{"canonical":"https://sealedbidder.com/opportunities/36c24526q0352","key":"36C24526Q0352","url":"https://sealedbidder.com/opportunities/36c24526q0352","title":"J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352","solicitation_number":"36C24526Q0352","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-20T14:00:00Z","first_posted":"2026-03-09","last_posted":"2026-03-09","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"811310","psc":"J049","set_aside":null,"place_state":"WV","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"54033","place_county_name":"Harrison County","place_city":"5415628","place_city_name":"Clarksburg","winner":null,"award_amount":null,"publications":[{"notice_id":"3a839ba680884c8a8ae6a71a3905cde0","title":"J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352","solicitation_number":"36C24526Q0352","notice_type":"r","base_type":"r","posted":"2026-03-09","posted_at":"2026-03-09T15:57:51.849Z","due_at":"2026-03-20T14:00:00Z","due_date":"2026-03-20","cancelled":false,"archived":true,"archive_date":"2026-04-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3a839ba680884c8a8ae6a71a3905cde0/view","enriched":true,"history":[{"index":3,"title":"J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T15:57:51.849Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3a839ba680884c8a8ae6a71a3905cde0","solicitation_number":"36C24526Q0352"}]}],"latest_notice_id":"3a839ba680884c8a8ae6a71a3905cde0","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-09","posted_at":"2026-03-09T15:57:51.849Z","created_at":"2026-03-09T15:57:49.496Z","modified_at":"2026-04-20T03:55:46.196Z","response_deadline":{"raw":"2026-03-20T10:00:00-04:00","utc":"2026-03-20T14:00:00Z","date":"2026-03-20","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3a839ba680884c8a8ae6a71a3905cde0/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352","agency":{"office":{"code":"36C245","name":"245-NETWORK CONTRACT OFFICE 5 (36C245)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"organization_id":"100173468","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-19","archive_type":"auto_custom"},"history":[{"index":3,"title":"J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-09T15:57:51.849Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"3a839ba680884c8a8ae6a71a3905cde0","solicitation_number":"36C24526Q0352"}],"contacts":[{"name":"Bill Pratt","role":"primary","email":"Billie.Pratt@va.gov","phone":"410-642-2411","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"3a839ba680884c8a8ae6a71a3905cde0","lineage_id":"3a839ba680884c8a8ae6a71a3905cde0","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T10:38:22.820832243Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6f4add51e07b06b15ac13768da9056625d73c550b9464d011953fe2a4563a8b2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T10:38:22.820832243Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Summary: \n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5,\nis issuing this request for sources sought notice in order to identify vendors that are interested in and\ncapable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice. \n\nScope of work: \n \nLocation of work: \nLouis A Johnson VA Medical Center\n1 Medical Ctr Dr, Clarksburg, WV 26301\nBase plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections.\n1.0 Contract Structure\nBase Year: [Dates]\nOption Years 1-4: To be exercised annually.\nEmergency Coverage: 24/7/365 On-call availability.\n2.0 Scope of Work\nThe contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services.\nMonthly Operational Test\nDuration: Minimum 30 continuous minutes under facility load.\nTime-to-Transfer: Must reach operating voltage/frequency and transfer load within\n10 seconds.\nATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually.\nSupplemental Load Bank Testing (As Required)\nIn accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run:\nRequirement: The contractor shall provide a portable load bank.\nProcedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating.\nTriennial (36-Month) 4-Hour Run\nOnce every 36 months, the contractor shall conduct a continuous 4-hour load test:\nFirst 3 Hours: Minimum 30% of nameplate kW.\nFinal Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient).\n3.0 Emergency Response & Repair\n\n\nResponse Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff.\nAvailability: This requirement applies 24 hours a day, 7 days a week, including holidays.\nReporting: Any emergency repair must result in a \"Return to Service\" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness.