Sources sought
Renovate Bldg. 59D -Robins AFB, GA
W912HN-25-B-4002
Department of the Army, W074 Endist Savannah. Commercial and Institutional Building Construction.
Response deadline
February 28, 2025 at 3:00 PM EST
Closed 636 days ago. Posted February 10, 2025. Scheduled to archive March 15, 2025.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2025
191 like it are open now in commercial and institutional building construction
- Building 262 Renovation, FLETC Glynco, Georgia
Federal Law Enforcement Training Center, FLETC Glynco Procurement Office
SolicitationSmall businessNAICS 236220Georgia70LGLY27RSSB00001Due in 6 daysDec 2 - FY27 NRM - EHRM Base 509-22-701 - EHRM Infrastructure Upgrades - Downtown Division - Construction (VA-27-00011175)
Department of Veterans Affairs, Pcac
Sources soughtNAICS 236220Augusta-Richmond County, GA36C77627Q0075Due in 7 daysDec 3 - Robins RAPID Construction OTA Umbrella Notice
Department of the Air Force, FA8501 Opl Contracting Afsc/Pzio
Closes in 370 daysDec 1, 2027
All 191 open in commercial and institutional building construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of February 10, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
1. The US Army Corps of Engineers (USACE), Savannah District, is conducting market research to identify potential parties having interest in and capability of performing construction specialty trade services to renovate/repair building 59D and replace damage fire control system in building 62 at Robins AFB, GA.
Based on the responses to this source sought notice/market research, this requirement may be set-aside for small business (in full or in part) or procured through full and open competition. All Small Business Set-Aside categories will be considered. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluation will be provided to companies regarding their submissions. The Government will consider feedback received in determining if a small business set-aside is appropriate for this when it issues the solicitation package anticipated early 4th quarter with an award this fiscal year.
DISCLAIMER: This sources sought is for information purposes only; it is not a request for competitive proposals, quotations, or bids. It does not constitute a solicitation and shall not be construed as a commitment by the Government. Responses in any form are not offers and the Government is under no obligation to award a contract as a result of this announcement. No Funds are available to pay for preparation of responses to this announcement. Any information submitted by respondents to the announcement is strictly voluntary and will not be returned to the responder. Incomplete answers in any section, failure to provide required or incomplete documents, or providing information outside the scope of this announcement may remove respondents from the Government’s determination of whether to solicit reference project on a set-aside basis in accordance with Part 19 of the Federal Acquisition Regulation. Not responding to this notice does not preclude participation in any future request for competitive proposals, quotations, or bids, if any issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry (GPE). It is the responsibility of potential offerors to monitor the GPE for additional information pertaining to this requirement.
2. The applicable NAICS code for this requirement is 236220 – Commercial and Institutional Building Construction with a Small Business Size Standard of $45M. Businesses of all sizes are encouraged to respond; however, each respondent must clearly identify their business size in their capabilities statement.
3. Construction Magnitude: The estimated magnitude of this construction project is between $25,000,000 and $100,000,000. (DFARS 236.204).
4. Project Description: The work includes the repair/renovate of approximately 142,202 square feet (13,211 square meters) of the existing dry de-paint process to a chemical process in building 59. The paint processes will occur simultaneously in both building 59D and building 59P. In building 59D, work shall consist of, but not be limited to: Replace concrete dock floor and trench drain system. Repair roof vibration issues from the exhaust fans. Repair dust filtration system, central plant system, chillers, cooling towers, pumps, fans, motors, outside air handling units and associated piping, fire alarm and fire sprinkler systems, security lighting, communication support, roofing system, chemical pre-treatment system, and electrical systems. Clean residual paint dusts. Provide cybersecurity for the facility related HVAC control system.
Additionally, all work necessary to replace the damaged fire control system in building 62 will be completed. Work shall consist of, but not be limited to, replacing the fire protection pumps (including the jockey pump), motors, controllers, isolation valves (including tamper switches), transformer, and GFCI outlets. The pumps will be connected back to the existing piping and the motors, controllers, transformer, and GFCI outlets will be connected to the existing electrical power connections. New water lines will be installed to provide cooling water for the packing on the pumps. An existing 4-inch pipe will be rerouted to provide better access to the equipment. Install industrial lift station and associated piping.
5. The estimated period of performance for construction is 540 calendar days after issuance of the Notice to Proceed. Specifics regarding the number of option periods, if any, will be provided in the solicitation.
6. All interested parties, with 236220 as an approved NAICS code, are requested to provide a capability package limited to no more than five (5) pages (excluding Market Survey). All responses under this Sources Sought Notice must be emailed to Contract Specialist, Alicia Scott at alicia.d.scott@usace.army.mil and cc the Contracting Officer, Gregory Graham at gregory.m.graham@usace.army.mil no later than February 28, 2025 at 3:00pm Eastern Standard Time. Responses must include identification and verification of the company's business size status, a completed Market Survey Questionnaire, and a capability package, which is provided as an attachment to this announcement.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Sources Sought-Market Survey - Renovate 59D_ Robins AFB GA .docx28 KB, February 10, 2025
- Sources Sought-Market Survey - Renovate 59D_ Robins AFB GA .pdf152 KB, February 10, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 10, 2025
Sources sought
Due February 28, 2025 at 3:00 PM EST. SAM.gov, notice 5624e2ec253f4583b0e583a2efe8b1b8
1 revision on SAM
- February 10, 2025: publish, sources sought
Points of contact
- Gregory Grahamgregory.m.graham@usace.army.mil9126525476
- Alicia Scottalicia.d.scott@usace.army.mil9125255005