Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,699 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352

36C24526Q0352

Department of Veterans Affairs, 245-Network Contract Office 5. Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.

Response deadline

March 20, 2026 at 10:00 AM EDT

Closed 250 days ago. Posted March 9, 2026. Scheduled to archive April 19, 2026.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2026

58 like it are open now in commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance

All 58 open in commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 811310 (commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance), means no more than $12.5 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of March 9, 2026. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Summary: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice. Scope of work: Location of work: Louis A Johnson VA Medical Center 1 Medical Ctr Dr, Clarksburg, WV 26301 Base plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections. 1.0 Contract Structure Base Year: [Dates] Option Years 1-4: To be exercised annually. Emergency Coverage: 24/7/365 On-call availability. 2.0 Scope of Work The contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services. Monthly Operational Test Duration: Minimum 30 continuous minutes under facility load. Time-to-Transfer: Must reach operating voltage/frequency and transfer load within 10 seconds. ATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually. Supplemental Load Bank Testing (As Required) In accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run: Requirement: The contractor shall provide a portable load bank. Procedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating. Triennial (36-Month) 4-Hour Run Once every 36 months, the contractor shall conduct a continuous 4-hour load test: First 3 Hours: Minimum 30% of nameplate kW. Final Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient). 3.0 Emergency Response & Repair Response Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff. Availability: This requirement applies 24 hours a day, 7 days a week, including holidays. Reporting: Any emergency repair must result in a "Return to Service" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness. 4.0 TJC & OIG Documentation Standards All reports must be "Audit-Ready" and submitted to the Facilities Management Service (FMS) within 72 hours. Speci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures. Battery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit. Certi cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria. 5.0 Contractor Quali cations & Safety Certi cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets. Safety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter. Record Management. . Documentation Requirements: Date of test Start and end time. Total run duration. Generator identi cation number/location. Load percentage or kW output. Voltage and frequency readings. Oil pressure and coolant temperature readings. Fuel level. Battery condition. Following NFPA 110. 7.0 Record Retention. Generator test records shall be maintained for a minimum of three (3) years. Records may be maintained electronically or in hard copy available to the facility when requested. 8.0 Generator Description. GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) Please respond to this RFI/Sources Sought 36C24526Q0352 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Responses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. Respond: 36C24526Q0352 Sources Sought Notice | Company Name This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 9, 2026

    Sources sought

    Due March 20, 2026 at 10:00 AM EDT. SAM.gov, notice 3a839ba680884c8a8ae6a71a3905cde0

    1 revision on SAM
    • March 9, 2026: publish, sources sought

Points of contact