{"canonical":"https://sealedbidder.com/opportunities/w912ef26qa083","key":"W912EF26QA083","url":"https://sealedbidder.com/opportunities/w912ef26qa083","title":"LLA CHECK VALVES","solicitation_number":"W912EF26QA083","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-19T21:00:00Z","first_posted":"2026-07-27","last_posted":"2026-08-14","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"332911","psc":"4820","set_aside":"SBA","place_state":"WA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"53023","place_county_name":"Garfield County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"08f130546e8f4efdafd821cb6a837585","title":"LLA CHECK VALVES","solicitation_number":"W912EF26QA083","notice_type":"o","base_type":"o","posted":"2026-07-27","posted_at":"2026-07-27T13:16:47.598Z","due_at":"2026-08-14T00:00:00Z","due_date":"2026-08-13","cancelled":false,"archived":true,"archive_date":"2026-08-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/08f130546e8f4efdafd821cb6a837585/view","enriched":true,"history":[{"index":3,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T15:13:14.931Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0817fecb84f3471496bfb3263052788d","solicitation_number":"W912EF26QA083","parent_opportunity_id":"08f130546e8f4efdafd821cb6a837585"},{"index":1,"title":"LLA CHECK VALVES","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-27T13:16:47.598Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08f130546e8f4efdafd821cb6a837585","solicitation_number":"W912EF26QA083"}]},{"notice_id":"0817fecb84f3471496bfb3263052788d","title":"LLA CHECK VALVES","solicitation_number":"W912EF26QA083","notice_type":"o","base_type":"o","posted":"2026-08-14","posted_at":"2026-08-14T15:13:14.931Z","due_at":"2026-08-19T21:00:00Z","due_date":"2026-08-19","cancelled":false,"archived":true,"archive_date":"2026-09-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0817fecb84f3471496bfb3263052788d/view","enriched":true,"history":[{"index":6,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-26T17:43:18.250Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"52f1562ed0974d86a42e3cdf4695d679","solicitation_number":"W912EF26PA045","related_opportunity_id":"0817fecb84f3471496bfb3263052788d"},{"index":4,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T15:13:14.931Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0817fecb84f3471496bfb3263052788d","solicitation_number":"W912EF26QA083","parent_opportunity_id":"08f130546e8f4efdafd821cb6a837585"},{"index":1,"title":"LLA CHECK VALVES","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-27T13:16:47.598Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08f130546e8f4efdafd821cb6a837585","solicitation_number":"W912EF26QA083"}]}],"latest_notice_id":"0817fecb84f3471496bfb3263052788d","first_type":"o","notices":[{"dates":{"posted":"2026-07-27","posted_at":"2026-07-27T13:16:47.598Z","created_at":"2026-07-27T13:08:47.181Z","modified_at":"2026-09-03T05:07:22.123Z","response_deadline":{"raw":"2026-08-13T17:00:00-07:00","utc":"2026-08-14T00:00:00Z","date":"2026-08-13","time":"17:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/08f130546e8f4efdafd821cb6a837585/view"},"naics":{"codes":["332911"],"primary":"332911"},"title":"LLA CHECK VALVES","agency":{"office":{"code":"W912EF","name":"US ARMY ENGINEER DISTRICT WALLA WAL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99362-1876","city":"WALLA WALLA","state":"WA","country":"USA"},"organization_id":"100255267","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-28","archive_type":"auto15"},"history":[{"index":3,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T15:13:14.931Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0817fecb84f3471496bfb3263052788d","solicitation_number":"W912EF26QA083","parent_opportunity_id":"08f130546e8f4efdafd821cb6a837585"},{"index":1,"title":"LLA CHECK VALVES","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-27T13:16:47.598Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08f130546e8f4efdafd821cb6a837585","solicitation_number":"W912EF26QA083"}],"contacts":[{"name":"Gregory Moyer","role":"primary","email":"Gregory.Moyer@usace.army.mil","phone":"5095277207"},{"name":"Kristin Hyde","role":"secondary","email":"kristin.a.hernandez@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"08f130546e8f4efdafd821cb6a837585","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"08f130546e8f4efdafd821cb6a837585","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-27T03:55:28.880506524Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"cb132406f4bc741d4cffc38fa29ee495a81b54685523d8fed07d59d96855e3ad","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-27T03:55:28.880506524Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or &quot;gray market&quot; items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.</p>\n\n<p>Technical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100&deg;F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).</p>\n\n<p></p>","text":"This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or \"gray market\" items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.