{"canonical":"https://sealedbidder.com/opportunities/wwyk22006","key":"WWYK22006","url":"https://sealedbidder.com/opportunities/wwyk22006","title":"WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001","solicitation_number":"WWYK22006","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-20T19:00:00Z","first_posted":"2026-08-05","last_posted":"2026-08-05","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8137 AFSC PZIOC","naics":"236220","psc":null,"set_aside":"SBA","place_state":"OK","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"40109","place_county_name":"Oklahoma County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"f99700728ef24da6abdf27b0eb613e68","title":"WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001","solicitation_number":"WWYK22006","notice_type":"r","base_type":"r","posted":"2026-08-05","posted_at":"2026-08-05T14:51:52.639Z","due_at":"2026-08-20T19:00:00Z","due_date":"2026-08-20","cancelled":false,"archived":true,"archive_date":"2026-09-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f99700728ef24da6abdf27b0eb613e68/view","enriched":true,"history":[{"index":3,"title":"WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T14:51:52.639Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f99700728ef24da6abdf27b0eb613e68","solicitation_number":"WWYK22006"}]}],"latest_notice_id":"f99700728ef24da6abdf27b0eb613e68","first_type":"r","notices":[{"dates":{"posted":"2026-08-05","posted_at":"2026-08-05T14:51:52.639Z","created_at":"2026-07-30T17:49:16.927Z","modified_at":"2026-09-04T05:06:57.830Z","response_deadline":{"raw":"2026-08-20T14:00:00-05:00","utc":"2026-08-20T19:00:00Z","date":"2026-08-20","time":"14:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f99700728ef24da6abdf27b0eb613e68/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001","agency":{"office":{"code":"FA8137","name":"FA8137 AFSC PZIOC"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"73145-9125","city":"TINKER AFB","state":"OK","country":"USA"},"organization_id":"500042485","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-04","archive_type":"auto15"},"history":[{"index":3,"title":"WWYK220006 - RENOVATE CHILLED WATER CIRCUIT 3, B3001","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T14:51:52.639Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f99700728ef24da6abdf27b0eb613e68","solicitation_number":"WWYK22006"}],"contacts":[{"name":"Isaac Demmers","role":"primary","email":"isaac.demmers@us.af.mil"},{"name":"Darian Permetter","role":"secondary","email":"darian.permetter@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"f99700728ef24da6abdf27b0eb613e68","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"f99700728ef24da6abdf27b0eb613e68","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T02:59:29.514481589Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"89c78717fc5c0462a9605d456420fdd3c8dbe04047db12f9ff38473e9b74cdc2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T02:59:29.514481589Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p><strong><u>THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY</u></strong></p>\n\n<p>Tinker AFB (TAFB) Oklahoma is soliciting a source&rsquo;s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings.</p>\n\n<p>If respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&amp;A, Overhead, Profit and Bonds.</p>\n\n<p>WWYK220006 - Renovate Chilled Water Circuit 3, B3001. This is a Concept Design. Recommendations #13 para 5a on pgs 11-12 and #14 para 5.b on pg 12 of the Chilled Water Distribution Study by ZRHD on 5 Oct 2020. Circuit #3: remove old Circuit #3 piping to multiple fan decks and re-feed from new Circuit #3. Remove reverse return piping and connect to the new Circuit #3. Replace 2&quot; supply and return to AHU&#39;s PR65 and PR66 with 4&quot; supply and return piping. Eliminate tertiary pupmps CHWP-PR65 and CHWP-PR66. Relocate from over workspaces and mezzanines to the best located aisle for ease of access and maintenance.&nbsp;</p>\n\n<p>The work to be performed under the terms of this Order consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the removal of the existing Chilled Water Circuit #3 piping that extends to multiple fan decks. The work will also consist of installing a new Circuit #3, relocating the piping away from workspaces and mezzanines to the east aisle way when possible, for ease of access and maintenance and demolition of old steam lines at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information).