{"canonical":"https://sealedbidder.com/opportunities/36c24425q0406","key":"36C24425Q0406","url":"https://sealedbidder.com/opportunities/36c24425q0406","title":"6515--642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)","solicitation_number":"36C24425Q0406","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-04T17:00:00Z","first_posted":"2025-02-27","last_posted":"2025-02-27","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"place_state":"PA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"42101","place_county_name":"Philadelphia County","place_city":"4260000","place_city_name":"Philadelphia","winner":null,"award_amount":null,"publications":[{"notice_id":"1fb6be45f2d04fdfa527c5a865e0d60a","title":"6515--642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)","solicitation_number":"36C24425Q0406","notice_type":"r","base_type":"r","posted":"2025-02-27","posted_at":"2025-02-27T16:56:28.937Z","due_at":"2025-03-04T17:00:00Z","due_date":"2025-03-04","cancelled":false,"archived":true,"archive_date":"2025-03-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1fb6be45f2d04fdfa527c5a865e0d60a/view","enriched":true,"history":[{"index":3,"title":"6515--642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T16:56:28.937Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1fb6be45f2d04fdfa527c5a865e0d60a","solicitation_number":"36C24425Q0406"}]}],"latest_notice_id":"1fb6be45f2d04fdfa527c5a865e0d60a","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-27","posted_at":"2025-02-27T16:56:28.937Z","created_at":"2025-02-27T16:56:26.738Z","modified_at":"2025-03-20T03:55:45.738Z","response_deadline":{"raw":"2025-03-04T12:00:00-05:00","utc":"2025-03-04T17:00:00Z","date":"2025-03-04","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1fb6be45f2d04fdfa527c5a865e0d60a/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)","agency":{"office":{"code":"36C244","name":"244-NETWORK CONTRACT OFFICE 4 (36C244)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"organization_id":"100163848","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-19","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--642-25-2-316-0062 | BNOE to ZEISS IOL MASTER 700 | NCO 4 Commodities | 2 (VA-25-00042739)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T16:56:28.937Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"1fb6be45f2d04fdfa527c5a865e0d60a","solicitation_number":"36C24425Q0406"}],"contacts":[{"name":"Joanne Skaff","role":"primary","email":"joanne.skaff@va.gov","phone":"570-899-6581","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"1fb6be45f2d04fdfa527c5a865e0d60a","lineage_id":"1fb6be45f2d04fdfa527c5a865e0d60a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T11:15:40.958503343Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"9ae5d246b2c31a03545aa3f34a033ae83144abb40a456b82f5f8122f9789dd04","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T11:15:40.958503343Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals: however, reserves the right to do so at a later date. The Philadelphia VA Medical Center at 3600 Woodland Avenue, Philadelphia, PA 19104, is currently seeking potential sources for a Brand Name or Equal comprehensive optometry biometer. The brand name for reference is the Carl Zeiss IOL Master 700 comprehensive system. Please review the salient characteristics below:\nSALIENT CHARACTERISTICS:\nALL ITEMS MUST BE COMPATIBLE WITH THE CARL ZEISS ECOSYSTEM, SPECIFICALLY THE ZEISS FORUM. \nMeasurement technology and accuracy: \nContactless Swept Source OCT Biometry\nMust be capable of providing axial length, keratometry, and central anterior chamber depth measurements.\nCorneal topography\nMust be capable of providing posterior and anterior corneal topography to enhance IOL calculations. \n\nIOL calculation and surgical planning capabilities: \nMust include integrated Barret Suite.\nMust include markless Tori IOL alignment.\nMust be capable of reducing the risk of refractive surprise. \n\nWorkflow efficiency and data management: \nAutomated biometry measurement: \nMust be capable of completing full biometry in under 1 minute for both eyes.\nFull length OCT image capture \nMust be capable of providing a comprehensive cornea-to-retina scan to detect potential measurement errors\nAutomated data transfer: \nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. \nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. \nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems. \n\nPhysical and Operational Requirements \nMust have a compact and ergonomical design. \nMust include patient positioning features. \nAdjustable chin rest.