Sources sought
Wolf Creek, Cordell Hull, & Old Hickory Power Plants: VCB Repair
W912p526TKDB4
Department of the Army, W072 Endist Nashville. Electrical Contractors and Other Wiring Installation Contractors.
Response deadline
June 24, 2026 at 2:00 PM EDT
Closed 154 days ago. Posted June 17, 2026. Scheduled to archive July 9, 2026.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2026
42 like it are open now in electrical contractors and other wiring installation contractors
- LEX Triannual Energy Study and ARC Flash Testing
Department of Veterans Affairs, 249-Network Contract Office 9
Combined synopsis and solicitationSDVOSBNAICS 238210Lexington-Fayette, KY36C24927Q0038_0001Closes in 8 daysDec 3 - LEX Triannual Energy Study and ARC Flash Testing
Department of Veterans Affairs, 249-Network Contract Office 9
Combined synopsis and solicitationSDVOSBNAICS 238210Lexington-Fayette, KY36C24927Q0038Closes in 370 daysNov 30, 2027 - INSTALLATION OF PROXIMITY SENSORS FOR AUTOMATIC DOORS
Department of Veterans Affairs, 246-Network Contracting Office 6
SolicitationNAICS 238210Ship to Fayetteville, NC36C24627Q0114Due todayNov 25
All 42 open in electrical contractors and other wiring installation contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238210 (electrical contractors and other wiring installation contractors), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation has been published under this number yet. The sources sought of June 17, 2026 is the earliest notice of the purchase.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
REQUEST FOR INFORMATION
The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.
This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Requirement: The work shall consist of furnishing all labor, tools, materials, and Eaton approved test equipment necessary to refurbish and deliver a total of three (3) total Eaton 150VCP-WG-50-3000A Vacuum Circuit Breakers (VCB), property of the US Government, to Cordell Hull, Wolf Creek, and Old Hickory respectively. The VCBs have been provided to Eaton for evaluation and recommended refurbishment. Following final refurbishment, the contractor shall return three (3) Eaton 150VCP-WG50-3000A VCB to Cordell Hull Power Plant, Wolf Creek Power Plant, and Old Hickory Power Plant as described below. The breaker must be compatible with existing USACE switchgear.
The contractor will be required to provide all plant, labor and materials to complete the project.
- PSC Z1MD Maintenance of EPG Facilities - Hydro NAICS 238210 Electrical Contractors and Other Wiring Installation Contractors, Size Standard $19M.
Survey: The Government is issuing this notice to determine a competitive basis. This is not a solicitation and the items listed herein are subject to change or eliminated from the requirement. This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Your response to this survey is requested by 1:00 PM Central Time Wednesday, June 24, 2026. Please send by email to Kerri Broglin at Kerri.D.Broglin@usace.army.mil
- Name of your firm:
- CAGE:
- Point of Contact, Phone number and EMAIL address:
- Are you a Certified Eaton Repair Facility:
- Please provide responses to the following:
1) List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience, as a prime contractor or subcontractor, constructing gantry cranes with capacities exceeding 100 tons.
(a) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(b) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(c) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
- Are you a Small Business classified under the above NAICS code? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)?
- If this requirement is advertised, do you anticipate submitting a quote?
Please provide any additional information you feel is necessary:
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 17, 2026
Sources sought
Due June 24, 2026 at 2:00 PM EDT. SAM.gov, notice f24e43cdbcdf4d348b7c83f9b465cb7b
1 revision on SAM
- June 17, 2026: publish, sources sought
Points of contact
- KERRI BROGLINkerri.d.broglin@usace.army.mil6157367130
- Alison Abernathyalison.t.abernathy@usace.army.mil