and service, and tools, and necessary parts to perform the required service in accordance with the manufacturer s service manuals for the equipment listed herein. This requirement is subject to inspection and verification by a government representative. An unlimited number of repairs of the Stryker Endoscopy Equipment, including labor and parts, regardless of fault, except as provided in subsection (b) below. Replacement equipment for the Stryker Endoscopy Equipment, if necessary. Stryker Endoscopy shall have sole discretion to determine whether the Stryker Endoscopy Equipment shall be repaired or replaced. Use of loaner equipment to replace the Stryker Endoscopy Equipment during repair, except where the item is handled through Stryker Endoscopy s repair / replace program; and Prioritized repairs over non-contracted customers, with no additional administration or approval process. Will provide proprietary software upgrades. Will provide a system image DVD, of the current version, to reimage disk drive prior to return for repair. Any hard drives removed from the system will remain VA property. 24-hour replacements and loaners Coverage for mandatory calibrations on insufflators Quality inspection on all repairs in accordance with FDA Quality System Regulations Free shipping to and from Boise VA Medical Center Components include but are not limited to technical support 7 days per week, 24 hours per day. Support and any work done must be warranted by Stryker. The support is for the equipment below: Performance Monitoring. Performance will be monitored by periodic inspections and observation of work. Work will be observed by the POC, or designee, during performance of scheduled maintenance service and inspections and/or during repair service. Equipment operators will be contacted to report on contractor performance when POC, or designee, is not available. Security Requirements. The C&A requirements do not apply, and a Security Accreditation Package is not required. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). No Government supplied Equipment or Information is required or anticipated. Other Pertinent Information or Special Considerations. a. Identification of Possible Follow-on Work. No Follow-on work is anticipated. b. Identification of Potential Conflicts of Interest (COI). No Known COI c. Identification of Non-Disclosure Requirements. Contractors will not have access to Sensitive or Proprietary Information. Any Patient Information that may have been observed during the course of the work must not be discussed, or shared, with anyone beyond the Service Staff or any person who does not have the need to know such information. d. Packaging, Packing and Shipping Instructions. N/A e. Inspection and Acceptance Criteria. POC, or designee, will verify that the unit is working within Manufacture s specifications after completion of service or repair. Risk Control. The Contractor shall obtain all necessary licenses and/or permits required to perform this work. The contractor shall take all precautions necessary to protect people and property from injury or damage during the performance of this contract. The contractor shall be responsible for any injury to any contractor representative, or others, as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by the contractor s fault or negligence. If Patient Information may have been observed during the performance of work, the Contractor will not discuss any patient issues that may have been observed during the course of the work. Place of Performance. All services will be performed at Boise VA Medical Center (BVAMC) Operating Room (OR). Period of Performance. Base year 10/23/2025 10/22/2026, plus four option years. Delivery Schedule. Service Reports will be emailed or faxed to POC by the 5th workday after completion of the work.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. August 5, 2025

    Sources sought

    Due August 18, 2025 at 6:00 PM EDT. SAM.gov, notice 3ed7998a1bc748f89457ed08e33de937

    1 revision on SAM
    • August 5, 2025: publish, sources sought

Points of contact