{"canonical":"https://sealedbidder.com/opportunities/w912ep25x161x","key":"W912EP25X161X","url":"https://sealedbidder.com/opportunities/w912ep25x161x","title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","solicitation_number":"W912EP25X161X","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-02T18:00:00Z","first_posted":"2025-04-03","last_posted":"2025-04-04","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W074 ENDIST JACKSNVLLE","naics":"237990","psc":null,"set_aside":null,"place_state":"FL","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"12099","place_county_name":"Palm Beach County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"5c4b9d15ca69495c849e570f8a436c73","title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","solicitation_number":"W912EP25X161X","notice_type":"r","base_type":"r","posted":"2025-04-03","posted_at":"2025-04-03T21:53:01.404Z","due_at":"2025-04-18T18:00:00Z","due_date":"2025-04-18","cancelled":false,"archived":true,"archive_date":"2025-05-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5c4b9d15ca69495c849e570f8a436c73/view","enriched":true,"history":[{"index":3,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-04T21:31:21.150Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e945a2a32b454a1bad36e6dd864f1bb4","solicitation_number":"W912EP25X161X","parent_opportunity_id":"5c4b9d15ca69495c849e570f8a436c73"},{"index":1,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T21:53:01.404Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c4b9d15ca69495c849e570f8a436c73","solicitation_number":"W912EP25X161X"}]},{"notice_id":"e945a2a32b454a1bad36e6dd864f1bb4","title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","solicitation_number":"W912EP25X161X","notice_type":"r","base_type":"r","posted":"2025-04-04","posted_at":"2025-04-04T21:31:21.150Z","due_at":"2025-05-02T18:00:00Z","due_date":"2025-05-02","cancelled":false,"archived":true,"archive_date":"2025-05-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e945a2a32b454a1bad36e6dd864f1bb4/view","enriched":true,"history":[{"index":3,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-04T21:31:21.150Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e945a2a32b454a1bad36e6dd864f1bb4","solicitation_number":"W912EP25X161X","parent_opportunity_id":"5c4b9d15ca69495c849e570f8a436c73"},{"index":1,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T21:53:01.404Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c4b9d15ca69495c849e570f8a436c73","solicitation_number":"W912EP25X161X"}]}],"latest_notice_id":"e945a2a32b454a1bad36e6dd864f1bb4","first_type":"r","notices":[{"dates":{"posted":"2025-04-03","posted_at":"2025-04-03T21:53:01.404Z","created_at":"2025-04-03T21:24:07.385Z","modified_at":"2025-05-18T04:00:14.936Z","response_deadline":{"raw":"2025-04-18T14:00:00-04:00","utc":"2025-04-18T18:00:00Z","date":"2025-04-18","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5c4b9d15ca69495c849e570f8a436c73/view"},"naics":{"codes":["237990"],"primary":"237990"},"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","agency":{"office":{"code":"W912EP","name":"W074 ENDIST JACKSNVLLE"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"32207-0019","city":"JACKSONVILLE","state":"FL","country":"USA"},"organization_id":"100221797","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-03","archive_type":"auto15"},"history":[{"index":3,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-04T21:31:21.150Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e945a2a32b454a1bad36e6dd864f1bb4","solicitation_number":"W912EP25X161X","parent_opportunity_id":"5c4b9d15ca69495c849e570f8a436c73"},{"index":1,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T21:53:01.404Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c4b9d15ca69495c849e570f8a436c73","solicitation_number":"W912EP25X161X"}],"contacts":[{"name":"Chad Manson","role":"primary","email":"chad.d.manson@usace.army.mil","phone":"9042323420"},{"name":"Anelis NAZARIO CASTILLO","role":"secondary","email":"anelis.i.nazario-castillo@usace.army.mil","phone":"9042323285"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"5c4b9d15ca69495c849e570f8a436c73","lineage_id":"5c4b9d15ca69495c849e570f8a436c73","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T03:45:18.111987480Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"915ada59ea702a804dacd88f01ee2dc25661b7d38e29db91824b1e3d2cab7907","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T03:45:18.111987480Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>Sources Sought Synopsis</strong></p>\n\n<p><strong>W912EP25X161X</strong></p>\n\n<p><strong>Central Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida</strong></p>\n\n<p></p>\n\n<p>This announcement is to notify industry about the Government&rsquo;s intent to incorporate a brand name product requirement in an upcoming construction project.&nbsp; The product is the Supervisory Control And Data Acquisition (SCADA) system.&nbsp; This product is being considered to be included in the specifications to build a seepage pump station. &nbsp;This announcement seeks information from industry and will only be used for preliminary planning purposes.&nbsp; THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS.&nbsp; Respondents will not be notified of the results of the evaluation.&nbsp;</p>\n\n<p></p>\n\n<p>The U.S. Army Corps of Engineers, Jacksonville District (SAJ) intends to include a product peculiar to only one brand name equipment manufacturer in its construction specifications under the authority 10 U.S.C. 3204(a)(1), Only one responsible source and no other supplies or services will satisfy agency requirements (FAR 6.302-1).&nbsp; This notification is issued as a means of conducting market research to determine if the Government&rsquo;s rational to require a SCADA system is justified.&nbsp; This requirement is for a potential fiscal year (FY) 2026 award.&nbsp; The project work consists of the construction of a seepage pump station at S-636 in Palm Beach Country, Florida for the&nbsp; CEPP Contract 11C, EAA A-2 Reservoir program.&nbsp;</p>\n\n<p></p>\n\n<p>The SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP.&nbsp; These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. &nbsp;It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.</p>\n\n<p></p>\n\n<p>This is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636.&nbsp; The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.</p>\n\n<p></p>\n\n<p>The purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.</p>\n\n<p></p>\n\n<p>The S-636 (CNT11C) Project is designed to perform two primary functions:</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Manage and maintain the C-636 (Seepage Canal) within an authorized range.</p>\n\n<p></p>\n\n<p><strong>Project Description:</strong></p>\n\n<p></p>\n\n<p>The work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.</p>\n\n<p></p>\n\n<p>The new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.</p>\n\n<p></p>\n\n<p>The new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.</p>\n\n<p></p>\n\n<p>The SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:</p>\n\n<p></p>\n\n<p>Remote Terminal Unit Gated Culvert</p>\n\n<p><strong>Equipment Name</strong></p>\n\n<p><strong>Manufacturer</strong></p>\n\n<p><strong>Model</strong></p>\n\n<p>Fire Alarm Control Panel</p>\n\n<p>Honeywell</p>\n\n<p>5820XL</p>\n\n<p></p>\n\n<p>Honeywell</p>\n\n<p>N48PCI2L</p>\n\n<p>Converter</p>\n\n<p>Honeywell</p>\n\n<p>LANSRLU1</p>\n\n<p>Security Alarm Control Panel</p>\n\n<p>Honeywell</p>\n\n<p>VISTA-128FBP-KT18</p>\n\n<p>APC Smart-Ups</p>\n\n<p>APC</p>\n\n<p></p>\n\n<p>Transceiver, Aprisa SR+, UHF, Half-Duplex</p>\n\n<p>4RF, USA</p>\n\n<p>APSQ-N400-SSC-HD-22-ENAA</p>\n\n<p>Transceiver, Aprisa SR+, VHF, Half-Duplex</p>\n\n<p>4RF, USA</p>\n\n<p>APSQ-N135-SSC-HD-22-ENAA</p>\n\n<p>Controller, 6A, 12VDC, Solar, Charger</p>\n\n<p>Morningstar</p>\n\n<p>SS-6</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core</p>\n\n<p>Times Microwave Sys.</p>\n\n<p>LMR400</p>\n\n<p>Connector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific</p>\n\n<p>Times Microwave Sys.</p>\n\n<p>TC-400-NMH-D</p>\n\n<p>Protector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female</p>\n\n<p>Polyphaser</p>\n\n<p>IS-50NX-C2</p>\n\n<p>Radio Modem, Integra-Tr, Site Specific VHF/UHF</p>\n\n<p>CalAmp</p>\n\n<p>242-40W8-XYZ*</p>\n\n<p>Cable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF</p>\n\n<p>Pasternack</p>\n\n<p>PE3662-72</p>\n\n<p>Cable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard</p>\n\n<p>Graybar</p>\n\n<p>GRA031D1217-007</p>\n\n<p>Base Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame</p>\n\n<p>Motorola</p>\n\n<p>7509</p>\n\n<p>Frame Option, RTU, ACE3600, 3 I/O Slots</p>\n\n<p>Motorola</p>\n\n<p>V103</p>\n\n<p>I/O Module, RTU, ACE3600, 32 Di Fast 24V</p>\n\n<p>Motorola</p>\n\n<p>V379</p>\n\n<p>I/O Module, RTU, ACE3600, 16 Do Ee Relay 2A</p>\n\n<p>Motorola</p>\n\n<p>V616</p>\n\n<p>Power Supply, RTU, ACE3600, Dc Power Supply 18-72V</p>\n\n<p>Motorola</p>\n\n<p>V251</p>\n\n<p>CPU, RTU, ACE3600, 3640, Upgrade</p>\n\n<p>Motorola</p>\n\n<p>V446</p>\n\n<p>I/O Module, RTU, ACE3600, 8Ai +/-20 Ma</p>\n\n<p>Motorola</p>\n\n<p>V318</p>\n\n<p>Plug-In, RTU, ACE3600, RS-232</p>\n\n<p>Motorola</p>\n\n<p>V184</p>\n\n<p>HMI Control Panel</p>\n\n<p>Allen-Bradley</p>\n\n<p>PanelView Plus 1900</p>\n\n<p>&quot;</p>\n\n<p>Allen-Bradley</p>\n\n<p>Compact Logix PLC</p>\n\n<p>&quot;</p>\n\n<p>Motorola</p>\n\n<p>ACE-3600</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core</p>\n\n<p>Times Microwave Sys.</p>\n\n<p>LMR-400-BULK</p>\n\n<p>Connector, Coaxial, N-Male, Right Angle, Lmr-400</p>\n\n<p>Times Microwave Sys.</p>\n\n<p>TC-400-NMH-RA-SS</p>\n\n<p>L-Foot, Solar Panel Rail, W/T-Bolt, Mill</p>\n\n<p>Unirac</p>\n\n<p>304001C</p>\n\n<p>Panel, 345 Watt, Solar</p>\n\n<p>Mission Solar Energy</p>\n\n<p>MSE345SX5T</p>\n\n<p>Rail, Solar Panel Racking 168-Inch, Clear</p>\n\n<p>Unirac</p>\n\n<p>310168C</p>\n\n<p>Connector, Gnd, Lay-In, 4-14, #10, Tin</p>\n\n<p>ILSCO/REXEL</p>\n\n<p>GBL-4DBT</p>\n\n<p>Nut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt</p>\n\n<p>McMaster-Carr</p>\n\n<p>92673A125</p>\n\n<p>Nut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>96278A511</p>\n\n<p>Nut, Hex, Ext Toothed Lk 10-32, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>96278A411</p>\n\n<p>Plate, Backing, 2-13/16&quot; C-C Spacing</p>\n\n<p>Sterling Industry</p>\n\n<p></p>\n\n<p>Screw, Hex Hd, 1/4-20 X .75, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>93190A540</p>\n\n<p>Screw, Hex Hd, 3/8-16 X .3, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>92186A636</p>\n\n<p>Screw, Hex Hd, Serflg,10-32 X .75, 18-8</p>\n\n<p>McMaster-Carr</p>\n\n<p>97646A243</p>\n\n<p>Spar, Left, Vert, Solar Panel Bracket</p>\n\n<p>Sterling Industry</p>\n\n<p></p>\n\n<p>Spar, Right, Vert, Solar Panel Bracket</p>\n\n<p>Sterling Industry</p>\n\n<p></p>\n\n<p>U-Bolt,3/8-16, 2-7/16 Id, Galv. Steel</p>\n\n<p>McMaster-Carr</p>\n\n<p>8862T29</p>\n\n<p>Washer, Flat,1/4, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>90107A029</p>\n\n<p>Washer, Split, 3/8, 18-8 SS</p>\n\n<p>McMaster-Carr</p>\n\n<p>92146A031</p>\n\n<p>Weldment, Triangle, Solar Panel Bracket</p>\n\n<p>Sterling Industry</p>\n\n<p></p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Model #8510110</p>\n\n<p>DBI/SALA</p>\n\n<p>8510110</p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Cap Model #8510827</p>\n\n<p>DBI/SALA</p>\n\n<p>8510827</p>\n\n<p>Ladder Tie D-Bolt Anchorage Connector Model 417SS</p>\n\n<p>MILLER</p>\n\n<p>417SS</p>\n\n<p>Hilti Hit-Re 500 V3 With 3/4&quot; Has [304 316] 53/4&quot; Embedment</p>\n\n<p>HILTI</p>\n\n<p>HIT-RE 500 V3</p>\n\n<p>Face Mount SS Davit Sleeve DBI/Sala Model #8518348</p>\n\n<p>DBI/SALA</p>\n\n<p>8518348</p>\n\n<p>Stainless Mini Rotary Latch Right Hand</p>\n\n<p>EBERHARD</p>\n\n<p>8-240 R</p>\n\n<p>Gate Hinge Assembly Self Closing</p>\n\n<p>D&amp;D Technologies</p>\n\n<p></p>\n\n<p>Amphenol 90&deg; Connector</p>\n\n<p>Amphenol</p>\n\n<p>MS3108E-14S-6S</p>\n\n<p>3/8&quot;-16 Pem Nut-SS Installed in the Side of Enclosure</p>\n\n<p>PEM</p>\n\n<p>CLS-0616-X</p>\n\n<p>1/4&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face</p>\n\n<p>PEM</p>\n\n<p>CLS-0420-3</p>\n\n<p>1/2&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face</p>\n\n<p>PEM</p>\n\n<p>CLS-0813-2 (No CLS-0813-3 LISTED)</p>\n\n<p>Aluminum 1/4&quot; Thick Hinge</p>\n\n<p>McMaster-Carr</p>\n\n<p>1609A2</p>\n\n<p>Test Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces</p>\n\n<p>CHLOR*RID International Inc.