\nHead support for stable measurements. \nMust be compatible with standard U.S. electrical outlets. \nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.","text":"The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals: however, reserves the right to do so at a later date. The Philadelphia VA Medical Center at 3600 Woodland Avenue, Philadelphia, PA 19104, is currently seeking potential sources for a Brand Name or Equal comprehensive optometry biometer. The brand name for reference is the Carl Zeiss IOL Master 700 comprehensive system. Please review the salient characteristics below:\nSALIENT CHARACTERISTICS:\nALL ITEMS MUST BE COMPATIBLE WITH THE CARL ZEISS ECOSYSTEM, SPECIFICALLY THE ZEISS FORUM.\nMeasurement technology and accuracy:\nContactless Swept Source OCT Biometry\nMust be capable of providing axial length, keratometry, and central anterior chamber depth measurements.\nCorneal topography\nMust be capable of providing posterior and anterior corneal topography to enhance IOL calculations.\n\nIOL calculation and surgical planning capabilities:\nMust include integrated Barret Suite.\nMust include markless Tori IOL alignment.\nMust be capable of reducing the risk of refractive surprise.\n\nWorkflow efficiency and data management:\nAutomated biometry measurement:\nMust be capable of completing full biometry in under 1 minute for both eyes.\nFull length OCT image capture\nMust be capable of providing a comprehensive cornea-to-retina scan to detect potential measurement errors\nAutomated data transfer:\nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM.\nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa.\nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems.\n\nPhysical and Operational Requirements\nMust have a compact and ergonomical design.\nMust include patient positioning features.\nAdjustable chin rest.\nHead support for stable measurements.\nMust be compatible with standard U.S. electrical outlets.\nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24425Q0406","place_of_performance":{"zip":"19104","city":{"name":"Philadelphia"},"state":{"name":"PA"},"street":"Department of Veterans Affairs Network Contracting Office 4","country":{"code":"USA","name":"UNITED STATES"},"street2":"Corporal Michael J. Crescenz VA Medical Center 3900 Woodland Avenue"},"product_service_code":"6515"}],"due_at":"2025-03-04T17:00:00Z","due_date":"2025-03-04","closes_at":"2025-03-04T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-21T11:35:43.260079Z","principal_notice_id":"1fb6be45f2d04fdfa527c5a865e0d60a","description":{"text":"The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals: however, reserves the right to do so at a later date. The Philadelphia VA Medical Center at 3600 Woodland Avenue, Philadelphia, PA 19104, is currently seeking potential sources for a Brand Name or Equal comprehensive optometry biometer. The brand name for reference is the Carl Zeiss IOL Master 700 comprehensive system. Please review the salient characteristics below:\nSALIENT CHARACTERISTICS:\nALL ITEMS MUST BE COMPATIBLE WITH THE CARL ZEISS ECOSYSTEM, SPECIFICALLY THE ZEISS FORUM.\nMeasurement technology and accuracy:\nContactless Swept Source OCT Biometry\nMust be capable of providing axial length, keratometry, and central anterior chamber depth measurements.\nCorneal topography\nMust be capable of providing posterior and anterior corneal topography to enhance IOL calculations.\n\nIOL calculation and surgical planning capabilities:\nMust include integrated Barret Suite.\nMust include markless Tori IOL alignment.\nMust be capable of reducing the risk of refractive surprise.\n\nWorkflow efficiency and data management:\nAutomated biometry measurement:\nMust be capable of completing full biometry in under 1 minute for both eyes.\nFull length OCT image capture\nMust be capable of providing a comprehensive cornea-to-retina scan to detect potential measurement errors\nAutomated data transfer:\nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM.\nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa.\nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems.\n\nPhysical and Operational Requirements\nMust have a compact and ergonomical design.\nMust include patient positioning features.\nAdjustable chin rest.\nHead support for stable measurements.\nMust be compatible with standard U.S. electrical outlets.\nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.","html":"The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals: however, reserves the right to do so at a later date. The Philadelphia VA Medical Center at 3600 Woodland Avenue, Philadelphia, PA 19104, is currently seeking potential sources for a Brand Name or Equal comprehensive optometry biometer. The brand name for reference is the Carl Zeiss IOL Master 700 comprehensive system. Please review the salient characteristics below:\nSALIENT CHARACTERISTICS:\nALL ITEMS MUST BE COMPATIBLE WITH THE CARL ZEISS ECOSYSTEM, SPECIFICALLY THE ZEISS FORUM. \nMeasurement technology and accuracy: \nContactless Swept Source OCT Biometry\nMust be capable of providing axial length, keratometry, and central anterior chamber depth measurements.