\n4.0 TJC & OIG Documentation Standards\nAll reports must be \"Audit-Ready\" and submitted to the Facilities Management Service\n(FMS) within 72 hours.\nSpeci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures.\nBattery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit.\nCerti cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria.\n5.0 Contractor Quali cations & Safety\nCerti cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets.\nSafety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter.\nRecord Management.\n. Documentation Requirements:\nDate of test\nStart and end time.\nTotal run duration.\nGenerator identi cation number/location.\nLoad percentage or kW output.\nVoltage and frequency readings.\n\n\nOil pressure and coolant temperature readings.\nFuel level.\nBattery condition.\nFollowing NFPA 110.\n\n7.0 Record Retention.\nGenerator test records shall be maintained for a minimum of three (3) years.\nRecords may be maintained electronically or in hard copy available to the facility when requested.\n8.0 Generator Description.\n\n\nGENSET #1\nGENSET #2\nGENSET #3\nManufacturer/Make/Year:\nCaterpillar\nCaterpillar\nKato\nModel No:\nSR-4\nC32\n500SS9D\nSerial/Order No:\n6NA01031\nG1G00044\n7319\nLoad Rating: (Emergency/Standby/Prime)\n1000 kva\n1250 kva\n625KVA\nPower Factor:\n.8\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\n60 hertz\nLoad in Amperage:\n1000 amps\n1000 amps\n87\nOutput Voltage:\n480\n480 volts\n4160 volts\nPhase:\n3-phase\n3-phase\n3-phase\nBuilding:\nBld 17\nBld 17\nBld 17\nLocation (Area/Room):\nGenerator room\nGenerator Rm\nGenerator Rm\n\n\nGENSET #4\nGENSET #5 (portable)\nManufacturer/Make/Year:\nKohler\nBaldor\nModel No:\n100RE0ZJF\nTS225-3J\n\nSerial/Order No:\n3346GMJL0001\nP1205240012\n\nLoad Rating: (Emergency/Standby/Prime)\n128 kva\n225 kva\nPower Factor:\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\nLoad in Amperage:\n153 amps\n625 amps\n\nOutput Voltage:\n480\n480 volts\nPhase:\n3-phase\n3-phase\nBuilding:\nParking Garage\nGrounds\nLocation (Area/Room):\nParking Garage\nGrounds (portable)\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nPlease respond to this RFI/Sources Sought 36C24526Q0352 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned,\nWoman-Owned, Disadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing\nthese types of services for the Veterans Health Administration or other\nsimilar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of\nVA (include applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide\nthese services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet\nthe performance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\n\nResponses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov.\nRespond: 36C24526Q0352   Sources Sought Notice | Company Name\n\nThis request for information/sources sought notice is for planning purposes ONLY and\ndoes not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market\nresearch will assist in the development of (1) the requirement, and (2) the acquisition\nstrategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.","text":"Summary:\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5,\nis issuing this request for sources sought notice in order to identify vendors that are interested in and\ncapable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice.\n\nScope of work:\n\nLocation of work:\nLouis A Johnson VA Medical Center\n1 Medical Ctr Dr, Clarksburg, WV 26301\nBase plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections.\n1.0 Contract Structure\nBase Year: [Dates]\nOption Years 1-4: To be exercised annually.\nEmergency Coverage: 24/7/365 On-call availability.\n2.0 Scope of Work\nThe contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services.\nMonthly Operational Test\nDuration: Minimum 30 continuous minutes under facility load.\nTime-to-Transfer: Must reach operating voltage/frequency and transfer load within\n10 seconds.\nATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually.\nSupplemental Load Bank Testing (As Required)\nIn accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run:\nRequirement: The contractor shall provide a portable load bank.\nProcedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating.\nTriennial (36-Month) 4-Hour Run\nOnce every 36 months, the contractor shall conduct a continuous 4-hour load test:\nFirst 3 Hours: Minimum 30% of nameplate kW.\nFinal Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient).