{"canonical":"https://sealedbidder.com/opportunities/36c26025q0811","key":"36C26025Q0811","url":"https://sealedbidder.com/opportunities/36c26025q0811","title":"J065--Stryker Procare Endoscopy Mintenance Services","solicitation_number":"36C26025Q0811","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-18T22:00:00Z","first_posted":"2025-08-05","last_posted":"2025-08-05","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"811210","psc":"J065","set_aside":null,"place_state":"ID","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"16001","place_county_name":"Ada County","place_city":"1608830","place_city_name":"Boise City","winner":null,"award_amount":null,"publications":[{"notice_id":"3ed7998a1bc748f89457ed08e33de937","title":"J065--Stryker Procare Endoscopy Mintenance Services","solicitation_number":"36C26025Q0811","notice_type":"r","base_type":"r","posted":"2025-08-05","posted_at":"2025-08-05T21:24:46.973Z","due_at":"2025-08-18T22:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2025-09-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3ed7998a1bc748f89457ed08e33de937/view","enriched":true,"history":[{"index":3,"title":"J065--Stryker Procare Endoscopy Mintenance Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-05T21:24:46.973Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3ed7998a1bc748f89457ed08e33de937","solicitation_number":"36C26025Q0811"}]}],"latest_notice_id":"3ed7998a1bc748f89457ed08e33de937","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-08-05","posted_at":"2025-08-05T21:24:46.973Z","created_at":"2025-08-05T21:24:44.723Z","modified_at":"2025-09-03T04:00:17.455Z","response_deadline":{"raw":"2025-08-18T15:00:00-07:00","utc":"2025-08-18T22:00:00Z","date":"2025-08-18","time":"15:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3ed7998a1bc748f89457ed08e33de937/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--Stryker Procare Endoscopy Mintenance Services","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-02","archive_type":"auto_custom"},"history":[{"index":3,"title":"J065--Stryker Procare Endoscopy Mintenance Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-05T21:24:46.973Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3ed7998a1bc748f89457ed08e33de937","solicitation_number":"36C26025Q0811"}],"contacts":[{"name":"Tracy Heath","role":"primary","email":"tracy.heath@va.gov","phone":"253-888-4903","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"3ed7998a1bc748f89457ed08e33de937","lineage_id":"3ed7998a1bc748f89457ed08e33de937","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-06T01:29:11.784078972Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"c76744a0429173500db5d6d6b78e25666898adbd9a9bc875a3654240671fc2ea","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-06T01:29:11.784078972Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"SOURCES SOUGHT NOTICE\n\nThis is a Sources Sought NOTICE (SSN) ONLY. The U.S. Government is conducting market research only to determine the availability of qualified sources capable of providing maintenance and repair services to ensure proper operation of Stryker Endoscopes at the Boise VA Medical Center. Potential Contractors are invited to provide a response via e-mail to Contract Specialist at tracy.heath@va.gov by 08/18/2025 15:00 (PT). Responses will be used to determine the appropriate strategy for a potential acquisition. Please clearly identify any information your company considers sensitive or proprietary. This notice is issued solely for information and planning purposes - it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes in response to this sources sought synopsis. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ, if any is issued. \n\nBACKGROUND: The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment.  Qualified Service is required to maintain the devices to Manufacturer s specifications.  The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.\n\nNAICS: 811210, Electronic & Precision Equipment Repair and Maintenance.\n\nInterested potential Contractors please provide the following.\n\n1) Company Name, address, point of contact, phone number, email address, and UEI\n\nPlease indicate business size: \nSmall Disadvantage Business (SDB)____ \n8(a)____\nHistorically Underutilized Business Zone (HUBZone)____\nService-Disabled Veteran-Owned Small Business (SDVOSB)____\nVeteran-Owned Small Business (VOSB)_____\nEconomically Disadvantaged Women-Owned Small Business (EDWOSB)_____\nWomen-Owned Small Business concerns (WOSB)_____\nSmall Business_____\nLarge Business_____\n\nPlease state if you possess a Federal Supply Schedule (FSS)______. Please state if your FSS Schedule is under Group 66 III Cat 605-2A________\n\n2) Please submit a brief capability statement (maximum three pages) with enough information to demonstrate to the Veterans Affairs that you have the enough resources, personnel, and experience to perform on-site preventative maintenance and repair services as required in the attached Draft Statement of Work.\n\n**Draft Statement of Work\n\nSTATEMENT OF WORK (SOW)\nStryker Pro-Care Maintenance\nBackground.  The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment.  Qualified Service is required to maintain the devices to Manufacturer s specifications.  The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.  Sensitive Patient Records will not be viewed because of this requirement.  