Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,509 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Blood Bank Cost Per Test

36C25726Q0775

Department of Veterans Affairs, 257-Network Contract Office 17. Testing Laboratories and Services.

Response deadline

July 27, 2026 at 10:00 AM EDT

Closed 122 days ago. Posted July 15, 2026, first published July 15, 2026. Scheduled to archive September 25, 2026.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2026

34 like it are open now in testing laboratories and services

All 34 open in testing laboratories and services

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 541380 (testing laboratories and services), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation has been published under this number yet. The sources sought of July 15, 2026 is the earliest notice of the purchase.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy. I. General Information - Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX. - Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas. - Anticipated NAICS: 541380 Testing Laboratories and Services - Anticipated PSC: 6640 Laboratory Equipment and Supplies. The Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS. II. Description of Requirement Transfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens. Contract type will be cost per test with analyzer included. The contemplated purchase includes, at a minimum: The Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer. Estimated quantities shown below are for annual requirements. Group I Estimated Yearly Test Volume: Assay Est. Annual Test Volume ABO/RH 7,800 Antibody Screen 4,000 Antibody Identification (with Selected Cell Panels capabilities) 60 Direct Antiglobulin Test-IgG, C3d 200 Immediate Spin Crossmatch 100 AHG Crossmatch 400 ABD Group Forward type 500 O Group Forward type 500 Group II Estimated Yearly Reagents & Consumables Requirements: Reagents & Consumables Est. Annual Volume A/B Group 500 A/B/D Group 500 A/B/D Mono & Reverse Group 7,800 DAT Card (IgG & C3d) 200 Anti-IgG Card 4,000 Buffered Gel Card 200 7% Bovine Serum Albumin 32 Evaporation Caps for Reagent Red Cells 2 Diluent 2 4 Diluent 2 Plus 7 Group II Estimated Yearly Traditional Reagents Requirements: Traditional Reagents Standing Order with Scheduled Delivery Schedule. Est. Annual Volume 0.8% A1 Cell and B Cell (0.8% Affirmagen) 78 0.8% Panel B 13 0.8% Panel C 13 0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen) 78 Daily QC Kit 52 Location: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216. Delivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216. III. Performance requirements: Performance Requirements: The following are required: Installation Requirements: Deliver, install, and set up the instrument (automated analyzer) and components. Deliver one manual testing platform (equipment) Provide test validation guidance and validation supplies. Testing Requirements: ABO/RH Antibody Screen (3 Cells) Direct Antiglobulin Test (DAT) Antibody Identification (with Selected Cell Panels Capabilities) Immediate Spin Crossmatch AHG Crossmatch Antigen Testing Capabilities Antibody Titration (with automated serial dilutions) Capabilities System Requirements: The system must contain continuous, random and STAT access technology. The system must have minimal daily maintenance and tracking capabilities when maintenance has been completed. The system should have technology to prevent sample carryover. The system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime. Sample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting. The system must have automatic cap, clot and liquid level detection capabilities. The system must not utilize proprietary system liquids. The system must offer up to 24 hours of walkaway time. When operational, the system must always be in a ready mode and at no time go into a hibernation or sleep state. The system must be able to run selected cell antibody identification panels. The optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results. A fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height. Connectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.) System is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry. IV. Submission Instructions Interested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time. - Teresa Arzola   - Email: Teresa.arzola@va.gov   - Subject line: Sources Sought Blood Bank Cost Per Test Reagents VA North Texas HCS   No telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted). Submission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 15, 2026

    Sources sought

    Due July 27, 2026 at 10:00 AM EDT. SAM.gov, notice 2f62b5569edd4719892853e693ce99a1

    1 revision on SAM
    • July 15, 2026: publish, sources sought
  2. July 15, 2026

    Sources sought

    Due July 27, 2026 at 10:00 AM EDT. SAM.gov, notice fe2b06d2e691467ea0b25be95a51c3f9

    1 revision on SAM
    • July 15, 2026: publish, sources sought

Points of contact