</p>\n\n<p>CHLOR*TEST CSN Salts</p>\n\n<p>Test Kit for Identifying Amine Blush on Epoxy Surfaces</p>\n\n<p>Elcometer</p>\n\n<p>Amine Blush Check</p>\n\n<p>Drawer Pull</p>\n\n<p></p>\n\n<p>B02011</p>\n\n<p>Drawer Slides</p>\n\n<p></p>\n\n<p>B05051/B05052/B05053</p>\n\n<p>Door Pull</p>\n\n<p></p>\n\n<p>B02201</p>\n\n<p>Four Pin Disk Tumbler Lock</p>\n\n<p>Illinois Lock Company</p>\n\n<p>DUO A</p>\n\n<p>Horn</p>\n\n<p>Federal Signal Corporation</p>\n\n<p>1N742</p>\n\n<p>4A969 Weatherproof Box</p>\n\n<p>Federal Signal Corporation</p>\n\n<p>4A969</p>\n\n<p>Anti-Seize</p>\n\n<p>Bostik</p>\n\n<p>Never Seez</p>\n\n<p>1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor</p>\n\n<p>Sumitomo</p>\n\n<p></p>\n\n<p>Chatsworth Universal Rack<br />\nW/ Base Insulators</p>\n\n<p>Chatsworth</p>\n\n<p>46053-515<br />\n10605-019</p>\n\n<p>120VAC Rackmount Power Strip</p>\n\n<p>APC</p>\n\n<p>PDU-AP8632</p>\n\n<p>Fiber Optic Inside Plant Patch Panel</p>\n\n<p>Corning</p>\n\n<p>CCH-02U/MMCCH LC</p>\n\n<p>Fiber Optic Inside Plant Patch Panel</p>\n\n<p>Corning</p>\n\n<p>SM-CCH LC</p>\n\n<p>Scada Switch</p>\n\n<p>Cisco</p>\n\n<p>Catalyst C9200L-24P-4X,<br />\nPWR-C5-600WAC</p>\n\n<p>Scada Switch Wire Management</p>\n\n<p>Chatsworth</p>\n\n<p>30530-719</p>\n\n<p>Scada Patch Panel 24 Port</p>\n\n<p>Siemon</p>\n\n<p>HD6-24</p>\n\n<p>Enterprise Switch</p>\n\n<p>Cisco</p>\n\n<p>Catalyst C9200L-48P-4X<br />\nPWR-C5-1kWAC</p>\n\n<p>SCADA Patch Panel</p>\n\n<p>Siemon</p>\n\n<p>HD6-48</p>\n\n<p>KVM Rack Mount Console</p>\n\n<p>Tripp Lite</p>\n\n<p>B021-00017</p>\n\n<p>Server 6TB</p>\n\n<p>Salient</p>\n\n<p>BL06T3B, 16CV</p>\n\n<p>CCTV Switch</p>\n\n<p>Fortinet</p>\n\n<p>CDW part# 4105407</p>\n\n<p>CCTV TVSS</p>\n\n<p>DITEK</p>\n\n<p>DTK-RM24NETS</p>\n\n<p>It System Ups</p>\n\n<p>APC</p>\n\n<p>SMART-UPS Model SURTA2200RWXL2U</p>\n\n<p>Ess System Ups</p>\n\n<p>APC</p>\n\n<p>SMART-UPS Model SURTA2200RWXL2U</p>\n\n<p>Single Mode Fiber Optic Patch Panel - Corning 24 Pair.</p>\n\n<p>Corning</p>\n\n<p></p>\n\n<p>Solara #20033-2, 20033-9, 20033-10</p>\n\n<p>Solara</p>\n\n<p>20033-2, 20033-9, 20033-10</p>\n\n<p>Digital Shaft Encoder</p>\n\n<p>Design Analysis Associates</p>\n\n<p>H-3341 Water Log Series</p>\n\n<p>Mounted Pump Cutoff Switches</p>\n\n<p>Jerguson</p>\n\n<p>Jerguson Model JDC1D<br />\nJerguson Model JDC2D</p>\n\n<p>Ultrasonic Level Sensors</p>\n\n<p>Drexelbrook</p>\n\n<p>USonic-R Series or equal.</p>\n\n<p>Lightning/Surge: General<br />\nLine Noise Suppressing Isolation Transformers and Surge Suppressors.</p>\n\n<p></p>\n\n<p>Topaz Series 30 Ultra<br />\nIsolators or equal</p>\n\n<p>Lightning/Surge: Power Supply<br />\nLine Noise Suppressing Isolation Transformers and Surge Suppressors.</p>\n\n<p>Edco</p>\n\n<p>HSP-121 or equal</p>\n\n<p>Lightning/Surge Protection: Analog</p>\n\n<p>Edco</p>\n\n<p>PC 642 or SRA 64</p>\n\n<p>Lightning/Surge Protection: Analog</p>\n\n<p>Edco</p>\n\n<p>SS64 series or equal</p>\n\n<p>Lightning/Surge Protection: Analog</p>\n\n<p>Edco</p>\n\n<p>SLAC series or equal</p>\n\n<p>Norton Utilities</p>\n\n<p>Norton</p>\n\n<p>Norton Utilities (latest version)</p>\n\n<p>One (1) Dell Timbuk2 16&quot; Carry Case</p>\n\n<p>Dell</p>\n\n<p>Dell Timbuk2 16&quot; carry case</p>\n\n<p>Aircable Wireless Serial Connector</p>\n\n<p>Aircable</p>\n\n<p>ACC1202<br />\nCC1302</p>\n\n<p>ATI&#39;s Mobility&reg; Radeon&trade; Hd3670 - 512Mb</p>\n\n<p>ATI</p>\n\n<p>HD3670</p>\n\n<p>Dell Latitude E6410At6 Or Latest Version</p>\n\n<p>Dell</p>\n\n<p>E6410AT6</p>\n\n<p>Microsoft Office (Latest Version)</p>\n\n<p>Microsoft</p>\n\n<p>Office</p>\n\n<p>Dell Wireless 370 Bluetooth Module (2-1 + EDR)</p>\n\n<p>Dell</p>\n\n<p>Wireless 370 Bluetooth module (2-1 + EDR)</p>\n\n<p>Rockwell Software&#39;s RSLogix5000 (Newest Version).</p>\n\n<p>Rockwell Software</p>\n\n<p>RSLogix5000<br />\n(newest version)</p>\n\n<p>Pro Soft Modbus Master/Slave Communications Interface Module for Control Logix</p>\n\n<p>Pro Soft</p>\n\n<p>MV156-MCM</p>\n\n<p>Allen-Bradley Stratix 5700</p>\n\n<p>Allen-Bradley</p>\n\n<p>Stratix 5700</p>\n\n<p>Allen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core.</p>\n\n<p>Allen-Bradley</p>\n\n<p>PV1900</p>\n\n<p>Allen-Bradley PanelView Plus</p>\n\n<p>Allen-Bradley</p>\n\n<p>PB1900</p>\n\n<p>Hoffman Consolet</p>\n\n<p>Hoffman</p>\n\n<p></p>\n\n<p>Capwap Software</p>\n\n<p>Pile Dynamics, Inc.</p>\n\n<p>Case Pile Wave Analysis Program software</p>\n\n<p>Testing Equipment</p>\n\n<p>Pile Dynamics, Inc.</p>\n\n<p>8G or PAX or equal</p>\n\n<p>The O-Rings on a Quick Disconnect</p>\n\n<p>Chemours</p>\n\n<p>Viton</p>\n\n<p>Simplex Compact Fuel Port</p>\n\n<p>Simplex</p>\n\n<p>Simplex Compact Fuel Port</p>\n\n<p>Pump Bearings</p>\n\n<p>Thordon</p>\n\n<p></p>\n\n<p>Shaft Couplings</p>\n\n<p>Aquamet</p>\n\n<p>Aquamet 22, Aqualoy 22, Nitronic 50 or approved equal</p>\n\n<p>Shafts</p>\n\n<p>Aquamet</p>\n\n<p>Aquamet 22, Aqualoy 22, Nitronic 50 or approved equal</p>\n\n<p>Shaft Bearing or Packing Box Sleeves</p>\n\n<p>Aquamet</p>\n\n<p>Aquamet 22, Aqualoy 22, Nitronic 50 or approved equal</p>\n\n<p>O-Rings</p>\n\n<p></p>\n\n<p>O-Rings Buna-N or Viton or approved equal</p>\n\n<p>Epoxy Coating</p>\n\n<p>Chesterton</p>\n\n<p>Chesteron ARC Epoxy coating.</p>\n\n<p>Dynamic Analysis Model Program</p>\n\n<p></p>\n\n<p>Ansys, Cosmos/M, or equivalent</p>\n\n<p>625kW Tier 4, Diesel Generator</p>\n\n<p>Power Secure</p>\n\n<p>Tier 4</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p>Total Current Estimated Cost</p>\n\n<p>$732,319.65</p>\n\n<p></p>\n\n<p></p>\n\n<p>A number of contractors are sufficiently qualified to assemble the system, and a large number of suppliers sell the major components. However, the major components themselves are only manufactured by a single source. The government would incur substantial duplication of cost if non-standard major components from other manufacturers were allowed. These additional costs occur in several areas:</p>\n\n<p></p>\n\n<p>a.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Operator Training. Operators are currently trained to operate the Central Control System with its standardized major components. Substitution of non-standard major components into the Central Control System will substantially increase the training time necessary for the operator to become proficient. Operating a variety of diverse major components also decreases productivity and increases probability for error.</p>\n\n<p></p>\n\n<p>b.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Maintenance Technical Training. Maintenance technicians are currently trained to repair and maintain the standardized components of the Central Control System. Allowing non-standard major components to be installed in the system would result in substantial increases in the training required for each technician to be fully trained on each diverse make of a major component. Frequently, this training is conducted only at out-of-area facilities and would result in TDY and training costs. Non-standard equipment would also decrease the efficiency in which a major component is repaired, as technicians would have less experience on a particular make of major equipment than they do on the standardized major equipment.</p>\n\n<p></p>\n\n<p>c.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Spare Parts Stockage. Spare parts are currently stocked for the standardized major components of the Central Control System. These spare parts are a major investment for the government. Allowing non-standard major components to be installed would require an exponential increase in the number of spare parts required and thus an exponential increase in the space required and government investment in supplies. Space and money limitations would result in non-stockage of many items, which would dramatically increase part non-availability. This could be a critical problem during normal operations and a potential catastrophic problem during severe storm events.</p>\n\n<p></p>\n\n<p>d.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; System testing and reliability. The Central Control System has been specifically designed to incorporate certain standardized major components. These components have been selected as a result of extensive industry research, have been exhaustively tested, and have been found to be reliable and dependable in many prior installations. Installation of non-standard major components would incur increased costs due to lack of testing of the component as part of the Central Control System. An individual non-standard component may perform well in another application, but it could interface poorly with the overall Central Control System due to interoperability problems. A non-standard component may also perform well on initial installation, but then fail due to the rigorous environmental conditions it is subjected to or due to poorer quality than the standard item.</p>\n\n<p></p>\n\n<p>e.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Increase down time due to no interchangeability of major components. Currently, individual components of major components may be interchanged between structures to keep critical structures operating. The use of non- standard parts will increase costs, as individual components of the major components will not be interchangeable. If a part is not in stock and has to be ordered, it could take several days for the control system to be repaired at an individual structure. During this time, additional costs will be incurred by the government, as an operator will have to be based on site or drive out to the site to operate the structure.</p>\n\n<p></p>\n\n<p>f.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Potential property destruction and civilian deaths due to non-availability and non-interchangeability of the system during storm events. SFWMD depends on the Central Control System to operate a large number of structures remotely in the event of a severe storm event (hurricane, tropical storm, etc.). Problems with the above five items will increase system down time and system repair time, which will increase the time that individual structures cannot be operated remotely. During normal conditions, structures may be operated locally by a SFWMD employee who will drive to the structure and use local operating controls. However, in the event of a severe storm, travel conditions are frequently extremely hazardous or impossible due to impassible roads, extremely high winds, and flooding. The inability to operate an individual structure, either remotely or locally, could easily cause flooding in the area controlled by the structure, which will likely cause property damage and potential deaths.