</p>\n\n<p>The Contractor&rsquo;s work elements must fully comply with the Government&rsquo;s issued contract documents, as well as all governing codes, Tinker AFB Specifications, and Technical Specifications. &nbsp;The services to be performed under this contract are non-military unique and are commonly available in the local market area and have routinely been performed by companies within the small business set-aside, two step sealed bid program.</p>\n\n<p>Project specific documents are attached to this posting.</p>\n\n<p>If you are a prime contractor experiencing any difficulty at receiving or accessing the project specific documents, send an email request to Contracting Points of Contact listed.&nbsp;</p>\n\n<p>If you would like to express your interest in this project please Email SSgt Isaac Demmers at isaac.demmers@us.af.mil by 20 August 2026 @ 1400 (2:00 PM) CST, stating so.</p>\n\n<p><strong><u>THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY</u></strong></p>\n\n<p></p>","text":"THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY\n\nTinker AFB (TAFB) Oklahoma is soliciting a source’s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings.\n\nIf respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&A, Overhead, Profit and Bonds.\n\nWWYK220006 - Renovate Chilled Water Circuit 3, B3001. This is a Concept Design. Recommendations #13 para 5a on pgs 11-12 and #14 para 5.b on pg 12 of the Chilled Water Distribution Study by ZRHD on 5 Oct 2020. Circuit #3: remove old Circuit #3 piping to multiple fan decks and re-feed from new Circuit #3. Remove reverse return piping and connect to the new Circuit #3. Replace 2\" supply and return to AHU's PR65 and PR66 with 4\" supply and return piping. Eliminate tertiary pupmps CHWP-PR65 and CHWP-PR66. Relocate from over workspaces and mezzanines to the best located aisle for ease of access and maintenance.\n\nThe work to be performed under the terms of this Order consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the removal of the existing Chilled Water Circuit #3 piping that extends to multiple fan decks. The work will also consist of installing a new Circuit #3, relocating the piping away from workspaces and mezzanines to the east aisle way when possible, for ease of access and maintenance and demolition of old steam lines at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information).\n\nThe Contractor’s work elements must fully comply with the Government’s issued contract documents, as well as all governing codes, Tinker AFB Specifications, and Technical Specifications. The services to be performed under this contract are non-military unique and are commonly available in the local market area and have routinely been performed by companies within the small business set-aside, two step sealed bid program.\n\nProject specific documents are attached to this posting.\n\nIf you are a prime contractor experiencing any difficulty at receiving or accessing the project specific documents, send an email request to Contracting Points of Contact listed.\n\nIf you would like to express your interest in this project please Email SSgt Isaac Demmers at isaac.demmers@us.af.mil by 20 August 2026 @ 1400 (2:00 PM) CST, stating so.\n\nTHIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"WWYK22006","place_of_performance":{"zip":"73145","city":{"code":"0","name":"Tinker AFB"},"state":{"code":"OK","name":"Oklahoma"},"country":{"code":"USA","name":"UNITED STATES"}}}],"due_at":"2026-08-20T19:00:00Z","due_date":"2026-08-20","closes_at":"2026-08-20T19:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-26T03:17:36.221267Z","principal_notice_id":"f99700728ef24da6abdf27b0eb613e68","description":{"text":"THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY\n\nTinker AFB (TAFB) Oklahoma is soliciting a source’s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings.\n\nIf respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&A, Overhead, Profit and Bonds.\n\nWWYK220006 - Renovate Chilled Water Circuit 3, B3001. This is a Concept Design. Recommendations #13 para 5a on pgs 11-12 and #14 para 5.b on pg 12 of the Chilled Water Distribution Study by ZRHD on 5 Oct 2020. Circuit #3: remove old Circuit #3 piping to multiple fan decks and re-feed from new Circuit #3. Remove reverse return piping and connect to the new Circuit #3. Replace 2\" supply and return to AHU's PR65 and PR66 with 4\" supply and return piping. Eliminate tertiary pupmps CHWP-PR65 and CHWP-PR66. Relocate from over workspaces and mezzanines to the best located aisle for ease of access and maintenance.