{"canonical":"https://sealedbidder.com/opportunities/w912es25qa006","key":"W912ES25QA006","url":"https://sealedbidder.com/opportunities/w912es25qa006","title":"Electric Motor Winding & Vibration Analysis","solicitation_number":"W912ES25QA006","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-07T23:00:00Z","first_posted":"2025-02-28","last_posted":"2025-04-03","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W07V ENDIST ST PAUL","naics":"811310","psc":"H959","set_aside":"SBA","place_state":"WI","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"55011","place_county_name":"Buffalo County","place_city":"5526850","place_city_name":"Fountain City","winner":"USA GOVERNMENT CONTRACTING LLC","award_amount":"112000.00","publications":[{"notice_id":"ce19524ab7c24ffab722aa94166f54cf","title":"Electric Motor Winding & Vibration Analysis","solicitation_number":"W912ES25QA006","notice_type":"k","base_type":"k","posted":"2025-02-28","posted_at":"2025-02-28T20:35:15.639Z","due_at":"2025-03-07T23:00:00Z","due_date":"2025-03-07","cancelled":false,"archived":true,"archive_date":"2025-03-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ce19524ab7c24ffab722aa94166f54cf/view","enriched":true,"history":[{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}]},{"notice_id":"8d4f75df46e44e0b82015d4b566381eb","title":"Electric Motor Winding & Vibration Analysis","solicitation_number":"W912ES25QA006","notice_type":"k","base_type":"k","posted":"2025-03-05","posted_at":"2025-03-05T21:09:50.896Z","due_at":"2025-03-07T23:00:00Z","due_date":"2025-03-07","cancelled":false,"archived":true,"archive_date":"2025-03-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8d4f75df46e44e0b82015d4b566381eb/view","enriched":true,"history":[{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}]},{"notice_id":"9d0bc347a5844176ac916cf2de65eced","title":"Electric Motor Winding & Vibration Analysis","solicitation_number":"W912ES25QA006","notice_type":"k","base_type":"k","posted":"2025-03-06","posted_at":"2025-03-06T21:44:41.984Z","due_at":"2025-03-07T23:00:00Z","due_date":"2025-03-07","cancelled":false,"archived":true,"archive_date":"2025-03-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9d0bc347a5844176ac916cf2de65eced/view","enriched":true,"history":[{"index":6,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T11:55:33.215Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"94ca9181ec76475c94942bd12669fe3d","solicitation_number":"W912ES25PA003","related_opportunity_id":"9d0bc347a5844176ac916cf2de65eced"},{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}]},{"notice_id":"94ca9181ec76475c94942bd12669fe3d","title":"Electric Motor Winding & Vibration Analysis","solicitation_number":"W912ES25PA003","notice_type":"a","base_type":"k","posted":"2025-04-03","posted_at":"2025-04-03T11:55:33.215Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2025-04-17","removed_at":null,"award_number":"W912ES25PA003","awardee_name":"USA GOVERNMENT CONTRACTING LLC","amount":"112000.00","link_sam":"https://sam.gov/workspace/contract/opp/94ca9181ec76475c94942bd12669fe3d/view","enriched":true,"history":[{"index":5,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T11:55:33.215Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"94ca9181ec76475c94942bd12669fe3d","solicitation_number":"W912ES25PA003","related_opportunity_id":"9d0bc347a5844176ac916cf2de65eced"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"}]}],"latest_notice_id":"94ca9181ec76475c94942bd12669fe3d","first_type":"k","notices":[{"dates":{"posted":"2025-02-28","posted_at":"2025-02-28T20:35:15.639Z","created_at":"2025-02-28T20:26:31.993Z","modified_at":"2025-03-23T04:00:05.047Z","response_deadline":{"raw":"2025-03-07T17:00:00-06:00","utc":"2025-03-07T23:00:00Z","date":"2025-03-07","time":"17:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ce19524ab7c24ffab722aa94166f54cf/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Electric Motor Winding & Vibration Analysis","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-22","archive_type":"auto15"},"history":[{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}],"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Kevin P. Henricks","role":"secondary","email":"kevin.p.henricks@usace.army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"ce19524ab7c24ffab722aa94166f54cf","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ce19524ab7c24ffab722aa94166f54cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T10:55:49.680696891Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"556e54fa081cfbf0e915138319557c4ced22ab2063ed03e6faa062136867c7b3","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T10:55:49.680696891Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>SUBJECT: Scope of Work/Technical Specifications</p>\n\n<p>Winding and Vibration Analysis with Multiyear Option</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>General Information.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>Fountain City Service Base&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis Service Base</p>\n\n<p>431 N Shore Dr&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 100 Arsenal St</p>\n\n<p>Fountain City, WI 54629&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis, MO 63118</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for bearing vibration analysis will occur during dredging operations.&nbsp; This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next.&nbsp; Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are required to have the proper PPE when entering cabinets and MCC panels.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The Corps of Engineers reserves the right to inspect the equipment at any time.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Testing result notes will cover any problems with each motor tested and written recommendations.&nbsp; At no time is any repair work permitted unless approved from the contracting officer.