{"canonical":"https://sealedbidder.com/opportunities/w912p625ra014","key":"W912P625RA014","url":"https://sealedbidder.com/opportunities/w912p625ra014","title":"Barrier I Spare Parts Procurement List (Misc)","solicitation_number":"W912P625RA014","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-22T20:30:00Z","first_posted":"2025-09-22","last_posted":"2025-09-22","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W072 ENDIST CHICAGO","naics":"335314","psc":"5998","set_aside":null,"place_state":"IL","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"17197","place_county_name":"Will County","place_city":"1744225","place_city_name":"Lockport","winner":null,"award_amount":null,"publications":[{"notice_id":"57d2dc11a16e4607b775dd52ff741bae","title":"Barrier I Spare Parts Procurement List (Misc)","solicitation_number":"W912P625RA014","notice_type":"s","base_type":"s","posted":"2025-09-22","posted_at":"2025-09-22T15:46:26.816Z","due_at":"2025-09-29T20:30:00Z","due_date":"2025-09-29","cancelled":false,"archived":true,"archive_date":"2025-10-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/57d2dc11a16e4607b775dd52ff741bae/view","enriched":true,"history":[{"index":3,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T17:11:51.195Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"f360e539944e45aa9145f6798d9691af","solicitation_number":"W912P625RA014","parent_opportunity_id":"57d2dc11a16e4607b775dd52ff741bae"},{"index":1,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T15:46:26.816Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"57d2dc11a16e4607b775dd52ff741bae","solicitation_number":"W912P625RA014"}]},{"notice_id":"f360e539944e45aa9145f6798d9691af","title":"Barrier I Spare Parts Procurement List (Misc)","solicitation_number":"W912P625RA014","notice_type":"s","base_type":"s","posted":"2025-09-22","posted_at":"2025-09-22T17:11:51.195Z","due_at":"2025-09-22T20:30:00Z","due_date":"2025-09-22","cancelled":false,"archived":true,"archive_date":"2025-10-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f360e539944e45aa9145f6798d9691af/view","enriched":true,"history":[{"index":3,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T17:11:51.195Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"f360e539944e45aa9145f6798d9691af","solicitation_number":"W912P625RA014","parent_opportunity_id":"57d2dc11a16e4607b775dd52ff741bae"},{"index":1,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T15:46:26.816Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"57d2dc11a16e4607b775dd52ff741bae","solicitation_number":"W912P625RA014"}]}],"latest_notice_id":"f360e539944e45aa9145f6798d9691af","first_type":"s","notices":[{"dates":{"posted":"2025-09-22","posted_at":"2025-09-22T15:46:26.816Z","created_at":"2025-09-22T15:42:28.286Z","modified_at":"2025-10-08T05:08:44.781Z","response_deadline":{"raw":"2025-09-29T15:30:00-05:00","utc":"2025-09-29T20:30:00Z","date":"2025-09-29","time":"15:30:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/57d2dc11a16e4607b775dd52ff741bae/view"},"naics":{"codes":["335314"],"primary":"335314"},"title":"Barrier I Spare Parts Procurement List (Misc)","agency":{"office":{"code":"W912P6","name":"W072 ENDIST CHICAGO"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"60604-1437","city":"CHICAGO","state":"IL","country":"USA"},"organization_id":"100221519","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-14","archive_type":"auto15"},"history":[{"index":3,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T17:11:51.195Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"f360e539944e45aa9145f6798d9691af","solicitation_number":"W912P625RA014","parent_opportunity_id":"57d2dc11a16e4607b775dd52ff741bae"},{"index":1,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T15:46:26.816Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"57d2dc11a16e4607b775dd52ff741bae","solicitation_number":"W912P625RA014"}],"contacts":[{"name":"Kyle Smith","role":"primary","email":"kyle.d.smith@usace.army.mil","phone":"3128465370"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"57d2dc11a16e4607b775dd52ff741bae","lineage_id":"57d2dc11a16e4607b775dd52ff741bae","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-29T00:38:31.079108222Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a73f302f9c7f522647648ae46ee1fc69f2536a7f7bb038ba4bc96ea8126e1031","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-29T00:38:31.079108222Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.</p>\n\n<p></p>\n\n<p>The Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary &amp; Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:</p>\n\n<p></p>\n\n<p>IGBT Module</p>\n\n<p>ABB</p>\n\n<p>5SJA 3000L520300 (DUFI11)</p>\n\n<p>8</p>\n\n<p>4160V Surge Arrestor</p>\n\n<p>ABB</p>\n\n<p>2GUS041500A110F</p>\n\n<p>1</p>\n\n<p>ControlLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-PA72</p>\n\n<p>2</p>\n\n<p>PLC Processor</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-L71</p>\n\n<p>2</p>\n\n<p>ControlLogix Ethernet/IP Communication Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2T</p>\n\n<p>2</p>\n\n<p>PLC Communication Module (Redundant)</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2TR</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16</p>\n\n<p>2</p>\n\n<p>PLC AC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16I</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB32</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB16E</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB32</p>\n\n<p>2</p>\n\n<p>PLC AC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OA16</p>\n\n<p>2</p>\n\n<p>PLC Relay Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OW16I</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF16</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF8K</p>\n\n<p>2</p>\n\n<p>PLC