\n\nThe work to be performed under the terms of this Order consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the removal of the existing Chilled Water Circuit #3 piping that extends to multiple fan decks. The work will also consist of installing a new Circuit #3, relocating the piping away from workspaces and mezzanines to the east aisle way when possible, for ease of access and maintenance and demolition of old steam lines at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information).\n\nThe Contractor’s work elements must fully comply with the Government’s issued contract documents, as well as all governing codes, Tinker AFB Specifications, and Technical Specifications. The services to be performed under this contract are non-military unique and are commonly available in the local market area and have routinely been performed by companies within the small business set-aside, two step sealed bid program.\n\nProject specific documents are attached to this posting.\n\nIf you are a prime contractor experiencing any difficulty at receiving or accessing the project specific documents, send an email request to Contracting Points of Contact listed.\n\nIf you would like to express your interest in this project please Email SSgt Isaac Demmers at isaac.demmers@us.af.mil by 20 August 2026 @ 1400 (2:00 PM) CST, stating so.\n\nTHIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY","html":"<p><strong><u>THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY</u></strong></p>\n\n<p>Tinker AFB (TAFB) Oklahoma is soliciting a source&rsquo;s sought to see if there are any contractors capable of completing the requirements found in the attached project Statement of Work (SOW) and drawings.</p>\n\n<p>If respondent is only capable of being a General Contractor, please provide your average percentage for Design, G&amp;A, Overhead, Profit and Bonds.</p>\n\n<p>WWYK220006 - Renovate Chilled Water Circuit 3, B3001. This is a Concept Design. Recommendations #13 para 5a on pgs 11-12 and #14 para 5.b on pg 12 of the Chilled Water Distribution Study by ZRHD on 5 Oct 2020. Circuit #3: remove old Circuit #3 piping to multiple fan decks and re-feed from new Circuit #3. Remove reverse return piping and connect to the new Circuit #3. Replace 2&quot; supply and return to AHU&#39;s PR65 and PR66 with 4&quot; supply and return piping. Eliminate tertiary pupmps CHWP-PR65 and CHWP-PR66. Relocate from over workspaces and mezzanines to the best located aisle for ease of access and maintenance.&nbsp;</p>\n\n<p>The work to be performed under the terms of this Order consists of furnishing all design/engineering services, materials, labor, plant, tools, transportation, equipment, testing services, quality control and incidentals required to accomplish the removal of the existing Chilled Water Circuit #3 piping that extends to multiple fan decks. The work will also consist of installing a new Circuit #3, relocating the piping away from workspaces and mezzanines to the east aisle way when possible, for ease of access and maintenance and demolition of old steam lines at Tinker Air Force Base (AFB), Oklahoma (reference the project drawings for additional location information).</p>\n\n<p>The Contractor&rsquo;s work elements must fully comply with the Government&rsquo;s issued contract documents, as well as all governing codes, Tinker AFB Specifications, and Technical Specifications. &nbsp;The services to be performed under this contract are non-military unique and are commonly available in the local market area and have routinely been performed by companies within the small business set-aside, two step sealed bid program.</p>\n\n<p>Project specific documents are attached to this posting.</p>\n\n<p>If you are a prime contractor experiencing any difficulty at receiving or accessing the project specific documents, send an email request to Contracting Points of Contact listed.&nbsp;</p>\n\n<p>If you would like to express your interest in this project please Email SSgt Isaac Demmers at isaac.demmers@us.af.mil by 20 August 2026 @ 1400 (2:00 PM) CST, stating so.