Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,626 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Award notice, service-disabled veteran-owned small business set-aside, first published as presolicitation

Chiller 7 & Pumps Replacement

36C24926Q0155

Department of Veterans Affairs, 249-Network Contract Office 9. Plumbing, Heating, and Air-Conditioning Contractors.

Awarded

Accord Federal Services, LLC

$697,697.16 obligated so far on USAspending

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one was awarded in 2026

58 like it are open now in plumbing, heating, and air-conditioning contractors

All 58 open in plumbing, heating, and air-conditioning contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Award notice. Who won, when, and for how much. Glossary
Who may compete
Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. Open SDVOSB opportunities
Time to respond
Bidders had 32 days from the day the solicitation was posted, March 12, 2026, to the deadline. The deadline moved once: it was first March 30, 2026 and ended as April 13, 2026.
How it ended
Awarded to Accord Federal Services, LLC on April 30, 2026, 17 days after offers were due. The contracting office reported 5 offers (competed under simplified acquisition procedures).

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov with the solicitation of March 20, 2026.

Contractor Questions and Government Answers Government Answers provided to the best of our knowledge, Contractor is responsible for field verification of all existing conditions to confirm accuracy.  A site visit is highly recommended. Is this a brand-new contract OR is (was) there an incumbent performing these services? This is a new, stand alone requirement for the replacement of Chiller #7. If not brand-new, can you please provide the current/previous contract number? N/A as this is a brand new contract. The following questions (4-15) are for some clarification on the SOW: Provide new Chiller: York Chiller Air Cooled Screw Chiller - Model: YVAA0213. Is this a Sole Source requirement or are or equal chillers acceptable? LIKE FOR LIKE What is the specific tonnage required for the chiller? 212.1 What is the operating conditions for the chiller: Entering/Leaving water temperature, GPM flow rate, voltage, amperage and disconnect size? EWT 54 Degrees and LWT 44 Degrees, GPM 510-520,460 V and 400-450A Disconnect. Where is the disconnecting means for the chiller? Beside the chiller on the ACRE building roof. Provide labor and equipment, on a Saturday, to demolish existing chiller #7 and with the use of a crane, remove from roof and haul chiller off site. Where on the roof is the chiller located? Roof of the ACRE Building Where is the crane to be set up? In between the VA Hospital and Vanderbilt Hospital Where is access for crane to be located on site? North end of the VA Hospital Is there any time frame for the crane to be on site? Coordinate with COR Set structural steel additional pieces, piping, and accessories on roof. What is the steel that is required? Is it to be galvanized? What is the size of the steel members? Are they beams, angle, tube, etc? Existing Steel is galvanized I-beam 16 main and 8 crossbeam. Contractor responsible for appropriate new steel required for safe and complete chiller installation in adherence with all applicable codes and regulations. Provide labor, material, and tools to fabricate and reconfigure existing structural steel due to the fact the new chiller is wider than the existing. What reconfiguration is required? Same location New isolation springs will be provided and installed prior to setting up the chiller. Are isolators to be provided by VA or Contractor? Contractor What are specifications for the isolators and how many to be installed? Specifications (load rating, deflection, quantity) shall match chiller manufacturer recommendations for this model and meet all applicable codes, regulations, and industry standards. Crane will also fly new pumps up to roof to transport to mechanical room. How many pumps? 2 Are they end suction, double suction or inline type? The existing pumps are inline What is the flow rate in GPM, HD of pump, voltage, amperage and disconnect? New pumps should be approx. 500 gpm at 70 ft head, to be adjusted by Contractor appropriately if there is a significant change in pressure drop resulting from the installation of this new chiller. VFDs should be provided for each pump to allow for modulation to desired flow conditions. Where is the Mechanical Room Located, what is the access, how far from crane lift to the Mechanical Room? F10, 80FT Are these the Tiger Flow Pumps referenced below or two additional pumps? These pumps correspond to the Tiger Flow pumps referenced in the SOW Provide material and labor to pipe up new chiller as directed. Who will provide the direction and what direction will be offered? COR will provide direction, where to set up the crane and access to the current chiller. Material: New isolation valves, flex connections, piping, and fittings. Labor: To weld new piping, fittings, and flanges to install piping to chiller. What is the size of Valves, FLex, Piping, and fittings. Are fittings and piping Schd 40 black steel, A53 type? Piping and fittings shall match existing system diameter and material. Upgrade the existing 400amp feed to 500A. Where is the feed coming from, a panel or MCC? Main switch gear both emergency and normal power. Contractor responsible to field verify existing feed locations and any required routing. Provide manufacturer data to be able to price the new feed. See Photos listed below. Supply/install 1 600A disconnect fused to 500A. What is the specification for the disconnect, Nema Type and Material? Disconnect shall be NEMA 3R for outdoor installation with corrosion resistant construction. Install 120V power to butterfly valve actuators. Are any BAS/AUTOMATION Controls to be included with the project? Is this provided by VA or Contractor? Contractor If contractor who is the VA Control Contractor Name and Contact Info? Controls contractor contact information will be provided after award What size and where is the control valve located? Control valve location and size will be confirmed during the site visit. Provide labor and material to insulate new chiller piping and pump piping (New chiller piping to include metal jacketing and sealed for outdoor application). What type of insulation, Fiberglass, Foamglas, Poly, etc, and thickness to be used? Fiberglass insulation with aluminum jacketing is required for all exterior piping; thickness shall meet VA standard detail requirements and/or industry standards. Could you provide a set of drawings to delineate the installation requirements, or asbuilts of the installation or sufficient photos and data? N/A Can a site visit be arranged? If so, please provide dates and times available. A site visit can be arranged and highly recommended. Site Visits will occur on 03/30/2026 at 1pm Central Time Zone (CT). Meeting place will be the Boiler Plant, which is located at the loading dock of the VA Hospital. Please contact Clint Roberts at 629-401-7413 when you arrive or if you need assistance finding the location. If a Site Visit is allowed, will there be an extension allowed for the quotes deadline? Yes, the quote deadline is extended until 04/13/2026 and the question deadline is extended until 04/07/2026. END OF SOLICITATION AMENDMENT

