{"canonical":"https://sealedbidder.com/opportunities/w9127n26qa082","key":"W9127N26QA082","url":"https://sealedbidder.com/opportunities/w9127n26qa082","title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","solicitation_number":"W9127N26QA082","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-22T19:00:00Z","first_posted":"2026-05-12","last_posted":"2026-06-05","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W071 ENDIST PORTLAND","naics":"335311","psc":"6150","set_aside":"SBA","place_state":"OR","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"41039","place_county_name":"Lane County","place_city":"4144050","place_city_name":"Lowell","winner":null,"award_amount":null,"publications":[{"notice_id":"c918b4ba3a2a436898c8c2ad31931694","title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","solicitation_number":"W9127N26QA082","notice_type":"r","base_type":"r","posted":"2026-05-12","posted_at":"2026-05-12T17:19:27.081Z","due_at":"2026-05-26T07:00:00Z","due_date":"2026-05-26","cancelled":false,"archived":true,"archive_date":"2026-06-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c918b4ba3a2a436898c8c2ad31931694/view","enriched":true,"history":[{"index":6,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T19:31:44.011Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618","solicitation_number":"W9127N26QA082","related_opportunity_id":"c918b4ba3a2a436898c8c2ad31931694"},{"index":4,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-12T17:19:27.081Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c918b4ba3a2a436898c8c2ad31931694","solicitation_number":"W9127N26QA082"}]},{"notice_id":"d5a4376fc9fa47ceb0bb4551b2800618","title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","solicitation_number":"W9127N26QA082","notice_type":"o","base_type":"r","posted":"2026-06-05","posted_at":"2026-06-05T19:31:44.011Z","due_at":"2026-06-22T19:00:00Z","due_date":"2026-06-22","cancelled":false,"archived":true,"archive_date":"2026-07-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d5a4376fc9fa47ceb0bb4551b2800618/view","enriched":true,"history":[{"index":9,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T16:51:54.619Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1a5fc925323c4d54bf0fa7fe4afcb377","solicitation_number":"W9127N26PA075","related_opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618"},{"index":5,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T19:31:44.011Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618","solicitation_number":"W9127N26QA082","related_opportunity_id":"c918b4ba3a2a436898c8c2ad31931694"},{"index":3,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-12T17:19:27.081Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c918b4ba3a2a436898c8c2ad31931694","solicitation_number":"W9127N26QA082"}]}],"latest_notice_id":"d5a4376fc9fa47ceb0bb4551b2800618","first_type":"r","notices":[{"dates":{"posted":"2026-05-12","posted_at":"2026-05-12T17:19:27.081Z","created_at":"2026-05-12T16:54:12.562Z","modified_at":"2026-06-11T03:55:52.464Z","response_deadline":{"raw":"2026-05-26T00:00:00-07:00","utc":"2026-05-26T07:00:00Z","date":"2026-05-26","time":"00:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c918b4ba3a2a436898c8c2ad31931694/view"},"naics":{"codes":["335311"],"primary":"335311"},"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-10","archive_type":"auto15"},"history":[{"index":6,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T19:31:44.011Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618","solicitation_number":"W9127N26QA082","related_opportunity_id":"c918b4ba3a2a436898c8c2ad31931694"},{"index":4,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-12T17:19:27.081Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c918b4ba3a2a436898c8c2ad31931694","solicitation_number":"W9127N26QA082"}],"contacts":[{"name":"Consuelo Kiser","role":"primary","email":"consuelo.j.kiser@usace.army.mil","phone":"7858067187"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"c918b4ba3a2a436898c8c2ad31931694","lineage_id":"c918b4ba3a2a436898c8c2ad31931694","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-04T03:56:58.136402689Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"993b5b7a131486fc05613ee5312c516d04b569261578f4129f0b76fbec982042","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-04T03:56:58.136402689Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Sources Sought Number: W9127N26QA082</p>\n\n<p>Subject: Sources Sought for Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point.</p>\n\n<p>PSC:&nbsp; 6150 &mdash; Maintenance, Repair, and Rebuilding of Equipment: Transformers.</p>\n\n<p>NAICS: 335311 - Power, Distribution, and Specialty Transformer Manufacturing</p>\n\n<p></p>\n\n<p><strong>General</strong>. This Sources Sought is issued for informational and market research purposes only. It is not a Request for Proposal (RFP), Request for Quotation (RFQ), Invitation for Bid (IFB), or a solicitation under FAR Subpart 5.2.