\n\nTechnical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100°F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912EF26QA083","place_of_performance":{"zip":"99347","state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4820"},{"dates":{"posted":"2026-08-14","posted_at":"2026-08-14T15:13:14.931Z","created_at":"2026-08-14T15:04:32.337Z","modified_at":"2026-09-03T05:07:22.123Z","response_deadline":{"raw":"2026-08-19T14:00:00-07:00","utc":"2026-08-19T21:00:00Z","date":"2026-08-19","time":"14:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0817fecb84f3471496bfb3263052788d/view"},"naics":{"codes":["332911"],"primary":"332911"},"title":"LLA CHECK VALVES","agency":{"office":{"code":"W912EF","name":"US ARMY ENGINEER DISTRICT WALLA WAL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99362-1876","city":"WALLA WALLA","state":"WA","country":"USA"},"organization_id":"100255267","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-03","archive_type":"auto15"},"history":[{"index":6,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-26T17:43:18.250Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"52f1562ed0974d86a42e3cdf4695d679","solicitation_number":"W912EF26PA045","related_opportunity_id":"0817fecb84f3471496bfb3263052788d"},{"index":4,"title":"LLA CHECK VALVES","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-14T15:13:14.931Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"0817fecb84f3471496bfb3263052788d","solicitation_number":"W912EF26QA083","parent_opportunity_id":"08f130546e8f4efdafd821cb6a837585"},{"index":1,"title":"LLA CHECK VALVES","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-27T13:16:47.598Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"08f130546e8f4efdafd821cb6a837585","solicitation_number":"W912EF26QA083"}],"contacts":[{"name":"Gregory Moyer","role":"primary","email":"Gregory.Moyer@usace.army.mil","phone":"5095277207"},{"name":"Kristin Hyde","role":"secondary","email":"kristin.a.hernandez@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0817fecb84f3471496bfb3263052788d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"08f130546e8f4efdafd821cb6a837585","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T00:18:55.092692822Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"f5c5f392dd28e407a3eb5c71f0e60357b49f46ac26f4963b985bc4b851bcb6c4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-25T00:18:55.092692822Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or &quot;gray market&quot; items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.</p>\n\n<p>Technical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100&deg;F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).</p>\n\n<p><strong>UPDATED: Solicitation Amendment 0001</strong> - &quot;The purpose of this amendment is to extend the solicitation offer due date from August 13, 2026 at 5PM PDT to August 19, 2026 at 2PM PDT to allow additional time to address technical questions submitted through ProjNet. All other terms and conditions remain unchanged.&quot;</p>\n\n<p></p>","text":"This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or \"gray market\" items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.\n\nTechnical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100°F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).\n\nUPDATED: Solicitation Amendment 0001 - \"The purpose of this amendment is to extend the solicitation offer due date from August 13, 2026 at 5PM PDT to August 19, 2026 at 2PM PDT to allow additional time to address technical questions submitted through ProjNet. All other terms and conditions remain unchanged.\"","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912EF26QA083","place_of_performance":{"zip":"99347","state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4820"}],"due_at":"2026-08-19T21:00:00Z","due_date":"2026-08-19","closes_at":"2026-08-19T21:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","state":"WA","county":"53023","county_name":"Garfield County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-25T00:32:56.537522Z","principal_notice_id":"0817fecb84f3471496bfb3263052788d","description":{"text":"This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or \"gray market\" items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.\n\nTechnical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100°F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).\n\nUPDATED: Solicitation Amendment 0001 - \"The purpose of this amendment is to extend the solicitation offer due date from August 13, 2026 at 5PM PDT to August 19, 2026 at 2PM PDT to allow additional time to address technical questions submitted through ProjNet. All other terms and conditions remain unchanged.\"","html":"<p>This is a solicitation for commercial products, as supplemented with additional information included in this notice. The U.S. Government requires the purchase and delivery of two (2) new, 18-inch Carbon Steel Globe Body Silent Check Valves to Lower Granite Dam. Quotes must be submitted on a firm-fixed-price basis for new equipment only; remanufactured, refurbished, or &quot;gray market&quot; items will not be accepted. The supplied valves must be designed to prevent flow reversal, surge, and water hammer, complying with all applicable ASTM codes and standards.</p>\n\n<p>Technical requirements include a Cast Carbon Steel body (ASTM A216 Grade WCB), 316 Stainless Steel trim/disc (ASTM A351 Grade CF8M), a 302 Stainless Steel spring (ASTM A276), and stainless steel guide pins and bushings. Operational parameters dictate a minimum pressure/temperature rating of 285 PSI at 100&deg;F, ANSI Class 150 integrally cast flanged ends with a 16-hole bolt pattern, a flow capacity of at least 110% of the equivalent pipe size, a cracking pressure of less than 1 PSI, and top-and-bottom guided disc alignment for multi-angle installation. Furthermore, the valves must feature a metal-to-metal hand-lapped drop-tight seal and a permanent corrosion-resistant stainless steel nameplate detailing the manufacturer, model, size, rating, and manufacturing date. Due to strict installation constraints, the following physical dimensions are mandatory with no exceptions allowed: a face-to-face measurement of exactly 22.5 inches, an overall diameter not exceeding 31 inches, a valve weight not exceeding 1,300 lbs, and Class 150 flanges meeting ASTM A105 and ASME B16.5 standards (25-inch outside diameter, 22.75-inch bolt circle diameter, and a 16-hole configuration).