{"canonical":"https://sealedbidder.com/opportunities/w912es26qa013","key":"W912ES26QA013","url":"https://sealedbidder.com/opportunities/w912es26qa013","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-02-13T16:00:00Z","first_posted":"2025-12-02","last_posted":"2026-04-20","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W07V ENDIST ST PAUL","naics":"541380","psc":"H256","set_aside":"SBA","place_state":"WI","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"55011","place_county_name":"Buffalo County","place_city":"5526850","place_city_name":"Fountain City","winner":"MISTRAS GROUP INC","award_amount":"1500000.00","publications":[{"notice_id":"370e081b429f44be9641b42ea387595a","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"p","base_type":"p","posted":"2025-12-02","posted_at":"2025-12-02T13:40:42.442Z","due_at":"2025-12-25T06:01:00Z","due_date":"2025-12-25","cancelled":false,"archived":true,"archive_date":"2026-01-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/370e081b429f44be9641b42ea387595a/view","enriched":true,"history":[{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]},{"notice_id":"07bc741ff35c459484bd197800406bad","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"o","base_type":"p","posted":"2026-01-07","posted_at":"2026-01-07T15:29:52.898Z","due_at":"2026-02-06T16:00:00Z","due_date":"2026-02-06","cancelled":false,"archived":true,"archive_date":"2026-02-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/07bc741ff35c459484bd197800406bad/view","enriched":true,"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]},{"notice_id":"cad96d540cf54c7c8b1738c6f199c437","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"o","base_type":"o","posted":"2026-01-07","posted_at":"2026-01-07T18:43:27.193Z","due_at":"2026-02-06T16:00:00Z","due_date":"2026-02-06","cancelled":false,"archived":true,"archive_date":"2026-02-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cad96d540cf54c7c8b1738c6f199c437/view","enriched":true,"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]},{"notice_id":"03262c54268243ad822bdb0aa8dd45f5","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"o","base_type":"o","posted":"2026-01-14","posted_at":"2026-01-14T18:04:50.500Z","due_at":"2026-02-06T16:00:00Z","due_date":"2026-02-06","cancelled":false,"archived":true,"archive_date":"2026-02-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/03262c54268243ad822bdb0aa8dd45f5/view","enriched":true,"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]},{"notice_id":"ce706aca036c4cf5afab4ac862039b11","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26QA013","notice_type":"o","base_type":"o","posted":"2026-02-04","posted_at":"2026-02-04T16:27:26.092Z","due_at":"2026-02-13T16:00:00Z","due_date":"2026-02-13","cancelled":false,"archived":true,"archive_date":"2026-02-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ce706aca036c4cf5afab4ac862039b11/view","enriched":true,"history":[{"index":11,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T17:50:35.836Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"6233e5731fb94d73afe640d62571313e","solicitation_number":"W912ES26DA003","related_opportunity_id":"ce706aca036c4cf5afab4ac862039b11"},{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":5,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]},{"notice_id":"6233e5731fb94d73afe640d62571313e","title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","solicitation_number":"W912ES26DA003","notice_type":"a","base_type":"o","posted":"2026-04-20","posted_at":"2026-04-20T17:50:35.836Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-05-01","removed_at":null,"award_number":"W912ES26DA003","awardee_name":"MISTRAS GROUP INC","amount":"1500000.00","link_sam":"https://sam.gov/workspace/contract/opp/6233e5731fb94d73afe640d62571313e/view","enriched":true,"history":[{"index":5,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T17:50:35.836Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"6233e5731fb94d73afe640d62571313e","solicitation_number":"W912ES26DA003","related_opportunity_id":"ce706aca036c4cf5afab4ac862039b11"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}]}],"latest_notice_id":"6233e5731fb94d73afe640d62571313e","first_type":"p","notices":[{"dates":{"posted":"2025-12-02","posted_at":"2025-12-02T13:40:42.442Z","created_at":"2025-12-02T13:37:44.361Z","modified_at":"2026-01-10T04:55:44.534Z","response_deadline":{"raw":"2025-12-25T00:01:00-06:00","utc":"2025-12-25T06:01:00Z","date":"2025-12-25","time":"00:01:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/370e081b429f44be9641b42ea387595a/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-09","archive_type":"auto15"},"history":[{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"370e081b429f44be9641b42ea387595a","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-20T03:21:26.019158232Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"ebf709cf3d69b9e66406419ae6bd514f29a1081ac88ba1d3d97db72b53dc09d3","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-20T03:21:26.019158232Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"<p>The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.