</p>\n\n<p></p>\n\n<p>The purpose of this Sources Sought is to obtain information regarding industry interest, capabilities, and qualifications so the Government can make informed acquisition decisions. We encourage responses from both large and small businesses, including Small Business, Small Disadvantaged Business, 8(a) firms, HUBZone firms, Woman-Owned Small Business (WOSB), Economically Disadvantaged Woman-Owned Small Business (EDWOSB), Service-Disabled Veteran-Owned Small Business (SDVOSB), and Veteran-Owned Small Business (VOSB). All interested parties are strongly encouraged to respond.</p>\n\n<p></p>\n\n<p>Responses to this Sources Sought will be used by the Government to support market research, assess available sources, and inform any future solicitation.</p>\n\n<p></p>\n\n<p>Please provide a capability statement demonstrating your ability to fulfill <strong>ALL</strong> the requirements identified in the Statement of Work (SOW). If you are unable to provide all the requirements, please clearly identify it in your capability statement.</p>\n\n<p></p>\n\n<p>This will help us accurately assess your qualifications for the full requirement.</p>\n\n<p></p>\n\n<p>Formal Sources Sought Response Due:&nbsp;22 May 2026 at 12:00 PM PDT.</p>\n\n<p></p>\n\n<p>The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to replace vacuum interrupters on circuit breaker as defined in this Statement of Work (SOW). The circuit breaker is an Eaton / Cutler Hammer brand, 150VCP-W50C circuit breaker with serial number 03084859.</p>\n\n<p></p>\n\n<p><strong>Scope:</strong></p>\n\n<p>This SOW covers replacement of vacuum interrupters, calibration and testing of one (1) Eaton / Cutler Hammer type VCP-W50C vacuum circuit breaker. Satisfactory completion of this work requires that</p>\n\n<p>refurbishment is conducted either in accordance with the original manufacturer&rsquo;s instructions for replacement, installation, maintenance (I.B. 32-255-1G &ndash; Eaton &quot;Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers&quot;). In strict accordance with the original manufacturer&rsquo;s drawings and other documentation or following ANSI/PEARL electrical equipment reconditioning standards. Acceptable performance of the circuit breaker is also to be verified with testing performed in accordance with NETA Maintenance Testing Specifications (MTS)</p>\n\n<p></p>\n\n<ol>\n\t<li>Please read the SOW and photos in its entirety to ensure a complete understanding of the requirement before responding to this Sources Sought.</li>\n</ol>","text":"Sources Sought Number: W9127N26QA082\n\nSubject: Sources Sought for Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point.\n\nPSC: 6150 — Maintenance, Repair, and Rebuilding of Equipment: Transformers.\n\nNAICS: 335311 - Power, Distribution, and Specialty Transformer Manufacturing\n\nGeneral. This Sources Sought is issued for informational and market research purposes only. It is not a Request for Proposal (RFP), Request for Quotation (RFQ), Invitation for Bid (IFB), or a solicitation under FAR Subpart 5.2.\n\nThe purpose of this Sources Sought is to obtain information regarding industry interest, capabilities, and qualifications so the Government can make informed acquisition decisions. We encourage responses from both large and small businesses, including Small Business, Small Disadvantaged Business, 8(a) firms, HUBZone firms, Woman-Owned Small Business (WOSB), Economically Disadvantaged Woman-Owned Small Business (EDWOSB), Service-Disabled Veteran-Owned Small Business (SDVOSB), and Veteran-Owned Small Business (VOSB). All interested parties are strongly encouraged to respond.\n\nResponses to this Sources Sought will be used by the Government to support market research, assess available sources, and inform any future solicitation.\n\nPlease provide a capability statement demonstrating your ability to fulfill ALL the requirements identified in the Statement of Work (SOW). If you are unable to provide all the requirements, please clearly identify it in your capability statement.\n\nThis will help us accurately assess your qualifications for the full requirement.\n\nFormal Sources Sought Response Due: 22 May 2026 at 12:00 PM PDT.\n\nThe Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to replace vacuum interrupters on circuit breaker as defined in this Statement of Work (SOW). The circuit breaker is an Eaton / Cutler Hammer brand, 150VCP-W50C circuit breaker with serial number 03084859.\n\nScope:\n\nThis SOW covers replacement of vacuum interrupters, calibration and testing of one (1) Eaton / Cutler Hammer type VCP-W50C vacuum circuit breaker. Satisfactory completion of this work requires that\n\nrefurbishment is conducted either in accordance with the original manufacturer’s instructions for replacement, installation, maintenance (I.B. 32-255-1G – Eaton \"Instructions for Installation, Operation and Maintenance of Type VCP-W Vacuum Circuit Breakers\"). In strict accordance with the original manufacturer’s drawings and other documentation or following ANSI/PEARL electrical equipment reconditioning standards. Acceptable performance of the circuit breaker is also to be verified with testing performed in accordance with NETA Maintenance Testing Specifications (MTS)\n\n• Please read the SOW and photos in its entirety to ensure a complete understanding of the requirement before responding to this Sources Sought.