{"canonical":"https://sealedbidder.com/opportunities/w912p526qa023","key":"W912P526QA023","url":"https://sealedbidder.com/opportunities/w912p526qa023","title":"Barkley Emergency Gate Machinery Inspection","solicitation_number":"W912P526QA023","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-17T19:00:00Z","first_posted":"2026-06-10","last_posted":"2026-07-13","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W072 ENDIST NASHVILLE","naics":"811310","psc":"J039","set_aside":null,"place_state":"KY","place_scope":"site","site":null,"place_state_source":"sam_street","place_evidence":"BARKLEY LOCK, 758 BARKLEY DAM ROAD, GRAND RIVERS, KY, 42045","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"41e3406564a740fba4cbcf65d30af4b7","title":"Barkley Emergency Gate Machinery Inspection","solicitation_number":"W912P526QA023","notice_type":"k","base_type":"k","posted":"2026-06-10","posted_at":"2026-06-10T21:51:36.638Z","due_at":"2026-07-10T19:00:00Z","due_date":"2026-07-10","cancelled":false,"archived":false,"archive_date":"2027-06-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/41e3406564a740fba4cbcf65d30af4b7/view","enriched":true,"history":[{"index":2,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-13T14:16:59.987Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"6462e6e41b87497ca011a8cc0fbbe241","solicitation_number":"W912P526QA023","parent_opportunity_id":"41e3406564a740fba4cbcf65d30af4b7"},{"index":1,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T21:51:36.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"41e3406564a740fba4cbcf65d30af4b7","solicitation_number":"W912P526QA023"}]},{"notice_id":"6462e6e41b87497ca011a8cc0fbbe241","title":"Barkley Emergency Gate Machinery Inspection","solicitation_number":"W912P526QA023","notice_type":"k","base_type":"k","posted":"2026-07-13","posted_at":"2026-07-13T14:16:59.987Z","due_at":"2026-07-17T19:00:00Z","due_date":"2026-07-17","cancelled":null,"archived":null,"archive_date":"2027-07-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6462e6e41b87497ca011a8cc0fbbe241/view","enriched":true,"history":[{"index":2,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-13T14:16:59.987Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"6462e6e41b87497ca011a8cc0fbbe241","solicitation_number":"W912P526QA023","parent_opportunity_id":"41e3406564a740fba4cbcf65d30af4b7"},{"index":1,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T21:51:36.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"41e3406564a740fba4cbcf65d30af4b7","solicitation_number":"W912P526QA023"}]}],"latest_notice_id":"6462e6e41b87497ca011a8cc0fbbe241","first_type":"k","notices":[{"dates":{"posted":"2026-06-10","posted_at":"2026-06-10T21:51:36.638Z","created_at":"2026-06-10T21:51:36.580Z","modified_at":"2026-07-13T14:16:59.987Z","response_deadline":{"raw":"2026-07-10T14:00:00-05:00","utc":"2026-07-10T19:00:00Z","date":"2026-07-10","time":"14:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/41e3406564a740fba4cbcf65d30af4b7/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Barkley Emergency Gate Machinery Inspection","agency":{"office":{"code":"W912P5","name":"W072 ENDIST NASHVILLE"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"37203-1070","city":"NASHVILLE","state":"TN","country":"USA"},"organization_id":"100221376","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-06-10","archive_type":"auto_custom"},"history":[{"index":2,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-13T14:16:59.987Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"6462e6e41b87497ca011a8cc0fbbe241","solicitation_number":"W912P526QA023","parent_opportunity_id":"41e3406564a740fba4cbcf65d30af4b7"},{"index":1,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T21:51:36.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"41e3406564a740fba4cbcf65d30af4b7","solicitation_number":"W912P526QA023"}],"contacts":[{"name":"ROBERT ELLIS","role":"primary","email":"robert.s.ellis@usace.army.mil","phone":"6157365632"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"41e3406564a740fba4cbcf65d30af4b7","lineage_id":"41e3406564a740fba4cbcf65d30af4b7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T00:58:11.470082457Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"7cb2fae1cedc7de5dbbe953352c5f91052df481672bafe762d10860c587725d9","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T00:58:11.470082457Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","text":"Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912P526QA023","place_of_performance":{"zip":"42045","street":"Barkley Lock, 758 Barkley Dam Road, Grand Rivers, KY, 42045"},"product_service_code":"J039"},{"dates":{"posted":"2026-07-13","posted_at":"2026-07-13T14:16:59.987Z","created_at":"2026-07-13T14:16:59.197Z","modified_at":"2026-07-13T14:16:59.987Z","response_deadline":{"raw":"2026-07-17T14:00:00-05:00","utc":"2026-07-17T19:00:00Z","date":"2026-07-17","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6462e6e41b87497ca011a8cc0fbbe241/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Barkley Emergency Gate Machinery Inspection","agency":{"office":{"code":"W912P5","name":"W072 ENDIST NASHVILLE"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"37203-1070","city":"NASHVILLE","state":"TN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2027-07-13","archive_type":"auto_custom"},"history":[{"index":2,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-13T14:16:59.987Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"6462e6e41b87497ca011a8cc0fbbe241","solicitation_number":"W912P526QA023","parent_opportunity_id":"41e3406564a740fba4cbcf65d30af4b7"},{"index":1,"title":"Barkley Emergency Gate Machinery Inspection","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T21:51:36.