{"canonical":"https://sealedbidder.com/opportunities/36c25726q0775","key":"36C25726Q0775","url":"https://sealedbidder.com/opportunities/36c25726q0775","title":"6640-- Blood Bank Cost Per Test","solicitation_number":"36C25726Q0775","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-27T14:00:00Z","first_posted":"2026-07-15","last_posted":"2026-07-15","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541380","psc":"6640","set_aside":null,"place_state":"TX","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"48113","place_county_name":"Dallas County","place_city":"4819000","place_city_name":"Dallas","winner":null,"award_amount":null,"publications":[{"notice_id":"2f62b5569edd4719892853e693ce99a1","title":"6640-- Blood Bank Cost Per Test","solicitation_number":"36C25726Q0775","notice_type":"r","base_type":"r","posted":"2026-07-15","posted_at":"2026-07-15T14:27:29.173Z","due_at":"2026-07-27T14:00:00Z","due_date":"2026-07-27","cancelled":false,"archived":true,"archive_date":"2026-09-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2f62b5569edd4719892853e693ce99a1/view","enriched":true,"history":[{"index":1,"title":"6640-- Blood Bank Cost Per Test","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-15T14:27:29.173Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f62b5569edd4719892853e693ce99a1","solicitation_number":"36C25726Q0775"}]},{"notice_id":"fe2b06d2e691467ea0b25be95a51c3f9","title":"6640-- Blood Bank Cost Per Test","solicitation_number":"36C25726Q0775","notice_type":"r","base_type":"r","posted":"2026-07-15","posted_at":"2026-07-15T14:27:28.339Z","due_at":"2026-07-27T14:00:00Z","due_date":"2026-07-27","cancelled":false,"archived":true,"archive_date":"2026-09-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fe2b06d2e691467ea0b25be95a51c3f9/view","enriched":true,"history":[{"index":1,"title":"6640-- Blood Bank Cost Per Test","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-15T14:27:28.339Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fe2b06d2e691467ea0b25be95a51c3f9","solicitation_number":"36C25726Q0775"}]}],"latest_notice_id":"fe2b06d2e691467ea0b25be95a51c3f9","first_type":"r","notices":[{"dates":{"posted":"2026-07-15","posted_at":"2026-07-15T14:27:29.173Z","created_at":"2026-07-15T14:27:26.869Z","modified_at":"2026-07-15T14:27:29.173Z","response_deadline":{"raw":"2026-07-27T09:00:00-05:00","utc":"2026-07-27T14:00:00Z","date":"2026-07-27","time":"09:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2f62b5569edd4719892853e693ce99a1/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"6640-- Blood Bank Cost Per Test","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-09-25","archive_type":"auto_custom"},"history":[{"index":1,"title":"6640-- Blood Bank Cost Per Test","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-15T14:27:29.173Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f62b5569edd4719892853e693ce99a1","solicitation_number":"36C25726Q0775"}],"contacts":[{"name":"Teresa Arzola","role":"primary","email":"teresa.arzola@va.gov","phone":"5441 Babcock Rd. Ste. 302","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2f62b5569edd4719892853e693ce99a1","lineage_id":"2f62b5569edd4719892853e693ce99a1","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T02:46:58.147734600Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"95a38dcc808142de51137f8402e52049-29\"","fetched_at":"2026-09-24T04:21:46.782462570Z","row_sha256":"0fb077f74f1689aa9aa38874ec6873f1de4209753251718f0b83593e94b1c017","last_modified":"2026-09-24T03:30:47Z"},"updated_at":"2026-09-24T04:21:46.782462570Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380   Testing Laboratories and Services\n- Anticipated PSC: 6640   Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer. \nEstimated quantities shown below are for annual requirements.\nGroup I   Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH \n7,800\nAntibody Screen \n4,000\nAntibody Identification (with \nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II   Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group \n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II   Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents   Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216. \nIII. Performance requirements:\nPerformance Requirements: The following are required: \nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components. \nDeliver one manual testing platform (equipment) \nProvide test validation guidance and validation supplies. \n\nTesting Requirements: \nABO/RH \nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover. \nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or  sleep  state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â \n- Email: Teresa.arzola@va.gov Â \n- Subject line:  Sources Sought   Blood Bank Cost Per Test Reagents   VA North Texas HCS  Â \n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380 Testing Laboratories and Services\n- Anticipated PSC: 6640 Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer.\nEstimated quantities shown below are for annual requirements.