Special notice
Industry Day for Walla Walla District Elevator Maintenance Services
W912EF25RSN06
Department of the Army, US Army Engineer District Walla Wal. Facilities Support Services.
Response deadline
March 11, 2025 at 12:00 PM EDT
Closed 624 days ago. Posted March 13, 2025, first published February 10, 2025. Scheduled to archive March 26, 2025.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2025
38 like it are open now in facilities support services
- FA27 Fall Arrest Inspection Services
Department of the Air Force, FA4620 92 Cons LGC
Sources soughtSmall businessNAICS 561210Fairchild AFB, WAFA462026QA303Due tomorrowNov 26 - R10 Lab: Region 10 Manchester Laboratory Facility
Environmental Protection Agency, Region 7 Contracting Office
SolicitationSDVOSBNAICS 561210Port Orchard, WA68HE0726R0038Closes in 8 daysDec 3 - Fuel Tank Testing
Department of Veterans Affairs, 260-Network Contract Office 20
SolicitationWOSBNAICS 561210Seattle, WA36C26027Q0072Closes in 9 daysDec 4
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Special notice. Industry days, draft requirements, program announcements and other notices that are not a solicitation. Glossary
Description
As published on SAM.gov.
Introduction:
This is a notice for Industry Day to be held on March 11, 2025, between 8:30am – 9:30am Pacific Time (PT) with individual breakout sessions (TBD see below) virtually via Teams. This notice is issued by the United States Army Corps of Engineers (USACE), Walla Walla District, for Elevator Maintenance Services. This notice does not constitute a Request for Proposal, Invitation for Bid, or Request for Quotation, and it is not to be construed as a commitment by the Government to enter into a contract. Furthermore, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with Industry Day attendance or otherwise responding to this notice.
Background and Description
The purpose of the acquisition is to procure elevator maintenance services for six operating projects: Little Goose Lock and Dam, Lower Granite Lock and Dam, Lower Monumental Lock and Dam, McNary Lock and Dam, Ice Harbor Lock and Dam, and Dworshak Dam located throughout Walla Walla District.
The anticipated tasks for this project include, but are not limited to the following:
- Assessment Site Visit - The Contractor should verify site conditions and look for deficiencies and non-compliances to be noted and submitted as a maintenance report.
- Submittals
-
- Certificate(s) of Insurance.
- Certificates showing the current State of Washington or Oregon Elevator Journeyman License, inspection and maintenance of elevators, safety training covering Safe Work Practices, Personal Protective Equipment, Proper House Keeping and Fire Protection.
- The qualifications of each Contractor performing work.
- The name, address and telephone number(s) (not to exceed three) where Contractor’s supervisor can be reached.
- A list of all employees that will be working on this contract.
- Detailed Quality Control Plan and Inspection Checklist.
- In draft form, a Maintenance and Inspection Schedule including any suggested modifications which may be in the interest of practicality, efficiency, economy or effective use of time, including any deficiencies, or items not up to code with elevators inspection schedule.
- List of any non-US citizens requiring access to the Walla Walla District HQ building.
-
- Emergency Egress Procedure – Written procedure for the removal of people from an elevator from a) the elevator stuck at a floor, and b) the elevator stuck between floors. A procedure shall be prepared for each elevator, and the appropriate electrical contacts shall be marked to correlate to the written procedure.
- Maintenance schedules, Maintenance Control Plan (MCP), and Maintenance Inspections.
- Monthly Routine Maintenance as defined in the ASME A17.1 and the Five-Year Full Load Testing and Inspection.
- Nonroutine Maintenance as defined in ASME A17.1 to include repair and replacement and emergency call-out service.
The purpose of the Industry Day is to identify interested and qualified firms capable of providing the elevator maintenance described above at the specified locations. The event will allow attendees to ask questions, voice concerns, and provide feedback to the Government.
Registration for participating in the Industry Day is required. Please see “Registration” below for Instructions.
Registration
To register, please submit requested information below electronically to Victoria Conway at Victoria.l.conway@usace.army.mil no later than 2:00 pm PT, March 3rd, 2025. The email Subject must be marked with your company name followed by “Industry Day, Elevator Maintenance Services.” All documents should be in Microsoft Word Format or Adobe Portable Document Format (PDF).
1. The Cover Sheet should include a non-binding statement of interest and must indicate if your firm intends to participate virtually and must include:
- Company name, address, and Commercial and Government Entity (CAGE) code or Unique Entity Identifier (UEI).
- Name of attendees (limit to four) and contact information for each, including telephone numbers and e-mail addresses.
2. Brief description of the company; years in business; size of company (small business or other than small business for NAICS 561210 – Facilities Support Services); and socioeconomic status.
3. Capability statement and companies are encouraged to provide further details of your firm’s experience with elevator maintenance services.
4. Specify if attending the open forum and/or requesting a one-on-one session.
Agenda for the Industry Day:
8:30am – 9:30am PT, March 11, 2025, via Teams for all attendees:
- USACE Introduction.
- USACE Slide Presentation.
- Questions.
The following times slots are for individual company breakout sessions (one-on-ones). These meetings will be held privately between USACE multi-functional team and interested firms. Please limit the number of company representatives to no more than four attendees to facilitate effective one-on-one dialogues.
Marketing/capability briefings are not authorized during the one-on-one sessions.
If interested, please submit your top three time slots (all time slots are in PT zone) choices with your registration:
- Time slot 1: 9:30am - 10:30am
- Time slot 2: 10:30am – 11:30am
- Time slot 3: 12:30pm– 1:30pm
- Time slot 4: 1:30pm – 2:30pm
- Time slot 5: 2:30pm – 3:30pm
USACE appreciates industry’s collaboration and is looking forward to a meaningful and productive session. If you have questions regarding Industry Day or questions you would like to submit in advance, please provide them to Victoria Conway no later than 2:00 pm PT, March 4, 2025, at the email address noted above.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Industry Day for Walla Walla District Elevator Maintenance Services.pdf98 KB, February 10, 2025
- Industry Day Questions.pdf93 KB, March 13, 2025
- Elevator Industry Day Performance Work Statement 7 March 2025.pdf230 KB, March 13, 2025
- Industry Day Elevator Maintenance Services.pdf2.1 MB, March 13, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 10, 2025
Special notice
Due March 11, 2025 at 12:00 PM EDT. SAM.gov, notice 527ed4e737384f8fb2f6c6bf5d559fc4
2 revisions on SAM
- March 13, 2025: publish, special notice
- February 10, 2025: publish, special notice
March 13, 2025
Special notice
Due March 11, 2025 at 12:00 PM EDT. SAM.gov, notice a061fe72a3014833b92a6062d7e9cd34
2 revisions on SAM
- March 13, 2025: publish, special notice
- February 10, 2025: publish, special notice
Points of contact
- Victoria Conwayvictoria.l.conway@usace.army.mil5095277449