\n3.0 Emergency Response & Repair\n\nResponse Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff.\nAvailability: This requirement applies 24 hours a day, 7 days a week, including holidays.\nReporting: Any emergency repair must result in a \"Return to Service\" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness.\n4.0 TJC & OIG Documentation Standards\nAll reports must be \"Audit-Ready\" and submitted to the Facilities Management Service\n(FMS) within 72 hours.\nSpeci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures.\nBattery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit.\nCerti cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria.\n5.0 Contractor Quali cations & Safety\nCerti cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets.\nSafety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter.\nRecord Management.\n. Documentation Requirements:\nDate of test\nStart and end time.\nTotal run duration.\nGenerator identi cation number/location.\nLoad percentage or kW output.\nVoltage and frequency readings.\n\nOil pressure and coolant temperature readings.\nFuel level.\nBattery condition.\nFollowing NFPA 110.\n\n7.0 Record Retention.\nGenerator test records shall be maintained for a minimum of three (3) years.\nRecords may be maintained electronically or in hard copy available to the facility when requested.\n8.0 Generator Description.\n\nGENSET #1\nGENSET #2\nGENSET #3\nManufacturer/Make/Year:\nCaterpillar\nCaterpillar\nKato\nModel No:\nSR-4\nC32\n500SS9D\nSerial/Order No:\n6NA01031\nG1G00044\n7319\nLoad Rating: (Emergency/Standby/Prime)\n1000 kva\n1250 kva\n625KVA\nPower Factor:\n.8\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\n60 hertz\nLoad in Amperage:\n1000 amps\n1000 amps\n87\nOutput Voltage:\n480\n480 volts\n4160 volts\nPhase:\n3-phase\n3-phase\n3-phase\nBuilding:\nBld 17\nBld 17\nBld 17\nLocation (Area/Room):\nGenerator room\nGenerator Rm\nGenerator Rm\n\nGENSET #4\nGENSET #5 (portable)\nManufacturer/Make/Year:\nKohler\nBaldor\nModel No:\n100RE0ZJF\nTS225-3J\n\nSerial/Order No:\n3346GMJL0001\nP1205240012\n\nLoad Rating: (Emergency/Standby/Prime)\n128 kva\n225 kva\nPower Factor:\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\nLoad in Amperage:\n153 amps\n625 amps\n\nOutput Voltage:\n480\n480 volts\nPhase:\n3-phase\n3-phase\nBuilding:\nParking Garage\nGrounds\nLocation (Area/Room):\nParking Garage\nGrounds (portable)\n\nPlease respond to this RFI/Sources Sought 36C24526Q0352 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned,\nWoman-Owned, Disadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing\nthese types of services for the Veterans Health Administration or other\nsimilar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of\nVA (include applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide\nthese services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet\nthe performance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\n\nResponses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov.\nRespond: 36C24526Q0352 Sources Sought Notice | Company Name\n\nThis request for information/sources sought notice is for planning purposes ONLY and\ndoes not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market\nresearch will assist in the development of (1) the requirement, and (2) the acquisition\nstrategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24526Q0352","place_of_performance":{"zip":"26301","city":{"code":"15628","name":"Clarksburg"},"state":{"code":"WV","name":"West Virginia"},"street":"Department of Veterans Affairs Louis A. Johnson VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"1 Medical Center Drive"},"product_service_code":"J049"}],"due_at":"2026-03-20T14:00:00Z","due_date":"2026-03-20","closes_at":"2026-03-20T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-11T11:27:07.726584Z","principal_notice_id":"3a839ba680884c8a8ae6a71a3905cde0","description":{"text":"Summary:\n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5,\nis issuing this request for sources sought notice in order to identify vendors that are interested in and\ncapable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice.\n\nScope of work:\n\nLocation of work:\nLouis A Johnson VA Medical Center\n1 Medical Ctr Dr, Clarksburg, WV 26301\nBase plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections.\n1.0 Contract Structure\nBase Year: [Dates]\nOption Years 1-4: To be exercised annually.\nEmergency Coverage: 24/7/365 On-call availability.\n2.0 Scope of Work\nThe contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services.