&nbsp;</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>Johnson Machine Works</li>\n</ul>\n\n<p>48899 Hy Vee Rd</p>\n\n<p>Chariton, IA 50049</p>\n\n<ul>\n\t<li>Lock and Dam 5A</li>\n</ul>\n\n<p>W679 WI-35</p>\n\n<p>Fountain City, WI 54629</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>G&amp;G Steel Inc</li>\n</ul>\n\n<p>15825 AL-243</p>\n\n<p>Russellville, AL 35653<u> </u></p>\n\n<ul>\n\t<li>Warrior River Steel LLC</li>\n</ul>\n\n<p>6275 Horsecreek Blvd</p>\n\n<p>Cordova, AL 35550</p>\n\n<p></p>\n\n<p>Required services include work associated with the following LD5A RGM and LD3&amp;4 MGR activities: QA Inspection and Verification of Construction Contractor&rsquo;s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor&rsquo;s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.&nbsp;</p>\n\n<p></p>\n\n<p>It is anticipated that this project will be solicited mid to late December 2025. &nbsp;All dates are tentative and for planning purposes only.&nbsp;</p>\n\n<p></p>\n\n<p>The North American Industry Classification System (NAICS) code for this project will be 541380; Testing Laboratories and Services with a size standard of $19.0 Million.</p>\n\n<p></p>\n\n<p>The resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.</p>\n\n<p></p>\n\n<p>The solicitation shall be set-aside for Small Business.</p>\n\n<p><br />\nThe solicitation will be a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.</p>\n\n<p></p>\n\n<p>This synopsis is not a request for quotes, proposals, or bids. This is a notice that a solicitation for a competitive acquisition for the award of one firm-fixed price contract is intended to be issued via Contract Opportunities (https://sam.gov/content/opportunities) in the near future. The specifications will be detailed in the solicitation. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract.</p>\n\n<p></p>\n\n<p>This is a pre-solicitation notice, and as such, any additional information as to the size and/or scope of the project will not be available until the issuance of the RFP.</p>\n\n<p></p>\n\n<p>No CD&#39;s or hard copies of this notice or the solicitation will be available. Offerors are responsible for checking the above listed Contract Opportunities website for any update(s) to the Notice.&nbsp; The Government is not responsible for any loss of Internet connectivity or for an offeror&#39;s inability to access the document posted at the referenced website.</p>\n\n<p></p>\n\n<p>In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.</p>\n\n<p></p>","text":"The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.\n\nQA services for the LD5A will be required at the following locations:\n\n• Johnson Machine Works\n\n48899 Hy Vee Rd\n\nChariton, IA 50049\n\n• Lock and Dam 5A\n\nW679 WI-35\n\nFountain City, WI 54629\n\nQA services for the LD5A will be required at the following locations:\n\n• G&G Steel Inc\n\n15825 AL-243\n\nRussellville, AL 35653\n\n• Warrior River Steel LLC\n\n6275 Horsecreek Blvd\n\nCordova, AL 35550\n\nRequired services include work associated with the following LD5A RGM and LD3&4 MGR activities: QA Inspection and Verification of Construction Contractor’s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor’s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.\n\nIt is anticipated that this project will be solicited mid to late December 2025. All dates are tentative and for planning purposes only.\n\nThe North American Industry Classification System (NAICS) code for this project will be 541380; Testing Laboratories and Services with a size standard of $19.0 Million.\n\nThe resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.\n\nThe solicitation shall be set-aside for Small Business.\n\nThe solicitation will be a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.\n\nThis synopsis is not a request for quotes, proposals, or bids. This is a notice that a solicitation for a competitive acquisition for the award of one firm-fixed price contract is intended to be issued via Contract Opportunities (https://sam.gov/content/opportunities) in the near future. The specifications will be detailed in the solicitation. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract.\n\nThis is a pre-solicitation notice, and as such, any additional information as to the size and/or scope of the project will not be available until the issuance of the RFP.\n\nNo CD's or hard copies of this notice or the solicitation will be available. Offerors are responsible for checking the above listed Contract Opportunities website for any update(s) to the Notice. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the document posted at the referenced website.