Award notice, first published as combined synopsis and solicitation
FCC HAZELTON, FY25 SFF HOT WATER TANKS (PRODUCT ONLY)
15B12125Q00000008
Federal Prison System / Bureau of Prisons, Usp Hazelton. Plumbing, Heating, and Air-Conditioning Contractors.
Awarded
$98,080.00 obligated so far on USAspending
Get the next one like this from Federal Prison System / Bureau of Prisons by email, the day it is posted.Find my opportunities
This one was awarded in 2025
59 like it are open now in plumbing, heating, and air-conditioning contractors
- BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031
Department of Veterans Affairs, 262-Network Contract Office 22
Sources soughtSDVOSBNAICS 238220Loma Linda, CA36C26227Q0149Due tomorrowNov 27 - SOURCES SOUGHT NOTICE: Preventive Maintenance Services for Medical Gas and Vacuum Systems
Indian Health Service, Navajo Area Indian Health SVC
Sources soughtNAICS 238220Tonalea, AZIHS1532768Due tomorrowNov 27 - Remediation of storm damage to station multi-Purpose Bldg
US Coast Guard, Base New Orleans
Combined synopsis and solicitationSmall businessNAICS 238220Dauphin Island, AL30332Q270000002Due in 2 daysNov 28
All 59 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Award notice. Who won, when, and for how much. Glossary
- Time to respond
- Bidders had 20 days from the day the solicitation was posted, January 14, 2025, to the deadline.
- How it ended
- Awarded to Howland Pump & Supply Co Inc. on February 10, 2025, 7 days after offers were due. The contracting office reported 5 offers (competed under simplified acquisition procedures).
Description
As published on SAM.gov with the combined synopsis and solicitation of January 14, 2025.
FCC Hazelton requires a quantity of 4 each indirect plate and frame water heater plus 4 each pumps to accompany the water heaters. Vendors are required to have active SAM.Gov registration and to provide their UEI. A signed SF1449 must be submitted to be considered received. This requirement is for product ONLY. All quotes and bids are required to be submitted to Andrea Burke, Contract Specialist with FCC Hazelton at Ax2burke@bop.gov AND HAX-ProcurementProp-S@bop.gov. Quotes must be valid for at least 30 days after close of bids on February 3, 2025 at 2 PM EDT. Specific product requirements below and example spec sheets attached.
Indirect Plate And Frame Water Heater: (4)
Dimensions cannot Exceed: 63” Height Max; 22” Width max; 61” Base Length – MUST FIT THROUGH STANDARD 36” door. Product should not exceed 1200 lbs – Lite Weight Preferred
FEATURES:
ASME DOUBLE WALL HEAT EXCHANGER
• 316L Stainless Steel
• 150 psi Working Pressure
DIGITAL DISPLAY
• DHW Set Point Range 90°F to 180°F
ADVANCED TEMPERATURE CONTROL
MODULATING CONTROL VALVE
SCALE REDUCING PUMP
AUTOMATIC AIR VENT
ASME TEMPERATURE & PRESSURE RELIEF VALVE
• 210°F and 150 psi
ADJUSTABLE HIGH LIMIT
WYE STRAINERS - DOMESTIC PIPING AND
BOILER PIPING
ISOLATION VALVES - DOMESTIC PIPING AND BOILER PIPING
MODBUS COMMUNICATION
WARRANTY
• 5-Year limited warranty/1-Year limited parts
• Warranty for product only without services requirement
SUGGESTED SPECIFICATION
The Indirect Plate and Frame shall be constructed of a 316 stainless steel plate with EPDM gaskets. Maximum unit dimensions shall be: Length ___61_inches, Width ___22___inches and Height __63______ inches.
The Indirect Plate and Frame shall be a double wall. The plate and frame shall be constructed in accordance with the ASME Boiler and Pressure Vessel Code requirements, stamped and registered with the National Board of Boiler and Pressure Vessel Inspectors
The Indirect Plate and Frame shall have a 150 psi working pressure and be supplied with an ASME temperature and pressure relief valve. Standard equipment shall include Wye Strainers, Isolation Valves, Automatic Air Vent, Scale Reduction Pump, Adjustable High Limit and drain valve
The temperature control shall provide + or – 4 degrees Fahrenheit accuracy with up to a 50% change in load. Setpoint range between 90 and 180 F. Modbus communication shall be standard equipment. The modulating valve shall have a 1000 to 1 turndown. The Indirect Plate and Frame shall be suitable for use with polypropylene glycol, up to 50% concentration. The de-rate associated with the glycol will vary per glycol manufacturer.
Pump: (4) Specifications must meet all below requirements for pump withsystem control and monitoring key
Conditions of Service
Flow: 130 US GPM
Head: 32 ft
Efficiency: 68.6 %
Liquid: Water
Temperature: 60 °C
NPSH required: ft
Pump Data
Specific Gravity: 0.985
Maximum operating pressure: 12 bar
Liquid temperature range: -10 .. 110 °C
Maximum ambient temperature: 40 °C
Flange standard: GF
Pipe connection: GF65
Product number: On request
Motor Data
P1 max: 29 .. 1385 W
Mains frequency: 60 Hz
Enclosure class: X4D
Insulation class: F
Four (4) - Set flanges (2 per set) for line item 0001 tanks
B&G CAST IRON FLANGE PACK, 2" or equivalent
ADDITIONAL INFORMATION: Domestic inlet temp Set point. DHW set point 90 to 180 degrees. GPH for all units together or for each if separated. GPH is for each unit. Each system will supply at minimum hot water to 64-cells, 10-showers, 2-mop closet and 1-staff restroom. Boiler water entering temp 160-180 degrees. Boiler water Leaving temp 120-140 degrees BTU I am looking for specifics on this. -These units are in use 24/7-365 if that helps.
For singled cell showers, 10 to be used at a time with a maximum of up to 128.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 15B12125Q00000008 RFQ.pdf385 KB, January 14, 2025
- HW Tank Specs.pdf546 KB, January 14, 2025
- Pump Specs.pdf607 KB, January 14, 2025
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Howland Pump & Supply Co Inc.
- UEI
- M9BRDJBZ7AM4
- CAGE
- 1J3U9
- Vendor location
- Ogdensburg, NY
- Contract
- 15B12125P00000068, purchase order
- Obligated
- $98,080.00
- Actions
- 1 between February 10, 2025 and February 10, 2025
- Competition
- Competed Under SAP, 5 offers received
- Set-aside reported
- No Set Aside Used.
- Described as
- FY25 PZ 25Z1AC3 Replace SFF Unit HW Heaters
- Match
- award number 15B12125P00000068 equals the contract number; same awarding office 15B121 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 14, 2025
Combined synopsis and solicitation
FCC HAZELTON, FY25 Water Heating System- PRODUCT ONLY
Due February 3, 2025 at 2:00 PM EST. SAM.gov, notice 0b0541371fda4111b9e01867cb3f9caa
1 revision on SAM
- January 14, 2025: publish, combined synopsis and solicitation
February 10, 2025
Award notice
Awarded to Howland Pump & Supply Co Inc. for $98,080. SAM.gov, notice c0ada0584ad345fbad2c2ffe5e7e4fef
1 revision on SAM
- February 10, 2025: publish, award notice