Solicitation, service-disabled veteran-owned small business set-aside
Canteen Freezer Repair
36C24725Q0080
Department of Veterans Affairs, 247-Network Contract Office 7. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
October 28, 2024 at 10:00 AM EDT
Closed 758 days ago. Posted November 4, 2024, first published October 21, 2024. Scheduled to archive November 5, 2024.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2024
59 like it are open now in plumbing, heating, and air-conditioning contractors
- REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS
Department of the Army, W6QK ACC Wva
Combined synopsis and solicitationSmall businessNAICS 238220New YorkW911PT27QA020Due todayNov 25 - Modernize Regenerative Thermal Oxidizer (RTO)
Bureau of Engraving and Printing, Office of the Chief Procurement Officer
Sources soughtNAICS 238220Texas2031ZA27B00001Due todayNov 25 - 13976 PUHO FIRE PROTECTION AT DORM
Departmental Offices, National Park Service Contracting Activity
Sources soughtNAICS 238220Location not published140PP027B0004Due tomorrowNov 26
All 59 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. Open SDVOSB opportunities
- Time to respond
- Bidders had 7 days from the day the solicitation was posted, October 21, 2024, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
STATEMENT OF WORK Order, receive and deliver to the jobsite the following equipment: One (1) Trenton 3.5-HP air-cooled condenser rated at 11,800 BTUH, Model TEZA035L8HT3DF. One (1) Trenton evaporator rated at 11,300 BTUH, Model TPLP211LES2DR8ESP. Lock and tag out the energy source to both the evaporator and condenser. Disconnect and reconnect the evaporator condensate drain line. Disconnect and reconnect the Type L copper refrigerant piping.
New copper piping and fittings will be utilized to tie the new equipment into the existing line sets. Disconnect and reconnect the high-voltage wiring to the condenser and evaporator. New fused disconnects will be installed for both the evaporator and condenser. Remove the existing evaporator and condenser. Move the new condenser onto the roof. Install the replacement evaporator. Pressurize, leak check, and evacuate the circuit per EPA guidelines.
Charge the system with virgin 448A refrigerant to OEM recommended sub-cooling guidelines. Insulate the affected ACR piping, and fittings and the condensate drain line. Start up and verify operation of the system. Clean up working area and return to prework conditions.
CHECK-IN REQUIREMENTS: Contractor and all Contractor’s Service Personnel shall check in and out with Engineering in plant prior to performing and upon completion of all required service. This information is required to contact mechanics in case of an emergency during regular hours.
SAFETY REQUIREMENTS: Contractor shall ensure all tools and equipment are always secured. Tools and equipment must be removed from open areas or stored in secured location during breaks, lunch, and/or at the end of each workday. All debris must be removed from the facility upon completion of service each day. All personnel are required to wear approved masks when entering or working in any of patient care areas in the facilities buildings.
They are to be non-surgical type masks, no cloth, or homemade masks (this is for staff and Contractors). This mask is to be always worn. Any personnel caught without wearing an approved mask will be escorted out of the facility. Masks are to be worn properly and should fully always cover the nose and mouth. Contractor shall ensure proper signage, barriers, and/or blockage of service area is provided where applicable. The Joseph Maxwell Cleland AVAMC is a smoke free campus.
Smoking is not permitted indoors or on campus (except at the Regional Office location), to include parking lots, at any time. All smoking shall be conducted at designated smoking areas.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- William Prenzlerwilliam.prenzler@va.gov