\nMonthly Operational Test\nDuration: Minimum 30 continuous minutes under facility load.\nTime-to-Transfer: Must reach operating voltage/frequency and transfer load within\n10 seconds.\nATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually.\nSupplemental Load Bank Testing (As Required)\nIn accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run:\nRequirement: The contractor shall provide a portable load bank.\nProcedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating.\nTriennial (36-Month) 4-Hour Run\nOnce every 36 months, the contractor shall conduct a continuous 4-hour load test:\nFirst 3 Hours: Minimum 30% of nameplate kW.\nFinal Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient).\n3.0 Emergency Response & Repair\n\nResponse Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff.\nAvailability: This requirement applies 24 hours a day, 7 days a week, including holidays.\nReporting: Any emergency repair must result in a \"Return to Service\" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness.\n4.0 TJC & OIG Documentation Standards\nAll reports must be \"Audit-Ready\" and submitted to the Facilities Management Service\n(FMS) within 72 hours.\nSpeci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures.\nBattery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit.\nCerti cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria.\n5.0 Contractor Quali cations & Safety\nCerti cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets.\nSafety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter.\nRecord Management.\n. Documentation Requirements:\nDate of test\nStart and end time.\nTotal run duration.\nGenerator identi cation number/location.\nLoad percentage or kW output.\nVoltage and frequency readings.\n\nOil pressure and coolant temperature readings.\nFuel level.\nBattery condition.\nFollowing NFPA 110.\n\n7.0 Record Retention.\nGenerator test records shall be maintained for a minimum of three (3) years.\nRecords may be maintained electronically or in hard copy available to the facility when requested.\n8.0 Generator Description.\n\nGENSET #1\nGENSET #2\nGENSET #3\nManufacturer/Make/Year:\nCaterpillar\nCaterpillar\nKato\nModel No:\nSR-4\nC32\n500SS9D\nSerial/Order No:\n6NA01031\nG1G00044\n7319\nLoad Rating: (Emergency/Standby/Prime)\n1000 kva\n1250 kva\n625KVA\nPower Factor:\n.8\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\n60 hertz\nLoad in Amperage:\n1000 amps\n1000 amps\n87\nOutput Voltage:\n480\n480 volts\n4160 volts\nPhase:\n3-phase\n3-phase\n3-phase\nBuilding:\nBld 17\nBld 17\nBld 17\nLocation (Area/Room):\nGenerator room\nGenerator Rm\nGenerator Rm\n\nGENSET #4\nGENSET #5 (portable)\nManufacturer/Make/Year:\nKohler\nBaldor\nModel No:\n100RE0ZJF\nTS225-3J\n\nSerial/Order No:\n3346GMJL0001\nP1205240012\n\nLoad Rating: (Emergency/Standby/Prime)\n128 kva\n225 kva\nPower Factor:\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\nLoad in Amperage:\n153 amps\n625 amps\n\nOutput Voltage:\n480\n480 volts\nPhase:\n3-phase\n3-phase\nBuilding:\nParking Garage\nGrounds\nLocation (Area/Room):\nParking Garage\nGrounds (portable)\n\nPlease respond to this RFI/Sources Sought 36C24526Q0352 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned,\nWoman-Owned, Disadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing\nthese types of services for the Veterans Health Administration or other\nsimilar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of\nVA (include applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide\nthese services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet\nthe performance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\n\nResponses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov.\nRespond: 36C24526Q0352 Sources Sought Notice | Company Name\n\nThis request for information/sources sought notice is for planning purposes ONLY and\ndoes not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market\nresearch will assist in the development of (1) the requirement, and (2) the acquisition\nstrategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.","html":"Summary: \n\nDepartment of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5,\nis issuing this request for sources sought notice in order to identify vendors that are interested in and\ncapable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice. \n\nScope of work: \n \nLocation of work: \nLouis A Johnson VA Medical Center\n1 Medical Ctr Dr, Clarksburg, WV 26301\nBase plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections.\n1.0 Contract Structure\nBase Year: [Dates]\nOption Years 1-4: To be exercised annually.\nEmergency Coverage: 24/7/365 On-call availability.\n2.0 Scope of Work\nThe contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services.\nMonthly Operational Test\nDuration: Minimum 30 continuous minutes under facility load.\nTime-to-Transfer: Must reach operating voltage/frequency and transfer load within\n10 seconds.\nATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually.\nSupplemental Load Bank Testing (As Required)\nIn accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run:\nRequirement: The contractor shall provide a portable load bank.\nProcedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating.\nTriennial (36-Month) 4-Hour Run\nOnce every 36 months, the contractor shall conduct a continuous 4-hour load test:\nFirst 3 Hours: Minimum 30% of nameplate kW.\nFinal Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient).\n3.0 Emergency Response & Repair\n\n\nResponse Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff.\nAvailability: This requirement applies 24 hours a day, 7 days a week, including holidays.\nReporting: Any emergency repair must result in a \"Return to Service\" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness.\n4.0 TJC & OIG Documentation Standards\nAll reports must be \"Audit-Ready\" and submitted to the Facilities Management Service\n(FMS) within 72 hours.\nSpeci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures.\nBattery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit.\nCerti cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria.\n5.0 Contractor Quali cations & Safety\nCerti cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets.\nSafety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter.\nRecord Management.\n. Documentation Requirements:\nDate of test\nStart and end time.\nTotal run duration.\nGenerator identi cation number/location.\nLoad percentage or kW output.\nVoltage and frequency readings.\n\n\nOil pressure and coolant temperature readings.\nFuel level.\nBattery condition.\nFollowing NFPA 110.\n\n7.0 Record Retention.\nGenerator test records shall be maintained for a minimum of three (3) years.\nRecords may be maintained electronically or in hard copy available to the facility when requested.\n8.0 Generator Description.\n\n\nGENSET #1\nGENSET #2\nGENSET #3\nManufacturer/Make/Year:\nCaterpillar\nCaterpillar\nKato\nModel No:\nSR-4\nC32\n500SS9D\nSerial/Order No:\n6NA01031\nG1G00044\n7319\nLoad Rating: (Emergency/Standby/Prime)\n1000 kva\n1250 kva\n625KVA\nPower Factor:\n.8\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\n60 hertz\nLoad in Amperage:\n1000 amps\n1000 amps\n87\nOutput Voltage:\n480\n480 volts\n4160 volts\nPhase:\n3-phase\n3-phase\n3-phase\nBuilding:\nBld 17\nBld 17\nBld 17\nLocation (Area/Room):\nGenerator room\nGenerator Rm\nGenerator Rm\n\n\nGENSET #4\nGENSET #5 (portable)\nManufacturer/Make/Year:\nKohler\nBaldor\nModel No:\n100RE0ZJF\nTS225-3J\n\nSerial/Order No:\n3346GMJL0001\nP1205240012\n\nLoad Rating: (Emergency/Standby/Prime)\n128 kva\n225 kva\nPower Factor:\n.8\n.8\nFrequency:\n60 Hertz\n60 Hertz\nLoad in Amperage:\n153 amps\n625 amps\n\nOutput Voltage:\n480\n480 volts\nPhase:\n3-phase\n3-phase\nBuilding:\nParking Garage\nGrounds\nLocation (Area/Room):\nParking Garage\nGrounds (portable)\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nPlease respond to this RFI/Sources Sought 36C24526Q0352 with your:\n1. Business name (including Unique Entity ID (SAM.gov)\n2. Business type, socio-economic status (e.g., Veteran-Owned,\nWoman-Owned, Disadvantaged Small Business, 8(a), etc.), and\n3. Person of contact (including telephone number & email address).\n4. Capability statement and summary of previous experience providing\nthese types of services for the Veterans Health Administration or other\nsimilar facilities.\n5. Available contract vehicles (GSA FSS, etc.) for use by Department of\nVA (include applicable NAICS)\n6. Brief Summary of categories of services that your company can/cannot provide.\n7. Certification(s) / Licenses for meeting the local requirements to provide\nthese services at the DC VAMC (if applicable)\n8. Confirmation that your organization has the capability & expertise to meet\nthe performance requirements while complying with applicable limitations in\nsubcontracting by responding to the questions below with your response:\na. Do you intend to self-perform this effort?\nb. If you are located outside the immediate area, how will you self-perform?