RTD/TC/mV Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IRT8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF4</p>\n\n<p>2</p>\n\n<p>MicroLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1763-L16DWD</p>\n\n<p>2</p>\n\n<p>MicroLogix Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1762-OF4</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP1F</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP2F</p>\n\n<p>2</p>\n\n<p>Terminal Block Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36Z24</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36A1</p>\n\n<p>10</p>\n\n<p>Master Control Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700S-CF620EJC</p>\n\n<p>2</p>\n\n<p>Large 8000 MicroFarad, 3000V, Capacitors</p>\n\n<p>AVX</p>\n\n<p>DKTFM961A8007</p>\n\n<p>7</p>\n\n<p>Pulse/Delay Function Generator - 1N</p>\n\n<p>BNC</p>\n\n<p>9522-L82-IA15-COM-S-US/575 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Surge Arrestor Power Resistor</p>\n\n<p>Carborundum</p>\n\n<p>888SP 75Ohm 10%P/M</p>\n\n<p>3</p>\n\n<p>Communication Network Switch</p>\n\n<p>CISCO</p>\n\n<p>IE-3200-8T2S-E</p>\n\n<p>2</p>\n\n<p>Managed Switch, Rack Mounted</p>\n\n<p>Cisco</p>\n\n<p>IE-4010-16S12P</p>\n\n<p>2</p>\n\n<p>Pneumatic Control Valve</p>\n\n<p>Clippard</p>\n\n<p>MME-44ZEEE-D024</p>\n\n<p>4</p>\n\n<p>Manifold</p>\n\n<p>Clippard</p>\n\n<p>MMM-44-02</p>\n\n<p>1</p>\n\n<p>Manifold Mounting Hardware</p>\n\n<p>Clippard</p>\n\n<p>27041-44</p>\n\n<p>1</p>\n\n<p>Electrical Noise Filter</p>\n\n<p>CORCOM</p>\n\n<p>20EQ1</p>\n\n<p>3</p>\n\n<p>Thin Client</p>\n\n<p>Dell</p>\n\n<p>Wyse 5070</p>\n\n<p>2</p>\n\n<p>4160V HVPS Main Circuit Interruptor</p>\n\n<p>Eaton</p>\n\n<p>Type: 50 VCP-TR 40&nbsp;&nbsp;&nbsp;&nbsp; Style - Option Number: 67A3092G64 - 40440601000540001000</p>\n\n<p>1</p>\n\n<p>Power Factor Correction Capacitor</p>\n\n<p>EnerLux</p>\n\n<p>MFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)</p>\n\n<p>2</p>\n\n<p>SCR Trigger Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>MVTB66STF7.2/PCS-4-94</p>\n\n<p>2</p>\n\n<p>SCR Regulator Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>ISOVLCL2X/PCS-4-91</p>\n\n<p>2</p>\n\n<p>SCR Multiplex board</p>\n\n<p>Enerpro</p>\n\n<p>1202602XX201A/PCS-4-90-12-FO</p>\n\n<p>2</p>\n\n<p>HVPPS Pneumatic Cylinder</p>\n\n<p>Fabco Air, Inc.</p>\n\n<p>HPS0021580</p>\n\n<p>2</p>\n\n<p>SCR Fuse</p>\n\n<p>Ferraz Shawmut/ Merson?</p>\n\n<p>PC94UD17C14CTD/ FUS-C17C14TA</p>\n\n<p>24</p>\n\n<p>HMI Touchscreen Panel</p>\n\n<p>Hope Industries</p>\n\n<p>HIS-ML23-STAD</p>\n\n<p>2</p>\n\n<p>Bleed Resistors (Fast) Assembly</p>\n\n<p>HVR Advanced Power Components</p>\n\n<p>J05PDA200K</p>\n\n<p>4</p>\n\n<p>General Purpose Relay</p>\n\n<p>IDEC</p>\n\n<p>RH4B-UL</p>\n\n<p>10</p>\n\n<p>Cap Bank Current Transformer</p>\n\n<p>LEM</p>\n\n<p>LF 1005-S/SP33</p>\n\n<p>16</p>\n\n<p>Fiber Optic Patch Panel</p>\n\n<p>Leviton</p>\n\n<p>5WMNT-01C</p>\n\n<p>2</p>\n\n<p>1&quot; NPTM Flow Switch</p>\n\n<p>McDonnell &amp; Miller</p>\n\n<p>FS254</p>\n\n<p>2</p>\n\n<p>Cooling Fan Blade</p>\n\n<p>MultiWing/Neeltran</p>\n\n<p>24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1&nbsp;&nbsp; Neeltran part number)</p>\n\n<p>2</p>\n\n<p>Current Transducer</p>\n\n<p>Ohio Semitronics Inc.</p>\n\n<p>CTLC-252SDT</p>\n\n<p>2</p>\n\n<p>Compact RTD Temperature Probe/Sensor</p>\n\n<p>Omega</p>\n\n<p>RTDM12-1/8NPT-3MM-24MM-A</p>\n\n<p>2</p>\n\n<p>1/4&quot; Stainless Steel Pressure Transducers</p>\n\n<p>Omega</p>\n\n<p>&nbsp;PX319-100G10V</p>\n\n<p>4</p>\n\n<p>Output Isolation Diodes</p>\n\n<p>Poseico</p>\n\n<p>DAI-16C36C (Poseico P/N AR2009S36)</p>\n\n<p>40</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>SCR-30C40C (Poseico P/N AT870S40)</p>\n\n<p>2</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>AT1228S36/SCR-13C36C (Poseico P/N AT1228S32)</p>\n\n<p>24</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98006RFR2SW1P1</p>\n\n<p>4</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98008RFR10SW1P1</p>\n\n<p>2</p>\n\n<p>1&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98016RFR60SW1P1</p>\n\n<p>2</p>\n\n<p>Pulse/Delay Function Generator - 1S</p>\n\n<p>Quantum</p>\n\n<p>9520 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Communication Network Switch (Protocol Converter)</p>\n\n<p>Red Lion</p>\n\n<p>DSPLE000</p>\n\n<p>2</p>\n\n<p>Ross Relay on Fast Bleed Assembly</p>\n\n<p>Ross Engineering</p>\n\n<p>EA12-NC-20-1-15-DI/BD</p>\n\n<p>2</p>\n\n<p>4160V Protective Relay (SEL)</p>\n\n<p>Schweitzer</p>\n\n<p>0787EX2B0X0X75850220/SEL-787</p>\n\n<p>2</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.355</p>\n\n<p>3</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.25</p>\n\n<p>3</p>\n\n<p>4160V Surge Arrestor Fuse</p>\n\n<p>SIBA</p>\n\n<p>FUHV-07K016/3000213.16</p>\n\n<p>3</p>\n\n<p>Transformer - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>KT8050P</p>\n\n<p>2</p>\n\n<p>Motor Contactor Rebuild Kit - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>75DF14</p>\n\n<p>2</p>\n\n<p>Motor Starter Overload Relay - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>48ATC3S00</p>\n\n<p>2</p>\n\n<p>Motor Breaker</p>\n\n<p>Siemens</p>\n\n<p>3RV2011-1GA10</p>\n\n<p>2</p>\n\n<p>Power Contactors</p>\n\n<p>Siemens</p>\n\n<p>3RT2024-1BB40</p>\n\n<p>2</p>\n\n<p></p>\n\n<p>The proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.</p>\n\n<p></p>\n\n<p>This notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 29, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.</p>\n\n<p>Contracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.</p>","text":"By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.