Access to the controlled area will be provided by POC, OR Staff, Police Service, or another designated and authorized BVAMC employee.\nScope.  \nContractor to provide on-site preventative maintenance and repair services on the same day as required, included but not limited to all labor, certified service technicians, travel, living expenses, maintenance materials and service, and tools, and necessary parts to perform the required service in accordance with the manufacturer s service manuals for the equipment listed herein. This requirement is subject to inspection and verification by a government representative.\nAn unlimited number of repairs of the Stryker Endoscopy Equipment, including labor and parts, regardless of fault, except as provided in subsection (b) below.\nReplacement equipment for the Stryker Endoscopy Equipment, if necessary. Stryker Endoscopy shall have sole discretion to determine whether the Stryker Endoscopy Equipment shall be repaired or replaced.\nUse of loaner equipment to replace the Stryker Endoscopy Equipment during repair, except where the item is handled through Stryker Endoscopy s repair / replace program; and\nPrioritized repairs over non-contracted customers, with no additional administration or approval process.\nWill provide proprietary software upgrades. \nWill provide a system image DVD, of the current version, to reimage disk drive prior to return for repair.\nAny hard drives removed from the system will remain VA property. \n24-hour replacements and loaners\nCoverage for mandatory calibrations on insufflators\nQuality inspection on all repairs in accordance with FDA Quality System Regulations\nFree shipping to and from Boise VA Medical Center\n\nComponents include but are not limited to technical support 7 days per week, 24 hours per day. Support and any work done must be warranted by Stryker. The support is for the equipment below: \n\n\nPerformance Monitoring. Performance will be monitored by periodic inspections and observation of work.  Work will be observed by the POC, or designee, during performance of scheduled maintenance service and inspections and/or during repair service.  Equipment operators will be contacted to report on contractor performance when POC, or designee, is not available.\nSecurity Requirements.  The C&A requirements do not apply, and a Security Accreditation Package is not required.\n  \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).  \nNo Government supplied Equipment or Information is required or anticipated.\nOther Pertinent Information or Special Considerations.  \n a.  Identification of Possible Follow-on Work.  No Follow-on work is anticipated.\n b.  Identification of Potential Conflicts of Interest (COI).  No Known COI\n c.  Identification of Non-Disclosure Requirements.  Contractors will not have access to Sensitive or Proprietary Information.  Any Patient Information that may have been observed during the course of the work must not be discussed, or shared, with anyone beyond the Service Staff or any person who does not have the need to know such information.\n d.  Packaging, Packing and Shipping Instructions.  N/A\n e.  Inspection and Acceptance Criteria.  POC, or designee, will verify that the unit is working within Manufacture s specifications after completion of service or repair.\nRisk Control.  The Contractor shall obtain all necessary licenses and/or permits required to perform this work. The contractor shall take all precautions necessary to protect people and property from injury or damage during the performance of this contract.  The contractor shall be responsible for any injury to any contractor representative, or others, as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by the contractor s fault or negligence.\nIf Patient Information may have been observed during the performance of work, the Contractor will not discuss any patient issues that may have been observed during the course of the work.\nPlace of Performance.  All services will be performed at Boise VA Medical Center (BVAMC) Operating Room (OR).\nPeriod of Performance.  Base year 10/23/2025   10/22/2026, plus four option years.\nDelivery Schedule.  Service Reports will be emailed or faxed to POC by the 5th workday after completion of the work.","text":"SOURCES SOUGHT NOTICE\n\nThis is a Sources Sought NOTICE (SSN) ONLY. The U.S. Government is conducting market research only to determine the availability of qualified sources capable of providing maintenance and repair services to ensure proper operation of Stryker Endoscopes at the Boise VA Medical Center. Potential Contractors are invited to provide a response via e-mail to Contract Specialist at tracy.heath@va.gov by 08/18/2025 15:00 (PT). Responses will be used to determine the appropriate strategy for a potential acquisition. Please clearly identify any information your company considers sensitive or proprietary. This notice is issued solely for information and planning purposes - it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes in response to this sources sought synopsis. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ, if any is issued.\n\nBACKGROUND: The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.\n\nNAICS: 811210, Electronic & Precision Equipment Repair and Maintenance.\n\nInterested potential Contractors please provide the following.