\nGroup I Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH\n7,800\nAntibody Screen\n4,000\nAntibody Identification (with\nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group\n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nIII. Performance requirements:\nPerformance Requirements: The following are required:\nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components.\nDeliver one manual testing platform (equipment)\nProvide test validation guidance and validation supplies.\n\nTesting Requirements:\nABO/RH\nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover.\nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or sleep state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â\n- Email: Teresa.arzola@va.gov Â\n- Subject line: Sources Sought Blood Bank Cost Per Test Reagents VA North Texas HCS Â\n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25726Q0775","place_of_performance":{"zip":"75216","city":{"name":"Dallas"},"state":{"code":"TX"},"street":"Department of Veterans Affairs Dallas VA North Texas Health Care System ATTN: Pathology & Laboratory Service 4500 S. Lancaster Rd.","country":{"code":"USA"}},"product_service_code":"6640"},{"dates":{"posted":"2026-07-15","posted_at":"2026-07-15T14:27:28.339Z","created_at":"2026-07-15T14:27:26.122Z","modified_at":"2026-07-15T14:27:28.339Z","response_deadline":{"raw":"2026-07-27T09:00:00-05:00","utc":"2026-07-27T14:00:00Z","date":"2026-07-27","time":"09:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fe2b06d2e691467ea0b25be95a51c3f9/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"6640-- Blood Bank Cost Per Test","agency":{"office":{"code":"36C257","name":"257-NETWORK CONTRACT OFFICE 17 (36C257)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-09-25","archive_type":"auto_custom"},"history":[{"index":1,"title":"6640-- Blood Bank Cost Per Test","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-15T14:27:28.339Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"fe2b06d2e691467ea0b25be95a51c3f9","solicitation_number":"36C25726Q0775"}],"contacts":[{"name":"Teresa Arzola","role":"primary","email":"teresa.arzola@va.gov","phone":"5441 Babcock Rd. Ste. 302","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"fe2b06d2e691467ea0b25be95a51c3f9","lineage_id":"fe2b06d2e691467ea0b25be95a51c3f9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T02:56:04.674783933Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"95a38dcc808142de51137f8402e52049-29\"","fetched_at":"2026-09-24T04:21:46.782462570Z","row_sha256":"279f1e9294fb68d7487f20c7a13a7e23feadfeb0755339f1198b1b333fb668e9","last_modified":"2026-09-24T03:30:47Z"},"updated_at":"2026-09-24T04:21:46.782462570Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380   Testing Laboratories and Services\n- Anticipated PSC: 6640   Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer. \nEstimated quantities shown below are for annual requirements.\nGroup I   Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH \n7,800\nAntibody Screen \n4,000\nAntibody Identification (with \nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II   Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group \n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II   Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents   Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216. \nIII. Performance requirements:\nPerformance Requirements: The following are required: \nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components. \nDeliver one manual testing platform (equipment) \nProvide test validation guidance and validation supplies. \n\nTesting Requirements: \nABO/RH \nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover. \nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or  sleep  state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â \n- Email: Teresa.arzola@va.gov Â \n- Subject line:  Sources Sought   Blood Bank Cost Per Test Reagents   VA North Texas HCS  Â \n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380 Testing Laboratories and Services\n- Anticipated PSC: 6640 Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer.\nEstimated quantities shown below are for annual requirements.\nGroup I Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH\n7,800\nAntibody Screen\n4,000\nAntibody Identification (with\nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group\n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nIII. Performance requirements:\nPerformance Requirements: The following are required:\nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components.\nDeliver one manual testing platform (equipment)\nProvide test validation guidance and validation supplies.\n\nTesting Requirements:\nABO/RH\nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover.\nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or sleep state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â\n- Email: Teresa.arzola@va.gov Â\n- Subject line: Sources Sought Blood Bank Cost Per Test Reagents VA North Texas HCS Â\n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C25726Q0775","place_of_performance":{"zip":"75216","city":{"name":"Dallas"},"state":{"code":"TX"},"street":"Department of Veterans Affairs Dallas VA North Texas Health Care System ATTN: Pathology & Laboratory Service 4500 S. Lancaster Rd.","country":{"code":"USA"}},"product_service_code":"6640"}],"due_at":"2026-07-27T14:00:00Z","due_date":"2026-07-27","closes_at":"2026-07-27T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-26T05:49:22.960947Z","principal_notice_id":"fe2b06d2e691467ea0b25be95a51c3f9","description":{"text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380 Testing Laboratories and Services\n- Anticipated PSC: 6640 Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer.\nEstimated quantities shown below are for annual requirements.\nGroup I Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH\n7,800\nAntibody Screen\n4,000\nAntibody Identification (with\nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group\n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nIII. Performance requirements:\nPerformance Requirements: The following are required:\nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components.\nDeliver one manual testing platform (equipment)\nProvide test validation guidance and validation supplies.\n\nTesting Requirements:\nABO/RH\nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover.\nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or sleep state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â\n- Email: Teresa.arzola@va.gov Â\n- Subject line: Sources Sought Blood Bank Cost Per Test Reagents VA North Texas HCS Â\n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","html":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for quote (RFQ), request for proposal (RFP), or invitation for bid (IFB). No solicitation is currently available. This Sources Sought is issued solely for information and planning purposes to conduct market research and determine the availability and capability of qualified sources prior to determining the appropriate acquisition strategy.\n\nI. General Information\n\n- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.\n- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.\n- Anticipated NAICS: 541380   Testing Laboratories and Services\n- Anticipated PSC: 6640   Laboratory Equipment and Supplies.\n\nThe Government is seeking to identify responsible vendors capable of providing Blood Bank Cost Per Test Reagents, brand name or equal, configured and supported with Government owned Ortho Workstations in the Transfusion Medicine Unit Room 1B-306, Pathology and Laboratory Medicine Services at VANTHCS.\nII. Description of Requirement\nTransfusion Medicine Unit, Pathology and Laboratory Medicine Services (P&LMS) at the VA North Texas Health Care System (VANTHCS), Dallas, TX is seeking a fully automated gel instrument and reagents to perform Type & Screen testing with antibody ID panels, Direct Antiglobulin test, IS and AHG crossmatches and the capability to test for antigens.\nContract type will be cost per test with analyzer included.\nThe contemplated purchase includes, at a minimum:\nThe Contractor shall provide reagents, consumables, and supplies as requested by VANTHCS staff to perform blood bank testing for the analyzer. \nEstimated quantities shown below are for annual requirements.\nGroup I   Estimated Yearly Test Volume:\nAssay\nEst. Annual Test Volume\nABO/RH \n7,800\nAntibody Screen \n4,000\nAntibody Identification (with \nSelected Cell Panels capabilities)\n60\nDirect Antiglobulin Test-IgG, C3d\n200\nImmediate Spin Crossmatch\n100\nAHG Crossmatch\n400\nABD Group Forward type\n500\nO Group Forward type\n500\n\nGroup II   Estimated Yearly Reagents & Consumables Requirements:\nReagents & Consumables\nEst. Annual Volume\nA/B Group \n500\nA/B/D Group\n500\nA/B/D Mono & Reverse Group\n7,800\nDAT Card (IgG & C3d)\n200\nAnti-IgG Card\n4,000\nBuffered Gel Card\n200\n7% Bovine Serum Albumin\n32\nEvaporation Caps for Reagent Red Cells\n2\nDiluent 2\n4\nDiluent 2 Plus\n7\n\nGroup II   Estimated Yearly Traditional Reagents Requirements:\nTraditional Reagents   Standing Order with Scheduled Delivery Schedule.\nEst. Annual Volume\n0.8% A1 Cell and B Cell (0.8% Affirmagen)\n78\n0.8% Panel B\n13\n0.8% Panel C\n13\n0.8% Antibody Screen Cells 3 Cells (0.8% Surgiscreen)\n78\nDaily QC Kit\n52\n\nLocation: The analyzer shall be located, and testing will be performed in Transfusion Medicine Unit, Room 1B-306, Pathology & Laboratory Medicine Service, VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216.\nDelivery: Within 60 days of the contract award the vendor will deliver the analyzer and reagents to VA North Texas Health Care System, 4500 S. Lancaster Rd., Dallas, TX 75216. \nIII. Performance requirements:\nPerformance Requirements: The following are required: \nInstallation Requirements:\nDeliver, install, and set up the instrument (automated analyzer) and components. \nDeliver one manual testing platform (equipment) \nProvide test validation guidance and validation supplies. \n\nTesting Requirements: \nABO/RH \nAntibody Screen (3 Cells)\nDirect Antiglobulin Test (DAT)\nAntibody Identification (with Selected Cell Panels Capabilities)\nImmediate Spin Crossmatch\nAHG Crossmatch\nAntigen Testing Capabilities\nAntibody Titration (with automated serial dilutions) Capabilities\n\nSystem Requirements:\nThe system must contain continuous, random and STAT access technology.