</p>\n\n<p></p>\n\n<p>The magnitude of the construction project is between $25,000,000 and $100,000,000.&nbsp; The work is in Palm Beach County, Florida.&nbsp; A firm fixed contract is being contemplated for this project. The funding for this project is Civil Works.&nbsp; A date of solicitation has not yet been determined; however, a project focused sources sought is contemplated to be issued in the near future, and that time a solicitation release date or range should be known.&nbsp;</p>\n\n<p></p>\n\n<p><strong>Response Instructions to this Sources Sought Notice:</strong></p>\n\n<p></p>\n\n<ol>\n\t<li>The government is seeking equivalent systems.&nbsp; To be considered as an equivalent system, the offer must provide a list of components and describe how the equivalent product is the same, discuss advantages/disadvantages of the system, and show how this alternative product will satisfy paragraphs (a) through (f) of the product description using support information and product literature.&nbsp; Especially addressing how the proposed equivalent products meets the interoperability and reliability requirements discussed above in paragraphs (a) through (f). Any submission of an equivalent product will be technically evaluated to determine if this item will satisfy the Government&rsquo;s need.&nbsp; The results will not be shared but will be reflected in the final project specifications.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li>If there are no other equivalent models to the SCADA system discussed in (1) above:&nbsp; Please let us know there are no equivalents available in the market, and discuss how relaxing some of the requirements, if any, could allow for an equivalent type product and identify that product.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li><strong>Industry is asked to submit their responses as follows:</strong></li>\n</ol>\n\n<p></p>\n\n<p>Firm&rsquo;s response to this Synopsis shall be limited to 10 pages and shall include the following information:</p>\n\n<p></p>\n\n<p>1.&nbsp; Firm&rsquo;s name, address, point of contact, phone number, website, and email address.</p>\n\n<p></p>\n\n<p>2.&nbsp; Firm&rsquo;s interest in submitting a proposal on the solicitation when advertised.&nbsp; Let us know if you would prefer a 1. A salient description of the SCADA system in the specifications; essentially SCADA or equal, or 2. SCADA brand name</p>\n\n<p></p>\n\n<p>3. If your firm is a Small Business, be sure you understand the performance of work requirements for your specific socioeconomic category. i.e. SB, 8(a), SDVOSB, WOSB, or HUBZone.&nbsp;</p>\n\n<p></p>\n\n<p>4. If significant subcontracting or teaming is anticipated in order to deliver technical capability, firms should address the structure of such arrangements to include Joint Venture information, if applicable &ndash; existing and potential.</p>\n\n<p></p>\n\n<p>5.&nbsp; Firm&rsquo;s Bonding Capability (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars) via letter from bonding company.</p>\n\n<p></p>\n\n<p>6. Firm&rsquo;s responses to the following technical questions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p></p>\n\n<p>All responses to this Source Sought Synopsis will be evaluated and used in determining acquisition strategy and project specifications.</p>\n\n<p></p>\n\n<p>Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed project are invited to submit a response to this Sources Sought Synopsis by no later than April 28, 2025 at 2:00PM, EST.&nbsp; All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.</p>\n\n<p></p>\n\n<p>Prior Government contract work is not required for submitting a response under this Sources Sought.</p>\n\n<p></p>\n\n<p>You must be registered with the System for Award Management (SAM) in order to receive a Government contract award.</p>\n\n<p></p>\n\n<p>To register, go to www.sam.gov. For additional information visit the website for the Federal Service Desk (www.FSD.gov) which supports SAM or contact them at 866-606-8220 for assistance.</p>","text":"Sources Sought Synopsis\n\nW912EP25X161X\n\nCentral Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida\n\nThis announcement is to notify industry about the Government’s intent to incorporate a brand name product requirement in an upcoming construction project. The product is the Supervisory Control And Data Acquisition (SCADA) system. This product is being considered to be included in the specifications to build a seepage pump station. This announcement seeks information from industry and will only be used for preliminary planning purposes. THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. Respondents will not be notified of the results of the evaluation.\n\nThe U.S. Army Corps of Engineers, Jacksonville District (SAJ) intends to include a product peculiar to only one brand name equipment manufacturer in its construction specifications under the authority 10 U.S.C. 3204(a)(1), Only one responsible source and no other supplies or services will satisfy agency requirements (FAR 6.302-1). This notification is issued as a means of conducting market research to determine if the Government’s rational to require a SCADA system is justified. This requirement is for a potential fiscal year (FY) 2026 award. The project work consists of the construction of a seepage pump station at S-636 in Palm Beach Country, Florida for the CEPP Contract 11C, EAA A-2 Reservoir program.\n\nThe SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP. These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.\n\nThis is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636. The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.\n\nThe purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.\n\nThe S-636 (CNT11C) Project is designed to perform two primary functions:\n\n• Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)\n\n• Manage and maintain the C-636 (Seepage Canal) within an authorized range.\n\nProject Description:\n\nThe work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.\n\nThe new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.\n\nThe new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.\n\nThe SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:\n\nRemote Terminal Unit Gated Culvert\n\nEquipment Name\n\nManufacturer\n\nModel\n\nFire Alarm Control Panel\n\nHoneywell\n\n5820XL\n\nHoneywell\n\nN48PCI2L\n\nConverter\n\nHoneywell\n\nLANSRLU1\n\nSecurity Alarm Control Panel\n\nHoneywell\n\nVISTA-128FBP-KT18\n\nAPC Smart-Ups\n\nAPC\n\nTransceiver, Aprisa SR+, UHF, Half-Duplex\n\n4RF, USA\n\nAPSQ-N400-SSC-HD-22-ENAA\n\nTransceiver, Aprisa SR+, VHF, Half-Duplex\n\n4RF, USA\n\nAPSQ-N135-SSC-HD-22-ENAA\n\nController, 6A, 12VDC, Solar, Charger\n\nMorningstar\n\nSS-6\n\nCable, Coaxial, Flexible, Low Loss, Solid Core\n\nTimes Microwave Sys.\n\nLMR400\n\nConnector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific\n\nTimes Microwave Sys.\n\nTC-400-NMH-D\n\nProtector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female\n\nPolyphaser\n\nIS-50NX-C2\n\nRadio Modem, Integra-Tr, Site Specific VHF/UHF\n\nCalAmp\n\n242-40W8-XYZ*\n\nCable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF\n\nPasternack\n\nPE3662-72\n\nCable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard\n\nGraybar\n\nGRA031D1217-007\n\nBase Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame\n\nMotorola\n\n7509\n\nFrame Option, RTU, ACE3600, 3 I/O Slots\n\nMotorola\n\nV103\n\nI/O Module, RTU, ACE3600, 32 Di Fast 24V\n\nMotorola\n\nV379\n\nI/O Module, RTU, ACE3600, 16 Do Ee Relay 2A\n\nMotorola\n\nV616\n\nPower Supply, RTU, ACE3600, Dc Power Supply 18-72V\n\nMotorola\n\nV251\n\nCPU, RTU, ACE3600, 3640, Upgrade\n\nMotorola\n\nV446\n\nI/O Module, RTU, ACE3600, 8Ai +/-20 Ma\n\nMotorola\n\nV318\n\nPlug-In, RTU, ACE3600, RS-232\n\nMotorola\n\nV184\n\nHMI Control Panel\n\nAllen-Bradley\n\nPanelView Plus 1900\n\n\"\n\nAllen-Bradley\n\nCompact Logix PLC\n\n\"\n\nMotorola\n\nACE-3600\n\nCable, Coaxial, Flexible, Low Loss, Solid Core\n\nTimes Microwave Sys.\n\nLMR-400-BULK\n\nConnector, Coaxial, N-Male, Right Angle, Lmr-400\n\nTimes Microwave Sys.\n\nTC-400-NMH-RA-SS\n\nL-Foot, Solar Panel Rail, W/T-Bolt, Mill\n\nUnirac\n\n304001C\n\nPanel, 345 Watt, Solar\n\nMission Solar Energy\n\nMSE345SX5T\n\nRail, Solar Panel Racking 168-Inch, Clear\n\nUnirac\n\n310168C\n\nConnector, Gnd, Lay-In, 4-14, #10, Tin\n\nILSCO/REXEL\n\nGBL-4DBT\n\nNut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt\n\nMcMaster-Carr\n\n92673A125\n\nNut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS\n\nMcMaster-Carr\n\n96278A511\n\nNut, Hex, Ext Toothed Lk 10-32, 18-8 SS\n\nMcMaster-Carr\n\n96278A411\n\nPlate, Backing, 2-13/16\" C-C Spacing\n\nSterling Industry\n\nScrew, Hex Hd, 1/4-20 X .75, 18-8 SS\n\nMcMaster-Carr\n\n93190A540\n\nScrew, Hex Hd, 3/8-16 X .3, 18-8 SS\n\nMcMaster-Carr\n\n92186A636\n\nScrew, Hex Hd, Serflg,10-32 X .75, 18-8\n\nMcMaster-Carr\n\n97646A243\n\nSpar, Left, Vert, Solar Panel Bracket\n\nSterling Industry\n\nSpar, Right, Vert, Solar Panel Bracket\n\nSterling Industry\n\nU-Bolt,3/8-16, 2-7/16 Id, Galv. Steel\n\nMcMaster-Carr\n\n8862T29\n\nWasher, Flat,1/4, 18-8 SS\n\nMcMaster-Carr\n\n90107A029\n\nWasher, Split, 3/8, 18-8 SS\n\nMcMaster-Carr\n\n92146A031\n\nWeldment, Triangle, Solar Panel Bracket\n\nSterling Industry\n\nCore Mount SS Davit Sleeve DBI/Sala Model #8510110\n\nDBI/SALA\n\n8510110\n\nCore Mount SS Davit Sleeve DBI/Sala Cap Model #8510827\n\nDBI/SALA\n\n8510827\n\nLadder Tie D-Bolt Anchorage Connector Model 417SS\n\nMILLER\n\n417SS\n\nHilti Hit-Re 500 V3 With 3/4\" Has [304 316] 53/4\" Embedment\n\nHILTI\n\nHIT-RE 500 V3\n\nFace Mount SS Davit Sleeve DBI/Sala Model #8518348\n\nDBI/SALA\n\n8518348\n\nStainless Mini Rotary Latch Right Hand\n\nEBERHARD\n\n8-240 R\n\nGate Hinge Assembly Self Closing\n\nD&D Technologies\n\nAmphenol 90° Connector\n\nAmphenol\n\nMS3108E-14S-6S\n\n3/8\"-16 Pem Nut-SS Installed in the Side of Enclosure\n\nPEM\n\nCLS-0616-X\n\n1/4\" - 20 Pem Nut - SS Pressed In - From Bottom Face\n\nPEM\n\nCLS-0420-3\n\n1/2\" - 20 Pem Nut - SS Pressed In - From Bottom Face\n\nPEM\n\nCLS-0813-2 (No CLS-0813-3 LISTED)\n\nAluminum 1/4\" Thick Hinge\n\nMcMaster-Carr\n\n1609A2\n\nTest Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces\n\nCHLOR*RID International Inc.\n\nCHLOR*TEST CSN Salts\n\nTest Kit for Identifying Amine Blush on Epoxy Surfaces\n\nElcometer\n\nAmine Blush Check\n\nDrawer Pull\n\nB02011\n\nDrawer Slides\n\nB05051/B05052/B05053\n\nDoor Pull\n\nB02201\n\nFour Pin Disk Tumbler Lock\n\nIllinois Lock Company\n\nDUO A\n\nHorn\n\nFederal Signal Corporation\n\n1N742\n\n4A969 Weatherproof Box\n\nFederal Signal Corporation\n\n4A969\n\nAnti-Seize\n\nBostik\n\nNever Seez\n\n1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor\n\nSumitomo\n\nChatsworth Universal Rack\n\nW/ Base Insulators\n\nChatsworth\n\n46053-515\n\n10605-019\n\n120VAC Rackmount Power Strip\n\nAPC\n\nPDU-AP8632\n\nFiber Optic Inside Plant Patch Panel\n\nCorning\n\nCCH-02U/MMCCH LC\n\nFiber Optic Inside Plant Patch Panel\n\nCorning\n\nSM-CCH LC\n\nScada Switch\n\nCisco\n\nCatalyst C9200L-24P-4X,\n\nPWR-C5-600WAC\n\nScada Switch Wire Management\n\nChatsworth\n\n30530-719\n\nScada Patch Panel 24 Port\n\nSiemon\n\nHD6-24\n\nEnterprise Switch\n\nCisco\n\nCatalyst C9200L-48P-4X\n\nPWR-C5-1kWAC\n\nSCADA Patch Panel\n\nSiemon\n\nHD6-48\n\nKVM Rack Mount Console\n\nTripp Lite\n\nB021-00017\n\nServer 6TB\n\nSalient\n\nBL06T3B, 16CV\n\nCCTV Switch\n\nFortinet\n\nCDW part# 4105407\n\nCCTV TVSS\n\nDITEK\n\nDTK-RM24NETS\n\nIt System Ups\n\nAPC\n\nSMART-UPS Model SURTA2200RWXL2U\n\nEss System Ups\n\nAPC\n\nSMART-UPS Model SURTA2200RWXL2U\n\nSingle Mode Fiber Optic Patch Panel - Corning 24 Pair.