Combined synopsis and solicitation, total small business set-aside

FCC Lompoc B&F Project 25Z6AXX Emergency Fire Escape Doors

15B61727Q00000002

Federal Prison System / Bureau of Prisons, FCC Lompoc. Metal Window and Door Manufacturing.

Response deadline

November 16, 2026 at 4:00 PM EST

Closed 9 days ago. Posted November 10, 2026, first published November 5, 2026. Scheduled to archive December 1, 2026.

Get the next one like this from Federal Prison System / Bureau of Prisons by email, the day it is posted.Find my opportunities

This one closed 9 days ago

8 like it are open now in metal window and door manufacturing

All 8 open in metal window and door manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
Who may compete
Total small business set-aside. Only small businesses may compete. Small, under NAICS 332321 (metal window and door manufacturing), means no more than 750 employees, counted with affiliates. Open Small business opportunities
Time to respond
Bidders had 11 days from the day the solicitation was posted, November 5, 2026, to the deadline.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

                                                   STATEMENT OF WORK / REQUEST FOR QUOTE
A. INTRODUCTION:


1. The Federal Bureau of Prisons (FBOP), FCC Lompoc, 3901 Klein Blvd., Lompoc, CA 93436, is
seeking quotes from qualified vendors for the supply and delivery of nine (9) complete fire
escape door assemblies, including doors, frames, and all required hardware. The doors are for a
prison facility application and must meet all relevant local, state, and federal fire and life safety
codes.


2. "Equal or Better" Product Substitution: Proposals must meet or exceed the specified product
quality. If an alternative product or component is offered, the vendor must submit all technical
documentation, certifications, and test results for consideration.


3. Government's Right of Final Technical Acceptance: The government retains the sole and final
authority to determine technical acceptance for all submitted products, based on the provided
documentation and compliance with stated standards.


B. SCOPE OF WORK:


1. The vendor shall provide all materials as specified below. All components must be new, U.L.
Listed or labeled by a recognized testing agency acceptable to the Authority Having Jurisdiction
(AHJ) and conform to the standards referenced herein.


C. TECHNICAL SPECIFICATIONS:


TABLE 1: COMPONENTS: All units shall be identical unless otherwise noted.

  • Component
    • Requirement
  • Quantity
    • 9 Complete Door Assemblies
  • Door Size
    • 36" wide x 80" high x 2" thick
  • Door Material
    • Hollow Metal Door, minimum 12 Gauge galvanneal steel
  • Core
    • Ribbed and Insulated (mineral core for fire rating is acceptable/preferred)
  • Fire Rating
    • Rating must be compatible with the wall's fire resistance rating, typically 75% of the wall's rating. See required fire rating for correctional facilities on Table 2
  • Handing
    • 4 Left Hand Outswing, 5 Right Hand Outswing.
  • Frame Material
    • Minimum 12 Gauge galvanneal steel, fire-rated and labeled
  • Frame Type
    • Knock-down (KD) for drywall/unit masonry or welded for masonry. Frames are

to be prepared for 80 series lock, keyed 2 sides strike, surface pull on both
sides and prepped for PA closer.

  • Finish
    • Factory primed for field painting


TABLE 2: FIRE RATING:


The complete door assembly (door, frame, and all hardware) shall be 90 minutes fire rated. This rating
must be compatible with the fire-resistance rating of the specific wall assembly in which the door will be
installed, as dictated by the building's fire safety plan and local code requirements.
Category Requirement Description Applicable Standards &
Agencies

  • Listing & Labeling
    • All components must be listed and labeled by a recognized third-party testing agency acceptable to the Authority Having Jurisdiction (AHJ).
    • Underwriters Laboratories (UL), Intertek (WH), Factory Mutual (FM)
  • Testing Standard
    • Assemblies shall be tested under positive pressure conditions.