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"41e3406564a740fba4cbcf65d30af4b7","solicitation_number":"W912P526QA023"}],"contacts":[{"name":"ROBERT ELLIS","role":"primary","email":"robert.s.ellis@usace.army.mil","phone":"6157365632"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"6462e6e41b87497ca011a8cc0fbbe241","lineage_id":"41e3406564a740fba4cbcf65d30af4b7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:05:16.316444766Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"369617ded40cbb1a5684d899a1676d9511c2d6b0aa90d9c66d1eb4ea0f413946","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"Amendment 0001 - The due date for receipt of quotes is extended to 17 July 2026 at 1400 Central Time. Additionally, answers to questions received are being posted. Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","text":"Amendment 0001 - The due date for receipt of quotes is extended to 17 July 2026 at 1400 Central Time. Additionally, answers to questions received are being posted. Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912P526QA023","place_of_performance":{"zip":"42045","street":"Barkley Lock, 758 Barkley Dam Road, Grand Rivers, KY, 42045"},"product_service_code":"J039"}],"due_at":"2026-07-17T19:00:00Z","due_date":"2026-07-17","closes_at":"2026-07-17T19:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P5","office_name":"W072 ENDIST NASHVILLE","state":"KY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"BARKLEY LOCK, 758 BARKLEY DAM ROAD, GRAND RIVERS, KY, 42045","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-02T08:44:04.547541Z","principal_notice_id":"6462e6e41b87497ca011a8cc0fbbe241","description":{"text":"Amendment 0001 - The due date for receipt of quotes is extended to 17 July 2026 at 1400 Central Time. Additionally, answers to questions received are being posted. Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","html":"Amendment 0001 - The due date for receipt of quotes is extended to 17 July 2026 at 1400 Central Time. Additionally, answers to questions received are being posted. Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.","origin":"detail"},"contacts":[{"name":"ROBERT ELLIS","role":"primary","email":"robert.s.ellis@usace.army.mil","phone":"6157365632"}],"place_of_performance":{"zip":"42045","street":"Barkley Lock, 758 Barkley Dam Road, Grand Rivers, KY, 42045"},"office_address":{"zip":"37203-1070","city":"NASHVILLE","state":"TN","country":"USA"},"naics_codes":["811310"],"award":null,"attachments":[{"resource_id":"d9172247a6cc495a8ced031fcb647883","name":"dodprocurementtoolbox.com","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-06-10T21:51:36.638Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false}],"awards":[],"related":[{"key":"W912P527QA001","latest_notice_id":"a886367d738e43aca34f52ad64c95a47","title":"Supply and Deliver DC and AC Preferred Systems for USACE-LRN","solicitation_number":"W912P527QA001","notice_type":"k","first_type":"k","first_posted":"2026-10-19","last_posted":"2026-11-12","notices":8,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P5","office_name":"W072 ENDIST NASHVILLE","naics":"335313","psc":"6110","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6110)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"W912P527RAXXX","latest_notice_id":"9dd28dc222ea4d64ac1f6baed66dc3c9","title":"WOLF CREEK POWERHOUSE BRIDGE CRANE REHABILITATION","solicitation_number":"W912P527RAXXX","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912P5","office_name":"W072 ENDIST NASHVILLE","naics":"333923","psc":"3950","set_aside":null,"state":"KY","county":"21207","county_name":"Russell County","city":"2140114","city_name":"Jamestown","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"W519TC27T3011","latest_notice_id":"c721288d703c4938b84585932a66b381","title":"Blanket Purchase Agreement (BPA) for CNC Machine Repair, Parts, Programming, and Training Services Blue Grass Army Depot (BGAD)","solicitation_number":"W519TC27T3011","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-03T18:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"811310","psc":"J034","set_aside":"SBA","state":"KY","county":"21151","county_name":"Madison County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Blue Grass Army Depot","site_key":"blue-grass-army-depot-ky","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"70Z02727RFQ000010","latest_notice_id":"d442a8374a9f40518aefb30b4adc715a","title":"USCG IPD Cape May Crane Repairs","solicitation_number":"70Z02727RFQ000010","notice_type":"o","first_type":"o","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"811310","psc":"J039","set_aside":"SBA","state":"NJ","county":"34009","county_name":"Cape May County","city":"3410270","city_name":"Cape May","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":57,"indexable":false}