\n\n1) Company Name, address, point of contact, phone number, email address, and UEI\n\nPlease indicate business size:\nSmall Disadvantage Business (SDB)____\n8(a)____\nHistorically Underutilized Business Zone (HUBZone)____\nService-Disabled Veteran-Owned Small Business (SDVOSB)____\nVeteran-Owned Small Business (VOSB)_____\nEconomically Disadvantaged Women-Owned Small Business (EDWOSB)_____\nWomen-Owned Small Business concerns (WOSB)_____\nSmall Business_____\nLarge Business_____\n\nPlease state if you possess a Federal Supply Schedule (FSS)______. Please state if your FSS Schedule is under Group 66 III Cat 605-2A________\n\n2) Please submit a brief capability statement (maximum three pages) with enough information to demonstrate to the Veterans Affairs that you have the enough resources, personnel, and experience to perform on-site preventative maintenance and repair services as required in the attached Draft Statement of Work.\n\n**Draft Statement of Work\n\nSTATEMENT OF WORK (SOW)\nStryker Pro-Care Maintenance\nBackground. The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service. Sensitive Patient Records will not be viewed because of this requirement. Access to the controlled area will be provided by POC, OR Staff, Police Service, or another designated and authorized BVAMC employee.\nScope.\nContractor to provide on-site preventative maintenance and repair services on the same day as required, included but not limited to all labor, certified service technicians, travel, living expenses, maintenance materials and service, and tools, and necessary parts to perform the required service in accordance with the manufacturer s service manuals for the equipment listed herein. This requirement is subject to inspection and verification by a government representative.\nAn unlimited number of repairs of the Stryker Endoscopy Equipment, including labor and parts, regardless of fault, except as provided in subsection (b) below.\nReplacement equipment for the Stryker Endoscopy Equipment, if necessary. Stryker Endoscopy shall have sole discretion to determine whether the Stryker Endoscopy Equipment shall be repaired or replaced.\nUse of loaner equipment to replace the Stryker Endoscopy Equipment during repair, except where the item is handled through Stryker Endoscopy s repair / replace program; and\nPrioritized repairs over non-contracted customers, with no additional administration or approval process.\nWill provide proprietary software upgrades.\nWill provide a system image DVD, of the current version, to reimage disk drive prior to return for repair.\nAny hard drives removed from the system will remain VA property.\n24-hour replacements and loaners\nCoverage for mandatory calibrations on insufflators\nQuality inspection on all repairs in accordance with FDA Quality System Regulations\nFree shipping to and from Boise VA Medical Center\n\nComponents include but are not limited to technical support 7 days per week, 24 hours per day. Support and any work done must be warranted by Stryker. The support is for the equipment below:\n\nPerformance Monitoring. Performance will be monitored by periodic inspections and observation of work. Work will be observed by the POC, or designee, during performance of scheduled maintenance service and inspections and/or during repair service. Equipment operators will be contacted to report on contractor performance when POC, or designee, is not available.\nSecurity Requirements. The C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).\nNo Government supplied Equipment or Information is required or anticipated.\nOther Pertinent Information or Special Considerations.\na. Identification of Possible Follow-on Work. No Follow-on work is anticipated.\nb. Identification of Potential Conflicts of Interest (COI). No Known COI\nc. Identification of Non-Disclosure Requirements. Contractors will not have access to Sensitive or Proprietary Information. Any Patient Information that may have been observed during the course of the work must not be discussed, or shared, with anyone beyond the Service Staff or any person who does not have the need to know such information.\nd. Packaging, Packing and Shipping Instructions. N/A\ne. Inspection and Acceptance Criteria. POC, or designee, will verify that the unit is working within Manufacture s specifications after completion of service or repair.\nRisk Control. The Contractor shall obtain all necessary licenses and/or permits required to perform this work. The contractor shall take all precautions necessary to protect people and property from injury or damage during the performance of this contract. The contractor shall be responsible for any injury to any contractor representative, or others, as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by the contractor s fault or negligence.\nIf Patient Information may have been observed during the performance of work, the Contractor will not discuss any patient issues that may have been observed during the course of the work.\nPlace of Performance. All services will be performed at Boise VA Medical Center (BVAMC) Operating Room (OR).\nPeriod of Performance. Base year 10/23/2025 10/22/2026, plus four option years.\nDelivery Schedule. Service Reports will be emailed or faxed to POC by the 5th workday after completion of the work.