\n\nCorning\n\nSolara #20033-2, 20033-9, 20033-10\n\nSolara\n\n20033-2, 20033-9, 20033-10\n\nDigital Shaft Encoder\n\nDesign Analysis Associates\n\nH-3341 Water Log Series\n\nMounted Pump Cutoff Switches\n\nJerguson\n\nJerguson Model JDC1D\n\nJerguson Model JDC2D\n\nUltrasonic Level Sensors\n\nDrexelbrook\n\nUSonic-R Series or equal.\n\nLightning/Surge: General\n\nLine Noise Suppressing Isolation Transformers and Surge Suppressors.\n\nTopaz Series 30 Ultra\n\nIsolators or equal\n\nLightning/Surge: Power Supply\n\nLine Noise Suppressing Isolation Transformers and Surge Suppressors.\n\nEdco\n\nHSP-121 or equal\n\nLightning/Surge Protection: Analog\n\nEdco\n\nPC 642 or SRA 64\n\nLightning/Surge Protection: Analog\n\nEdco\n\nSS64 series or equal\n\nLightning/Surge Protection: Analog\n\nEdco\n\nSLAC series or equal\n\nNorton Utilities\n\nNorton\n\nNorton Utilities (latest version)\n\nOne (1) Dell Timbuk2 16\" Carry Case\n\nDell\n\nDell Timbuk2 16\" carry case\n\nAircable Wireless Serial Connector\n\nAircable\n\nACC1202\n\nCC1302\n\nATI's Mobility® Radeon™ Hd3670 - 512Mb\n\nATI\n\nHD3670\n\nDell Latitude E6410At6 Or Latest Version\n\nDell\n\nE6410AT6\n\nMicrosoft Office (Latest Version)\n\nMicrosoft\n\nOffice\n\nDell Wireless 370 Bluetooth Module (2-1 + EDR)\n\nDell\n\nWireless 370 Bluetooth module (2-1 + EDR)\n\nRockwell Software's RSLogix5000 (Newest Version).\n\nRockwell Software\n\nRSLogix5000\n\n(newest version)\n\nPro Soft Modbus Master/Slave Communications Interface Module for Control Logix\n\nPro Soft\n\nMV156-MCM\n\nAllen-Bradley Stratix 5700\n\nAllen-Bradley\n\nStratix 5700\n\nAllen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core.\n\nAllen-Bradley\n\nPV1900\n\nAllen-Bradley PanelView Plus\n\nAllen-Bradley\n\nPB1900\n\nHoffman Consolet\n\nHoffman\n\nCapwap Software\n\nPile Dynamics, Inc.\n\nCase Pile Wave Analysis Program software\n\nTesting Equipment\n\nPile Dynamics, Inc.\n\n8G or PAX or equal\n\nThe O-Rings on a Quick Disconnect\n\nChemours\n\nViton\n\nSimplex Compact Fuel Port\n\nSimplex\n\nSimplex Compact Fuel Port\n\nPump Bearings\n\nThordon\n\nShaft Couplings\n\nAquamet\n\nAquamet 22, Aqualoy 22, Nitronic 50 or approved equal\n\nShafts\n\nAquamet\n\nAquamet 22, Aqualoy 22, Nitronic 50 or approved equal\n\nShaft Bearing or Packing Box Sleeves\n\nAquamet\n\nAquamet 22, Aqualoy 22, Nitronic 50 or approved equal\n\nO-Rings\n\nO-Rings Buna-N or Viton or approved equal\n\nEpoxy Coating\n\nChesterton\n\nChesteron ARC Epoxy coating.\n\nDynamic Analysis Model Program\n\nAnsys, Cosmos/M, or equivalent\n\n625kW Tier 4, Diesel Generator\n\nPower Secure\n\nTier 4\n\nTotal Current Estimated Cost\n\n$732,319.65\n\nA number of contractors are sufficiently qualified to assemble the system, and a large number of suppliers sell the major components. However, the major components themselves are only manufactured by a single source. The government would incur substantial duplication of cost if non-standard major components from other manufacturers were allowed. These additional costs occur in several areas:\n\na. Operator Training. Operators are currently trained to operate the Central Control System with its standardized major components. Substitution of non-standard major components into the Central Control System will substantially increase the training time necessary for the operator to become proficient. Operating a variety of diverse major components also decreases productivity and increases probability for error.\n\nb. Maintenance Technical Training. Maintenance technicians are currently trained to repair and maintain the standardized components of the Central Control System. Allowing non-standard major components to be installed in the system would result in substantial increases in the training required for each technician to be fully trained on each diverse make of a major component. Frequently, this training is conducted only at out-of-area facilities and would result in TDY and training costs. Non-standard equipment would also decrease the efficiency in which a major component is repaired, as technicians would have less experience on a particular make of major equipment than they do on the standardized major equipment.\n\nc. Spare Parts Stockage. Spare parts are currently stocked for the standardized major components of the Central Control System. These spare parts are a major investment for the government. Allowing non-standard major components to be installed would require an exponential increase in the number of spare parts required and thus an exponential increase in the space required and government investment in supplies. Space and money limitations would result in non-stockage of many items, which would dramatically increase part non-availability. This could be a critical problem during normal operations and a potential catastrophic problem during severe storm events.\n\nd. System testing and reliability. The Central Control System has been specifically designed to incorporate certain standardized major components. These components have been selected as a result of extensive industry research, have been exhaustively tested, and have been found to be reliable and dependable in many prior installations. Installation of non-standard major components would incur increased costs due to lack of testing of the component as part of the Central Control System. An individual non-standard component may perform well in another application, but it could interface poorly with the overall Central Control System due to interoperability problems. A non-standard component may also perform well on initial installation, but then fail due to the rigorous environmental conditions it is subjected to or due to poorer quality than the standard item.\n\ne. Increase down time due to no interchangeability of major components. Currently, individual components of major components may be interchanged between structures to keep critical structures operating. The use of non- standard parts will increase costs, as individual components of the major components will not be interchangeable. If a part is not in stock and has to be ordered, it could take several days for the control system to be repaired at an individual structure. During this time, additional costs will be incurred by the government, as an operator will have to be based on site or drive out to the site to operate the structure.\n\nf. Potential property destruction and civilian deaths due to non-availability and non-interchangeability of the system during storm events. SFWMD depends on the Central Control System to operate a large number of structures remotely in the event of a severe storm event (hurricane, tropical storm, etc.). Problems with the above five items will increase system down time and system repair time, which will increase the time that individual structures cannot be operated remotely. During normal conditions, structures may be operated locally by a SFWMD employee who will drive to the structure and use local operating controls. However, in the event of a severe storm, travel conditions are frequently extremely hazardous or impossible due to impassible roads, extremely high winds, and flooding. The inability to operate an individual structure, either remotely or locally, could easily cause flooding in the area controlled by the structure, which will likely cause property damage and potential deaths.\n\nThe magnitude of the construction project is between $25,000,000 and $100,000,000. The work is in Palm Beach County, Florida. A firm fixed contract is being contemplated for this project. The funding for this project is Civil Works. A date of solicitation has not yet been determined; however, a project focused sources sought is contemplated to be issued in the near future, and that time a solicitation release date or range should be known.\n\nResponse Instructions to this Sources Sought Notice:\n\n• The government is seeking equivalent systems. To be considered as an equivalent system, the offer must provide a list of components and describe how the equivalent product is the same, discuss advantages/disadvantages of the system, and show how this alternative product will satisfy paragraphs (a) through (f) of the product description using support information and product literature. Especially addressing how the proposed equivalent products meets the interoperability and reliability requirements discussed above in paragraphs (a) through (f). Any submission of an equivalent product will be technically evaluated to determine if this item will satisfy the Government’s need. The results will not be shared but will be reflected in the final project specifications.\n\n• If there are no other equivalent models to the SCADA system discussed in (1) above: Please let us know there are no equivalents available in the market, and discuss how relaxing some of the requirements, if any, could allow for an equivalent type product and identify that product.\n\n• Industry is asked to submit their responses as follows:\n\nFirm’s response to this Synopsis shall be limited to 10 pages and shall include the following information:\n\n1. Firm’s name, address, point of contact, phone number, website, and email address.\n\n2. Firm’s interest in submitting a proposal on the solicitation when advertised. Let us know if you would prefer a 1. A salient description of the SCADA system in the specifications; essentially SCADA or equal, or 2. SCADA brand name\n\n3. If your firm is a Small Business, be sure you understand the performance of work requirements for your specific socioeconomic category. i.e. SB, 8(a), SDVOSB, WOSB, or HUBZone.\n\n4. If significant subcontracting or teaming is anticipated in order to deliver technical capability, firms should address the structure of such arrangements to include Joint Venture information, if applicable – existing and potential.\n\n5. Firm’s Bonding Capability (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars) via letter from bonding company.\n\n6. Firm’s responses to the following technical questions:\n\nAll responses to this Source Sought Synopsis will be evaluated and used in determining acquisition strategy and project specifications.\n\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above-listed project are invited to submit a response to this Sources Sought Synopsis by no later than April 28, 2025 at 2:00PM, EST. All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.\n\nPrior Government contract work is not required for submitting a response under this Sources Sought.\n\nYou must be registered with the System for Award Management (SAM) in order to receive a Government contract award.\n\nTo register, go to www.sam.gov. For additional information visit the website for the Federal Service Desk (www.FSD.gov) which supports SAM or contact them at 866-606-8220 for assistance.