\n\nIn order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W912ES26QA013","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"},{"dates":{"posted":"2026-01-07","posted_at":"2026-01-07T15:29:52.898Z","created_at":"2026-01-07T15:26:52.770Z","modified_at":"2026-02-28T05:13:14.827Z","response_deadline":{"raw":"2026-02-06T10:00:00-06:00","utc":"2026-02-06T16:00:00Z","date":"2026-02-06","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/07bc741ff35c459484bd197800406bad/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-21","archive_type":"auto15"},"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"07bc741ff35c459484bd197800406bad","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-17T02:06:07.219246209Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"2d133cebb804352691cdd7020d590aef91daa906874b3266dc07a0950d7dd660","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-17T02:06:07.219246209Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.&nbsp;</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>Johnson Machine Works</li>\n</ul>\n\n<p>48899 Hy Vee Rd</p>\n\n<p>Chariton, IA 50049</p>\n\n<ul>\n\t<li>Lock and Dam 5A</li>\n</ul>\n\n<p>W679 WI-35</p>\n\n<p>Fountain City, WI 54629</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>G&amp;G Steel Inc</li>\n</ul>\n\n<p>15825 AL-243</p>\n\n<p>Russellville, AL 35653<u> </u></p>\n\n<ul>\n\t<li>Warrior River Steel LLC</li>\n</ul>\n\n<p>6275 Horsecreek Blvd</p>\n\n<p>Cordova, AL 35550</p>\n\n<p></p>\n\n<p>Required services include work associated with the following LD5A RGM and LD3&amp;4 MGR activities: QA Inspection and Verification of Construction Contractor&rsquo;s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor&rsquo;s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.&nbsp;</p>\n\n<p></p>\n\n<p>The North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.</p>\n\n<p></p>\n\n<p>The resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.</p>\n\n<p></p>\n\n<p>The solicitation is set-aside for Small Business.</p>\n\n<p><br />\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.</p>\n\n<p></p>\n\n<p>No CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation.&nbsp; The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.</p>\n\n<p></p>\n\n<p>There is no &ldquo;Plan Holder List&rdquo; for this project.&nbsp; The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website.&nbsp; In order to view this list, vendors will need to sign into their SAM account.</p>\n\n<p></p>\n\n<p>In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.</p>\n\n<p></p>\n\n<p>As required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.</p>","text":"The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.\n\nQA services for the LD5A will be required at the following locations:\n\n• Johnson Machine Works\n\n48899 Hy Vee Rd\n\nChariton, IA 50049\n\n• Lock and Dam 5A\n\nW679 WI-35\n\nFountain City, WI 54629\n\nQA services for the LD5A will be required at the following locations:\n\n• G&G Steel Inc\n\n15825 AL-243\n\nRussellville, AL 35653\n\n• Warrior River Steel LLC\n\n6275 Horsecreek Blvd\n\nCordova, AL 35550\n\nRequired services include work associated with the following LD5A RGM and LD3&4 MGR activities: QA Inspection and Verification of Construction Contractor’s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor’s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.\n\nThe North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.\n\nThe resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.\n\nThe solicitation is set-aside for Small Business.\n\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.\n\nNo CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.\n\nThere is no “Plan Holder List” for this project. The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website. In order to view this list, vendors will need to sign into their SAM account.\n\nIn order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.\n\nAs required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912ES26QA013","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"},{"dates":{"posted":"2026-01-07","posted_at":"2026-01-07T18:43:27.193Z","created_at":"2026-01-07T18:40:02.887Z","modified_at":"2026-02-28T05:13:14.827Z","response_deadline":{"raw":"2026-02-06T10:00:00-06:00","utc":"2026-02-06T16:00:00Z","date":"2026-02-06","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cad96d540cf54c7c8b1738c6f199c437/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-21","archive_type":"auto15"},"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"cad96d540cf54c7c8b1738c6f199c437","lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-17T02:34:58.805122241Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3c13a5b1d0eeca7f9c2aaf555c642e000e8970bafcf6c0542d99052a256c520b","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-17T02:34:58.805122241Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).</p>\n\n<p>The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.