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26025Q0811","place_of_performance":{"zip":"83702","city":{"code":"8700","name":"Boise"},"state":{"code":"ID","name":"Idaho"},"street":"Department of Veterans Affairs Boise VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"500 W. Fort St."},"product_service_code":"J065"}],"due_at":"2025-08-18T22:00:00Z","due_date":"2025-08-18","closes_at":"2025-08-18T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-06T02:20:19.519223Z","principal_notice_id":"3ed7998a1bc748f89457ed08e33de937","description":{"text":"SOURCES SOUGHT NOTICE\n\nThis is a Sources Sought NOTICE (SSN) ONLY. The U.S. Government is conducting market research only to determine the availability of qualified sources capable of providing maintenance and repair services to ensure proper operation of Stryker Endoscopes at the Boise VA Medical Center. Potential Contractors are invited to provide a response via e-mail to Contract Specialist at tracy.heath@va.gov by 08/18/2025 15:00 (PT). Responses will be used to determine the appropriate strategy for a potential acquisition. Please clearly identify any information your company considers sensitive or proprietary. This notice is issued solely for information and planning purposes - it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes in response to this sources sought synopsis. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ, if any is issued.\n\nBACKGROUND: The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.\n\nNAICS: 811210, Electronic & Precision Equipment Repair and Maintenance.\n\nInterested potential Contractors please provide the following.\n\n1) Company Name, address, point of contact, phone number, email address, and UEI\n\nPlease indicate business size:\nSmall Disadvantage Business (SDB)____\n8(a)____\nHistorically Underutilized Business Zone (HUBZone)____\nService-Disabled Veteran-Owned Small Business (SDVOSB)____\nVeteran-Owned Small Business (VOSB)_____\nEconomically Disadvantaged Women-Owned Small Business (EDWOSB)_____\nWomen-Owned Small Business concerns (WOSB)_____\nSmall Business_____\nLarge Business_____\n\nPlease state if you possess a Federal Supply Schedule (FSS)______. Please state if your FSS Schedule is under Group 66 III Cat 605-2A________\n\n2) Please submit a brief capability statement (maximum three pages) with enough information to demonstrate to the Veterans Affairs that you have the enough resources, personnel, and experience to perform on-site preventative maintenance and repair services as required in the attached Draft Statement of Work.\n\n**Draft Statement of Work\n\nSTATEMENT OF WORK (SOW)\nStryker Pro-Care Maintenance\nBackground. The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment. Qualified Service is required to maintain the devices to Manufacturer s specifications. The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service. Sensitive Patient Records will not be viewed because of this requirement. Access to the controlled area will be provided by POC, OR Staff, Police Service, or another designated and authorized BVAMC employee.\nScope.\nContractor to provide on-site preventative maintenance and repair services on the same day as required, included but not limited to all labor, certified service technicians, travel, living expenses, maintenance materials and service, and tools, and necessary parts to perform the required service in accordance with the manufacturer s service manuals for the equipment listed herein. This requirement is subject to inspection and verification by a government representative.\nAn unlimited number of repairs of the Stryker Endoscopy Equipment, including labor and parts, regardless of fault, except as provided in subsection (b) below.\nReplacement equipment for the Stryker Endoscopy Equipment, if necessary. Stryker Endoscopy shall have sole discretion to determine whether the Stryker Endoscopy Equipment shall be repaired or replaced.\nUse of loaner equipment to replace the Stryker Endoscopy Equipment during repair, except where the item is handled through Stryker Endoscopy s repair / replace program; and\nPrioritized repairs over non-contracted customers, with no additional administration or approval process.\nWill provide proprietary software upgrades.\nWill provide a system image DVD, of the current version, to reimage disk drive prior to return for repair.\nAny hard drives removed from the system will remain VA property.\n24-hour replacements and loaners\nCoverage for mandatory calibrations on insufflators\nQuality inspection on all repairs in accordance with FDA Quality System Regulations\nFree shipping to and from Boise VA Medical Center\n\nComponents include but are not limited to technical support 7 days per week, 24 hours per day. Support and any work done must be warranted by Stryker. The support is for the equipment below:\n\nPerformance Monitoring. Performance will be monitored by periodic inspections and observation of work. Work will be observed by the POC, or designee, during performance of scheduled maintenance service and inspections and/or during repair service. Equipment operators will be contacted to report on contractor performance when POC, or designee, is not available.\nSecurity Requirements. The C&A requirements do not apply, and a Security Accreditation Package is not required.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).\nNo Government supplied Equipment or Information is required or anticipated.