\n\nThe Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary & Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:\n\nIGBT Module\n\nABB\n\n5SJA 3000L520300 (DUFI11)\n\n8\n\n4160V Surge Arrestor\n\nABB\n\n2GUS041500A110F\n\n1\n\nControlLogix Power Supply\n\nAllen Bradley\n\n1756-PA72\n\n2\n\nPLC Processor\n\nAllen Bradley\n\n1756-L71\n\n2\n\nControlLogix Ethernet/IP Communication Module\n\nAllen Bradley\n\n1756-EN2T\n\n2\n\nPLC Communication Module (Redundant)\n\nAllen Bradley\n\n1756-EN2TR\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB16\n\n2\n\nPLC AC Input Module\n\nAllen Bradley\n\n1756-IB16I\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB32\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB16E\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB32\n\n2\n\nPLC AC Output Module\n\nAllen Bradley\n\n1756-OA16\n\n2\n\nPLC Relay Output Module\n\nAllen Bradley\n\n1756-OW16I\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF16\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF8K\n\n2\n\nPLC RTD/TC/mV Module\n\nAllen Bradley\n\n1756-IRT8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF4\n\n2\n\nMicroLogix Power Supply\n\nAllen Bradley\n\n1763-L16DWD\n\n2\n\nMicroLogix Analog Output Module\n\nAllen Bradley\n\n1762-OF4\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP1F\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP2F\n\n2\n\nTerminal Block Relay\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36Z24\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36A1\n\n10\n\nMaster Control Relay\n\nAllen Bradley\n\n700S-CF620EJC\n\n2\n\nLarge 8000 MicroFarad, 3000V, Capacitors\n\nAVX\n\nDKTFM961A8007\n\n7\n\nPulse/Delay Function Generator - 1N\n\nBNC\n\n9522-L82-IA15-COM-S-US/575 - 2 Channels\n\n1\n\nSurge Arrestor Power Resistor\n\nCarborundum\n\n888SP 75Ohm 10%P/M\n\n3\n\nCommunication Network Switch\n\nCISCO\n\nIE-3200-8T2S-E\n\n2\n\nManaged Switch, Rack Mounted\n\nCisco\n\nIE-4010-16S12P\n\n2\n\nPneumatic Control Valve\n\nClippard\n\nMME-44ZEEE-D024\n\n4\n\nManifold\n\nClippard\n\nMMM-44-02\n\n1\n\nManifold Mounting Hardware\n\nClippard\n\n27041-44\n\n1\n\nElectrical Noise Filter\n\nCORCOM\n\n20EQ1\n\n3\n\nThin Client\n\nDell\n\nWyse 5070\n\n2\n\n4160V HVPS Main Circuit Interruptor\n\nEaton\n\nType: 50 VCP-TR 40 Style - Option Number: 67A3092G64 - 40440601000540001000\n\n1\n\nPower Factor Correction Capacitor\n\nEnerLux\n\nMFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)\n\n2\n\nSCR Trigger Circuit Board\n\nEnerpro\n\nMVTB66STF7.2/PCS-4-94\n\n2\n\nSCR Regulator Circuit Board\n\nEnerpro\n\nISOVLCL2X/PCS-4-91\n\n2\n\nSCR Multiplex board\n\nEnerpro\n\n1202602XX201A/PCS-4-90-12-FO\n\n2\n\nHVPPS Pneumatic Cylinder\n\nFabco Air, Inc.\n\nHPS0021580\n\n2\n\nSCR Fuse\n\nFerraz Shawmut/ Merson?\n\nPC94UD17C14CTD/ FUS-C17C14TA\n\n24\n\nHMI Touchscreen Panel\n\nHope Industries\n\nHIS-ML23-STAD\n\n2\n\nBleed Resistors (Fast) Assembly\n\nHVR Advanced Power Components\n\nJ05PDA200K\n\n4\n\nGeneral Purpose Relay\n\nIDEC\n\nRH4B-UL\n\n10\n\nCap Bank Current Transformer\n\nLEM\n\nLF 1005-S/SP33\n\n16\n\nFiber Optic Patch Panel\n\nLeviton\n\n5WMNT-01C\n\n2\n\n1\" NPTM Flow Switch\n\nMcDonnell & Miller\n\nFS254\n\n2\n\nCooling Fan Blade\n\nMultiWing/Neeltran\n\n24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1 Neeltran part number)\n\n2\n\nCurrent Transducer\n\nOhio Semitronics Inc.\n\nCTLC-252SDT\n\n2\n\nCompact RTD Temperature Probe/Sensor\n\nOmega\n\nRTDM12-1/8NPT-3MM-24MM-A\n\n2\n\n1/4\" Stainless Steel Pressure Transducers\n\nOmega\n\nPX319-100G10V\n\n4\n\nOutput Isolation Diodes\n\nPoseico\n\nDAI-16C36C (Poseico P/N AR2009S36)\n\n40\n\nSCRs\n\nPoseico Power Electronics\n\nSCR-30C40C (Poseico P/N AT870S40)\n\n2\n\nSCRs\n\nPoseico Power Electronics\n\nAT1228S36/SCR-13C36C (Poseico P/N AT1228S32)\n\n24\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98006RFR2SW1P1\n\n4\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98008RFR10SW1P1\n\n2\n\n1\" Flow Meter/Sensor\n\nProteus\n\n98016RFR60SW1P1\n\n2\n\nPulse/Delay Function Generator - 1S\n\nQuantum\n\n9520 - 2 Channels\n\n1\n\nCommunication Network Switch (Protocol Converter)\n\nRed Lion\n\nDSPLE000\n\n2\n\nRoss Relay on Fast Bleed Assembly\n\nRoss Engineering\n\nEA12-NC-20-1-15-DI/BD\n\n2\n\n4160V Protective Relay (SEL)\n\nSchweitzer\n\n0787EX2B0X0X75850220/SEL-787\n\n2\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.355\n\n3\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.25\n\n3\n\n4160V Surge Arrestor Fuse\n\nSIBA\n\nFUHV-07K016/3000213.16\n\n3\n\nTransformer - Cooling Pump\n\nSiemens\n\nKT8050P\n\n2\n\nMotor Contactor Rebuild Kit - Cooling Pump\n\nSiemens\n\n75DF14\n\n2\n\nMotor Starter Overload Relay - Cooling Pump\n\nSiemens\n\n48ATC3S00\n\n2\n\nMotor Breaker\n\nSiemens\n\n3RV2011-1GA10\n\n2\n\nPower Contactors\n\nSiemens\n\n3RT2024-1BB40\n\n2\n\nThe proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.\n\nThis notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 29, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.\n\nContracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"W912P625RA014","place_of_performance":{"zip":"60441","city":{"code":"44225","name":"Lockport"},"state":{"code":"IL","name":"Illinois"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5998"},{"dates":{"posted":"2025-09-22","posted_at":"2025-09-22T17:11:51.195Z","created_at":"2025-09-22T17:10:37.937Z","modified_at":"2025-10-08T05:08:44.781Z","response_deadline":{"raw":"2025-09-22T15:30:00-05:00","utc":"2025-09-22T20:30:00Z","date":"2025-09-22","time":"15:30:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f360e539944e45aa9145f6798d9691af/view"},"naics":{"codes":["335314"],"primary":"335314"},"title":"Barrier I Spare Parts Procurement List (Misc)","agency":{"office":{"code":"W912P6","name":"W072 ENDIST CHICAGO"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"60604-1437","city":"CHICAGO","state":"IL","country":"USA"},"organization_id":"100221519","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-07","archive_type":"auto15"},"history":[{"index":3,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T17:11:51.195Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"f360e539944e45aa9145f6798d9691af","solicitation_number":"W912P625RA014","parent_opportunity_id":"57d2dc11a16e4607b775dd52ff741bae"},{"index":1,"title":"Barrier I Spare Parts Procurement List (Misc)","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-22T15:46:26.816Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"57d2dc11a16e4607b775dd52ff741bae","solicitation_number":"W912P625RA014"}],"contacts":[{"name":"Kyle Smith","role":"primary","email":"kyle.d.smith@usace.army.mil","phone":"3128465370"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"f360e539944e45aa9145f6798d9691af","lineage_id":"57d2dc11a16e4607b775dd52ff741bae","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-29T01:23:52.103111484Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"caf94935c9b7b7b945a43e0d88333b19652594186e3b29262907aa8849043978","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-29T01:23:52.103111484Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.