Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,681 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Sources sought

642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)

36C24425Q0406

Department of Veterans Affairs, 244-Network Contract Office 4. Surgical and Medical Instrument Manufacturing.

Response deadline

March 4, 2025 at 12:00 PM EST

Closed 632 days ago. Posted February 27, 2025. Scheduled to archive March 19, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

14 like it are open now in surgical and medical instrument manufacturing

All 14 open in surgical and medical instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of February 27, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals: however, reserves the right to do so at a later date. The Philadelphia VA Medical Center at 3600 Woodland Avenue, Philadelphia, PA 19104, is currently seeking potential sources for a Brand Name or Equal comprehensive optometry biometer. The brand name for reference is the Carl Zeiss IOL Master 700 comprehensive system. Please review the salient characteristics below: SALIENT CHARACTERISTICS: ALL ITEMS MUST BE COMPATIBLE WITH THE CARL ZEISS ECOSYSTEM, SPECIFICALLY THE ZEISS FORUM. Measurement technology and accuracy: Contactless Swept Source OCT Biometry Must be capable of providing axial length, keratometry, and central anterior chamber depth measurements. Corneal topography Must be capable of providing posterior and anterior corneal topography to enhance IOL calculations. IOL calculation and surgical planning capabilities: Must include integrated Barret Suite. Must include markless Tori IOL alignment. Must be capable of reducing the risk of refractive surprise. Workflow efficiency and data management: Automated biometry measurement: Must be capable of completing full biometry in under 1 minute for both eyes. Full length OCT image capture Must be capable of providing a comprehensive cornea-to-retina scan to detect potential measurement errors Automated data transfer: Must be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. Must be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. DICOM compatibility: Must be DICOM-compliant to interface with electronic medical record systems. Physical and Operational Requirements Must have a compact and ergonomical design. Must include patient positioning features. Adjustable chin rest. Head support for stable measurements. Must be compatible with standard U.S. electrical outlets. Must be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. February 27, 2025

    Sources sought

    Due March 4, 2025 at 12:00 PM EST. SAM.gov, notice 1fb6be45f2d04fdfa527c5a865e0d60a

    1 revision on SAM
    • February 27, 2025: publish, sources sought

Points of contact