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W9127N26QA082","place_of_performance":{"zip":"97452","city":{"code":"44050","name":"Lowell"},"state":{"code":"OR","name":"Oregon"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6150"},{"dates":{"posted":"2026-06-05","posted_at":"2026-06-05T19:31:44.011Z","created_at":"2026-06-05T19:00:14.963Z","modified_at":"2026-07-08T03:55:47.393Z","response_deadline":{"raw":"2026-06-22T12:00:00-07:00","utc":"2026-06-22T19:00:00Z","date":"2026-06-22","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d5a4376fc9fa47ceb0bb4551b2800618/view"},"naics":{"codes":["335311"],"primary":"335311"},"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-07","archive_type":"auto15"},"history":[{"index":9,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T16:51:54.619Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1a5fc925323c4d54bf0fa7fe4afcb377","solicitation_number":"W9127N26PA075","related_opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618"},{"index":5,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T19:31:44.011Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d5a4376fc9fa47ceb0bb4551b2800618","solicitation_number":"W9127N26QA082","related_opportunity_id":"c918b4ba3a2a436898c8c2ad31931694"},{"index":3,"title":"Refurbish Eaton/Cutler Hammer 150VCP-W50C Circuit Breaker for Lookout Point","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-12T17:19:27.081Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c918b4ba3a2a436898c8c2ad31931694","solicitation_number":"W9127N26QA082"}],"contacts":[{"name":"Consuelo Kiser","role":"primary","email":"consuelo.j.kiser@usace.army.mil","phone":"7858067187"},{"name":"Darrell Hutchens","role":"secondary","email":"darrell.d.hutchens@usace.army.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"d5a4376fc9fa47ceb0bb4551b2800618","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"c918b4ba3a2a436898c8c2ad31931694","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T16:09:02.005649019Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"19b192466d5ccbbc5a8183a3410e363f451a0f224802956c619229b3aeec983a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T16:09:02.005649019Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p class=\"sam-rich-text-editor-indent-c\"><strong>One (1) Eaton / Cutler Hammer 150VCP-W50C &ndash;</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"><strong>Circuit Breaker in need of refurbishment.</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"><strong>Willamette Valley Project, at the Lookout Point Dam</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"></p>\n\n<p><strong>General Information</strong>: This effort is to include all associated characteristic required and described in the statement of work and Drawing.</p>\n\n<p><strong>1</strong>. This is a solicitation for commercial supplies prepared in accordance with the format in the Revolutionary&nbsp;&nbsp; RFO 12.201-1 - Simplified Acquisition Procedures, and additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.</p>\n\n<p>Solicitation W9127N26QA082 is a Request for Quotation (RFQ) for a firm-fixed-price supply contract to refurbish one Eaton 150VCP-W50C vacuum circuit breaker in accordance with the requirements outlined in the Statement of Work (SOW).</p>\n\n<p>Please review this solicitation in its entirety including all solicitation attachments provided herein and submit an offer for the requested services as outlined in Attachment 1 - 150VCP-W50C Breaker &ndash; SOW and Attachment 2 - 50VCP-W50C Breaker &ndash; Photos</p>\n\n<p>Description: The Government requests pricing, and O&amp;M literature for the following item.</p>\n\n<p>CLIN &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Description &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; UoM&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; QTY</p>\n\n<p>0001 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 150kW Diesel Generator Set&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; 1</p>\n\n<p>0002 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Shipping of the Eaton CB &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;1</p>\n\n<p></p>\n\n<p><strong>Instructions:</strong></p>\n\n<p>52.212-1 - INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS (MAR 2023) - ADDENDUM</p>\n\n<p>Proposals shall include the following:</p>\n\n<p>a. UEI Number</p>\n\n<p>b. Cage Code</p>\n\n<p>c. Contractor Name</p>\n\n<p>d. Payment Term (net30) or Discount</p>\n\n<p>e. Point of Contact &amp; Phone #</p>\n\n<p>f. Email Address</p>\n\n<p>g. Date Offer Expires</p>\n\n<p>h. Lead time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>i. Spec sheets/information brochures for the items quoted in your package. <strong>Information should clearly show and demonstrate your company&#39;s ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.