</p>\n\n<p></p>\n\n<p>The Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary &amp; Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:</p>\n\n<p></p>\n\n<p>IGBT Module</p>\n\n<p>ABB</p>\n\n<p>5SJA 3000L520300 (DUFI11)</p>\n\n<p>8</p>\n\n<p>4160V Surge Arrestor</p>\n\n<p>ABB</p>\n\n<p>2GUS041500A110F</p>\n\n<p>1</p>\n\n<p>ControlLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-PA72</p>\n\n<p>2</p>\n\n<p>PLC Processor</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-L71</p>\n\n<p>2</p>\n\n<p>ControlLogix Ethernet/IP Communication Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2T</p>\n\n<p>2</p>\n\n<p>PLC Communication Module (Redundant)</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2TR</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16</p>\n\n<p>2</p>\n\n<p>PLC AC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16I</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB32</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB16E</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB32</p>\n\n<p>2</p>\n\n<p>PLC AC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OA16</p>\n\n<p>2</p>\n\n<p>PLC Relay Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OW16I</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF16</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF8K</p>\n\n<p>2</p>\n\n<p>PLC RTD/TC/mV Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IRT8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF4</p>\n\n<p>2</p>\n\n<p>MicroLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1763-L16DWD</p>\n\n<p>2</p>\n\n<p>MicroLogix Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1762-OF4</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP1F</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP2F</p>\n\n<p>2</p>\n\n<p>Terminal Block Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36Z24</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36A1</p>\n\n<p>10</p>\n\n<p>Master Control Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700S-CF620EJC</p>\n\n<p>2</p>\n\n<p>Large 8000 MicroFarad, 3000V, Capacitors</p>\n\n<p>AVX</p>\n\n<p>DKTFM961A8007</p>\n\n<p>7</p>\n\n<p>Pulse/Delay Function Generator - 1N</p>\n\n<p>BNC</p>\n\n<p>9522-L82-IA15-COM-S-US/575 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Surge Arrestor Power Resistor</p>\n\n<p>Carborundum</p>\n\n<p>888SP 75Ohm 10%P/M</p>\n\n<p>3</p>\n\n<p>Communication Network Switch</p>\n\n<p>CISCO</p>\n\n<p>IE-3200-8T2S-E</p>\n\n<p>2</p>\n\n<p>Managed Switch, Rack Mounted</p>\n\n<p>Cisco</p>\n\n<p>IE-4010-16S12P</p>\n\n<p>2</p>\n\n<p>Pneumatic Control Valve</p>\n\n<p>Clippard</p>\n\n<p>MME-44ZEEE-D024</p>\n\n<p>4</p>\n\n<p>Manifold</p>\n\n<p>Clippard</p>\n\n<p>MMM-44-02</p>\n\n<p>1</p>\n\n<p>Manifold Mounting Hardware</p>\n\n<p>Clippard</p>\n\n<p>27041-44</p>\n\n<p>1</p>\n\n<p>Electrical Noise Filter</p>\n\n<p>CORCOM</p>\n\n<p>20EQ1</p>\n\n<p>3</p>\n\n<p>Thin Client</p>\n\n<p>Dell</p>\n\n<p>Wyse 5070</p>\n\n<p>2</p>\n\n<p>4160V HVPS Main Circuit Interruptor</p>\n\n<p>Eaton</p>\n\n<p>Type: 50 VCP-TR 40&nbsp;&nbsp;&nbsp;&nbsp; Style - Option Number: 67A3092G64 - 40440601000540001000</p>\n\n<p>1</p>\n\n<p>Power Factor Correction Capacitor</p>\n\n<p>EnerLux</p>\n\n<p>MFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)</p>\n\n<p>2</p>\n\n<p>SCR Trigger Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>MVTB66STF7.2/PCS-4-94</p>\n\n<p>2</p>\n\n<p>SCR Regulator Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>ISOVLCL2X/PCS-4-91</p>\n\n<p>2</p>\n\n<p>SCR Multiplex board</p>\n\n<p>Enerpro</p>\n\n<p>1202602XX201A/PCS-4-90-12-FO</p>\n\n<p>2</p>\n\n<p>HVPPS Pneumatic Cylinder</p>\n\n<p>Fabco Air, Inc.</p>\n\n<p>HPS0021580</p>\n\n<p>2</p>\n\n<p>SCR Fuse</p>\n\n<p>Ferraz Shawmut/ Merson?</p>\n\n<p>PC94UD17C14CTD/ FUS-C17C14TA</p>\n\n<p>24</p>\n\n<p>HMI Touchscreen Panel</p>\n\n<p>Hope Industries</p>\n\n<p>HIS-ML23-STAD</p>\n\n<p>2</p>\n\n<p>Bleed Resistors (Fast) Assembly</p>\n\n<p>HVR Advanced Power Components</p>\n\n<p>J05PDA200K</p>\n\n<p>4</p>\n\n<p>General Purpose Relay</p>\n\n<p>IDEC</p>\n\n<p>RH4B-UL</p>\n\n<p>10</p>\n\n<p>Cap Bank Current Transformer</p>\n\n<p>LEM</p>\n\n<p>LF 1005-S/SP33</p>\n\n<p>16</p>\n\n<p>Fiber Optic Patch Panel</p>\n\n<p>Leviton</p>\n\n<p>5WMNT-01C</p>\n\n<p>2</p>\n\n<p>1&quot; NPTM Flow Switch</p>\n\n<p>McDonnell &amp; Miller</p>\n\n<p>FS254</p>\n\n<p>2</p>\n\n<p>Cooling Fan Blade</p>\n\n<p>MultiWing/Neeltran</p>\n\n<p>24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1&nbsp;&nbsp; Neeltran part number)</p>\n\n<p>2</p>\n\n<p>Current Transducer</p>\n\n<p>Ohio Semitronics Inc.