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W912EP25X161X","place_of_performance":{"zip":"33493","state":{"code":"FL","name":"Florida"},"country":{"code":"USA","name":"UNITED STATES"}}},{"dates":{"posted":"2025-04-04","posted_at":"2025-04-04T21:31:21.150Z","created_at":"2025-04-04T21:10:50.142Z","modified_at":"2025-05-18T04:00:14.936Z","response_deadline":{"raw":"2025-05-02T14:00:00-04:00","utc":"2025-05-02T18:00:00Z","date":"2025-05-02","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e945a2a32b454a1bad36e6dd864f1bb4/view"},"naics":{"codes":["237990"],"primary":"237990"},"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","agency":{"office":{"code":"W912EP","name":"W074 ENDIST JACKSNVLLE"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"32207-0019","city":"JACKSONVILLE","state":"FL","country":"USA"},"organization_id":"100221797","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-17","archive_type":"auto15"},"history":[{"index":3,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-04T21:31:21.150Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e945a2a32b454a1bad36e6dd864f1bb4","solicitation_number":"W912EP25X161X","parent_opportunity_id":"5c4b9d15ca69495c849e570f8a436c73"},{"index":1,"title":"Brand Name - Supervisory Control And Data Acquisition (SCADA) system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-03T21:53:01.404Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"5c4b9d15ca69495c849e570f8a436c73","solicitation_number":"W912EP25X161X"}],"contacts":[{"name":"Chad Manson","role":"primary","email":"chad.d.manson@usace.army.mil","phone":"9042323420"},{"name":"Anelis NAZARIO CASTILLO","role":"secondary","email":"anelis.i.nazario-castillo@usace.army.mil","phone":"9042323285"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e945a2a32b454a1bad36e6dd864f1bb4","lineage_id":"5c4b9d15ca69495c849e570f8a436c73","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T03:26:33.559411978Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"326c0cbfa599afe80794263eb129e8aa84d39c496798916091844e793616a09e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T03:26:33.559411978Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>Sources Sought Synopsis</strong></p>\n\n<p><strong>W912EP25X161X</strong></p>\n\n<p><strong>Central Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida</strong></p>\n\n<p>This announcement is to notify industry about the Government&rsquo;s intent to incorporate a brand name product requirement in an upcoming construction project.&nbsp; The product is the Supervisory Control and Data Acquisition (SCADA) system.&nbsp; This product is being considered to be included in the specifications to build a seepage pump station. &nbsp;This announcement seeks information from industry and will only be used for preliminary planning purposes.&nbsp; THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS.&nbsp; Respondents will not be notified of the results of the evaluation.&nbsp;</p>\n\n<p>The United States Army Corps of Engineers, Jacksonville District (SAJ) intends to include the following proprietary items in a solicitation for a construction acquisition under authority of FAR 6.302-1(c)(1), only one responsible source and no other supplies or services will satisfy agency requirements. This project may include a Brand Name only component, as described below, unless the results of this sources sought notification indicates otherwise.</p>\n\n<p>This notification serves three purposes: (1) to notify potential Offerors of the Government&#39;s intent to solicit a brand name only component under a future construction project; (2) to identify potential sources that can provide the brand name only item and/or equivalent; (3) notification of USACE&rsquo;s intent to contract sole source for a Brand Name Only, if the market is unable to provide &#39;equivalent&#39; products. &nbsp;</p>\n\n<p>In the event no equivalent equipment exists, the Brand Name Only justification will be issued pursuant to FAR Part 6.302-1(c)(1), &quot;Only One Responsible Source and no other supplies or services will satisfy agency requirements&quot;. A subsequent market survey will not be published in support of a Justification and Approval (J&amp;A) for sole sourcing the resultant product(s) or system(s) in the event an equivalent product is not submitted for consideration. In such instances, the brand name or equal component will be embedded in the construction project that will be issued/solicited competitively. Only that part of the project requiring brand name components will be sole source if no sources are able to prove an equal product.</p>\n\n<p>The SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP.&nbsp; These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. &nbsp;It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.</p>\n\n<p>This is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636.&nbsp; The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.</p>\n\n<p>The purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.</p>\n\n<p>The S-636 (CNT11C) Project is designed to perform two primary functions:</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Manage and maintain the C-636 (Seepage Canal) within an authorized range.</p>\n\n<p><strong>Project Description:</strong></p>\n\n<p>The work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.</p>\n\n<p>The new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.</p>\n\n<p>The new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.</p>\n\n<p>The SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:</p>\n\n<p>Remote Terminal Unit Gated Culvert:</p>\n\n<p><strong>Equipment Name Manufacturer</strong></p>\n\n<p>Fire Alarm Control Panel - Honeywel</p>\n\n<p>Converter - Honeywell</p>\n\n<p>Security Alarm Control Panel - Honeywell</p>\n\n<p>APC Smart-Ups - APC</p>\n\n<p>Transceiver, Aprisa SR+, UHF, Half-Duplex - 4RF, USA</p>\n\n<p>Transceiver, Aprisa SR+, VHF, Half-Duplex - 4RF, USA</p>\n\n<p>Controller, 6A, 12VDC, Solar, Charger - Morningstar</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.</p>\n\n<p>Connector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific - Times Microwave Sys.</p>\n\n<p>Protector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female - Polyphaser</p>\n\n<p>Radio Modem, Integra-Tr, Site Specific VHF/UHF - CalAmp</p>\n\n<p>Cable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF - Pasternack</p>\n\n<p>Cable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard - Graybar</p>\n\n<p>Base Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame - Motorola</p>\n\n<p>Frame Option, RTU, ACE3600, 3 I/O Slots - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 32 Di Fast 24V - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 16 Do Ee Relay 2A - Motorola</p>\n\n<p>Power Supply, RTU, ACE3600, Dc Power Supply 18-72V - Motorola</p>\n\n<p>CPU, RTU, ACE3600, 3640, Upgrade - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 8Ai +/-20 Ma - Motorola</p>\n\n<p>Plug-In, RTU, ACE3600, RS-232 - Motorola</p>\n\n<p>HMI Control Panel - Allen-Bradle, Motorola</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.</p>\n\n<p>Connector, Coaxial, N-Male, Right Angle, Lmr-400 - Times Microwave Sys.</p>\n\n<p>L-Foot, Solar Panel Rail, W/T-Bolt, Mill - Unirac</p>\n\n<p>Panel, 345 Watt, Solar - Mission Solar Energy</p>\n\n<p>Rail, Solar Panel Racking 168-Inch, Clear - Unirac</p>\n\n<p>Connector, Gnd, Lay-In, 4-14, #10, Tin - ILSCO/REXEL</p>\n\n<p>Nut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt - McMaster-Carr</p>\n\n<p>Nut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS - McMaster-Carr</p>\n\n<p>Nut, Hex, Ext Toothed Lk 10-32, 18-8 SS - McMaster-Carr</p>\n\n<p>Plate, Backing, 2-13/16&quot; C-C Spacing - Sterling Industry</p>\n\n<p>Screw, Hex Hd, 1/4-20 X .75, 18-8 SS - McMaster-Carr</p>\n\n<p>Screw, Hex Hd, 3/8-16 X .3, 18-8 SS - McMaster-Carr</p>\n\n<p>Screw, Hex Hd, Serflg,10-32 X .75, 18-8 - McMaster-Carr</p>\n\n<p>Spar, Left, Vert, Solar Panel Bracket - Sterling Industry</p>\n\n<p>Spar, Right, Vert, Solar Panel Bracket - Sterling Industry</p>\n\n<p>U-Bolt,3/8-16, 2-7/16 Id, Galv. Steel - McMaster-Carr</p>\n\n<p>Washer, Flat,1/4, 18-8 SS - McMaster-Carr</p>\n\n<p>Washer, Split, 3/8, 18-8 SS - McMaster-Carr</p>\n\n<p>Weldment, Triangle, Solar Panel Bracket - Sterling Industry</p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Model #8510110 - DBI/SALA</p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Cap Model #8510827 - DBI/SALA</p>\n\n<p>Ladder Tie D-Bolt Anchorage Connector Model 417SS - MILLER</p>\n\n<p>Hilti Hit-Re 500 V3 With 3/4&quot; Has [304 316] 53/4&quot; Embedment - HILTI</p>\n\n<p>Face Mount SS Davit Sleeve DBI/Sala Model #8518348 - DBI/SALA</p>\n\n<p>Stainless Mini Rotary Latch Right Hand - EBERHARD</p>\n\n<p>Gate Hinge Assembly Self Closing - D&amp;D Technologies</p>\n\n<p>Amphenol 90&deg; Connector - Amphenol</p>\n\n<p>3/8&quot;-16 Pem Nut-SS Installed in the Side of Enclosure - PEM</p>\n\n<p>1/4&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM</p>\n\n<p>1/2&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM</p>\n\n<p>Aluminum 1/4&quot; Thick Hinge - McMaster-Carr</p>\n\n<p>Test Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces - CHLOR*RID International Inc.</p>\n\n<p>Test Kit for Identifying Amine Blush on Epoxy Surfaces - Elcometer</p>\n\n<p>Four Pin Disk Tumbler Lock - Illinois Lock Company</p>\n\n<p>Horn - Federal Signal Corporation</p>\n\n<p>4A969 Weatherproof Box - Federal Signal Corporation</p>\n\n<p>Anti-Seize - Bostik</p>\n\n<p>1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor - Sumitomo</p>\n\n<p>Chatsworth Universal Rack W/ Base Insulators - Chatsworth</p>\n\n<p>120VAC Rackmount Power Strip - APC</p>\n\n<p>Fiber Optic Inside Plant Patch Panel - Corning</p>\n\n<p>Scada Switch - Cisco</p>\n\n<p>Scada Switch Wire Management - Chatsworth</p>\n\n<p>Scada Patch Panel 24 Port - Siemon</p>\n\n<p>Enterprise Switch - Cisco</p>\n\n<p>SCADA Patch Panel - Siemon</p>\n\n<p>KVM Rack Mount Console - Tripp Lite</p>\n\n<p>Server 6TB - Salient</p>\n\n<p>CCTV Switch - Fortinet</p>\n\n<p>CCTV TVSS - DITEK</p>\n\n<p>It System Ups - APC</p>\n\n<p>Ess System Ups - APC</p>\n\n<p>Single Mode Fiber Optic Patch Panel - Corning 24 Pair. - Corning</p>\n\n<p>Solara #20033-2, 20033-9, 20033-10 - Solara</p>\n\n<p>Digital Shaft Encoder - Design Analysis Associates</p>\n\n<p>Mounted Pump Cutoff Switches - Jerguson</p>\n\n<p>Ultrasonic Level Sensors - Drexelbrook</p>\n\n<p>Lightning/Surge: Power Supply Line Noise Suppressing Isolation Transformers and Surge Suppressors. - Edco</p>\n\n<p>Lightning/Surge Protection: Analog - Edco</p>\n\n<p>Norton Utilities - Norton</p>\n\n<p>One (1) Dell Timbuk2 16&quot; Carry Case - Dell</p>\n\n<p>Aircable Wireless Serial Connector - Aircable</p>\n\n<p>ATI&#39;s Mobility&reg; Radeon&trade; Hd3670 - 512Mb - ATI</p>\n\n<p>Dell Latitude E6410At6 Or Latest Version - Dell</p>\n\n<p>Microsoft Office (Latest Version) - Microsoft</p>\n\n<p>Dell Wireless 370 Bluetooth Module (2-1 + EDR) - Dell</p>\n\n<p>Rockwell Software&#39;s RSLogix5000 (Newest Version). - Rockwell Software</p>\n\n<p>Pro Soft Modbus Master/Slave Communications Interface Module for Control Logix - Pro Soft</p>\n\n<p>Allen-Bradley Stratix 5700 - Allen-Bradley</p>\n\n<p>Allen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core. - Allen-Bradley</p>\n\n<p>Allen-Bradley PanelView Plus - Allen-Bradley</p>\n\n<p>Hoffman Consolet - Hoffman</p>\n\n<p>Capwap Software - Pile Dynamics, Inc.</p>\n\n<p>Testing Equipment - Pile Dynamics, Inc.</p>\n\n<p>The O-Rings on a Quick Disconnect - Chemours</p>\n\n<p>Simplex Compact Fuel Port - Simplex</p>\n\n<p>Pump Bearings - Thordon</p>\n\n<p>Shaft Couplings - Aquamet</p>\n\n<p>Shafts - Aquamet</p>\n\n<p>Shaft Bearing or Packing Box Sleeves - Aquamet</p>\n\n<p>Epoxy Coating - Chesterton</p>\n\n<p>625kW Tier 4, Diesel Generator - Power Secure</p>\n\n<p></p>\n\n<p>Submission Instructions: Any vendor wishing to provide a system(s) that is compatible with the existing equipment to be considered by the Government as described above must provide a copy of its brochure and any other capability statements/ datano later than May 2, 2025 at 2:00PM, EST.