</strong></p>\n\n<p>Offerors must complete and sign the solicitation in Blocks 17, 30A, 30B, and 30C of the SF 1449 and complete the CLIN section.</p>\n\n<p>If any amendments have been issued, they must be signed, revised as required, and included in the quote package.</p>\n\n<p>Offerors shall submit quotes via email; oral offers will not be accepted.</p>\n\n<p>(i). Technical capability of the item offered to meet the Government requirement. Your quote package MUST include spec sheets/information brochures for the services quoted in your package. Information should clearly show and demonstrate your company&#39;s ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.</p>\n\n<p>Offerors shall submit quotes via email; oral offers will not be accepted.</p>\n\n<p><strong>Questions:</strong> Any questions generated from this solicitation must be submitted to consuelo.j.kiser@usace.army.mil by 12 June 2026 by 2:00 PM Pacific Time (PT). When addressing questions concerning any aspect of the solicitation, state the page number, section, and paragraph that requires clarification. The Contracting Officer will provide clarification(s) through amendment(s) to the solicitation following receipt of any questions.</p>\n\n<p><strong>Submissions</strong>: Quotes are due no later than 22 June 2026, at 12:00 PM PST. Offerors are responsible for verifying receipt of their quotes to this office before the offer due date and time. Facsimile (Fax) responses are not accepted. If you have any questions or concerns, you may contact Consuelo Kiser by email at consuelo.j.kiser@usace.army.mil.&nbsp; No late submissions will be accepted.</p>\n\n<p></p>","text":"One (1) Eaton / Cutler Hammer 150VCP-W50C –\n\nCircuit Breaker in need of refurbishment.\n\nWillamette Valley Project, at the Lookout Point Dam\n\nGeneral Information: This effort is to include all associated characteristic required and described in the statement of work and Drawing.\n\n1. This is a solicitation for commercial supplies prepared in accordance with the format in the Revolutionary RFO 12.201-1 - Simplified Acquisition Procedures, and additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.\n\nSolicitation W9127N26QA082 is a Request for Quotation (RFQ) for a firm-fixed-price supply contract to refurbish one Eaton 150VCP-W50C vacuum circuit breaker in accordance with the requirements outlined in the Statement of Work (SOW).\n\nPlease review this solicitation in its entirety including all solicitation attachments provided herein and submit an offer for the requested services as outlined in Attachment 1 - 150VCP-W50C Breaker – SOW and Attachment 2 - 50VCP-W50C Breaker – Photos\n\nDescription: The Government requests pricing, and O&M literature for the following item.\n\nCLIN Description UoM QTY\n\n0001 150kW Diesel Generator Set EA 1\n\n0002 Shipping of the Eaton CB EA 1\n\nInstructions:\n\n52.212-1 - INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS (MAR 2023) - ADDENDUM\n\nProposals shall include the following:\n\na. UEI Number\n\nb. Cage Code\n\nc. Contractor Name\n\nd. Payment Term (net30) or Discount\n\ne. Point of Contact & Phone #\n\nf. Email Address\n\ng. Date Offer Expires\n\nh. Lead time\n\ni. Spec sheets/information brochures for the items quoted in your package. Information should clearly show and demonstrate your company's ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.\n\nOfferors must complete and sign the solicitation in Blocks 17, 30A, 30B, and 30C of the SF 1449 and complete the CLIN section.\n\nIf any amendments have been issued, they must be signed, revised as required, and included in the quote package.\n\nOfferors shall submit quotes via email; oral offers will not be accepted.\n\n(i). Technical capability of the item offered to meet the Government requirement. Your quote package MUST include spec sheets/information brochures for the services quoted in your package. Information should clearly show and demonstrate your company's ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.\n\nOfferors shall submit quotes via email; oral offers will not be accepted.\n\nQuestions: Any questions generated from this solicitation must be submitted to consuelo.j.kiser@usace.army.mil by 12 June 2026 by 2:00 PM Pacific Time (PT). When addressing questions concerning any aspect of the solicitation, state the page number, section, and paragraph that requires clarification. The Contracting Officer will provide clarification(s) through amendment(s) to the solicitation following receipt of any questions.\n\nSubmissions: Quotes are due no later than 22 June 2026, at 12:00 PM PST. Offerors are responsible for verifying receipt of their quotes to this office before the offer due date and time. Facsimile (Fax) responses are not accepted. If you have any questions or concerns, you may contact Consuelo Kiser by email at consuelo.j.kiser@usace.army.mil. No late submissions will be accepted.