</p>\n\n<p>CTLC-252SDT</p>\n\n<p>2</p>\n\n<p>Compact RTD Temperature Probe/Sensor</p>\n\n<p>Omega</p>\n\n<p>RTDM12-1/8NPT-3MM-24MM-A</p>\n\n<p>2</p>\n\n<p>1/4&quot; Stainless Steel Pressure Transducers</p>\n\n<p>Omega</p>\n\n<p>&nbsp;PX319-100G10V</p>\n\n<p>4</p>\n\n<p>Output Isolation Diodes</p>\n\n<p>Poseico</p>\n\n<p>DAI-16C36C (Poseico P/N AR2009S36)</p>\n\n<p>40</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>SCR-30C40C (Poseico P/N AT870S40)</p>\n\n<p>2</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>AT1228S36/SCR-13C36C (Poseico P/N AT1228S32)</p>\n\n<p>24</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98006RFR2SW1P1</p>\n\n<p>4</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98008RFR10SW1P1</p>\n\n<p>2</p>\n\n<p>1&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98016RFR60SW1P1</p>\n\n<p>2</p>\n\n<p>Pulse/Delay Function Generator - 1S</p>\n\n<p>Quantum</p>\n\n<p>9520 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Communication Network Switch (Protocol Converter)</p>\n\n<p>Red Lion</p>\n\n<p>DSPLE000</p>\n\n<p>2</p>\n\n<p>Ross Relay on Fast Bleed Assembly</p>\n\n<p>Ross Engineering</p>\n\n<p>EA12-NC-20-1-15-DI/BD</p>\n\n<p>2</p>\n\n<p>4160V Protective Relay (SEL)</p>\n\n<p>Schweitzer</p>\n\n<p>0787EX2B0X0X75850220/SEL-787</p>\n\n<p>2</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.355</p>\n\n<p>3</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.25</p>\n\n<p>3</p>\n\n<p>4160V Surge Arrestor Fuse</p>\n\n<p>SIBA</p>\n\n<p>FUHV-07K016/3000213.16</p>\n\n<p>3</p>\n\n<p>Transformer - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>KT8050P</p>\n\n<p>2</p>\n\n<p>Motor Contactor Rebuild Kit - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>75DF14</p>\n\n<p>2</p>\n\n<p>Motor Starter Overload Relay - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>48ATC3S00</p>\n\n<p>2</p>\n\n<p>Motor Breaker</p>\n\n<p>Siemens</p>\n\n<p>3RV2011-1GA10</p>\n\n<p>2</p>\n\n<p>Power Contactors</p>\n\n<p>Siemens</p>\n\n<p>3RT2024-1BB40</p>\n\n<p>2</p>\n\n<p></p>\n\n<p>The proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.</p>\n\n<p></p>\n\n<p>This notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 22, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.</p>\n\n<p>Contracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.</p>","text":"By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.\n\nThe Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary & Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:\n\nIGBT Module\n\nABB\n\n5SJA 3000L520300 (DUFI11)\n\n8\n\n4160V Surge Arrestor\n\nABB\n\n2GUS041500A110F\n\n1\n\nControlLogix Power Supply\n\nAllen Bradley\n\n1756-PA72\n\n2\n\nPLC Processor\n\nAllen Bradley\n\n1756-L71\n\n2\n\nControlLogix Ethernet/IP Communication Module\n\nAllen Bradley\n\n1756-EN2T\n\n2\n\nPLC Communication Module (Redundant)\n\nAllen Bradley\n\n1756-EN2TR\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB16\n\n2\n\nPLC AC Input Module\n\nAllen Bradley\n\n1756-IB16I\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB32\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB16E\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB32\n\n2\n\nPLC AC Output Module\n\nAllen Bradley\n\n1756-OA16\n\n2\n\nPLC Relay Output Module\n\nAllen Bradley\n\n1756-OW16I\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF16\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF8K\n\n2\n\nPLC RTD/TC/mV Module\n\nAllen Bradley\n\n1756-IRT8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF4\n\n2\n\nMicroLogix Power Supply\n\nAllen Bradley\n\n1763-L16DWD\n\n2\n\nMicroLogix Analog Output Module\n\nAllen Bradley\n\n1762-OF4\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP1F\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP2F\n\n2\n\nTerminal Block Relay\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36Z24\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36A1\n\n10\n\nMaster Control Relay\n\nAllen Bradley\n\n700S-CF620EJC\n\n2\n\nLarge 8000 MicroFarad, 3000V, Capacitors\n\nAVX\n\nDKTFM961A8007\n\n7\n\nPulse/Delay Function Generator - 1N\n\nBNC\n\n9522-L82-IA15-COM-S-US/575 - 2 Channels\n\n1\n\nSurge Arrestor Power Resistor\n\nCarborundum\n\n888SP 75Ohm 10%P/M\n\n3\n\nCommunication Network Switch\n\nCISCO\n\nIE-3200-8T2S-E\n\n2\n\nManaged Switch, Rack Mounted\n\nCisco\n\nIE-4010-16S12P\n\n2\n\nPneumatic Control Valve\n\nClippard\n\nMME-44ZEEE-D024\n\n4\n\nManifold\n\nClippard\n\nMMM-44-02\n\n1\n\nManifold Mounting Hardware\n\nClippard\n\n27041-44\n\n1\n\nElectrical Noise Filter\n\nCORCOM\n\n20EQ1\n\n3\n\nThin Client\n\nDell\n\nWyse 5070\n\n2\n\n4160V HVPS Main Circuit Interruptor\n\nEaton\n\nType: 50 VCP-TR 40 Style - Option Number: 67A3092G64 - 40440601000540001000\n\n1\n\nPower Factor Correction Capacitor\n\nEnerLux\n\nMFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)\n\n2\n\nSCR Trigger Circuit Board\n\nEnerpro\n\nMVTB66STF7.2/PCS-4-94\n\n2\n\nSCR Regulator Circuit Board\n\nEnerpro\n\nISOVLCL2X/PCS-4-91\n\n2\n\nSCR Multiplex board\n\nEnerpro\n\n1202602XX201A/PCS-4-90-12-FO\n\n2\n\nHVPPS Pneumatic Cylinder\n\nFabco Air, Inc.\n\nHPS0021580\n\n2\n\nSCR Fuse\n\nFerraz Shawmut/ Merson?\n\nPC94UD17C14CTD/ FUS-C17C14TA\n\n24\n\nHMI Touchscreen Panel\n\nHope Industries\n\nHIS-ML23-STAD\n\n2\n\nBleed Resistors (Fast) Assembly\n\nHVR Advanced Power Components\n\nJ05PDA200K\n\n4\n\nGeneral Purpose Relay\n\nIDEC\n\nRH4B-UL\n\n10\n\nCap Bank Current Transformer\n\nLEM\n\nLF 1005-S/SP33\n\n16\n\nFiber Optic Patch Panel\n\nLeviton\n\n5WMNT-01C\n\n2\n\n1\" NPTM Flow Switch\n\nMcDonnell & Miller\n\nFS254\n\n2\n\nCooling Fan Blade\n\nMultiWing/Neeltran\n\n24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1 Neeltran part number)\n\n2\n\nCurrent Transducer\n\nOhio Semitronics Inc.\n\nCTLC-252SDT\n\n2\n\nCompact RTD Temperature Probe/Sensor\n\nOmega\n\nRTDM12-1/8NPT-3MM-24MM-A\n\n2\n\n1/4\" Stainless Steel Pressure Transducers\n\nOmega\n\nPX319-100G10V\n\n4\n\nOutput Isolation Diodes\n\nPoseico\n\nDAI-16C36C (Poseico P/N AR2009S36)\n\n40\n\nSCRs\n\nPoseico Power Electronics\n\nSCR-30C40C (Poseico P/N AT870S40)\n\n2\n\nSCRs\n\nPoseico Power Electronics\n\nAT1228S36/SCR-13C36C (Poseico P/N AT1228S32)\n\n24\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98006RFR2SW1P1\n\n4\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98008RFR10SW1P1\n\n2\n\n1\" Flow Meter/Sensor\n\nProteus\n\n98016RFR60SW1P1\n\n2\n\nPulse/Delay Function Generator - 1S\n\nQuantum\n\n9520 - 2 Channels\n\n1\n\nCommunication Network Switch (Protocol Converter)\n\nRed Lion\n\nDSPLE000\n\n2\n\nRoss Relay on Fast Bleed Assembly\n\nRoss Engineering\n\nEA12-NC-20-1-15-DI/BD\n\n2\n\n4160V Protective Relay (SEL)\n\nSchweitzer\n\n0787EX2B0X0X75850220/SEL-787\n\n2\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.355\n\n3\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.25\n\n3\n\n4160V Surge Arrestor Fuse\n\nSIBA\n\nFUHV-07K016/3000213.16\n\n3\n\nTransformer - Cooling Pump\n\nSiemens\n\nKT8050P\n\n2\n\nMotor Contactor Rebuild Kit - Cooling Pump\n\nSiemens\n\n75DF14\n\n2\n\nMotor Starter Overload Relay - Cooling Pump\n\nSiemens\n\n48ATC3S00\n\n2\n\nMotor Breaker\n\nSiemens\n\n3RV2011-1GA10\n\n2\n\nPower Contactors\n\nSiemens\n\n3RT2024-1BB40\n\n2\n\nThe proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.