NFPA 252, ANSI/UL 10C

  • Labeling Visibility
    • A permanent, legible fire rating label must be affixed to both the door and the frame and remain visible after installation for inspection purposes.
    • N/A
  • Code Compliance
    • Vendor must confirm that all components, when installed as an assembly, comply with relevant building and safety codes for correctional facilities (Group I-3 Occupancies, IBC).
    • NFPA 80 (Standard for Fire Doors and Other Opening Protectives)
    • International Building Code (IBC)


TABLE 3: HARDWARE SPECIFICATIONS:


All hardware must be "listed" or "labeled" for use on a fire-rated assembly, compatible with the specified fire rating, and factory-prepped for ANSI/BHMA Grade 1 standards.


Item Requirement Quantity
per Door
Notes

  • Hinges
    • Heavy-duty steel ball bearing hinges, UL Listed
    • 3
  • Exit Device
    • Panic Hardware/Fire Exit Hardware (rim or mortise type) self-latching
    • 1 set
    • Must be a crossbar or touch bar device, operable with an applied force of 15 lbs or less.
  • Locking
    • Must be openable from the egress side at all times without special knowledge or tools. Keyed access from the exterior is permitted.
    • 1 set
    • 80 series lock, keyed 2 sides strike, surface pull on both sides and prepped for PA closer.
  • Door Closer
    • Heavy-duty, adjustable, surface-mounted, UL Listed
    • 1 unit
    • Must be self-closing and ensure positive latching.
  • Seals
    • Smoke and draft control gasketing/seals
    • 1 set
    • Required for a complete smoke-rated assembly.
  • Threshold
    • [Specify if required, e.g., 1/2" beveled aluminum, non-combustible]
    • 1 unit (if required)


D. CODE AND STANDARD REQUIREMENTS:


1. All supplied materials and the complete assembly must comply with the latest editions of the
following codes and standards (or local equivalents as adopted by the AHJ):

  • NFPA 80: Standard for Fire Doors and Other Opening Protectives
  • NFPA 101: Life Safety Code
  • International Building Code (IBC)
  • International Fire Code (IFC)
  • OSHA requirements for exit routes
  • UL 10C or NFPA 252: Standard for positive pressure fire testing of door assemblies
  • UL 1784: Standard for Air Leakage Tests of Door Assemblies (if smoke rating is required)


2. Vendors must confirm that all components, when installed as an assembly, will bear a permanent,
legible label from a recognized third-party testing agency (e.g., UL, Intertek/WH, FM).


E. SUBMISSION REQUIREMENTS:


1. Itemized pricing for doors, frames, hardware, and any included accessories.
2. Proposed lead time for manufacturing and delivery to FCC Lompoc
3. Confirmation of compliance with all referenced codes and standards.
4. Cut sheets/product data for all proposed items.


F. DELIVERY OF MATERIALS:


1. Deliveries shipped directly to FCC LOMPOC can only be received between 7:30 a.m. and 2:00
p.m., Monday through Friday, excluding Federal Holidays.


2. POC: Mr. Fernando Pena, BOP Engineering Technician, FXPena@bop.gov, or 805-735-2771


3. FBOP will be responsible for receiving or signing deliveries.


4. FCC LOMPOC will provide resources for loading and unloading materials or equipment upon
arrival.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. November 5, 2026

    Combined synopsis and solicitation

    Due November 16, 2026 at 4:00 PM EST. SAM.gov, notice 889b960037f64c288fd031fb8d5c49e3

    3 revisions on SAM
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 5, 2026: publish, combined synopsis and solicitation
  2. November 10, 2026

    Combined synopsis and solicitation

    Due November 16, 2026 at 4:00 PM EST. SAM.gov, notice 85dc0988f46f456f9a3b64348199eba0

    3 revisions on SAM
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 5, 2026: publish, combined synopsis and solicitation
  3. November 10, 2026

    Combined synopsis and solicitation

    Due November 16, 2026 at 4:00 PM EST. SAM.gov, notice b2b1451f15c44612a7284357613b5601

    3 revisions on SAM
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 10, 2026: publish, combined synopsis and solicitation
    • November 5, 2026: publish, combined synopsis and solicitation

Points of contact