\nThe system must have minimal daily maintenance and tracking capabilities when maintenance has been completed.\nThe system should have technology to prevent sample carryover. \nThe system must feature error-proof reagent and commodity design with built-in safeguards to prevent reagent mix-ups, probe crashes and unnecessary downtime.\nSample carriers must be capable of utilizing different tube sizes in one carrier, thus avoiding the need for pre-analytic sorting.\nThe system must have automatic cap, clot and liquid level detection capabilities.\nThe system must not utilize proprietary system liquids.\nThe system must offer up to 24 hours of walkaway time.\nWhen operational, the system must always be in a ready mode and at no time go into a hibernation or  sleep  state.\nThe system must be able to run selected cell antibody identification panels.\nThe optical resolution of the onboard camera must be at least 5-megapixel resolution down to 32 x 32 microns and store a digital image of both the front and back of each gel card to record test results.\nA fully loaded waste container shall not weigh more than 11 lbs. and be accessible at waist height.\n\nConnectivity Requirements: (Note: Does not use the following software: Windows XP Embedded Service Pack 3, Windows Server 2003 or Windows XP.)\nSystem is fully interfaced (bidirectional) with VistA via Data Innovations: System accommodates reporting through Data Innovations (DI) to eliminate the need for manual data entry.\n\nIV. Submission Instructions\nInterested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by July 27, 2026, by 9:00 AM Central Standard Time.\n\n- Teresa Arzola Â \n- Email: Teresa.arzola@va.gov Â \n- Subject line:  Sources Sought   Blood Bank Cost Per Test Reagents   VA North Texas HCS  Â \n\nNo telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).\n\nSubmission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.","origin":"detail"},"contacts":[{"name":"Teresa Arzola","role":"primary","email":"teresa.arzola@va.gov","phone":"5441 Babcock Rd. Ste. 302","title":"Contract Specialist"}],"place_of_performance":{"zip":"75216","city":{"name":"Dallas"},"state":{"code":"TX"},"street":"Department of Veterans Affairs Dallas VA North Texas Health Care System ATTN: Pathology & Laboratory Service 4500 S. Lancaster Rd.","country":{"code":"USA"}},"office_address":{"zip":"78240","city":"San Antonio","state":"TX","country":"USA"},"naics_codes":["541380"],"award":null,"attachments":[{"resource_id":"393fafd72e454a9a9d1da0542e79b536","name":"36C25726Q0775.docx","kind":"file","mime_type":".docx","size_bytes":20686,"posted_at":"2026-07-15T14:27:28.339Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/393fafd72e454a9a9d1da0542e79b536/download","mirrored":false},{"resource_id":"f9a65b30bdf544b7a9a66d79f5ddcd98","name":"36C25726Q0775.docx","kind":"file","mime_type":".docx","size_bytes":20686,"posted_at":"2026-07-15T14:27:29.173Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f9a65b30bdf544b7a9a66d79f5ddcd98/download","mirrored":false}],"awards":[],"related":[{"key":"36C25727R0012","latest_notice_id":"1e9cdf40734c4926bc09cfc12390022b","title":"V225--Amarillo and Big Springs Air Ambulance","solicitation_number":"36C25727R0012","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"621910","psc":"V225","set_aside":"SDVOSBC","state":"TX","county":"48375","county_name":"Potter County","city":"4803000","city_name":"Amarillo","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C25727Q0027","latest_notice_id":"0d1de2b7c20d45b99cb735b3d4beccd3","title":"WTX Elevator Inspections and Load Testing Services - Amended","solicitation_number":"36C25727Q0027","notice_type":"k","first_type":"k","first_posted":"2026-10-19","last_posted":"2026-11-20","notices":4,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238290","psc":"J039","set_aside":"SDVOSBC","state":"TX","county":"48227","county_name":"Howard County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q0104","latest_notice_id":"9c3ddb4326164d4fa71ad956d4194f7c","title":"6515--36C257-27-AP-0953 Prosthetic STX 671 O2 Equipment (VA-27-00016458)","solicitation_number":"36C25727Q0104","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339113","psc":"6515","set_aside":"SDVOSBC","state":"TX","county":"48029","county_name":"Bexar County","city":"4865000","city_name":"San Antonio","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"36C25727Q0052","latest_notice_id":"366f45568a854b0cad0c51cb35650156","title":"Sit-to-Stand Lift","solicitation_number":"36C25727Q0052","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"339112","psc":"6515","set_aside":null,"state":"TX","county":null,"county_name":null,"city":"4819000","city_name":"Dallas","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"75N98027Q00088","latest_notice_id":"3b43b8638fd54df5944bd42be1a2a18d","title":"Tissue Chip Testing Research Services","solicitation_number":"75N98027Q00088","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"B529","set_aside":null,"state":"TX","county":"48041","county_name":"Brazos County","city":"4815976","city_name":"College Station","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":34,"indexable":false}