\n\nThis notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 22, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.\n\nContracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"W912P625RA014","place_of_performance":{"zip":"60441","city":{"code":"44225","name":"Lockport"},"state":{"code":"IL","name":"Illinois"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"5998"}],"due_at":"2025-09-22T20:30:00Z","due_date":"2025-09-22","closes_at":"2025-09-22T20:30:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","state":"IL","county":"17197","county_name":"Will County","city":"1744225","city_name":"Lockport","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-29T02:20:19.055385Z","principal_notice_id":"f360e539944e45aa9145f6798d9691af","description":{"text":"By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.\n\nThe Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary & Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:\n\nIGBT Module\n\nABB\n\n5SJA 3000L520300 (DUFI11)\n\n8\n\n4160V Surge Arrestor\n\nABB\n\n2GUS041500A110F\n\n1\n\nControlLogix Power Supply\n\nAllen Bradley\n\n1756-PA72\n\n2\n\nPLC Processor\n\nAllen Bradley\n\n1756-L71\n\n2\n\nControlLogix Ethernet/IP Communication Module\n\nAllen Bradley\n\n1756-EN2T\n\n2\n\nPLC Communication Module (Redundant)\n\nAllen Bradley\n\n1756-EN2TR\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB16\n\n2\n\nPLC AC Input Module\n\nAllen Bradley\n\n1756-IB16I\n\n2\n\nPLC DC Input Module\n\nAllen Bradley\n\n1756-IB32\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB16E\n\n2\n\nPLC DC Output Module\n\nAllen Bradley\n\n1756-OB32\n\n2\n\nPLC AC Output Module\n\nAllen Bradley\n\n1756-OA16\n\n2\n\nPLC Relay Output Module\n\nAllen Bradley\n\n1756-OW16I\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF16\n\n2\n\nPLC Analog Input Module\n\nAllen Bradley\n\n1756-IF8K\n\n2\n\nPLC RTD/TC/mV Module\n\nAllen Bradley\n\n1756-IRT8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF8I\n\n2\n\nPLC Analog Output Module\n\nAllen Bradley\n\n1756-OF4\n\n2\n\nMicroLogix Power Supply\n\nAllen Bradley\n\n1763-L16DWD\n\n2\n\nMicroLogix Analog Output Module\n\nAllen Bradley\n\n1762-OF4\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP1F\n\n2\n\nMedia Converter\n\nAllen Bradley\n\n1783-ETAP2F\n\n2\n\nTerminal Block Relay\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-TBR224\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36Z24\n\n10\n\nSlim Line Relay (Ice Cube Relay)\n\nAllen Bradley\n\n700-HK36A1\n\n10\n\nMaster Control Relay\n\nAllen Bradley\n\n700S-CF620EJC\n\n2\n\nLarge 8000 MicroFarad, 3000V, Capacitors\n\nAVX\n\nDKTFM961A8007\n\n7\n\nPulse/Delay Function Generator - 1N\n\nBNC\n\n9522-L82-IA15-COM-S-US/575 - 2 Channels\n\n1\n\nSurge Arrestor Power Resistor\n\nCarborundum\n\n888SP 75Ohm 10%P/M\n\n3\n\nCommunication Network Switch\n\nCISCO\n\nIE-3200-8T2S-E\n\n2\n\nManaged Switch, Rack Mounted\n\nCisco\n\nIE-4010-16S12P\n\n2\n\nPneumatic Control Valve\n\nClippard\n\nMME-44ZEEE-D024\n\n4\n\nManifold\n\nClippard\n\nMMM-44-02\n\n1\n\nManifold Mounting Hardware\n\nClippard\n\n27041-44\n\n1\n\nElectrical Noise Filter\n\nCORCOM\n\n20EQ1\n\n3\n\nThin Client\n\nDell\n\nWyse 5070\n\n2\n\n4160V HVPS Main Circuit Interruptor\n\nEaton\n\nType: 50 VCP-TR 40 Style - Option Number: 67A3092G64 - 40440601000540001000\n\n1\n\nPower Factor Correction Capacitor\n\nEnerLux\n\nMFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)\n\n2\n\nSCR Trigger Circuit Board\n\nEnerpro\n\nMVTB66STF7.2/PCS-4-94\n\n2\n\nSCR Regulator Circuit Board\n\nEnerpro\n\nISOVLCL2X/PCS-4-91\n\n2\n\nSCR Multiplex board\n\nEnerpro\n\n1202602XX201A/PCS-4-90-12-FO\n\n2\n\nHVPPS Pneumatic Cylinder\n\nFabco Air, Inc.\n\nHPS0021580\n\n2\n\nSCR Fuse\n\nFerraz Shawmut/ Merson?\n\nPC94UD17C14CTD/ FUS-C17C14TA\n\n24\n\nHMI Touchscreen Panel\n\nHope Industries\n\nHIS-ML23-STAD\n\n2\n\nBleed Resistors (Fast) Assembly\n\nHVR Advanced Power Components\n\nJ05PDA200K\n\n4\n\nGeneral Purpose Relay\n\nIDEC\n\nRH4B-UL\n\n10\n\nCap Bank Current Transformer\n\nLEM\n\nLF 1005-S/SP33\n\n16\n\nFiber Optic Patch Panel\n\nLeviton\n\n5WMNT-01C\n\n2\n\n1\" NPTM Flow Switch\n\nMcDonnell & Miller\n\nFS254\n\n2\n\nCooling Fan Blade\n\nMultiWing/Neeltran\n\n24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1 Neeltran part number)\n\n2\n\nCurrent Transducer\n\nOhio Semitronics Inc.\n\nCTLC-252SDT\n\n2\n\nCompact RTD Temperature Probe/Sensor\n\nOmega\n\nRTDM12-1/8NPT-3MM-24MM-A\n\n2\n\n1/4\" Stainless Steel Pressure Transducers\n\nOmega\n\nPX319-100G10V\n\n4\n\nOutput Isolation Diodes\n\nPoseico\n\nDAI-16C36C (Poseico P/N AR2009S36)\n\n40\n\nSCRs\n\nPoseico Power Electronics\n\nSCR-30C40C (Poseico P/N AT870S40)\n\n2\n\nSCRs\n\nPoseico Power Electronics\n\nAT1228S36/SCR-13C36C (Poseico P/N AT1228S32)\n\n24\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98006RFR2SW1P1\n\n4\n\n1/2\" Flow Meter/Sensor\n\nProteus\n\n98008RFR10SW1P1\n\n2\n\n1\" Flow Meter/Sensor\n\nProteus\n\n98016RFR60SW1P1\n\n2\n\nPulse/Delay Function Generator - 1S\n\nQuantum\n\n9520 - 2 Channels\n\n1\n\nCommunication Network Switch (Protocol Converter)\n\nRed Lion\n\nDSPLE000\n\n2\n\nRoss Relay on Fast Bleed Assembly\n\nRoss Engineering\n\nEA12-NC-20-1-15-DI/BD\n\n2\n\n4160V Protective Relay (SEL)\n\nSchweitzer\n\n0787EX2B0X0X75850220/SEL-787\n\n2\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.355\n\n3\n\nPF Correction Capacitor Fuse\n\nSIBA\n\n3010014.25\n\n3\n\n4160V Surge Arrestor Fuse\n\nSIBA\n\nFUHV-07K016/3000213.16\n\n3\n\nTransformer - Cooling Pump\n\nSiemens\n\nKT8050P\n\n2\n\nMotor Contactor Rebuild Kit - Cooling Pump\n\nSiemens\n\n75DF14\n\n2\n\nMotor Starter Overload Relay - Cooling Pump\n\nSiemens\n\n48ATC3S00\n\n2\n\nMotor Breaker\n\nSiemens\n\n3RV2011-1GA10\n\n2\n\nPower Contactors\n\nSiemens\n\n3RT2024-1BB40\n\n2\n\nThe proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.