&nbsp;</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>Johnson Machine Works</li>\n</ul>\n\n<p>48899 Hy Vee Rd</p>\n\n<p>Chariton, IA 50049</p>\n\n<ul>\n\t<li>Lock and Dam 5A</li>\n</ul>\n\n<p>W679 WI-35</p>\n\n<p>Fountain City, WI 54629</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>G&amp;G Steel Inc</li>\n</ul>\n\n<p>15825 AL-243</p>\n\n<p>Russellville, AL 35653<u> </u></p>\n\n<ul>\n\t<li>Warrior River Steel LLC</li>\n</ul>\n\n<p>6275 Horsecreek Blvd</p>\n\n<p>Cordova, AL 35550</p>\n\n<p></p>\n\n<p>Required services include work associated with the following LD5A RGM and LD3&amp;4 MGR activities: QA Inspection and Verification of Construction Contractor&rsquo;s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor&rsquo;s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.&nbsp;</p>\n\n<p></p>\n\n<p>The North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.</p>\n\n<p></p>\n\n<p>The resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.</p>\n\n<p></p>\n\n<p>The solicitation is Full and Open (Unrestricted).</p>\n\n<p><br />\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.</p>\n\n<p></p>\n\n<p>No CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation.&nbsp; The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.</p>\n\n<p></p>\n\n<p>There is no &ldquo;Plan Holder List&rdquo; for this project.&nbsp; The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website.&nbsp; In order to view this list, vendors will need to sign into their SAM account.</p>\n\n<p></p>\n\n<p>In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.</p>\n\n<p></p>\n\n<p>As required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.</p>","text":"***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).\n\nThe U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.\n\nQA services for the LD5A will be required at the following locations:\n\n• Johnson Machine Works\n\n48899 Hy Vee Rd\n\nChariton, IA 50049\n\n• Lock and Dam 5A\n\nW679 WI-35\n\nFountain City, WI 54629\n\nQA services for the LD5A will be required at the following locations:\n\n• G&G Steel Inc\n\n15825 AL-243\n\nRussellville, AL 35653\n\n• Warrior River Steel LLC\n\n6275 Horsecreek Blvd\n\nCordova, AL 35550\n\nRequired services include work associated with the following LD5A RGM and LD3&4 MGR activities: QA Inspection and Verification of Construction Contractor’s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor’s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.\n\nThe North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.\n\nThe resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.\n\nThe solicitation is Full and Open (Unrestricted).\n\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.\n\nNo CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.\n\nThere is no “Plan Holder List” for this project. The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website. In order to view this list, vendors will need to sign into their SAM account.\n\nIn order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.\n\nAs required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912ES26QA013","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"},{"dates":{"posted":"2026-01-14","posted_at":"2026-01-14T18:04:50.500Z","created_at":"2026-01-14T18:01:04.945Z","modified_at":"2026-02-28T05:13:14.827Z","response_deadline":{"raw":"2026-02-06T10:00:00-06:00","utc":"2026-02-06T16:00:00Z","date":"2026-02-06","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/03262c54268243ad822bdb0aa8dd45f5/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-21","archive_type":"auto15"},"history":[{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":4,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"03262c54268243ad822bdb0aa8dd45f5","lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-16T01:41:41.574711659Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"8f1026199bb4331683e7370f856ad828e629f32d9b4e823b4e1e1a5e2e6c5af4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-16T01:41:41.574711659Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>***Amendment 0001 removes and replaces the Schedule of Services.</p>\n\n<p>***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).</p>\n\n<p>The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.&nbsp;</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>Johnson Machine Works</li>\n</ul>\n\n<p>48899 Hy Vee Rd</p>\n\n<p>Chariton, IA 50049</p>\n\n<ul>\n\t<li>Lock and Dam 5A</li>\n</ul>\n\n<p>W679 WI-35</p>\n\n<p>Fountain City, WI 54629</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>G&amp;G Steel Inc</li>\n</ul>\n\n<p>15825 AL-243</p>\n\n<p>Russellville, AL 35653<u> </u></p>\n\n<ul>\n\t<li>Warrior River Steel LLC</li>\n</ul>\n\n<p>6275 Horsecreek Blvd</p>\n\n<p>Cordova, AL 35550</p>\n\n<p></p>\n\n<p>Required services include work associated with the following LD5A RGM and LD3&amp;4 MGR activities: QA Inspection and Verification of Construction Contractor&rsquo;s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor&rsquo;s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.&nbsp;</p>\n\n<p></p>\n\n<p>The North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.