Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,666 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Sources sought

Sources Sought CJD Electric and Hydraulic Elevator Replacement

W912DW24X0ZEP

Department of the Army, W071 Endist Seattle. Other Building Equipment Contractors.

Response deadline

February 23, 2024 at 1:00 PM EST

Closed 1008 days ago. Posted February 15, 2024. Scheduled to archive March 9, 2024.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2024

17 like it are open now in other building equipment contractors

All 17 open in other building equipment contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238290 (other building equipment contractors), means no more than $22 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of February 15, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

This is a SOURCES SOUGHT ANNOUNCEMENT and is for informational and market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS, OR BIDS, NOR A SYNOPSIS OF A PROPOSED CONTRACT ACTION UNDER FAR SUBPART 5.2. The proposed action will be a construction project with a firm-fixed price contract. The type of solicitation to be issued will depend upon information received in response to this sources sought announcement.

No reimbursement will be made for any costs associated with providing information in response to this sources-sought announcement or any follow-up information. Responses to this sources-sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. This is not a request to be placed on a solicitation mailing list and is not to be construed as a commitment by the Government.

The results of this survey will be in effect for a period of one year from the date of this notice. The purpose of this sources sought announcement is to seek potentially qualified Small Business, 8(a), Woman Owned Small Business, Service-Disabled Veteran Owned Small Business, and HUBZone contractor sources; as well as their size classifications relative to the NAICS code 238290, PSC code Y1PZ, and Small Business Size Standard $22M.

Depending upon the responses associated with the business categories listed above, the solicitation will either be set aside in one of those categories or be issued as unrestricted and open to both small and large businesses. After review of the responses to this announcement and if the Government still plans to proceed with this project; a separate solicitation announcement will be published on.Sam.gov. Responses to this announcement are not an adequate response to any future solicitation announcement.

PROJECT DETAILS: Chief Joseph Dam Hydraulic and Electric Elevators Replacement, Bridgeport, Washington. Chief Joseph Dam is located on the Columbia River, 51 river miles downstream from Grand Coulee Dam, near Bridgeport, Washington. The Seattle District is looking for interest and technical information from the contractor community for input and assistance with this critical infrastructure replacement.

WORK SUMMARY: The work includes the scope presented below. Project Description for the Hydraulic Elevator This section is a general summary of the required work and is not all-inclusive. The work described within these specifications include, but not necessarily be limited to the scope listed below. Full replacement of the Hydraulic Elevator.

Installation of a new hydraulic elevator system and equipment to replace the existing, uprating the elevator capacity from 5,000 to 10,000 pounds, and bringing the hydraulic elevator machine room to current code by enclosing the space in a one-hour rated envelope.

Existing features to be demolished include, but are not limited to, the hydraulic pump, the oil heater/cooler, oil reservoir, frequency controller, hoist way cables, hydraulic plunger, elevator car, elevator car safeties, elevator electrical system and wiring including all traveling elevator car power and communications cabling, disconnect switches, motor feeders elevator car lighting and all associated controls including controller cabinets.

The elevator car to be provided with new operating controls, communication devices, new elevator lobby doors and call stations at each floor landing. The existing heavy duty sidewall rails should be reused if possible. The elevator machine room and shaft will be upgraded to meet current code compliance. The upgrade will include any repair needed for the hoist way walls and mechanical ventilation.

Provide smoke detector in machine room that sends elevator to designated floor and provides an alarm signal (light and sounder) to both the Electric Elevator machine room and Control Room fire alarm control panels (FACPs). Project Description for Electric Elevator This section is a general summary of the required work and is not all-inclusive. The work described within these specifications includes, but not necessarily be limited to the scope listed below. Full replacement of the Electric Elevator.

Installation of a new electric elevator system and equipment to replace the existing. Bringing the electric elevator machine room up to code by replacing the wall separating the machine room from the staircase with a two-hour rated wall. Existing features to be demolished include, but are not limited to:

the hoist motor; the hoist gear box, elevator brakes, hoist way ropes, wedge sockets and shackle rods, rope brake, rope deflector sheaves, speed governor, elevator car and counterweights guide rail shoes, elevator car safeties, counterweights and cable compensation chains, oil buffers for the elevator car and counterweights, elevator electrical system and wiring including all traveling elevator car power and communications cabling, disconnect switches, motor feeders elevator car lighting and all associated controls including controller cabinets.

The elevator car to be provided with new operating controls, handrails, communication devices, new elevator lobby doors and call stations at each floor landing. The elevator machine room and shaft will be upgraded to meet current code compliance. The upgrade will include any repair needed for the hoist way walls and HVAC improvements, and elevator hoist way pressurization alternative (in lieu of required enclosed lobbies).

Provide new or replace (as required) smoke detectors in machine room and elevator lobbies that will alarm the FACP and initiate the following actions: Sends elevator to either the designated or alternate level, local alarm (light and sounder) at the FACP, demote alarm (light and sounder, silence-able) at Control Room FACP, elevator hoistway pressurization, stairwell pressurization. A Control Structure fire alarm will signal the Electric Elevator FACP to initiate elevator hoistway pressurization. In general, USACE, Seattle District is looking for qualified firms to complete this work.

NOTE: All dam operations will continue during work under this Contract. Expected magnitude of construction is between $1 million and $5 million.

REQUIREMENTS: Interested firms should submit a capabilities package, to include the following:

1. Firm's name, address, point of contact, phone number, and email address.

2. CAGE code and DUNS number.

3. Firm's interest in bidding on the solicitation if issued.

4. Business classification: Small Business (SB), Small Disadvantaged Business (SDB), Woman Owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service-Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone Small Business (HUBZone), 8(a) Program, Other Than Small Business (Large Business).

5. Firm's joint venture information (if applicable).

6. Bonding information: a. Single bond b. Aggregate All interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and ability to meet all requirements stated above. Prior Government contract work is not required for submitting a response to this announcement. Submit responses to:

Geraldine Kemp, Contract Specialist, via email: Geraldine.L.Kemp@usace.army.mil. Responses should be sent as soon as possible, but not later than 10:00 AM PT, 23 February 2024. All interested firms must be registered in the System for Award Management (www.SAM.gov) and remain active for the duration of the contract to be eligible for Government contracts.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. February 15, 2024

    Sources sought

    Due February 23, 2024 at 1:00 PM EST. SAM.gov, notice 258ab653b528429e9d5d2b3c69b15221

Points of contact