</p>\n\n<p><strong><u>THIS POSTING IS FOR TINKER AFB - MAC BOA HOLDER ONLY</u></strong></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Isaac Demmers","role":"primary","email":"isaac.demmers@us.af.mil"},{"name":"Darian Permetter","role":"secondary","email":"darian.permetter@us.af.mil"}],"place_of_performance":{"zip":"73145","city":{"code":"0","name":"Tinker AFB"},"state":{"code":"OK","name":"Oklahoma"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"73145-9125","city":"TINKER AFB","state":"OK","country":"USA"},"naics_codes":["236220"],"award":null,"attachments":[{"resource_id":"a615794555e54e998e731dcb92b5bd2f","name":"220006_ATT09_Design_Narrative_ CUI.pdf","kind":"file","mime_type":".pdf","size_bytes":2801062,"posted_at":"2026-08-05T14:51:52.639Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a615794555e54e998e731dcb92b5bd2f/download","mirrored":false}],"awards":[],"related":[{"key":"FA813726R0040","latest_notice_id":"49cbd90b4ddd456fb05b7337b27520f9","title":"Tinker AFB 2026 Multiple Award Construction Contract (MACC)","solicitation_number":"FA8137-26-R-0040","notice_type":"o","first_type":"o","first_posted":"2026-06-12","last_posted":"2026-11-20","notices":16,"due_at":"2026-12-03T19:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","naics":"236210","psc":"Z2JZ","set_aside":"SBP","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tinker Air Force Base","site_key":"tinker-air-force-base-ok","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"FA813727R0001","latest_notice_id":"66538ea7b89e46fa9a25cba734c3c330","title":"WWYK260004 - REPAIR STRUCTURAL INTEGRITY, B1134, POST 34 & NORTH WALL","solicitation_number":"FA813727R0001","notice_type":"o","first_type":"o","first_posted":"2026-10-16","last_posted":"2026-11-18","notices":6,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","naics":"238190","psc":"Z2GD","set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"FA813727R0002","latest_notice_id":"e10b191448a24612928a09cf65d5cd79","title":"WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19","solicitation_number":"FA813727R0002","notice_type":"o","first_type":"o","first_posted":"2026-10-05","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-18T20:00:00Z","due_date":"2026-12-18","closes_at":"2026-12-18T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","naics":"236220","psc":"Z1AA","set_aside":"WOSB","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"FA813726R0021","latest_notice_id":"2ec493f6357847498b0b00f3979ae8d0","title":"2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221","solicitation_number":"FA813726R0021","notice_type":"o","first_type":"o","first_posted":"2026-07-20","last_posted":"2026-10-29","notices":7,"due_at":"2026-12-30T20:00:00Z","due_date":"2026-12-30","closes_at":"2026-12-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","naics":"236220","psc":"Z1AA","set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tinker Air Force Base","site_key":"tinker-air-force-base-ok","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"FA813727R0005","latest_notice_id":"4b7c1d50fc2748deb7b1f1cfbc1229fe","title":"WWYK190217 Repair Perimeter Fence, SW Corner Base Housing","solicitation_number":"FA813727R0005","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2027-01-15T19:00:00Z","due_date":"2027-01-15","closes_at":"2027-01-15T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8137","office_name":"FA8137 AFSC PZIOC","naics":"238990","psc":"Z2PZ","set_aside":"WOSBSS","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"W912BV26RA016","latest_notice_id":"740b633947c4437eb506d23018133490","title":"Child Development Center (CDC), Tinker Air Force Base, Oklahoma","solicitation_number":"W912BV26RA016","notice_type":"o","first_type":"p","first_posted":"2026-08-13","last_posted":"2026-11-17","notices":7,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"236220","psc":"Y1CZ","set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":"4048350","city_name":"Midwest City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tinker Air Force Base","site_key":"tinker-air-force-base-ok","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"TPSBATHROOMUPGRADES","latest_notice_id":"0269b7f9e6d244f9b35d161bb47e033e","title":"Thomas P. Stafford Building (TPS) Restroom Upgrades at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK","solicitation_number":"TPSBathroomUpgrades","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-069","dept_name":"TRANSPORTATION, DEPARTMENT OF","sub_key":"s-6920","sub_name":"FEDERAL AVIATION ADMINISTRATION","office_key":"o-6973GH","office_name":"6973GH FRANCHISE ACQUISITION SVCS","naics":"236220","psc":"Y1AA","set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"140RR027R0020","latest_notice_id":"0ffc297fb8d04c08899fd3a921e6b7a7","title":"Y--McGee Creek Natural Scenic Recreation Area (NSRA) Improvements","solicitation_number":"140RR027R0020","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-04T22:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140RR0","office_name":"RECLAMATION CONTRACTING ACTIVITY","naics":"236220","psc":"Y1FB","set_aside":null,"state":"OK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ION AREA (NSRA) IMPROVEMENTS PROJECT IN OKLAHOMA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":191,"indexable":false}