</p>\n\n<p></p>\n\n<p>The resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.</p>\n\n<p></p>\n\n<p>The solicitation is Full and Open (Unrestricted).</p>\n\n<p><br />\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.</p>\n\n<p></p>\n\n<p>No CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation.&nbsp; The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.</p>\n\n<p></p>\n\n<p>There is no &ldquo;Plan Holder List&rdquo; for this project.&nbsp; The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website.&nbsp; In order to view this list, vendors will need to sign into their SAM account.</p>\n\n<p></p>\n\n<p>In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.</p>\n\n<p></p>\n\n<p>As required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.</p>","text":"***Amendment 0001 removes and replaces the Schedule of Services.\n\n***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).\n\nThe U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.\n\nQA services for the LD5A will be required at the following locations:\n\n• Johnson Machine Works\n\n48899 Hy Vee Rd\n\nChariton, IA 50049\n\n• Lock and Dam 5A\n\nW679 WI-35\n\nFountain City, WI 54629\n\nQA services for the LD5A will be required at the following locations:\n\n• G&G Steel Inc\n\n15825 AL-243\n\nRussellville, AL 35653\n\n• Warrior River Steel LLC\n\n6275 Horsecreek Blvd\n\nCordova, AL 35550\n\nRequired services include work associated with the following LD5A RGM and LD3&4 MGR activities: QA Inspection and Verification of Construction Contractor’s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor’s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.\n\nThe North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.\n\nThe resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.\n\nThe solicitation is Full and Open (Unrestricted).\n\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.\n\nNo CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.\n\nThere is no “Plan Holder List” for this project. The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website. In order to view this list, vendors will need to sign into their SAM account.\n\nIn order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.\n\nAs required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912ES26QA013","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"},{"dates":{"posted":"2026-02-04","posted_at":"2026-02-04T16:27:26.092Z","created_at":"2026-02-04T16:23:56.765Z","modified_at":"2026-02-28T05:13:14.827Z","response_deadline":{"raw":"2026-02-13T10:00:00-06:00","utc":"2026-02-13T16:00:00Z","date":"2026-02-13","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ce706aca036c4cf5afab4ac862039b11/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-28","archive_type":"auto15"},"history":[{"index":11,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T17:50:35.836Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"6233e5731fb94d73afe640d62571313e","solicitation_number":"W912ES26DA003","related_opportunity_id":"ce706aca036c4cf5afab4ac862039b11"},{"index":8,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":6,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-14T18:04:50.500Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"03262c54268243ad822bdb0aa8dd45f5","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":5,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-02T13:40:42.442Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"370e081b429f44be9641b42ea387595a","solicitation_number":"W912ES26QA013"},{"index":3,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T18:43:27.193Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cad96d540cf54c7c8b1738c6f199c437","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-07T15:29:52.898Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"07bc741ff35c459484bd197800406bad","solicitation_number":"W912ES26QA013","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ce706aca036c4cf5afab4ac862039b11","lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-14T03:36:14.246176303Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"c977ce218486e0dbad2ee6314d88f4b3f640a1b4562eec26910b5e8e8c5395d5","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-14T03:36:14.246176303Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>***Amendment 0002 removes and replaces the Scope of Work (SOW), makes changes to the Basis for Award, and extends the solicitation closing date.</p>\n\n<p>***Amendment 0001 removes and replaces the Schedule of Services.</p>\n\n<p>***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).</p>\n\n<p>The U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.