\n\nThis notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 22, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.\n\nContracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.","html":"<p>By way of this notice, and in accordance with FAR 6.302-1(c)(1), the Chicago District, U.S. Army Corps of Engineers announces its intention to award a Brand-Named contract for the components manufactured by the companies listed.</p>\n\n<p></p>\n\n<p>The Chicago District intends to establish a firm-fixed price supply contract for between USACE and Majestic Integrated Construction Solutions for brand name items for Electric Dispersal Barrier I installed on Chicago Sanitary &amp; Ship Canal (CSSC) near Romeoville, Illinois. Under the proposed contract, Majestic Integrated Construction Solutions will be required to provide the following:</p>\n\n<p></p>\n\n<p>IGBT Module</p>\n\n<p>ABB</p>\n\n<p>5SJA 3000L520300 (DUFI11)</p>\n\n<p>8</p>\n\n<p>4160V Surge Arrestor</p>\n\n<p>ABB</p>\n\n<p>2GUS041500A110F</p>\n\n<p>1</p>\n\n<p>ControlLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-PA72</p>\n\n<p>2</p>\n\n<p>PLC Processor</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-L71</p>\n\n<p>2</p>\n\n<p>ControlLogix Ethernet/IP Communication Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2T</p>\n\n<p>2</p>\n\n<p>PLC Communication Module (Redundant)</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-EN2TR</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16</p>\n\n<p>2</p>\n\n<p>PLC AC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB16I</p>\n\n<p>2</p>\n\n<p>PLC DC Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IB32</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB16E</p>\n\n<p>2</p>\n\n<p>PLC DC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OB32</p>\n\n<p>2</p>\n\n<p>PLC AC Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OA16</p>\n\n<p>2</p>\n\n<p>PLC Relay Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OW16I</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF16</p>\n\n<p>2</p>\n\n<p>PLC Analog Input Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IF8K</p>\n\n<p>2</p>\n\n<p>PLC RTD/TC/mV Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-IRT8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF8I</p>\n\n<p>2</p>\n\n<p>PLC Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1756-OF4</p>\n\n<p>2</p>\n\n<p>MicroLogix Power Supply</p>\n\n<p>Allen Bradley</p>\n\n<p>1763-L16DWD</p>\n\n<p>2</p>\n\n<p>MicroLogix Analog Output Module</p>\n\n<p>Allen Bradley</p>\n\n<p>1762-OF4</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP1F</p>\n\n<p>2</p>\n\n<p>Media Converter</p>\n\n<p>Allen Bradley</p>\n\n<p>1783-ETAP2F</p>\n\n<p>2</p>\n\n<p>Terminal Block Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-TBR224</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36Z24</p>\n\n<p>10</p>\n\n<p>Slim Line Relay (Ice Cube Relay)</p>\n\n<p>Allen Bradley</p>\n\n<p>700-HK36A1</p>\n\n<p>10</p>\n\n<p>Master Control Relay</p>\n\n<p>Allen Bradley</p>\n\n<p>700S-CF620EJC</p>\n\n<p>2</p>\n\n<p>Large 8000 MicroFarad, 3000V, Capacitors</p>\n\n<p>AVX</p>\n\n<p>DKTFM961A8007</p>\n\n<p>7</p>\n\n<p>Pulse/Delay Function Generator - 1N</p>\n\n<p>BNC</p>\n\n<p>9522-L82-IA15-COM-S-US/575 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Surge Arrestor Power Resistor</p>\n\n<p>Carborundum</p>\n\n<p>888SP 75Ohm 10%P/M</p>\n\n<p>3</p>\n\n<p>Communication Network Switch</p>\n\n<p>CISCO</p>\n\n<p>IE-3200-8T2S-E</p>\n\n<p>2</p>\n\n<p>Managed Switch, Rack Mounted</p>\n\n<p>Cisco</p>\n\n<p>IE-4010-16S12P</p>\n\n<p>2</p>\n\n<p>Pneumatic Control Valve</p>\n\n<p>Clippard</p>\n\n<p>MME-44ZEEE-D024</p>\n\n<p>4</p>\n\n<p>Manifold</p>\n\n<p>Clippard</p>\n\n<p>MMM-44-02</p>\n\n<p>1</p>\n\n<p>Manifold Mounting Hardware</p>\n\n<p>Clippard</p>\n\n<p>27041-44</p>\n\n<p>1</p>\n\n<p>Electrical Noise Filter</p>\n\n<p>CORCOM</p>\n\n<p>20EQ1</p>\n\n<p>3</p>\n\n<p>Thin Client</p>\n\n<p>Dell</p>\n\n<p>Wyse 5070</p>\n\n<p>2</p>\n\n<p>4160V HVPS Main Circuit Interruptor</p>\n\n<p>Eaton</p>\n\n<p>Type: 50 VCP-TR 40&nbsp;&nbsp;&nbsp;&nbsp; Style - Option Number: 67A3092G64 - 40440601000540001000</p>\n\n<p>1</p>\n\n<p>Power Factor Correction Capacitor</p>\n\n<p>EnerLux</p>\n\n<p>MFPI.4.2/333.60/00 (PFC-42C10C - Neeltran)</p>\n\n<p>2</p>\n\n<p>SCR Trigger Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>MVTB66STF7.2/PCS-4-94</p>\n\n<p>2</p>\n\n<p>SCR Regulator Circuit Board</p>\n\n<p>Enerpro</p>\n\n<p>ISOVLCL2X/PCS-4-91</p>\n\n<p>2</p>\n\n<p>SCR Multiplex board</p>\n\n<p>Enerpro</p>\n\n<p>1202602XX201A/PCS-4-90-12-FO</p>\n\n<p>2</p>\n\n<p>HVPPS Pneumatic Cylinder</p>\n\n<p>Fabco Air, Inc.</p>\n\n<p>HPS0021580</p>\n\n<p>2</p>\n\n<p>SCR Fuse</p>\n\n<p>Ferraz Shawmut/ Merson?</p>\n\n<p>PC94UD17C14CTD/ FUS-C17C14TA</p>\n\n<p>24</p>\n\n<p>HMI Touchscreen Panel</p>\n\n<p>Hope Industries</p>\n\n<p>HIS-ML23-STAD</p>\n\n<p>2</p>\n\n<p>Bleed Resistors (Fast) Assembly</p>\n\n<p>HVR Advanced Power Components</p>\n\n<p>J05PDA200K</p>\n\n<p>4</p>\n\n<p>General Purpose Relay</p>\n\n<p>IDEC</p>\n\n<p>RH4B-UL</p>\n\n<p>10</p>\n\n<p>Cap Bank Current Transformer</p>\n\n<p>LEM</p>\n\n<p>LF 1005-S/SP33</p>\n\n<p>16</p>\n\n<p>Fiber Optic Patch Panel</p>\n\n<p>Leviton</p>\n\n<p>5WMNT-01C</p>\n\n<p>2</p>\n\n<p>1&quot; NPTM Flow Switch</p>\n\n<p>McDonnell &amp; Miller</p>\n\n<p>FS254</p>\n\n<p>2</p>\n\n<p>Cooling Fan Blade</p>\n\n<p>MultiWing/Neeltran</p>\n\n<p>24.12/9-9/20/PPG/4ZR/SH.625/AS (FBAH-249625-1&nbsp;&nbsp; Neeltran part number)</p>\n\n<p>2</p>\n\n<p>Current Transducer</p>\n\n<p>Ohio Semitronics Inc.