Sources sought
Notice of Intent for Brand Name or Equal Door Hardware Systems and Network Control Systems for the Minneapolis Saint Paul Air Reserve Station (ARS).
W912QR_BrandName_MN
Department of the Army, W072 Endist Louisville. Commercial and Institutional Building Construction.
Response deadline
July 23, 2024 at 2:00 PM EDT
Closed 857 days ago. Posted July 9, 2024. Scheduled to archive August 7, 2024.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2024
191 like it are open now in commercial and institutional building construction
- Outdoor Fitness Facility, Building 389— Supply, Delivery, and Limited Installation Support
Department of the Air Force, FA6648 482 LSS LGC
Sources soughtNAICS 236220Ship to Homestead, FLHARBSS-2027-01Due todayNov 27 - 657-24-102JC - Prepare Site for New PET/CT, Room A011D (MD) FY27 NRM VISN Base, CON (VA-27-00017492) 657-27-1-8434-0001
Department of Veterans Affairs, 255-Network Contract Office 15
PresolicitationSDVOSBNAICS 236220Missouri36C25527R0016Due todayNov 27 - STATION-CONST TBD OIG RENOVATION
Department of Veterans Affairs, 242-Network Contract Office 02
Sources soughtSDVOSBNAICS 236220New York36C24227Q0135Due todayNov 27
All 191 open in commercial and institutional building construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of July 9, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The U.S. Army Corps of Engineers (USACE), Louisville District (LRL), will be soliciting a proposal for the contruction of a one-story 2,600 SF facility to provide cover and seclusion for inspection of commercial vehicles entering the installation at the Minneapolis Saint Paul Air Reserve Station (ARS). As part of the construction contract solicitation, the USACE intends to include the following Brand Name requirements:
A. Door Hardware: (1) Butt and Hinge Type: Lawrence Stanley Rizson-Firemark McKinney Hagar (2) Hinge Use: Exterior out swinging doors Type 1 x NRP Exterior in swinging doors Type 3 Interior doors with closers Type 3 or 4 Interior doors over 36 inches wide Type 3 Interior doors 36 inches or less without closer Type 4 Closet and other low frequency interior doors Type 5 Lead lined door pivots Type 6 (3) Hinge Size: 2 1/4-inch Doors 4½ inch by 4½ inch 1 3/4-inch Doors 4½ inch by 4½ inch 1 3/8-inch Doors 3½ inch by 3½ inch 1 1/8-inch Doors 3 inch by 3 inch (4) Number of Hinges: Doors over 90 inches 4 Butts Exterior and Vestibule Doors 4 Butts Dutch Doors 4 Butts Interior Doors 42 inches or wider 4 Butts Lead Lined Doors 4 Butts or Pivots Other Doors 3 Butts (5) Door sizes listed above are nominal opening sizes.
(6) Numbers listed are template type for metal doors or frames. Butts shall have flat button tips. Provide proper butt size to clear trim and allow full 180-degree door opening. Provide through bolts for butts on mineral core wood doors. Provide non-removable pins on all locked reverse bevel doors.
a. Exterior: Stainless steel.
b. Interior: Steel.
c. Options: Hospital tips.
B. Mechanical Locks and Latches: (1) Lockset Design: Sargent (2) Mortise Locks: Grade 1, 8200 (3) Interconnected Locks:
Grade 1 C. Auxiliary Locks and Latches:
Grade 1 D. Self-Contained Electronic Locks: Alarm Lock (1) Type: Mortise/Cylindrical (2) Actuating Device: Digital keypad. (3) Trilogy T2 DL2700 E. Door Bolts: (1) Dustproof Strikes: Grade 1 (2) Surface Bolts: Grade 1 (3) Manual Flush Bolts: Grade 1 (4) Automatic and Self-Latching Flush Bolts:
Grade 1 F. Exit Devices:
Grade 1:
(1)Exit Devices: Manufacturer Von Duprin a. Furnish exit devices for exterior and interior doors where room occupancy numbers and life safety codes require them. The type of device used shall be a Concealed Vertical Rod, Mortise or Rim type device. The style of the device should resemble or match the devices used in an adjoining area or elsewhere in the building. Use the Cross Bar Exit Device, only when matching existing devices adjoining a new area or existing as a standard elsewhere in the building.