&nbsp;</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>Johnson Machine Works</li>\n</ul>\n\n<p>48899 Hy Vee Rd</p>\n\n<p>Chariton, IA 50049</p>\n\n<ul>\n\t<li>Lock and Dam 5A</li>\n</ul>\n\n<p>W679 WI-35</p>\n\n<p>Fountain City, WI 54629</p>\n\n<p></p>\n\n<p>QA services for the LD5A will be required at the following locations:</p>\n\n<ul>\n\t<li>G&amp;G Steel Inc</li>\n</ul>\n\n<p>15825 AL-243</p>\n\n<p>Russellville, AL 35653<u> </u></p>\n\n<ul>\n\t<li>Warrior River Steel LLC</li>\n</ul>\n\n<p>6275 Horsecreek Blvd</p>\n\n<p>Cordova, AL 35550</p>\n\n<p></p>\n\n<p>Required services include work associated with the following LD5A RGM and LD3&amp;4 MGR activities: QA Inspection and Verification of Construction Contractor&rsquo;s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor&rsquo;s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.&nbsp;</p>\n\n<p></p>\n\n<p>The North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.</p>\n\n<p></p>\n\n<p>The resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.</p>\n\n<p></p>\n\n<p>The solicitation is Full and Open (Unrestricted).</p>\n\n<p><br />\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.</p>\n\n<p></p>\n\n<p>No CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation.&nbsp; The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.</p>\n\n<p></p>\n\n<p>There is no &ldquo;Plan Holder List&rdquo; for this project.&nbsp; The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website.&nbsp; In order to view this list, vendors will need to sign into their SAM account.</p>\n\n<p></p>\n\n<p>In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.</p>\n\n<p></p>\n\n<p>As required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.</p>","text":"***Amendment 0002 removes and replaces the Scope of Work (SOW), makes changes to the Basis for Award, and extends the solicitation closing date.\n\n***Amendment 0001 removes and replaces the Schedule of Services.\n\n***This solicitation notice was inadvertently posted as a small business set-aside and has been corrected to Full and Open (Unrestricted).\n\nThe U.S. Army Corps of Engineers (USACE), St. Paul District has a requirement for a contractor capable of providing Quality Assurance (QA) Inspection services for the Lock and Dam (LD) No. 5A Routine Gate Maintenance project and the LD 3 and 4 Miter Gate Fabrication Contract.\n\nQA services for the LD5A will be required at the following locations:\n\n• Johnson Machine Works\n\n48899 Hy Vee Rd\n\nChariton, IA 50049\n\n• Lock and Dam 5A\n\nW679 WI-35\n\nFountain City, WI 54629\n\nQA services for the LD5A will be required at the following locations:\n\n• G&G Steel Inc\n\n15825 AL-243\n\nRussellville, AL 35653\n\n• Warrior River Steel LLC\n\n6275 Horsecreek Blvd\n\nCordova, AL 35550\n\nRequired services include work associated with the following LD5A RGM and LD3&4 MGR activities: QA Inspection and Verification of Construction Contractor’s inspections; QA testing and inspection of steel repairs; QA testing and inspection of steel fabrication; QA inspections of Construction Contractor’s Painting Means and Methods; QA inspections of coatings; and Review and Response to applicable requests for information (RFI) and submittals.\n\nThe North American Industry Classification System (NAICS) code for this project is 541380; Testing Laboratories and Services with a size standard of $19.0 Million.\n\nThe resulting contract shall be a Firm, Fixed-Price Indefinite Delivery, Indefinite Quantity (IDIQ) contract with a base year period of performance and four (4) option years.\n\nThe solicitation is Full and Open (Unrestricted).\n\nThe solicitation is a request for quote (RFQ) and will be evaluated using Lowest Price, Technically Acceptable (LPTA) evaluations in accordance with FAR 15.101-2.\n\nNo CDs or hard copies of the solicitation will be available. Offerors are responsible for checking the Contract Opportunities website (https://sam.gov/content/opportunities) for any update(s) to the solicitation. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the document posted at the referenced website.\n\nThere is no “Plan Holder List” for this project. The interested vendors list is listed as part of the solicitation posting on the Contract Opportunities website. In order to view this list, vendors will need to sign into their SAM account.\n\nIn order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management (SAM). All Offerors must be registered in SAM prior to receiving an award, have an active SAM account, and have the Representations and Certifications (FAR and DFARS) sections completed prior to award. Registration instructions may be obtained, and online registration may be accomplished, at https://sam.gov/content/entity-landing.\n\nAs required by 15 U.S.C. 644(w), the Corps of Engineers policy and procedures, as well as past performance information, in regard to definitization of requests for equitable adjustments is found at https://www.usace.army.mil/Business-With-Us/Partnering.