&nbsp; All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.</p>\n\n<p></p>\n\n<p>This is a market survey and notification of intent only. This is not a request to respond to a solicitation. A determination by the Government to compete this proposed contract based upon responses to this notice is solely within the direction of the Government.</p>\n\n<p></p>","text":"Sources Sought Synopsis\n\nW912EP25X161X\n\nCentral Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida\n\nThis announcement is to notify industry about the Government’s intent to incorporate a brand name product requirement in an upcoming construction project. The product is the Supervisory Control and Data Acquisition (SCADA) system. This product is being considered to be included in the specifications to build a seepage pump station. This announcement seeks information from industry and will only be used for preliminary planning purposes. THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. Respondents will not be notified of the results of the evaluation.\n\nThe United States Army Corps of Engineers, Jacksonville District (SAJ) intends to include the following proprietary items in a solicitation for a construction acquisition under authority of FAR 6.302-1(c)(1), only one responsible source and no other supplies or services will satisfy agency requirements. This project may include a Brand Name only component, as described below, unless the results of this sources sought notification indicates otherwise.\n\nThis notification serves three purposes: (1) to notify potential Offerors of the Government's intent to solicit a brand name only component under a future construction project; (2) to identify potential sources that can provide the brand name only item and/or equivalent; (3) notification of USACE’s intent to contract sole source for a Brand Name Only, if the market is unable to provide 'equivalent' products.\n\nIn the event no equivalent equipment exists, the Brand Name Only justification will be issued pursuant to FAR Part 6.302-1(c)(1), \"Only One Responsible Source and no other supplies or services will satisfy agency requirements\". A subsequent market survey will not be published in support of a Justification and Approval (J&A) for sole sourcing the resultant product(s) or system(s) in the event an equivalent product is not submitted for consideration. In such instances, the brand name or equal component will be embedded in the construction project that will be issued/solicited competitively. Only that part of the project requiring brand name components will be sole source if no sources are able to prove an equal product.\n\nThe SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP. These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.\n\nThis is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636. The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.\n\nThe purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.\n\nThe S-636 (CNT11C) Project is designed to perform two primary functions:\n\n• Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)\n\n• Manage and maintain the C-636 (Seepage Canal) within an authorized range.\n\nProject Description:\n\nThe work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.\n\nThe new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.\n\nThe new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.\n\nThe SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:\n\nRemote Terminal Unit Gated Culvert:\n\nEquipment Name Manufacturer\n\nFire Alarm Control Panel - Honeywel\n\nConverter - Honeywell\n\nSecurity Alarm Control Panel - Honeywell\n\nAPC Smart-Ups - APC\n\nTransceiver, Aprisa SR+, UHF, Half-Duplex - 4RF, USA\n\nTransceiver, Aprisa SR+, VHF, Half-Duplex - 4RF, USA\n\nController, 6A, 12VDC, Solar, Charger - Morningstar\n\nCable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.\n\nConnector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific - Times Microwave Sys.\n\nProtector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female - Polyphaser\n\nRadio Modem, Integra-Tr, Site Specific VHF/UHF - CalAmp\n\nCable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF - Pasternack\n\nCable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard - Graybar\n\nBase Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame - Motorola\n\nFrame Option, RTU, ACE3600, 3 I/O Slots - Motorola\n\nI/O Module, RTU, ACE3600, 32 Di Fast 24V - Motorola\n\nI/O Module, RTU, ACE3600, 16 Do Ee Relay 2A - Motorola\n\nPower Supply, RTU, ACE3600, Dc Power Supply 18-72V - Motorola\n\nCPU, RTU, ACE3600, 3640, Upgrade - Motorola\n\nI/O Module, RTU, ACE3600, 8Ai +/-20 Ma - Motorola\n\nPlug-In, RTU, ACE3600, RS-232 - Motorola\n\nHMI Control Panel - Allen-Bradle, Motorola\n\nCable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.\n\nConnector, Coaxial, N-Male, Right Angle, Lmr-400 - Times Microwave Sys.\n\nL-Foot, Solar Panel Rail, W/T-Bolt, Mill - Unirac\n\nPanel, 345 Watt, Solar - Mission Solar Energy\n\nRail, Solar Panel Racking 168-Inch, Clear - Unirac\n\nConnector, Gnd, Lay-In, 4-14, #10, Tin - ILSCO/REXEL\n\nNut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt - McMaster-Carr\n\nNut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS - McMaster-Carr\n\nNut, Hex, Ext Toothed Lk 10-32, 18-8 SS - McMaster-Carr\n\nPlate, Backing, 2-13/16\" C-C Spacing - Sterling Industry\n\nScrew, Hex Hd, 1/4-20 X .75, 18-8 SS - McMaster-Carr\n\nScrew, Hex Hd, 3/8-16 X .3, 18-8 SS - McMaster-Carr\n\nScrew, Hex Hd, Serflg,10-32 X .75, 18-8 - McMaster-Carr\n\nSpar, Left, Vert, Solar Panel Bracket - Sterling Industry\n\nSpar, Right, Vert, Solar Panel Bracket - Sterling Industry\n\nU-Bolt,3/8-16, 2-7/16 Id, Galv. Steel - McMaster-Carr\n\nWasher, Flat,1/4, 18-8 SS - McMaster-Carr\n\nWasher, Split, 3/8, 18-8 SS - McMaster-Carr\n\nWeldment, Triangle, Solar Panel Bracket - Sterling Industry\n\nCore Mount SS Davit Sleeve DBI/Sala Model #8510110 - DBI/SALA\n\nCore Mount SS Davit Sleeve DBI/Sala Cap Model #8510827 - DBI/SALA\n\nLadder Tie D-Bolt Anchorage Connector Model 417SS - MILLER\n\nHilti Hit-Re 500 V3 With 3/4\" Has [304 316] 53/4\" Embedment - HILTI\n\nFace Mount SS Davit Sleeve DBI/Sala Model #8518348 - DBI/SALA\n\nStainless Mini Rotary Latch Right Hand - EBERHARD\n\nGate Hinge Assembly Self Closing - D&D Technologies\n\nAmphenol 90° Connector - Amphenol\n\n3/8\"-16 Pem Nut-SS Installed in the Side of Enclosure - PEM\n\n1/4\" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM\n\n1/2\" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM\n\nAluminum 1/4\" Thick Hinge - McMaster-Carr\n\nTest Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces - CHLOR*RID International Inc.\n\nTest Kit for Identifying Amine Blush on Epoxy Surfaces - Elcometer\n\nFour Pin Disk Tumbler Lock - Illinois Lock Company\n\nHorn - Federal Signal Corporation\n\n4A969 Weatherproof Box - Federal Signal Corporation\n\nAnti-Seize - Bostik\n\n1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor - Sumitomo\n\nChatsworth Universal Rack W/ Base Insulators - Chatsworth\n\n120VAC Rackmount Power Strip - APC\n\nFiber Optic Inside Plant Patch Panel - Corning\n\nScada Switch - Cisco\n\nScada Switch Wire Management - Chatsworth\n\nScada Patch Panel 24 Port - Siemon\n\nEnterprise Switch - Cisco\n\nSCADA Patch Panel - Siemon\n\nKVM Rack Mount Console - Tripp Lite\n\nServer 6TB - Salient\n\nCCTV Switch - Fortinet\n\nCCTV TVSS - DITEK\n\nIt System Ups - APC\n\nEss System Ups - APC\n\nSingle Mode Fiber Optic Patch Panel - Corning 24 Pair. - Corning\n\nSolara #20033-2, 20033-9, 20033-10 - Solara\n\nDigital Shaft Encoder - Design Analysis Associates\n\nMounted Pump Cutoff Switches - Jerguson\n\nUltrasonic Level Sensors - Drexelbrook\n\nLightning/Surge: Power Supply Line Noise Suppressing Isolation Transformers and Surge Suppressors. - Edco\n\nLightning/Surge Protection: Analog - Edco\n\nNorton Utilities - Norton\n\nOne (1) Dell Timbuk2 16\" Carry Case - Dell\n\nAircable Wireless Serial Connector - Aircable\n\nATI's Mobility® Radeon™ Hd3670 - 512Mb - ATI\n\nDell Latitude E6410At6 Or Latest Version - Dell\n\nMicrosoft Office (Latest Version) - Microsoft\n\nDell Wireless 370 Bluetooth Module (2-1 + EDR) - Dell\n\nRockwell Software's RSLogix5000 (Newest Version). - Rockwell Software\n\nPro Soft Modbus Master/Slave Communications Interface Module for Control Logix - Pro Soft\n\nAllen-Bradley Stratix 5700 - Allen-Bradley\n\nAllen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core. - Allen-Bradley\n\nAllen-Bradley PanelView Plus - Allen-Bradley\n\nHoffman Consolet - Hoffman\n\nCapwap Software - Pile Dynamics, Inc.\n\nTesting Equipment - Pile Dynamics, Inc.\n\nThe O-Rings on a Quick Disconnect - Chemours\n\nSimplex Compact Fuel Port - Simplex\n\nPump Bearings - Thordon\n\nShaft Couplings - Aquamet\n\nShafts - Aquamet\n\nShaft Bearing or Packing Box Sleeves - Aquamet\n\nEpoxy Coating - Chesterton\n\n625kW Tier 4, Diesel Generator - Power Secure\n\nSubmission Instructions: Any vendor wishing to provide a system(s) that is compatible with the existing equipment to be considered by the Government as described above must provide a copy of its brochure and any other capability statements/ datano later than May 2, 2025 at 2:00PM, EST. All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.\n\nThis is a market survey and notification of intent only. This is not a request to respond to a solicitation. A determination by the Government to compete this proposed contract based upon responses to this notice is solely within the direction of the Government.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W912EP25X161X","place_of_performance":{"zip":"33493","state":{"code":"FL","name":"Florida"},"country":{"code":"USA","name":"UNITED STATES"}}}],"due_at":"2025-05-02T18:00:00Z","due_date":"2025-05-02","closes_at":"2025-05-02T18:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","state":"FL","county":"12099","county_name":"Palm Beach County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-19T04:12:52.367518Z","principal_notice_id":"e945a2a32b454a1bad36e6dd864f1bb4","description":{"text":"Sources Sought Synopsis\n\nW912EP25X161X\n\nCentral Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida\n\nThis announcement is to notify industry about the Government’s intent to incorporate a brand name product requirement in an upcoming construction project. The product is the Supervisory Control and Data Acquisition (SCADA) system. This product is being considered to be included in the specifications to build a seepage pump station. This announcement seeks information from industry and will only be used for preliminary planning purposes. THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. Respondents will not be notified of the results of the evaluation.\n\nThe United States Army Corps of Engineers, Jacksonville District (SAJ) intends to include the following proprietary items in a solicitation for a construction acquisition under authority of FAR 6.302-1(c)(1), only one responsible source and no other supplies or services will satisfy agency requirements. This project may include a Brand Name only component, as described below, unless the results of this sources sought notification indicates otherwise.