</p>\n\n<p><strong>UPDATED: Solicitation Amendment 0001</strong> - &quot;The purpose of this amendment is to extend the solicitation offer due date from August 13, 2026 at 5PM PDT to August 19, 2026 at 2PM PDT to allow additional time to address technical questions submitted through ProjNet. All other terms and conditions remain unchanged.&quot;</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Gregory Moyer","role":"primary","email":"Gregory.Moyer@usace.army.mil","phone":"5095277207"},{"name":"Kristin Hyde","role":"secondary","email":"kristin.a.hernandez@usace.army.mil"}],"place_of_performance":{"zip":"99347","state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"99362-1876","city":"WALLA WALLA","state":"WA","country":"USA"},"naics_codes":["332911"],"award":null,"attachments":[{"resource_id":"2be4d2092d67415d9aae24bcb4f4e05d","name":"Solicitation - W912EF26QA083 Released.pdf","kind":"file","mime_type":".pdf","size_bytes":3345015,"posted_at":"2026-07-27T13:16:47.598Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2be4d2092d67415d9aae24bcb4f4e05d/download","mirrored":false}],"awards":[],"related":[{"key":"W912EF27RSS05","latest_notice_id":"4ec474321d284fddab0804f3d1dda58b","title":"Wicket Gate Locks for Little Goose & Lower Granite Dams","solicitation_number":"W912EF27RSS05","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"332710","psc":"2830","set_aside":null,"state":"WA","county":"53003","county_name":"Asotin County","city":"5312630","city_name":"Clarkston","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W912EF27QA006","latest_notice_id":"7c3b9228948945cbab4a7f0b98539397","title":"LLA Fish Pump - Motor Rewind","solicitation_number":"W912EF27QA006","notice_type":"k","first_type":"k","first_posted":"2026-10-22","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"811310","psc":"J043","set_aside":null,"state":"WA","county":"53023","county_name":"Garfield County","city":"5355120","city_name":"Pomeroy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W912EF27RSS02","latest_notice_id":"757d4f987a464793972064f25e16232c","title":"Mill Creek Section 205 Flood Risk Management Improvements","solicitation_number":"W912EF-27-R-SS02","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":3,"due_at":"2026-12-07T23:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"237990","psc":"Y1PC","set_aside":null,"state":"WA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"MILL CREEK FLOOD CONTROL CHANNELWALLA WALLA, WA 99362WALLA WALLA COUNTY","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"W912EF27BA001","latest_notice_id":"fc507c18cf2a4d029644e5739049d530","title":"Dworshak Powerhouse Roof Replacement","solicitation_number":"W912EF27BA001","notice_type":"o","first_type":"p","first_posted":"2026-09-25","last_posted":"2026-11-24","notices":3,"due_at":"2027-01-04T22:30:00Z","due_date":"2027-01-04","closes_at":"2027-01-04T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"238160","psc":"Z2KA","set_aside":null,"state":"ID","county":"16035","county_name":"Clearwater County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W912EF27RA001","latest_notice_id":"95f19f7196b744beb9bf99128a86a419","title":"Northwest Division Powerhouse Life Safety Upgrades Stage 1","solicitation_number":"W912EF27RA001","notice_type":"p","first_type":"p","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":2,"due_at":"2027-01-08T20:00:00Z","due_date":"2027-01-08","closes_at":"2027-01-08T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"237990","psc":"Z2KA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"multi_state","state_source":null,"state_evidence":"THE PRIMARY AREA OF PERFORMANCE IS ANTICIPATED TO INCLUDE USACE WALLA WALLA DISTRICT PROJECTS AT MCNARY, ICE HARBOR, LOWER MONUMENTAL, LITTLE GOOSE, LOWER GRANI","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"SPE7MC27Q0067","latest_notice_id":"4d490589375b490eb27e10571de45dea","title":"48--VALVE,SAFETY RELIEF","solicitation_number":"SPE7MC27Q0067","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7MC","office_name":"DLA WEAPONS SUPPORT","naics":"332911","psc":"48","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"RELIEF: LINE 0001 QTY 6 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"SPE7MC27Q0055","latest_notice_id":"1db8dbd96e5f4f27872e988f53a4eb97","title":"48--VALVE,GATE","solicitation_number":"SPE7MC27Q0055","notice_type":"k","first_type":"k","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7MC","office_name":"DLA WEAPONS SUPPORT","naics":"332911","psc":"48","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"ATE: LINE 0001 QTY 17 UI EA DELIVER TO: DLA DISTRIBUTION DEPOT OKLAHOMA BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"SPE7M227U0061","latest_notice_id":"912afbfd0280426ba21b09709e241570","title":"48--VALVE,REGULATING,FLUID","solicitation_number":"SPE7M227U0061","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M2","office_name":"DLA WEAPONS SUPPORT","naics":"332911","psc":"48","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"NTITY WILL BE 1. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":237,"indexable":false}