Use the Touch Bar Device on all other applications. Lever Handles on the pull side of the door should match the style of the adjoining hardware, or the building standard lever style. Single door applications use the Rim Type, Mortise Lock Type, or Concealed Vertical Rod Type Exit Device. Pairs of doors with a Mullion, use the Rim Type Device.
Pairs of doors with (No Mullion) use two Concealed Vertical Rod Type, Concealed Vertical Rod and Mortise Lock Type or one pair of Automatic Flush Bolt and the Mortise Lock Type. b. Provide UL listed exit devices for labeled openings. All adjustments shall require the use of tamper proof tools or valve keys. c. Provide thru-bolts for labeled mineral core doors.
G. Cylinders and Keying: (1) Cylinders: To accept Small Format Interchangeable Core (SF/IC)(A2) a. Grade 1 b. Number of Pins: Seven c. Cores: Interchangeable (2) Construction Keying: Construction cores:
a. Construction cores will be provided by CE Lock shop when needed to secure the construction site. (3) Keying System: Not required. Owner will furnish pinned cores and keys. H. Key lock boxes furnished by CE lock shop.
I. Electric Strikes:
Grade 1-Manufacure: Von Duprin or HES.
J. Operating Trim: US26D K. Carry-open bars for pairs of doors L. Closers: Manufacturer -LCN (1) Surface: Grade 1 (2) Concealed: Grade 1 a. Size of closers for exterior doors shall be at least one size larger than manufacturer's recommendations. Size of closers for interior doors shall be in accordance with manufacturer's recommendations for individual door sizes and locations. Furnish closers larger than recommended for interior doors where necessary for proper operation of doors.
b. Supply drop plates, brackets, or adapters for arms as required to suit details. Where wall conditions permit, doors shall swing 180 degrees. Mount closers on back side of door wherever possible and not exposed on corridor side. At pair or bank of doors provide same closer installation and size, with size equal to largest closers required by bank of doors.
c. Provide back check for closers. Furnish hold-open where indicated. Furnish delayed action closer where indicated. Furnish closers for doors as noted in groups and in addition, furnish closers for labels and labeled construction doors whether or not specifically noted in group.
M. Protective Trim Units: Stainless steel unless otherwise specified.
N. Stops and Holders: (1) Provide doors with either wall stop or overhead stop (equipped with closers or not) unless specifically excepted. Do not mount wall stops on casework, cabinetwork, or equipment. Where wall stops are unsuitable, furnish an overhead stop or holder, GJ300HD Series, unless otherwise indicated. For special conditions use RB3, RB6 roller stops (where doors interfere). Wall stops: 50W, 60W, or WB11 at drywall walls (2" nominal wood blocking provided by Section 09260). WB11 wall stop mounted at 6'-6" from the floor. Floor stops: FB19X or FB13X (use only when unavoidable).
a. Stops and Bumpers: Grade 1.
b. Mechanical Door Holders: Grade 1.
c. Combination Floor and Wall Stops and Holders: Grade 1.
d. Combination Overhead Stops and Holders: Grade 1.
e. Electromagnetic door holders for fire door assemblies.
f. Silencers for metal door frames will be supplied by manufacturer.
Network Control Systems: Leviton Opt-X® and Leviton QuickPort® systems Current optics used: Leviton SPLCS-12L, SPLCS-24L, 5R1UH-S03 & 5R2UH-S06 fiber optic splice modules and enclosures for all our fiber optic needs. All responsible sources may submit a capability statement which shall be considered by the agency. The submission must be received no later than 2:00 PM ET 23 July 2024. THIS IS NOT A REQUEST FOR PROPOSAL.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 9, 2024
Sources sought
Due July 23, 2024 at 2:00 PM EDT. SAM.gov, notice 8c7408080567415eba1dc70697db09a3
Points of contact
- Alex Hamiltonalex.j.hamilton@usace.army.mil