\n\nThis notification serves three purposes: (1) to notify potential Offerors of the Government's intent to solicit a brand name only component under a future construction project; (2) to identify potential sources that can provide the brand name only item and/or equivalent; (3) notification of USACE’s intent to contract sole source for a Brand Name Only, if the market is unable to provide 'equivalent' products.\n\nIn the event no equivalent equipment exists, the Brand Name Only justification will be issued pursuant to FAR Part 6.302-1(c)(1), \"Only One Responsible Source and no other supplies or services will satisfy agency requirements\". A subsequent market survey will not be published in support of a Justification and Approval (J&A) for sole sourcing the resultant product(s) or system(s) in the event an equivalent product is not submitted for consideration. In such instances, the brand name or equal component will be embedded in the construction project that will be issued/solicited competitively. Only that part of the project requiring brand name components will be sole source if no sources are able to prove an equal product.\n\nThe SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP. These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.\n\nThis is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636. The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.\n\nThe purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.\n\nThe S-636 (CNT11C) Project is designed to perform two primary functions:\n\n• Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)\n\n• Manage and maintain the C-636 (Seepage Canal) within an authorized range.\n\nProject Description:\n\nThe work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.\n\nThe new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.\n\nThe new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.\n\nThe SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:\n\nRemote Terminal Unit Gated Culvert:\n\nEquipment Name Manufacturer\n\nFire Alarm Control Panel - Honeywel\n\nConverter - Honeywell\n\nSecurity Alarm Control Panel - Honeywell\n\nAPC Smart-Ups - APC\n\nTransceiver, Aprisa SR+, UHF, Half-Duplex - 4RF, USA\n\nTransceiver, Aprisa SR+, VHF, Half-Duplex - 4RF, USA\n\nController, 6A, 12VDC, Solar, Charger - Morningstar\n\nCable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.\n\nConnector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific - Times Microwave Sys.\n\nProtector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female - Polyphaser\n\nRadio Modem, Integra-Tr, Site Specific VHF/UHF - CalAmp\n\nCable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF - Pasternack\n\nCable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard - Graybar\n\nBase Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame - Motorola\n\nFrame Option, RTU, ACE3600, 3 I/O Slots - Motorola\n\nI/O Module, RTU, ACE3600, 32 Di Fast 24V - Motorola\n\nI/O Module, RTU, ACE3600, 16 Do Ee Relay 2A - Motorola\n\nPower Supply, RTU, ACE3600, Dc Power Supply 18-72V - Motorola\n\nCPU, RTU, ACE3600, 3640, Upgrade - Motorola\n\nI/O Module, RTU, ACE3600, 8Ai +/-20 Ma - Motorola\n\nPlug-In, RTU, ACE3600, RS-232 - Motorola\n\nHMI Control Panel - Allen-Bradle, Motorola\n\nCable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.\n\nConnector, Coaxial, N-Male, Right Angle, Lmr-400 - Times Microwave Sys.\n\nL-Foot, Solar Panel Rail, W/T-Bolt, Mill - Unirac\n\nPanel, 345 Watt, Solar - Mission Solar Energy\n\nRail, Solar Panel Racking 168-Inch, Clear - Unirac\n\nConnector, Gnd, Lay-In, 4-14, #10, Tin - ILSCO/REXEL\n\nNut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt - McMaster-Carr\n\nNut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS - McMaster-Carr\n\nNut, Hex, Ext Toothed Lk 10-32, 18-8 SS - McMaster-Carr\n\nPlate, Backing, 2-13/16\" C-C Spacing - Sterling Industry\n\nScrew, Hex Hd, 1/4-20 X .75, 18-8 SS - McMaster-Carr\n\nScrew, Hex Hd, 3/8-16 X .3, 18-8 SS - McMaster-Carr\n\nScrew, Hex Hd, Serflg,10-32 X .75, 18-8 - McMaster-Carr\n\nSpar, Left, Vert, Solar Panel Bracket - Sterling Industry\n\nSpar, Right, Vert, Solar Panel Bracket - Sterling Industry\n\nU-Bolt,3/8-16, 2-7/16 Id, Galv. Steel - McMaster-Carr\n\nWasher, Flat,1/4, 18-8 SS - McMaster-Carr\n\nWasher, Split, 3/8, 18-8 SS - McMaster-Carr\n\nWeldment, Triangle, Solar Panel Bracket - Sterling Industry\n\nCore Mount SS Davit Sleeve DBI/Sala Model #8510110 - DBI/SALA\n\nCore Mount SS Davit Sleeve DBI/Sala Cap Model #8510827 - DBI/SALA\n\nLadder Tie D-Bolt Anchorage Connector Model 417SS - MILLER\n\nHilti Hit-Re 500 V3 With 3/4\" Has [304 316] 53/4\" Embedment - HILTI\n\nFace Mount SS Davit Sleeve DBI/Sala Model #8518348 - DBI/SALA\n\nStainless Mini Rotary Latch Right Hand - EBERHARD\n\nGate Hinge Assembly Self Closing - D&D Technologies\n\nAmphenol 90° Connector - Amphenol\n\n3/8\"-16 Pem Nut-SS Installed in the Side of Enclosure - PEM\n\n1/4\" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM\n\n1/2\" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM\n\nAluminum 1/4\" Thick Hinge - McMaster-Carr\n\nTest Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces - CHLOR*RID International Inc.\n\nTest Kit for Identifying Amine Blush on Epoxy Surfaces - Elcometer\n\nFour Pin Disk Tumbler Lock - Illinois Lock Company\n\nHorn - Federal Signal Corporation\n\n4A969 Weatherproof Box - Federal Signal Corporation\n\nAnti-Seize - Bostik\n\n1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor - Sumitomo\n\nChatsworth Universal Rack W/ Base Insulators - Chatsworth\n\n120VAC Rackmount Power Strip - APC\n\nFiber Optic Inside Plant Patch Panel - Corning\n\nScada Switch - Cisco\n\nScada Switch Wire Management - Chatsworth\n\nScada Patch Panel 24 Port - Siemon\n\nEnterprise Switch - Cisco\n\nSCADA Patch Panel - Siemon\n\nKVM Rack Mount Console - Tripp Lite\n\nServer 6TB - Salient\n\nCCTV Switch - Fortinet\n\nCCTV TVSS - DITEK\n\nIt System Ups - APC\n\nEss System Ups - APC\n\nSingle Mode Fiber Optic Patch Panel - Corning 24 Pair. - Corning\n\nSolara #20033-2, 20033-9, 20033-10 - Solara\n\nDigital Shaft Encoder - Design Analysis Associates\n\nMounted Pump Cutoff Switches - Jerguson\n\nUltrasonic Level Sensors - Drexelbrook\n\nLightning/Surge: Power Supply Line Noise Suppressing Isolation Transformers and Surge Suppressors. - Edco\n\nLightning/Surge Protection: Analog - Edco\n\nNorton Utilities - Norton\n\nOne (1) Dell Timbuk2 16\" Carry Case - Dell\n\nAircable Wireless Serial Connector - Aircable\n\nATI's Mobility® Radeon™ Hd3670 - 512Mb - ATI\n\nDell Latitude E6410At6 Or Latest Version - Dell\n\nMicrosoft Office (Latest Version) - Microsoft\n\nDell Wireless 370 Bluetooth Module (2-1 + EDR) - Dell\n\nRockwell Software's RSLogix5000 (Newest Version). - Rockwell Software\n\nPro Soft Modbus Master/Slave Communications Interface Module for Control Logix - Pro Soft\n\nAllen-Bradley Stratix 5700 - Allen-Bradley\n\nAllen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core. - Allen-Bradley\n\nAllen-Bradley PanelView Plus - Allen-Bradley\n\nHoffman Consolet - Hoffman\n\nCapwap Software - Pile Dynamics, Inc.\n\nTesting Equipment - Pile Dynamics, Inc.\n\nThe O-Rings on a Quick Disconnect - Chemours\n\nSimplex Compact Fuel Port - Simplex\n\nPump Bearings - Thordon\n\nShaft Couplings - Aquamet\n\nShafts - Aquamet\n\nShaft Bearing or Packing Box Sleeves - Aquamet\n\nEpoxy Coating - Chesterton\n\n625kW Tier 4, Diesel Generator - Power Secure\n\nSubmission Instructions: Any vendor wishing to provide a system(s) that is compatible with the existing equipment to be considered by the Government as described above must provide a copy of its brochure and any other capability statements/ datano later than May 2, 2025 at 2:00PM, EST. All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.\n\nThis is a market survey and notification of intent only. This is not a request to respond to a solicitation. A determination by the Government to compete this proposed contract based upon responses to this notice is solely within the direction of the Government.","html":"<p><strong>Sources Sought Synopsis</strong></p>\n\n<p><strong>W912EP25X161X</strong></p>\n\n<p><strong>Central Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida</strong></p>\n\n<p>This announcement is to notify industry about the Government&rsquo;s intent to incorporate a brand name product requirement in an upcoming construction project.&nbsp; The product is the Supervisory Control and Data Acquisition (SCADA) system.&nbsp; This product is being considered to be included in the specifications to build a seepage pump station. &nbsp;This announcement seeks information from industry and will only be used for preliminary planning purposes.&nbsp; THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS.&nbsp; Respondents will not be notified of the results of the evaluation.&nbsp;</p>\n\n<p>The United States Army Corps of Engineers, Jacksonville District (SAJ) intends to include the following proprietary items in a solicitation for a construction acquisition under authority of FAR 6.302-1(c)(1), only one responsible source and no other supplies or services will satisfy agency requirements. This project may include a Brand Name only component, as described below, unless the results of this sources sought notification indicates otherwise.</p>\n\n<p>This notification serves three purposes: (1) to notify potential Offerors of the Government&#39;s intent to solicit a brand name only component under a future construction project; (2) to identify potential sources that can provide the brand name only item and/or equivalent; (3) notification of USACE&rsquo;s intent to contract sole source for a Brand Name Only, if the market is unable to provide &#39;equivalent&#39; products. &nbsp;</p>\n\n<p>In the event no equivalent equipment exists, the Brand Name Only justification will be issued pursuant to FAR Part 6.302-1(c)(1), &quot;Only One Responsible Source and no other supplies or services will satisfy agency requirements&quot;. A subsequent market survey will not be published in support of a Justification and Approval (J&amp;A) for sole sourcing the resultant product(s) or system(s) in the event an equivalent product is not submitted for consideration. In such instances, the brand name or equal component will be embedded in the construction project that will be issued/solicited competitively. Only that part of the project requiring brand name components will be sole source if no sources are able to prove an equal product.</p>\n\n<p>The SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP.&nbsp; These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. &nbsp;It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps.</p>\n\n<p>This is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636.&nbsp; The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products.</p>\n\n<p>The purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations.</p>\n\n<p>The S-636 (CNT11C) Project is designed to perform two primary functions:</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal)</p>\n\n<p>&bull;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Manage and maintain the C-636 (Seepage Canal) within an authorized range.</p>\n\n<p><strong>Project Description:</strong></p>\n\n<p>The work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work.</p>\n\n<p>The new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption.</p>\n\n<p>The new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station.