</p>\n\n<p>CTLC-252SDT</p>\n\n<p>2</p>\n\n<p>Compact RTD Temperature Probe/Sensor</p>\n\n<p>Omega</p>\n\n<p>RTDM12-1/8NPT-3MM-24MM-A</p>\n\n<p>2</p>\n\n<p>1/4&quot; Stainless Steel Pressure Transducers</p>\n\n<p>Omega</p>\n\n<p>&nbsp;PX319-100G10V</p>\n\n<p>4</p>\n\n<p>Output Isolation Diodes</p>\n\n<p>Poseico</p>\n\n<p>DAI-16C36C (Poseico P/N AR2009S36)</p>\n\n<p>40</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>SCR-30C40C (Poseico P/N AT870S40)</p>\n\n<p>2</p>\n\n<p>SCRs</p>\n\n<p>Poseico Power Electronics</p>\n\n<p>AT1228S36/SCR-13C36C (Poseico P/N AT1228S32)</p>\n\n<p>24</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98006RFR2SW1P1</p>\n\n<p>4</p>\n\n<p>1/2&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98008RFR10SW1P1</p>\n\n<p>2</p>\n\n<p>1&quot; Flow Meter/Sensor</p>\n\n<p>Proteus</p>\n\n<p>98016RFR60SW1P1</p>\n\n<p>2</p>\n\n<p>Pulse/Delay Function Generator - 1S</p>\n\n<p>Quantum</p>\n\n<p>9520 - 2 Channels</p>\n\n<p>1</p>\n\n<p>Communication Network Switch (Protocol Converter)</p>\n\n<p>Red Lion</p>\n\n<p>DSPLE000</p>\n\n<p>2</p>\n\n<p>Ross Relay on Fast Bleed Assembly</p>\n\n<p>Ross Engineering</p>\n\n<p>EA12-NC-20-1-15-DI/BD</p>\n\n<p>2</p>\n\n<p>4160V Protective Relay (SEL)</p>\n\n<p>Schweitzer</p>\n\n<p>0787EX2B0X0X75850220/SEL-787</p>\n\n<p>2</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.355</p>\n\n<p>3</p>\n\n<p>PF Correction Capacitor Fuse</p>\n\n<p>SIBA</p>\n\n<p>3010014.25</p>\n\n<p>3</p>\n\n<p>4160V Surge Arrestor Fuse</p>\n\n<p>SIBA</p>\n\n<p>FUHV-07K016/3000213.16</p>\n\n<p>3</p>\n\n<p>Transformer - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>KT8050P</p>\n\n<p>2</p>\n\n<p>Motor Contactor Rebuild Kit - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>75DF14</p>\n\n<p>2</p>\n\n<p>Motor Starter Overload Relay - Cooling Pump</p>\n\n<p>Siemens</p>\n\n<p>48ATC3S00</p>\n\n<p>2</p>\n\n<p>Motor Breaker</p>\n\n<p>Siemens</p>\n\n<p>3RV2011-1GA10</p>\n\n<p>2</p>\n\n<p>Power Contactors</p>\n\n<p>Siemens</p>\n\n<p>3RT2024-1BB40</p>\n\n<p>2</p>\n\n<p></p>\n\n<p>The proposed parts have been the only known components to be compatible with the highly specialized and custom-built electric fish barrier.</p>\n\n<p></p>\n\n<p>This notice does not constitute a solicitation for offers, proposals, etc. However, interested firms may send a capabilities statement NO LATER THAN 3:30p.m. (CDT) on September 22, 2025. Statements should be sent to the attention of Kyle Smith at kyle.d.smith@usace.army.mil. Please ensure that the subject line of your email includes the title/description of this announcement. Award is anticipated on or about September 30, 2025. This announcement is in accordance with FAR 5.101(a)(1). The point of contact is Kyle Smith at (312) 846-5368.</p>\n\n<p>Contracting Office Address: U.S. Army Corps of Engineers, Chicago District, 231 S. LaSalle Street, Suite 1500, Chicago, IL 60604-1437.</p>","origin":"detail"},"contacts":[{"name":"Kyle Smith","role":"primary","email":"kyle.d.smith@usace.army.mil","phone":"3128465370"}],"place_of_performance":{"zip":"60441","city":{"code":"44225","name":"Lockport"},"state":{"code":"IL","name":"Illinois"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"60604-1437","city":"CHICAGO","state":"IL","country":"USA"},"naics_codes":["335314"],"award":null,"attachments":[],"awards":[],"related":[{"key":"PANGLR26P0000029409","latest_notice_id":"92febb48cb0342b9ab57980edfd4d7dc","title":"Thomas J O???????????????????????????Brien Lock and Dam Major Rehabilitation ??????????????????????????? Construction, Chicago, Cook County, Illinois","solicitation_number":"PANGLR26P0000029409","notice_type":"r","first_type":"r","first_posted":"2026-10-27","last_posted":"2026-10-27","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","naics":"237990","psc":"Z2KA","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"UNITED STATES OF AMERICA, CHICAGO, COOK COUNTY, ILLINOIS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"W912P627MR027755","latest_notice_id":"5cc099a662c74ba1a59532a34d6f03e2","title":"Commercial Gear Backup Power (CGBP) and Control System Improvements at Fish Barrier","solicitation_number":"W912P627MR027755","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","naics":"238210","psc":"Z2MZ","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"ROMEOVILLE, IL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"W912P627X1CZ7","latest_notice_id":"d13db3ad548f4e1cb0a6bc7bef73a313","title":"MARKET SURVEY SOURCES SOUGHT NOTICE FOR BARRIER IIB ATS SYSTEMS REPLACEMENT","solicitation_number":"W912P627X1CZ7","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-07T20:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P6","office_name":"W072 ENDIST CHICAGO","naics":"238210","psc":"Z2BG","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"790 EAST OLD ROMEO RD LOCKPORT/ROMEOVILLE, IL 60441","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"SPE7M527T2925","latest_notice_id":"0cfd3efc5f93408899f3f5676b960973","title":"59--RELAY,ELECTROMAGNETIC","solicitation_number":"SPE7M527T2925","notice_type":"k","first_type":"k","first_posted":"2026-11-15","last_posted":"2026-11-15","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M5","office_name":"DLA WEAPONS SUPPORT","naics":"335314","psc":"59","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"ETIC: LINE 0001 QTY 102 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-16T05:16:26.996061Z"},{"key":"SPE7M227T0961","latest_notice_id":"761f1d081e60440785804ecb8077703c","title":"59--SWITCH,PRESSURE","solicitation_number":"SPE7M227T0961","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M2","office_name":"DLA WEAPONS SUPPORT","naics":"335314","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SURE: LINE 0001 QTY 24 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"SPE4A527T3748","latest_notice_id":"e63efc7d6f6741c183c1ea118bbaf102","title":"59--RELAY,ELECTROMAGNETIC","solicitation_number":"SPE4A527T3748","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A5","office_name":"DLA AVIATION","naics":"335314","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TIC: LINE 0001 QTY 29 UI EA DELIVER TO: DLA DISTRIBUTION DEPOT OKLAHOMA BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":81,"indexable":false}