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912ES26QA013","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"},{"award":{"date":"2026-04-16","amount":"1500000.00","number":"W912ES26DA003","awardee":{"raw":"MISTRAS GROUP INC Princeton Junction NJ 08550 USA","uei":"GH1DGHNNHS58","cage":"5YY84","name":"MISTRAS GROUP INC","location":{"zip":"08550","city":{"code":"60960","name":"Princeton Junction"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-04-20","posted_at":"2026-04-20T17:50:35.836Z","award_date":"2026-04-16","created_at":"2026-04-20T17:48:32.651Z","modified_at":"2026-05-02T03:55:43.471Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/6233e5731fb94d73afe640d62571313e/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-01","archive_type":"auto15"},"history":[{"index":5,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T17:50:35.836Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"6233e5731fb94d73afe640d62571313e","solicitation_number":"W912ES26DA003","related_opportunity_id":"ce706aca036c4cf5afab4ac862039b11"},{"index":2,"title":"Lock and Dam (LD) 5A Routine Gate Maintenance Quality Assurance and LD 3&4 Gate Fabrication Quality Assurance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-04T16:27:26.092Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ce706aca036c4cf5afab4ac862039b11","solicitation_number":"W912ES26QA013","parent_opportunity_id":"07bc741ff35c459484bd197800406bad","related_opportunity_id":"370e081b429f44be9641b42ea387595a"}],"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"6233e5731fb94d73afe640d62571313e","lineage_id":"07bc741ff35c459484bd197800406bad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T09:07:21.862158147Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"d14ebb30f6cc084d633e4abb4b689ccb587607f0696e4a7d824178be02dbefc9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T09:07:21.862158147Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Posting of award notice</p>","text":"Posting of award notice","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"W912ES26DA003","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H256"}],"due_at":"2026-02-13T16:00:00Z","due_date":"2026-02-13","closes_at":"2026-02-13T16:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","state":"WI","county":"55011","county_name":"Buffalo County","city":"5526850","city_name":"Fountain City","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"GH1DGHNNHS58","amount":"1500000.00","linked_awards":6,"cancelled":false,"archived":true,"updated_at":"2026-10-06T09:17:53.526399Z","principal_notice_id":"6233e5731fb94d73afe640d62571313e","description":{"text":"Posting of award notice","html":"<p>Posting of award notice</p>","origin":"detail"},"contacts":[{"name":"Scott E. Hendrix","role":"primary","email":"Scott.E.Hendrix@usace.army.mil"},{"name":"Kenneth Eshom","role":"secondary","email":"kenneth.j.eshom@usace.army.mil"}],"place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"naics_codes":["541380"],"award":{"date":"2026-04-16","amount":"1500000.00","number":"W912ES26DA003","awardee":{"raw":"MISTRAS GROUP INC Princeton Junction NJ 08550 USA","uei":"GH1DGHNNHS58","cage":"5YY84","name":"MISTRAS GROUP INC","location":{"zip":"08550","city":{"code":"60960","name":"Princeton Junction"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"74ab608e673441d1a8cd3c2def0d3116","name":"WD 2015-4613 Rev 31 dtd 12-03-2025 Alabama - Russellville.docx","kind":"file","mime_type":".docx","size_bytes":37993,"posted_at":"2026-01-07T15:29:52.898Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/74ab608e673441d1a8cd3c2def0d3116/download","mirrored":false}],"awards":[{"award_key":"CONT_IDV_W912ES26DA003_9700","permalink":"https://www.usaspending.gov/award/CONT_IDV_W912ES26DA003_9700/","piid":"W912ES26DA003","parent_piid":null,"award_type":null,"vendor_key":"GH1DGHNNHS58","recipient_name":"MISTRAS GROUP INC","recipient_uei":"GH1DGHNNHS58","recipient_cage":"5YY84","recipient_city":"PRINCETON JUNCTION","recipient_state":"NJ","sub_name":"Department of the Army","office_name":"W07V ENDIST ST PAUL","office_key":"o-W912ES","first_action_date":"2026-04-16","last_action_date":"2026-05-20","actions":2,"obligated":"0","current_total_value":null,"potential_total_value":"1500000.00","naics":"541380","psc":"H256","extent_competed":"FULL AND OPEN COMPETITION","set_aside":"NO SET ASIDE USED.","offers_received":5,"description":"QUALITY ASSURANCE SERVICES FOR THE LOCK AND DAM 5A ROUTINE GATE MAINTENANCE CONSTRUCTION CONTRACT AND THE LOCK AND DAM 3 AND 4 MITER GATE FABRICATION CONTRACT.","method":"piid","confidence":"high","evidence":["award number W912ES26DA003 equals the contract number","same awarding office W912ES"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"693C7327Q000004","latest_notice_id":"9dd2ece47adb4e79b70690263779de18","title":"FY27 AASHTO ACCREDITATION AND INSPECTION SERVICES","solicitation_number":"693C7327Q000004","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-069","dept_name":"TRANSPORTATION, DEPARTMENT OF","sub_key":"s-6925","sub_name":"FEDERAL HIGHWAY ADMINISTRATION","office_key":"o-693C73","office_name":"693C73 EASTERN FED LANDS DIVISION","naics":"541380","psc":"H339","set_aside":null,"state":"TN","county":"47155","county_name":"Sevier County","city":"4767120","city_name":"Sevierville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open_total":34,"indexable":false}