&nbsp; Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"SUBJECT: Scope of Work/Technical Specifications\n\nWinding and Vibration Analysis with Multiyear Option\n\n• General Information.\n\n•\n\n• The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.\n\n•\n\n• Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\n• See Solicitation\n\n•\n\n• Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.\n\nFountain City Service Base St Louis Service Base\n\n431 N Shore Dr 100 Arsenal St\n\nFountain City, WI 54629 St Louis, MO 63118\n\n•\n\n• Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\n• See Solicitation\n\n•\n\n• Testing locations for bearing vibration analysis will occur during dredging operations. This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.\n\n•\n\n• Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.\n\n•\n\n• Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next. Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.\n\n•\n\n• Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.\n\n•\n\n• Contractors are required to have the proper PPE when entering cabinets and MCC panels.\n\n•\n\n• Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.\n\n•\n\n• A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.\n\n•\n\n• The Corps of Engineers reserves the right to inspect the equipment at any time.\n\n•\n\n• The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.\n\n• Testing result notes will cover any problems with each motor tested and written recommendations. At no time is any repair work permitted unless approved from the contracting officer. Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES25QA006","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H959"},{"dates":{"posted":"2025-03-05","posted_at":"2025-03-05T21:09:50.896Z","created_at":"2025-03-05T21:07:50.745Z","modified_at":"2025-03-23T04:00:05.047Z","response_deadline":{"raw":"2025-03-07T17:00:00-06:00","utc":"2025-03-07T23:00:00Z","date":"2025-03-07","time":"17:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8d4f75df46e44e0b82015d4b566381eb/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Electric Motor Winding & Vibration Analysis","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-22","archive_type":"auto15"},"history":[{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}],"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Kevin P. Henricks","role":"secondary","email":"kevin.p.henricks@usace.army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"8d4f75df46e44e0b82015d4b566381eb","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ce19524ab7c24ffab722aa94166f54cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T03:14:10.185345911Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"c855aadacdea702fa319301d2f07c0f93582b82a310e4baf8f9419f4a45a2c26","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T03:14:10.185345911Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>SUBJECT: Scope of Work/Technical Specifications</p>\n\n<p>Winding and Vibration Analysis with Multiyear Option</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>General Information.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>Fountain City Service Base&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis Service Base</p>\n\n<p>431 N Shore Dr&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 100 Arsenal St</p>\n\n<p>Fountain City, WI 54629&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis, MO 63118</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for bearing vibration analysis will occur during dredging operations.&nbsp; This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next.&nbsp; Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are required to have the proper PPE when entering cabinets and MCC panels.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The Corps of Engineers reserves the right to inspect the equipment at any time.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Testing result notes will cover any problems with each motor tested and written recommendations.&nbsp; At no time is any repair work permitted unless approved from the contracting officer.&nbsp; Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"SUBJECT: Scope of Work/Technical Specifications\n\nWinding and Vibration Analysis with Multiyear Option\n\n• General Information.\n\n•\n\n• The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.\n\n•\n\n• Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\n• See Solicitation\n\n•\n\n• Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.\n\nFountain City Service Base St Louis Service Base\n\n431 N Shore Dr 100 Arsenal St\n\nFountain City, WI 54629 St Louis, MO 63118\n\n•\n\n• Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\n• See Solicitation\n\n•\n\n• Testing locations for bearing vibration analysis will occur during dredging operations. This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.\n\n•\n\n• Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.\n\n•\n\n• Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next. Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.\n\n•\n\n• Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.\n\n•\n\n• Contractors are required to have the proper PPE when entering cabinets and MCC panels.\n\n•\n\n• Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.\n\n•\n\n• A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.\n\n•\n\n• The Corps of Engineers reserves the right to inspect the equipment at any time.\n\n•\n\n• The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.\n\n• Testing result notes will cover any problems with each motor tested and written recommendations. At no time is any repair work permitted unless approved from the contracting officer. Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES25QA006","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H959"},{"dates":{"posted":"2025-03-06","posted_at":"2025-03-06T21:44:41.984Z","created_at":"2025-03-06T21:42:52.002Z","modified_at":"2025-03-23T04:00:05.047Z","response_deadline":{"raw":"2025-03-07T17:00:00-06:00","utc":"2025-03-07T23:00:00Z","date":"2025-03-07","time":"17:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9d0bc347a5844176ac916cf2de65eced/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Electric Motor Winding & Vibration Analysis","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-22","archive_type":"auto15"},"history":[{"index":6,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T11:55:33.215Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"94ca9181ec76475c94942bd12669fe3d","solicitation_number":"W912ES25PA003","related_opportunity_id":"9d0bc347a5844176ac916cf2de65eced"},{"index":4,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-05T21:09:50.896Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"8d4f75df46e44e0b82015d4b566381eb","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"},{"index":1,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T20:35:15.639Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"ce19524ab7c24ffab722aa94166f54cf","solicitation_number":"W912ES25QA006"}],"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Kevin P. Henricks","role":"secondary","email":"kevin.p.henricks@usace.army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"9d0bc347a5844176ac916cf2de65eced","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ce19524ab7c24ffab722aa94166f54cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T02:35:15.740901914Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"0b931aead54d0b5e5e1e493ae47e8e582d86d65402c153857143bef810539825","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T02:35:15.740901914Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>SUBJECT: Scope of Work/Technical Specifications</p>\n\n<p>Winding and Vibration Analysis with Multiyear Option</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>General Information.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>Fountain City Service Base&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis Service Base</p>\n\n<p>431 N Shore Dr&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 100 Arsenal St</p>\n\n<p>Fountain City, WI 54629&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis, MO 63118</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for bearing vibration analysis will occur during dredging operations.&nbsp; This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next.&nbsp; Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are required to have the proper PPE when entering cabinets and MCC panels.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The Corps of Engineers reserves the right to inspect the equipment at any time.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Testing result notes will cover any problems with each motor tested and written recommendations.&nbsp; At no time is any repair work permitted unless approved from the contracting officer.&nbsp; Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","text":"SUBJECT: Scope of Work/Technical Specifications\n\nWinding and Vibration Analysis with Multiyear Option\n\n• General Information.\n\n•\n\n• The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.\n\n•\n\n• Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\n• See Solicitation\n\n•\n\n• Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.\n\nFountain City Service Base St Louis Service Base\n\n431 N Shore Dr 100 Arsenal St\n\nFountain City, WI 54629 St Louis, MO 63118\n\n•\n\n• Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\n• See Solicitation\n\n•\n\n• Testing locations for bearing vibration analysis will occur during dredging operations. This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.\n\n•\n\n• Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.\n\n•\n\n• Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next. Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.\n\n•\n\n• Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.\n\n•\n\n• Contractors are required to have the proper PPE when entering cabinets and MCC panels.\n\n•\n\n• Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.\n\n•\n\n• A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.\n\n•\n\n• The Corps of Engineers reserves the right to inspect the equipment at any time.\n\n•\n\n• The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.\n\n• Testing result notes will cover any problems with each motor tested and written recommendations. At no time is any repair work permitted unless approved from the contracting officer. Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES25QA006","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H959"},{"award":{"date":"2025-04-02","amount":"112000.00","number":"W912ES25PA003","awardee":{"raw":"USA GOVERNMENT CONTRACTING LLC Washington DC 20024 USA","uei":"UVWXEKPCBET1","cage":"9QM86","name":"USA GOVERNMENT CONTRACTING LLC","location":{"zip":"20024","city":{"name":"Washington"},"state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2025-04-03","posted_at":"2025-04-03T11:55:33.215Z","award_date":"2025-04-02","created_at":"2025-04-03T11:52:06.114Z","modified_at":"2025-04-18T03:55:49.012Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/94ca9181ec76475c94942bd12669fe3d/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"Electric Motor Winding & Vibration Analysis","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_id":"100221313","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-17","archive_type":"auto15"},"history":[{"index":5,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T11:55:33.215Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"94ca9181ec76475c94942bd12669fe3d","solicitation_number":"W912ES25PA003","related_opportunity_id":"9d0bc347a5844176ac916cf2de65eced"},{"index":2,"title":"Electric Motor Winding & Vibration