Attachments

Files and links listed on SAM.gov. Files we hold a copy of download from here; the rest open SAM's download, which needs no account. Links open the sites the agency named.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
FNBQK6RYKE85
CAGE
61P79
Vendor location
Knoxville, TN
Contract
36C24926P0325, purchase order
Obligated
$697,697.16
Actions
2 between April 30, 2026 and November 13, 2026
Competition
Competed Under SAP, 5 offers received
Set-aside reported
Service Disabled Veteran Owned Small Business SET-ASIDE
Described as
Chiller & Pump Replacements
Match
award number 36C24926P0325 equals the contract number; same awarding office 36C249 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 12, 2026

    Presolicitation

    Chiller 7 & Pumps Replacement RFQ

    Due March 30, 2026 at 5:00 PM EDT. SAM.gov, notice 20e9141c00004843bf8391178bfda0e7

    2 revisions on SAM
    • March 12, 2026: publish, presolicitation
    • March 12, 2026: publish, solicitation
  2. March 12, 2026

    Solicitation, originally presolicitation

    Chiller 7 & Pumps Replacement RFQ

    Due March 30, 2026 at 5:00 PM EDT. SAM.gov, notice d4cace21464144dfa52bd494fc1f65bc

    3 revisions on SAM
    • March 20, 2026: publish, solicitation
    • March 12, 2026: publish, presolicitation
    • March 12, 2026: publish, solicitation
  3. March 20, 2026

    Solicitation

    Chiller 7 & Pumps Replacement RFQ

    Due April 13, 2026 at 5:00 PM EDT. SAM.gov, notice 7fe51040b6eb4913a847f31e9458d7cd

    3 revisions on SAM
    • May 7, 2026: publish, award notice
    • March 20, 2026: publish, solicitation
    • March 12, 2026: publish, solicitation
  4. May 7, 2026

    Award notice, originally solicitation

    Awarded to Accord Federal Services, LLC for $697,697. SAM.gov, notice 10ee6ea0ab6842e1b6fd48006274a439

    2 revisions on SAM
    • May 7, 2026: publish, award notice
    • March 20, 2026: publish, solicitation

Points of contact