\nOther Pertinent Information or Special Considerations.\na. Identification of Possible Follow-on Work. No Follow-on work is anticipated.\nb. Identification of Potential Conflicts of Interest (COI). No Known COI\nc. Identification of Non-Disclosure Requirements. Contractors will not have access to Sensitive or Proprietary Information. Any Patient Information that may have been observed during the course of the work must not be discussed, or shared, with anyone beyond the Service Staff or any person who does not have the need to know such information.\nd. Packaging, Packing and Shipping Instructions. N/A\ne. Inspection and Acceptance Criteria. POC, or designee, will verify that the unit is working within Manufacture s specifications after completion of service or repair.\nRisk Control. The Contractor shall obtain all necessary licenses and/or permits required to perform this work. The contractor shall take all precautions necessary to protect people and property from injury or damage during the performance of this contract. The contractor shall be responsible for any injury to any contractor representative, or others, as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by the contractor s fault or negligence.\nIf Patient Information may have been observed during the performance of work, the Contractor will not discuss any patient issues that may have been observed during the course of the work.\nPlace of Performance. All services will be performed at Boise VA Medical Center (BVAMC) Operating Room (OR).\nPeriod of Performance. Base year 10/23/2025 10/22/2026, plus four option years.\nDelivery Schedule. Service Reports will be emailed or faxed to POC by the 5th workday after completion of the work.","html":"SOURCES SOUGHT NOTICE\n\nThis is a Sources Sought NOTICE (SSN) ONLY. The U.S. Government is conducting market research only to determine the availability of qualified sources capable of providing maintenance and repair services to ensure proper operation of Stryker Endoscopes at the Boise VA Medical Center. Potential Contractors are invited to provide a response via e-mail to Contract Specialist at tracy.heath@va.gov by 08/18/2025 15:00 (PT). Responses will be used to determine the appropriate strategy for a potential acquisition. Please clearly identify any information your company considers sensitive or proprietary. This notice is issued solely for information and planning purposes - it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes in response to this sources sought synopsis. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ, if any is issued. \n\nBACKGROUND: The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment.  Qualified Service is required to maintain the devices to Manufacturer s specifications.  The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.\n\nNAICS: 811210, Electronic & Precision Equipment Repair and Maintenance.\n\nInterested potential Contractors please provide the following.\n\n1) Company Name, address, point of contact, phone number, email address, and UEI\n\nPlease indicate business size: \nSmall Disadvantage Business (SDB)____ \n8(a)____\nHistorically Underutilized Business Zone (HUBZone)____\nService-Disabled Veteran-Owned Small Business (SDVOSB)____\nVeteran-Owned Small Business (VOSB)_____\nEconomically Disadvantaged Women-Owned Small Business (EDWOSB)_____\nWomen-Owned Small Business concerns (WOSB)_____\nSmall Business_____\nLarge Business_____\n\nPlease state if you possess a Federal Supply Schedule (FSS)______. Please state if your FSS Schedule is under Group 66 III Cat 605-2A________\n\n2) Please submit a brief capability statement (maximum three pages) with enough information to demonstrate to the Veterans Affairs that you have the enough resources, personnel, and experience to perform on-site preventative maintenance and repair services as required in the attached Draft Statement of Work.\n\n**Draft Statement of Work\n\nSTATEMENT OF WORK (SOW)\nStryker Pro-Care Maintenance\nBackground.  The Biomedical Department does not have the necessary specialized tools and training to perform maintenance and repair of Styker Operating Room (OR) Endoscopy equipment.  Qualified Service is required to maintain the devices to Manufacturer s specifications.  The equipment is located at the Boise VA Medical Centers (BVAMC) OR Service.  Sensitive Patient Records will not be viewed because of this requirement.  Access to the controlled area will be provided by POC, OR Staff, Police Service, or another designated and authorized BVAMC employee.\nScope.  \nContractor to provide on-site preventative maintenance and repair services on the same day as required, included but not limited to all labor, certified service technicians, travel, living expenses, maintenance materials and service, and tools, and necessary parts to perform the required service in accordance with the manufacturer s service manuals for the equipment listed herein. This requirement is subject to inspection and verification by a government representative.\nAn unlimited number of repairs of the Stryker Endoscopy Equipment, including labor and parts, regardless of fault, except as provided in subsection (b) below.\nReplacement equipment for the Stryker Endoscopy Equipment, if necessary. Stryker Endoscopy shall have sole discretion to determine whether the Stryker Endoscopy Equipment shall be repaired or replaced.