Analysis","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-06T21:44:41.984Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9d0bc347a5844176ac916cf2de65eced","solicitation_number":"W912ES25QA006","parent_opportunity_id":"ce19524ab7c24ffab722aa94166f54cf"}],"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Kevin P. Henricks","role":"secondary","email":"kevin.p.henricks@usace.army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"94ca9181ec76475c94942bd12669fe3d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ce19524ab7c24ffab722aa94166f54cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T03:52:57.912920741Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"74febc138deb6ff04a2874bf3af13e5039e72735f34b5df56e47f4ab012ab915","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T03:52:57.912920741Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"W912ES25PA003","place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H959"}],"due_at":"2025-03-07T23:00:00Z","due_date":"2025-03-07","closes_at":"2025-03-07T23:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","state":"WI","county":"55011","county_name":"Buffalo County","city":"5526850","city_name":"Fountain City","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"UVWXEKPCBET1","amount":"112000.00","linked_awards":4,"cancelled":false,"archived":true,"updated_at":"2026-11-19T04:12:52.367518Z","principal_notice_id":"9d0bc347a5844176ac916cf2de65eced","description":{"text":"SUBJECT: Scope of Work/Technical Specifications\n\nWinding and Vibration Analysis with Multiyear Option\n\n• General Information.\n\n•\n\n• The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.\n\n•\n\n• Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\n• See Solicitation\n\n•\n\n• Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.\n\nFountain City Service Base St Louis Service Base\n\n431 N Shore Dr 100 Arsenal St\n\nFountain City, WI 54629 St Louis, MO 63118\n\n•\n\n• Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\n• See Solicitation\n\n•\n\n• Testing locations for bearing vibration analysis will occur during dredging operations. This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.\n\n•\n\n• Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.\n\n•\n\n• Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next. Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.\n\n•\n\n• Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.\n\n•\n\n• Contractors are required to have the proper PPE when entering cabinets and MCC panels.\n\n•\n\n• Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.\n\n•\n\n• A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.\n\n•\n\n• The Corps of Engineers reserves the right to inspect the equipment at any time.\n\n•\n\n• The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.\n\n• Testing result notes will cover any problems with each motor tested and written recommendations. At no time is any repair work permitted unless approved from the contracting officer. Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.","html":"<p>SUBJECT: Scope of Work/Technical Specifications</p>\n\n<p>Winding and Vibration Analysis with Multiyear Option</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>General Information.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The intent of this scope is to solicit quotes with multiyear options for winding analysis of multiple electrical motors and vibration analysis in the Dredge Goetz fleet.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for winding analysis is listed below. Testing will be completed between March 15th and April 11th of the base year and February 1st and March 30th of option years.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for winding analysis will occur at the following locations depending on where the Goetz fleet is located for winter maintenance. The base year will be at the Fountain City Service Base.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p>Fountain City Service Base&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis Service Base</p>\n\n<p>431 N Shore Dr&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 100 Arsenal St</p>\n\n<p>Fountain City, WI 54629&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; St Louis, MO 63118</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Equipment requiring testing for bearing vibration analysis is listed below. Testing will be completed between May 1st and June 30th of every year.\n\t\t<ol>\n\t\t\t<li>See Solicitation</li>\n\t\t</ol>\n\t\t</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Testing locations for bearing vibration analysis will occur during dredging operations.&nbsp; This analysis will take place on the Mississippi river system between Reeds Landing, MN and down to Lansing, IA.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors will be required to wear life vests while traveling to the vessel from the landing and while boarding the vessel. Hardhats are required, protective eyewear, and hi-visibility vests are required when onboard the vessel inside the enclosure.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Successful quoter will require the recording of all motor data plate information by the contractor to accurately track motor performance from one year to the next.&nbsp; Every year, data plate information will be checked to capture any equipment changes that can occur during the dredging season.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for powering down all equipment and locking out electrical systems in accordance with all local, state, and federal safety guidelines.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are required to have the proper PPE when entering cabinets and MCC panels.&nbsp;</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>Contractors are responsible for isolating equipment being tested from other A/C drives, capacitors, suppressors, lighting arrestors, grounding arrestors, or any other equipment that may cause improper winding analysis readings.