\nc. Or do you intend to subcontract work under this contract?\nd. If you intend to subcontract work under this contract, how will you ensure\ncompliance with the limitations on subcontracting?\nResponse Instructions:\n\nResponses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the\ninformation requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov.\nRespond: 36C24526Q0352   Sources Sought Notice | Company Name\n\nThis request for information/sources sought notice is for planning purposes ONLY and\ndoes not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market\nresearch will assist in the development of (1) the requirement, and (2) the acquisition\nstrategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.","origin":"detail"},"contacts":[{"name":"Bill Pratt","role":"primary","email":"Billie.Pratt@va.gov","phone":"410-642-2411","title":"Contracting Officer"}],"place_of_performance":{"zip":"26301","city":{"code":"15628","name":"Clarksburg"},"state":{"code":"WV","name":"West Virginia"},"street":"Department of Veterans Affairs Louis A. Johnson VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"1 Medical Center Drive"},"office_address":{"zip":"21090","city":"LINTHICUM","state":"MD","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"8da5fe919b1f4d0e87ce8d041f067928","name":"36C24526Q0352.docx","kind":"file","mime_type":".docx","size_bytes":30975,"posted_at":"2026-03-09T15:57:51.849Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8da5fe919b1f4d0e87ce8d041f067928/download","mirrored":false}],"awards":[],"related":[{"key":"36C24526R0101","latest_notice_id":"e84156527a944ee3bd5001d28af5d713","title":"C1DA-- Renovate Specialty Clinics on 2nd","solicitation_number":"36C24526R0101","notice_type":"r","first_type":"r","first_posted":"2026-09-24","last_posted":"2026-11-18","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541310","psc":"C1DA","set_aside":"SDVOSBC","state":"WV","county":"54081","county_name":"Raleigh County","city":"5405332","city_name":"Beckley","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0070","latest_notice_id":"b0b1581a6a1441b9a46d407375bc44d0","title":"6550--FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |","solicitation_number":"36C24527Q0070","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"325413","psc":"6550","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C24527Q0061","latest_notice_id":"0db5662de5914b458655bed9898980cf","title":"J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT","solicitation_number":"36C24527Q0061","notice_type":"o","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":3,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"561210","psc":"J065","set_aside":"SBA","state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24527Q0081","latest_notice_id":"77e2cd670c3040a6ad2a1fc44daa2bc5","title":"DJ10--Alertus Enhanced Notification Licensing & Premier Support","solicitation_number":"36C24527Q0081","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"541519","psc":"DJ10","set_aside":null,"state":"WV","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOFTWARE LICENSING AND SUPPORT MARTINSBURG VA MEDICAL CENTER","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24527Q0073","latest_notice_id":"6ce8b040a9be44d0972b338bc7b6cf88","title":"Arc Flash Hazard Analysis Services","solicitation_number":"36C24527Q0073","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C245","office_name":"245-NETWORK CONTRACT OFFICE 5 (36C245)","naics":"334515","psc":"6625","set_aside":null,"state":"WV","county":"54033","county_name":"Harrison County","city":"5415628","city_name":"Clarksburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"36C25627Q0131","latest_notice_id":"c34b2da547fb4d8fb1ceaf2fb177c660","title":"J012--Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service","solicitation_number":"36C25627Q0131","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"811310","psc":"J012","set_aside":null,"state":"AR","county":"05119","county_name":"Pulaski County","city":"0550450","city_name":"North Little Rock","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"70Z02727RFQ000010","latest_notice_id":"d442a8374a9f40518aefb30b4adc715a","title":"USCG IPD Cape May Crane Repairs","solicitation_number":"70Z02727RFQ000010","notice_type":"o","first_type":"o","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"811310","psc":"J039","set_aside":"SBA","state":"NJ","county":"34009","county_name":"Cape May County","city":"3410270","city_name":"Cape May","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":58,"indexable":false}