\nUse of loaner equipment to replace the Stryker Endoscopy Equipment during repair, except where the item is handled through Stryker Endoscopy s repair / replace program; and\nPrioritized repairs over non-contracted customers, with no additional administration or approval process.\nWill provide proprietary software upgrades. \nWill provide a system image DVD, of the current version, to reimage disk drive prior to return for repair.\nAny hard drives removed from the system will remain VA property. \n24-hour replacements and loaners\nCoverage for mandatory calibrations on insufflators\nQuality inspection on all repairs in accordance with FDA Quality System Regulations\nFree shipping to and from Boise VA Medical Center\n\nComponents include but are not limited to technical support 7 days per week, 24 hours per day. Support and any work done must be warranted by Stryker. The support is for the equipment below: \n\n\nPerformance Monitoring. Performance will be monitored by periodic inspections and observation of work.  Work will be observed by the POC, or designee, during performance of scheduled maintenance service and inspections and/or during repair service.  Equipment operators will be contacted to report on contractor performance when POC, or designee, is not available.\nSecurity Requirements.  The C&A requirements do not apply, and a Security Accreditation Package is not required.\n  \nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).  \nNo Government supplied Equipment or Information is required or anticipated.\nOther Pertinent Information or Special Considerations.  \n a.  Identification of Possible Follow-on Work.  No Follow-on work is anticipated.\n b.  Identification of Potential Conflicts of Interest (COI).  No Known COI\n c.  Identification of Non-Disclosure Requirements.  Contractors will not have access to Sensitive or Proprietary Information.  Any Patient Information that may have been observed during the course of the work must not be discussed, or shared, with anyone beyond the Service Staff or any person who does not have the need to know such information.\n d.  Packaging, Packing and Shipping Instructions.  N/A\n e.  Inspection and Acceptance Criteria.  POC, or designee, will verify that the unit is working within Manufacture s specifications after completion of service or repair.\nRisk Control.  The Contractor shall obtain all necessary licenses and/or permits required to perform this work. The contractor shall take all precautions necessary to protect people and property from injury or damage during the performance of this contract.  The contractor shall be responsible for any injury to any contractor representative, or others, as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by the contractor s fault or negligence.\nIf Patient Information may have been observed during the performance of work, the Contractor will not discuss any patient issues that may have been observed during the course of the work.\nPlace of Performance.  All services will be performed at Boise VA Medical Center (BVAMC) Operating Room (OR).\nPeriod of Performance.  Base year 10/23/2025   10/22/2026, plus four option years.\nDelivery Schedule.  Service Reports will be emailed or faxed to POC by the 5th workday after completion of the work.","origin":"detail"},"contacts":[{"name":"Tracy Heath","role":"primary","email":"tracy.heath@va.gov","phone":"253-888-4903","title":"Contract Specialist"}],"place_of_performance":{"zip":"83702","city":{"code":"8700","name":"Boise"},"state":{"code":"ID","name":"Idaho"},"street":"Department of Veterans Affairs Boise VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"500 W. Fort St."},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"f7c8d7c03e3d439e8daf2819d50fafb3","name":"36C26025Q0811.docx","kind":"file","mime_type":".docx","size_bytes":178579,"posted_at":"2025-08-05T21:24:46.973Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f7c8d7c03e3d439e8daf2819d50fafb3/download","mirrored":false}],"awards":[],"related":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C26027R0021","latest_notice_id":"33ec88e000334f018234fcabcf0c4e88","title":"Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center","solicitation_number":"36C26027R0021","notice_type":"o","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-11-25","notices":6,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Mann-Grandstaff VA Medical Center","site_key":"mann-grandstaff-va-medical-center-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open":[{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0063","latest_notice_id":"57c32e663caa45e58aecf5d9fcc6fe70","title":"J065--ALCON CONSTELLATION LXT AND EMBEDDED LASERS & ALCON CENTURION VISION PHACOEMULSIFICATION PMI SVCS","solicitation_number":"36C26227Q0063","notice_type":"k","first_type":"r","first_posted":"2026-10-21","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"IHS1532582","latest_notice_id":"e43a8d0bba28406f8903b22a88a9e950","title":"Ventilator Full-Service Maintenance","solicitation_number":"IHS1532582","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"811210","psc":"J065","set_aside":"ISBEE","state":"OK","county":"40031","county_name":"Comanche County","city":"4041850","city_name":"Lawton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":63,"indexable":false}