\nCorneal topography\nMust be capable of providing posterior and anterior corneal topography to enhance IOL calculations. \n\nIOL calculation and surgical planning capabilities: \nMust include integrated Barret Suite.\nMust include markless Tori IOL alignment.\nMust be capable of reducing the risk of refractive surprise. \n\nWorkflow efficiency and data management: \nAutomated biometry measurement: \nMust be capable of completing full biometry in under 1 minute for both eyes.\nFull length OCT image capture \nMust be capable of providing a comprehensive cornea-to-retina scan to detect potential measurement errors\nAutomated data transfer: \nMust be capable of seamlessly integrating with ophthalmic data management systems already in place to eliminate manual data entry errors. The data management system in place is the ZEISS FORUM. \nMust be capable of transferring data via ZEISS FORUM into the biometry unit and vice versa. \nDICOM compatibility:\nMust be DICOM-compliant to interface with electronic medical record systems. \n\nPhysical and Operational Requirements \nMust have a compact and ergonomical design. \nMust include patient positioning features. \nAdjustable chin rest.\nHead support for stable measurements. \nMust be compatible with standard U.S. electrical outlets. \nMust be FDA-approved for use in ophthalmic biometry and comply with ISO standards for medical devices.","origin":"detail"},"contacts":[{"name":"Joanne Skaff","role":"primary","email":"joanne.skaff@va.gov","phone":"570-899-6581","title":"Contract Specialist"}],"place_of_performance":{"zip":"19104","city":{"name":"Philadelphia"},"state":{"name":"PA"},"street":"Department of Veterans Affairs Network Contracting Office 4","country":{"code":"USA","name":"UNITED STATES"},"street2":"Corporal Michael J. Crescenz VA Medical Center 3900 Woodland Avenue"},"office_address":{"zip":"15215","city":"PITTSBURGH","state":"PA","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"128fee3edcaf41bf99674cb88e5b112d","name":"36C24425Q0406.docx","kind":"file","mime_type":".docx","size_bytes":24969,"posted_at":"2025-02-27T16:56:28.937Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/128fee3edcaf41bf99674cb88e5b112d/download","mirrored":false}],"awards":[],"related":[{"key":"36C24427Q0050","latest_notice_id":"39a56ccb22e04e4e9193e8010bd8673f","title":"Burlodge Steam Table","solicitation_number":"36C24427Q0050","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":2,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"333241","psc":"7310","set_aside":"SBA","state":"PA","county":"42019","county_name":"Butler County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-18T06:18:24.437223Z"},{"key":"36C24427Q0079","latest_notice_id":"1aeaf708a3be40edb708dd1ab609c1ef","title":"6515--Phototherapy","solicitation_number":"36C24427Q0079","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-02T11:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24427Q0053","latest_notice_id":"7935eeaee4d94638addddf105e1e7449","title":"Q510--Bedside Somatosensory Evoked Potential (SSEP) Studies VA Pittsburgh Healthcare System","solicitation_number":"36C24427Q0053","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"621399","psc":"Q510","set_aside":null,"state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":"15240","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"36C24426R0088","latest_notice_id":"3dad80776d7f4e15b9869fedfbaa4bbe","title":"Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC","solicitation_number":"36C24426R0088","notice_type":"o","first_type":"p","first_posted":"2026-05-21","last_posted":"2026-11-20","notices":12,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"PA","county":"42101","county_name":"Philadelphia County","city":"4260000","city_name":"Philadelphia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Philadelphia VA Medical Center","site_key":"philadelphia-va-medical-center-pa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C24427Q0076","latest_notice_id":"b3bcac1db3434456afc02f514f52e327","title":"6515--Smart HemoSphere","solicitation_number":"36C24427Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:30:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C244","office_name":"244-NETWORK CONTRACT OFFICE 4 (36C244)","naics":"339112","psc":"6515","set_aside":null,"state":"DE","county":"10003","county_name":"New Castle County","city":"1077580","city_name":"Wilmington","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T01:26:57.794874Z"}],"similar_open":[{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C26227Q0152","latest_notice_id":"9b6180e4020d4cb29db1bd3cb54509c4","title":"6515--Battery Packs and Wi-Fi Cards","solicitation_number":"36C26227Q0152","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"339112","psc":"6515","set_aside":null,"state":"AZ","county":"04013","county_name":"Maricopa County","city":"0455000","city_name":"Phoenix","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":14,"indexable":false}