Sources sought
Rapid Response Requirement for a 50kw propane-fueled generator set
W912HN25C00SM
Department of the Army, W074 Endist Savannah. Motor and Generator Manufacturing.
Response deadline
October 4, 2024 at 12:00 PM EDT
Closed 783 days ago. Posted October 3, 2024, first published October 2, 2024. Scheduled to archive October 19, 2024.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2024
71 like it are open now in motor and generator manufacturing
- Motor, Control
Department of the Army, W6QK ACC-RSA
SolicitationNAICS 335312Ship to Fort Bliss, TXW31P4Q27RA007Due todayNov 26 - MOTOR,ALTERNATING C
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 335312Ship to the buyerN0010427QLA15Due tomorrowNov 27 - CONDITIONER,POWER L
Defense Logistics Agency, Sprmm1 DLA Mechanicsburg
SolicitationNAICS 335312Ship to the buyerSPRMM127QKA05Due tomorrowNov 27
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 335312 (motor and generator manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of October 2, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
We would like to know who can perform this work and how soon we can have delivery, removal and installation. See attached DRAFT Statement of Work for Request for Information (RFI) Purposes ONLY. The Contractor shall replace the existing 50 kW diesel generator, diesel fuel tank and automatic transfer switch (ATS) with a new generator, new fuel tank and ATS. The existing generator set, fuel tank and ATS located in the Lock Operations Building shall be demolished, removed and disposed of by the Contractor.
The existing diesel fuel tank is located on the first floor of the Lock Operations Building behind a chain-link fence.The existing generator set and ATS are located on the second level of the Lock Operations Building. A new propane-fueled generator set, propane fuel tank and ATS shall be provided and installed on the land-side pavilion between the Lock Operations Building and the public parking area. The new generator, fuel tank and ATS shall be located on a new elevated equipment pad constructed adjacent to the existing service transformer.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Shermaine MaloneShermaine.D.Malone@usace.army.mil9126525165
- Nathan Aylesworthnathan.a.aylesworth@usace.army.mil9126525384