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>A US Army Corps of Engineers (USACE) employee will be available the entire time to assist with removing covers, identifying equipment, or motor connections.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The Corps of Engineers reserves the right to inspect the equipment at any time.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li>The only work authorized is identified in this Statement of Work (SOW). Any additional repairs identified during the testing must be approved by the contracting office and are required to have prior written approval from the Contracting Office before the work begins.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>Testing result notes will cover any problems with each motor tested and written recommendations.&nbsp; At no time is any repair work permitted unless approved from the contracting officer.&nbsp; Results will be discussed with the USACE representative, and copies of the results will be submitted to the contracting office.</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Kevin P. Henricks","role":"secondary","email":"kevin.p.henricks@usace.army.mil"}],"place_of_performance":{"zip":"54629","city":{"code":"26850","name":"Fountain City"},"state":{"code":"WI","name":"Wisconsin"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"naics_codes":["811310"],"award":null,"attachments":[{"resource_id":"89de13bea73749019c7a0a6abf03fea6","name":"Wage Determination Wisconsin.pdf","kind":"file","mime_type":".pdf","size_bytes":5028909,"posted_at":"2025-02-28T20:35:15.639Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/89de13bea73749019c7a0a6abf03fea6/download","mirrored":false},{"resource_id":"6d2ac1c7ad88486fa1799b75450cb36b","name":"Wage Determination Missouri.pdf","kind":"file","mime_type":".pdf","size_bytes":5034293,"posted_at":"2025-02-28T20:35:15.639Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6d2ac1c7ad88486fa1799b75450cb36b/download","mirrored":false},{"resource_id":"5ff89dfe601842f9acb8f5d2756bb1f0","name":"SOW Photos Attachment.pdf","kind":"file","mime_type":".pdf","size_bytes":3778289,"posted_at":"2025-02-28T20:35:15.639Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5ff89dfe601842f9acb8f5d2756bb1f0/download","mirrored":false},{"resource_id":"6dba511732824a3d985d72d089ad2cb4","name":"Solicitation - W912ES25QA006.pdf","kind":"file","mime_type":".pdf","size_bytes":2706583,"posted_at":"2025-02-28T20:35:15.639Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6dba511732824a3d985d72d089ad2cb4/download","mirrored":false},{"resource_id":"c8e1dddee30048319e561c691e8337c9","name":"Solicitation Amendment W912ES25QA0060001 SF 30.pdf","kind":"file","mime_type":".pdf","size_bytes":3401027,"posted_at":"2025-03-05T21:09:50.896Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c8e1dddee30048319e561c691e8337c9/download","mirrored":false},{"resource_id":"982727596f51432e997125b65e3fae11","name":"Solicitation Amendment W912ES25QA0060002 SF 30.pdf","kind":"file","mime_type":".pdf","size_bytes":3420945,"posted_at":"2025-03-06T21:44:41.984Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/982727596f51432e997125b65e3fae11/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_W912ES25PA003_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W912ES25PA003_9700_-NONE-_-NONE-/","piid":"W912ES25PA003","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"UVWXEKPCBET1","recipient_name":"USA GOVERNMENT CONTRACTING LLC","recipient_uei":"UVWXEKPCBET1","recipient_cage":"9QM86","recipient_city":"WASHINGTON","recipient_state":"DC","sub_name":"Department of the Army","office_name":"W07V ENDIST ST PAUL","office_key":"o-W912ES","first_action_date":"2025-04-02","last_action_date":"2025-12-22","actions":2,"obligated":"44800.00","current_total_value":"44800.00","potential_total_value":"112000.00","naics":"811310","psc":"H959","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":3,"description":"THE U.S. ARMY CORPS OF ENGINEERS DREDGE GOETZ, FOUNTAIN CITY SERVICE BASE, HAS A REQUIREMENT FOR WINDING ANALYSIS OF MULTIPLE ELECTRICAL MOTORS AND VIBRATION ANALYSIS IN THE DREDGE GOETZ FLEET.","method":"piid","confidence":"high","evidence":["award number W912ES25PA003 equals the contract number","same awarding office W912ES"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"W5S09H27QA991","latest_notice_id":"efaa424bb3d24a1da82a195cf50d8d10","title":"FIRE EXTINGUISHER INSPECTION, MAINTENANCE, RECHARGE, REPAIR, HYDROSTATIC TESTING","solicitation_number":"W5S09H27QA991","notice_type":"k","first_type":"k","first_posted":"2026-11-02","last_posted":"2026-11-24","notices":5,"due_at":"2026-12-02T19:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S9H","office_name":"W7N8 USPFO ACTIVITY WIANG CRTC","naics":"811310","psc":"J012","set_aside":null,"state":"WI","county":"55057","county_name":"Juneau County","city":"5512350","city_name":"Camp Douglas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25627Q0131","latest_notice_id":"c34b2da547fb4d8fb1ceaf2fb177c660","title":"J012--Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service","solicitation_number":"36C25627Q0131","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"811310","psc":"J012","set_aside":null,"state":"AR","county":"05119","county_name":"Pulaski County","city":"0550450","city_name":"North Little Rock","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"70Z02727RFQ000010","latest_notice_id":"d442a8374a9f40518aefb30b4adc715a","title":"USCG IPD Cape May Crane Repairs","solicitation_number":"70Z02727RFQ000010","notice_type":"o","first_type":"o","first_posted":"2026-11-02","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"811310","psc":"J039","set_aside":"SBA","state":"NJ","county":"34009","county_name":"Cape May County","city":"3410270","city_name":"Cape May","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":58,"indexable":false}