Sources sought
Modernize Regenerative Thermal Oxidizer (RTO)
2031ZA27B00001
Bureau of Engraving and Printing, Office of the Chief Procurement Officer. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
November 25, 2026 at 4:00 PM EST
Closed yesterday. Posted November 18, 2026. Scheduled to archive December 10, 2026.
Get the next one like this from Bureau of Engraving and Printing by email, the day it is posted.Find my opportunities
This one closed yesterday
59 like it are open now in plumbing, heating, and air-conditioning contractors
- CON | Z1DA | REPLACE OR CHILLERS | 580-23-105 | SOLICITATION
Department of Veterans Affairs, 256-Network Contract Office 16
SolicitationSDVOSBNAICS 238220Houston, TX36C25626R0130Due in 6 daysDec 2 - CON | Z2DA | REPLACE CHILLER 1 B104 | 580-24-111 | SOLICITATION
Department of Veterans Affairs, 256-Network Contract Office 16
SolicitationSDVOSBNAICS 238220Houston, TX36C25626R0131Closes in 12 daysDec 8 - NTX VAMC Utility Tunnel Pump Room
Department of Veterans Affairs, 257-Network Contract Office 17
SolicitationSDVOSBNAICS 238220Dallas, TX36C25727Q0097Closes in 20 daysDec 16
All 59 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation has been published under this number yet. The sources sought of November 18, 2026 is the earliest notice of the purchase.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
SEEKING SOURCES ONLY - The Bureau of Engraving and Printing (BEP) Western Currency Facility (WCF) is located at 9000 Blue Mound Road, Fort Worth, TX, 76131. Construction began on the WCF in 1987 and was completed in 1989. The Modernized Regenerative Thermal Oxidizer (RTO) is an air pollution control device that is required by the NSR
(New Source Review) Air Permit issued by the TCEQ (Texas Commission on Environmental Quality) to treat Volatile Organic Compounds (VOC) emissions from Plate Printing presses (14), Offset presses (4), and Rotary Screen presses (4). The existing RTO was commissioned in 2010 to control VOC emissions from Plate Printing. In 2021, the Offset presses were added to the RTO system. The existing conveyance system, which currently includes ducting from each press to the roof, nine (9) roof fans, and a 48" main duct on the roof, has been in place since the facility was built in the early 90s. The system has been cobbled together as presses were added in Plate Printing, which originally only housed four (4) presses, without consideration for the wholistic efficiency of the system. It is a requirement of the Clean Air Act, EPA regulations, and the WCF air permits, that an air pollution control device associated with a "facility" (equipment or area that is emitting air pollutants as defined by EPA) must be maintained in good condition and operated properly while the attached "facilities" operate.
This design/build project shall replace the RTO and the associated exhaust ventilation system: a new RTO with a modern control panel including safe PLCs and lower working voltage, a properly designed exhaust ventilation system that self-optimizes with feedback from modern performance-monitoring systems, properly sized roof fans, accessibility to clean ducting where needed, and increased voe capture efficiency to better exhaust printing areas while allowing the RTO to operate using less supplemental fuel. The new system shall also incorporate features to decrease the amount of ink and oils that get conveyed into the exhaust ventilation system causing air flow issues and damaging ducting, fans, and other system components. Natural gas usage of the new RTO shall be metered and integrated into the BEP Supervisory Control And Data Acquisition (SCADA) system.
In 2025, the existing RTO underwent several upgrades including the installation of a new, modern control panel to address obsolete components and increasingly difficult troubleshooting. This project shall set the Western Currency Facility (WCF) up for success in providing operational redundancy alongside the newly overhauled RTO that is currently operating at the facility. The entire voe exhaust ventilation system shall feed into one of two RTOs (existing or new) with the capability to divert process flow from one RTO to the other in the event one RTO shuts down for any reason. This redundancy shall enable production to continue operating while the root cause of the issue is addressed.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
November 18, 2026
Sources sought
Due November 25, 2026 at 4:00 PM EST. SAM.gov, notice 622efd27a6cf48589063c08d3700b96b
1 revision on SAM
- November 18, 2026: publish, sources sought
Points of contact
- LaQulla WilliamsLaqulla.Williams@bep.gov2024862465
- Brandy Idemudiabrandy.idemudia@bep.gov