</p>\n\n<p>The SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component:</p>\n\n<p>Remote Terminal Unit Gated Culvert:</p>\n\n<p><strong>Equipment Name Manufacturer</strong></p>\n\n<p>Fire Alarm Control Panel - Honeywel</p>\n\n<p>Converter - Honeywell</p>\n\n<p>Security Alarm Control Panel - Honeywell</p>\n\n<p>APC Smart-Ups - APC</p>\n\n<p>Transceiver, Aprisa SR+, UHF, Half-Duplex - 4RF, USA</p>\n\n<p>Transceiver, Aprisa SR+, VHF, Half-Duplex - 4RF, USA</p>\n\n<p>Controller, 6A, 12VDC, Solar, Charger - Morningstar</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.</p>\n\n<p>Connector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific - Times Microwave Sys.</p>\n\n<p>Protector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female - Polyphaser</p>\n\n<p>Radio Modem, Integra-Tr, Site Specific VHF/UHF - CalAmp</p>\n\n<p>Cable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF - Pasternack</p>\n\n<p>Cable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard - Graybar</p>\n\n<p>Base Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame - Motorola</p>\n\n<p>Frame Option, RTU, ACE3600, 3 I/O Slots - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 32 Di Fast 24V - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 16 Do Ee Relay 2A - Motorola</p>\n\n<p>Power Supply, RTU, ACE3600, Dc Power Supply 18-72V - Motorola</p>\n\n<p>CPU, RTU, ACE3600, 3640, Upgrade - Motorola</p>\n\n<p>I/O Module, RTU, ACE3600, 8Ai +/-20 Ma - Motorola</p>\n\n<p>Plug-In, RTU, ACE3600, RS-232 - Motorola</p>\n\n<p>HMI Control Panel - Allen-Bradle, Motorola</p>\n\n<p>Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys.</p>\n\n<p>Connector, Coaxial, N-Male, Right Angle, Lmr-400 - Times Microwave Sys.</p>\n\n<p>L-Foot, Solar Panel Rail, W/T-Bolt, Mill - Unirac</p>\n\n<p>Panel, 345 Watt, Solar - Mission Solar Energy</p>\n\n<p>Rail, Solar Panel Racking 168-Inch, Clear - Unirac</p>\n\n<p>Connector, Gnd, Lay-In, 4-14, #10, Tin - ILSCO/REXEL</p>\n\n<p>Nut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt - McMaster-Carr</p>\n\n<p>Nut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS - McMaster-Carr</p>\n\n<p>Nut, Hex, Ext Toothed Lk 10-32, 18-8 SS - McMaster-Carr</p>\n\n<p>Plate, Backing, 2-13/16&quot; C-C Spacing - Sterling Industry</p>\n\n<p>Screw, Hex Hd, 1/4-20 X .75, 18-8 SS - McMaster-Carr</p>\n\n<p>Screw, Hex Hd, 3/8-16 X .3, 18-8 SS - McMaster-Carr</p>\n\n<p>Screw, Hex Hd, Serflg,10-32 X .75, 18-8 - McMaster-Carr</p>\n\n<p>Spar, Left, Vert, Solar Panel Bracket - Sterling Industry</p>\n\n<p>Spar, Right, Vert, Solar Panel Bracket - Sterling Industry</p>\n\n<p>U-Bolt,3/8-16, 2-7/16 Id, Galv. Steel - McMaster-Carr</p>\n\n<p>Washer, Flat,1/4, 18-8 SS - McMaster-Carr</p>\n\n<p>Washer, Split, 3/8, 18-8 SS - McMaster-Carr</p>\n\n<p>Weldment, Triangle, Solar Panel Bracket - Sterling Industry</p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Model #8510110 - DBI/SALA</p>\n\n<p>Core Mount SS Davit Sleeve DBI/Sala Cap Model #8510827 - DBI/SALA</p>\n\n<p>Ladder Tie D-Bolt Anchorage Connector Model 417SS - MILLER</p>\n\n<p>Hilti Hit-Re 500 V3 With 3/4&quot; Has [304 316] 53/4&quot; Embedment - HILTI</p>\n\n<p>Face Mount SS Davit Sleeve DBI/Sala Model #8518348 - DBI/SALA</p>\n\n<p>Stainless Mini Rotary Latch Right Hand - EBERHARD</p>\n\n<p>Gate Hinge Assembly Self Closing - D&amp;D Technologies</p>\n\n<p>Amphenol 90&deg; Connector - Amphenol</p>\n\n<p>3/8&quot;-16 Pem Nut-SS Installed in the Side of Enclosure - PEM</p>\n\n<p>1/4&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM</p>\n\n<p>1/2&quot; - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM</p>\n\n<p>Aluminum 1/4&quot; Thick Hinge - McMaster-Carr</p>\n\n<p>Test Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces - CHLOR*RID International Inc.</p>\n\n<p>Test Kit for Identifying Amine Blush on Epoxy Surfaces - Elcometer</p>\n\n<p>Four Pin Disk Tumbler Lock - Illinois Lock Company</p>\n\n<p>Horn - Federal Signal Corporation</p>\n\n<p>4A969 Weatherproof Box - Federal Signal Corporation</p>\n\n<p>Anti-Seize - Bostik</p>\n\n<p>1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor - Sumitomo</p>\n\n<p>Chatsworth Universal Rack W/ Base Insulators - Chatsworth</p>\n\n<p>120VAC Rackmount Power Strip - APC</p>\n\n<p>Fiber Optic Inside Plant Patch Panel - Corning</p>\n\n<p>Scada Switch - Cisco</p>\n\n<p>Scada Switch Wire Management - Chatsworth</p>\n\n<p>Scada Patch Panel 24 Port - Siemon</p>\n\n<p>Enterprise Switch - Cisco</p>\n\n<p>SCADA Patch Panel - Siemon</p>\n\n<p>KVM Rack Mount Console - Tripp Lite</p>\n\n<p>Server 6TB - Salient</p>\n\n<p>CCTV Switch - Fortinet</p>\n\n<p>CCTV TVSS - DITEK</p>\n\n<p>It System Ups - APC</p>\n\n<p>Ess System Ups - APC</p>\n\n<p>Single Mode Fiber Optic Patch Panel - Corning 24 Pair. - Corning</p>\n\n<p>Solara #20033-2, 20033-9, 20033-10 - Solara</p>\n\n<p>Digital Shaft Encoder - Design Analysis Associates</p>\n\n<p>Mounted Pump Cutoff Switches - Jerguson</p>\n\n<p>Ultrasonic Level Sensors - Drexelbrook</p>\n\n<p>Lightning/Surge: Power Supply Line Noise Suppressing Isolation Transformers and Surge Suppressors. - Edco</p>\n\n<p>Lightning/Surge Protection: Analog - Edco</p>\n\n<p>Norton Utilities - Norton</p>\n\n<p>One (1) Dell Timbuk2 16&quot; Carry Case - Dell</p>\n\n<p>Aircable Wireless Serial Connector - Aircable</p>\n\n<p>ATI&#39;s Mobility&reg; Radeon&trade; Hd3670 - 512Mb - ATI</p>\n\n<p>Dell Latitude E6410At6 Or Latest Version - Dell</p>\n\n<p>Microsoft Office (Latest Version) - Microsoft</p>\n\n<p>Dell Wireless 370 Bluetooth Module (2-1 + EDR) - Dell</p>\n\n<p>Rockwell Software&#39;s RSLogix5000 (Newest Version). - Rockwell Software</p>\n\n<p>Pro Soft Modbus Master/Slave Communications Interface Module for Control Logix - Pro Soft</p>\n\n<p>Allen-Bradley Stratix 5700 - Allen-Bradley</p>\n\n<p>Allen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core. - Allen-Bradley</p>\n\n<p>Allen-Bradley PanelView Plus - Allen-Bradley</p>\n\n<p>Hoffman Consolet - Hoffman</p>\n\n<p>Capwap Software - Pile Dynamics, Inc.</p>\n\n<p>Testing Equipment - Pile Dynamics, Inc.</p>\n\n<p>The O-Rings on a Quick Disconnect - Chemours</p>\n\n<p>Simplex Compact Fuel Port - Simplex</p>\n\n<p>Pump Bearings - Thordon</p>\n\n<p>Shaft Couplings - Aquamet</p>\n\n<p>Shafts - Aquamet</p>\n\n<p>Shaft Bearing or Packing Box Sleeves - Aquamet</p>\n\n<p>Epoxy Coating - Chesterton</p>\n\n<p>625kW Tier 4, Diesel Generator - Power Secure</p>\n\n<p></p>\n\n<p>Submission Instructions: Any vendor wishing to provide a system(s) that is compatible with the existing equipment to be considered by the Government as described above must provide a copy of its brochure and any other capability statements/ datano later than May 2, 2025 at 2:00PM, EST.&nbsp; All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil.</p>\n\n<p></p>\n\n<p>This is a market survey and notification of intent only. This is not a request to respond to a solicitation. A determination by the Government to compete this proposed contract based upon responses to this notice is solely within the direction of the Government.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Chad Manson","role":"primary","email":"chad.d.manson@usace.army.mil","phone":"9042323420"},{"name":"Anelis NAZARIO CASTILLO","role":"secondary","email":"anelis.i.nazario-castillo@usace.army.mil","phone":"9042323285"}],"place_of_performance":{"zip":"33493","state":{"code":"FL","name":"Florida"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"32207-0019","city":"JACKSONVILLE","state":"FL","country":"USA"},"naics_codes":["237990"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W912EP27X1CYU","latest_notice_id":"7a5b155148b344c28d9a627d24b0490e","title":"REFRESH SOUTH ATLANTIC DIVISION SMALL BUSINESS REGIONAL INDEFINITE DELIVERY INDEFINITE QUANTITY (IDIQ), MULTIPLE AWARD TASK ORDER CONTRACT (MATOC) FOR MAINTENANCE DREDGING","solicitation_number":"W912EP27X1CYU","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"237990","psc":null,"set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W912EP27Z1CYM","latest_notice_id":"e0ef2878ecef4e8f9801e483891011a3","title":"NOTICE OF INTENT TO SOLICIT FROM A SINGLE SOURCE - Environmental Modeling Technical Support and EEMS Workshop Jacksonville Harbor Deepening Project","solicitation_number":"W912EP27Z1CYM","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":5,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"541620","psc":"B510","set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W912EP27Z1","latest_notice_id":"4791a91fb18f42c7af42abdee0e243ae","title":"Port Everglades USCG Reconfiguration Project","solicitation_number":"W912EP27Z1","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-17","notices":2,"due_at":"2026-12-17T19:00:00Z","due_date":"2026-12-17","closes_at":"2026-12-17T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"236220","psc":"Y1AZ","set_aside":null,"state":"FL","county":"12011","county_name":"Broward County","city":"1224000","city_name":"Fort Lauderdale","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"W912EP27Z1CW6","latest_notice_id":"28bbe35293f346269b569afa69ca53a0","title":"Beach Renourishment, Kennedy Space Center, Brevard County, Florida","solicitation_number":"W912EP27Z1CW6","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-06","notices":6,"due_at":"2026-12-22T22:00:00Z","due_date":"2026-12-22","closes_at":"2026-12-22T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"237990","psc":"Z2KF","set_aside":null,"state":"FL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"BREVARD COUNTY, FLORIDA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"PANSAD27035927","latest_notice_id":"bc9dd4c851c14faf8abbf1e9cece7221","title":"Jacksonville Ship Repairs Requirement","solicitation_number":"PANSAD-27-035927","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2027-01-17T17:00:00Z","due_date":"2027-01-17","closes_at":"2027-01-17T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"336611","psc":"J020","set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open":[{"key":"W912EP27X1CYU","latest_notice_id":"7a5b155148b344c28d9a627d24b0490e","title":"REFRESH SOUTH ATLANTIC DIVISION SMALL BUSINESS REGIONAL INDEFINITE DELIVERY INDEFINITE QUANTITY (IDIQ), MULTIPLE AWARD TASK ORDER CONTRACT (MATOC) FOR MAINTENANCE DREDGING","solicitation_number":"W912EP27X1CYU","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EP","office_name":"W074 ENDIST JACKSNVLLE","naics":"237990","psc":null,"set_aside":null,"state":"FL","county":"12031","county_name":"Duval County","city":"1235000","city_name":"Jacksonville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W9127825RA068","latest_notice_id":"513b27dfcbfd468793603001717412ac","title":"KC-46A ADAL Apron and Hydrant Fueling Pits","solicitation_number":"W9127825RA068","notice_type":"o","first_type":"s","first_posted":"2025-07-16","last_posted":"2026-11-19","notices":14,"due_at":"2026-12-05T20:00:00Z","due_date":"2026-12-05","closes_at":"2026-12-05T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W91278","office_name":"W074 ENDIST MOBILE","naics":"237990","psc":"Z2BD","set_aside":null,"state":"FL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"MACDILL AFB, FL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W912PM27BA003","latest_notice_id":"1fd6a00b1d8c41e888980e050fd14d2e","title":"Jacksonville Harbor Maintenance Dredging","solicitation_number":"W912PM27BA003","notice_type":"o","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-11T18:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PM","office_name":"W074 ENDIST WILMINGTON","naics":"237990","psc":"Z1KF","set_aside":null,"state":"FL","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"LLE HARBOR. JACKSONVILLE HARBOR: THE JACKSONVILLE HARBOR, FL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":143,"indexable":false}