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W9127N26QA082","place_of_performance":{"zip":"97452","city":{"code":"44050","name":"Lowell"},"state":{"code":"OR","name":"Oregon"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6150"}],"due_at":"2026-06-22T19:00:00Z","due_date":"2026-06-22","closes_at":"2026-06-22T19:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","state":"OR","county":"41039","county_name":"Lane County","city":"4144050","city_name":"Lowell","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T16:43:52.480627Z","principal_notice_id":"d5a4376fc9fa47ceb0bb4551b2800618","description":{"text":"One (1) Eaton / Cutler Hammer 150VCP-W50C –\n\nCircuit Breaker in need of refurbishment.\n\nWillamette Valley Project, at the Lookout Point Dam\n\nGeneral Information: This effort is to include all associated characteristic required and described in the statement of work and Drawing.\n\n1. This is a solicitation for commercial supplies prepared in accordance with the format in the Revolutionary RFO 12.201-1 - Simplified Acquisition Procedures, and additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.\n\nSolicitation W9127N26QA082 is a Request for Quotation (RFQ) for a firm-fixed-price supply contract to refurbish one Eaton 150VCP-W50C vacuum circuit breaker in accordance with the requirements outlined in the Statement of Work (SOW).\n\nPlease review this solicitation in its entirety including all solicitation attachments provided herein and submit an offer for the requested services as outlined in Attachment 1 - 150VCP-W50C Breaker – SOW and Attachment 2 - 50VCP-W50C Breaker – Photos\n\nDescription: The Government requests pricing, and O&M literature for the following item.\n\nCLIN Description UoM QTY\n\n0001 150kW Diesel Generator Set EA 1\n\n0002 Shipping of the Eaton CB EA 1\n\nInstructions:\n\n52.212-1 - INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS (MAR 2023) - ADDENDUM\n\nProposals shall include the following:\n\na. UEI Number\n\nb. Cage Code\n\nc. Contractor Name\n\nd. Payment Term (net30) or Discount\n\ne. Point of Contact & Phone #\n\nf. Email Address\n\ng. Date Offer Expires\n\nh. Lead time\n\ni. Spec sheets/information brochures for the items quoted in your package. Information should clearly show and demonstrate your company's ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.\n\nOfferors must complete and sign the solicitation in Blocks 17, 30A, 30B, and 30C of the SF 1449 and complete the CLIN section.\n\nIf any amendments have been issued, they must be signed, revised as required, and included in the quote package.\n\nOfferors shall submit quotes via email; oral offers will not be accepted.\n\n(i). Technical capability of the item offered to meet the Government requirement. Your quote package MUST include spec sheets/information brochures for the services quoted in your package. Information should clearly show and demonstrate your company's ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.\n\nOfferors shall submit quotes via email; oral offers will not be accepted.\n\nQuestions: Any questions generated from this solicitation must be submitted to consuelo.j.kiser@usace.army.mil by 12 June 2026 by 2:00 PM Pacific Time (PT). When addressing questions concerning any aspect of the solicitation, state the page number, section, and paragraph that requires clarification. The Contracting Officer will provide clarification(s) through amendment(s) to the solicitation following receipt of any questions.\n\nSubmissions: Quotes are due no later than 22 June 2026, at 12:00 PM PST. Offerors are responsible for verifying receipt of their quotes to this office before the offer due date and time. Facsimile (Fax) responses are not accepted. If you have any questions or concerns, you may contact Consuelo Kiser by email at consuelo.j.kiser@usace.army.mil. No late submissions will be accepted.","html":"<p class=\"sam-rich-text-editor-indent-c\"><strong>One (1) Eaton / Cutler Hammer 150VCP-W50C &ndash;</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"><strong>Circuit Breaker in need of refurbishment.</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"><strong>Willamette Valley Project, at the Lookout Point Dam</strong></p>\n\n<p class=\"sam-rich-text-editor-indent-c\"></p>\n\n<p><strong>General Information</strong>: This effort is to include all associated characteristic required and described in the statement of work and Drawing.</p>\n\n<p><strong>1</strong>. This is a solicitation for commercial supplies prepared in accordance with the format in the Revolutionary&nbsp;&nbsp; RFO 12.201-1 - Simplified Acquisition Procedures, and additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.</p>\n\n<p>Solicitation W9127N26QA082 is a Request for Quotation (RFQ) for a firm-fixed-price supply contract to refurbish one Eaton 150VCP-W50C vacuum circuit breaker in accordance with the requirements outlined in the Statement of Work (SOW).</p>\n\n<p>Please review this solicitation in its entirety including all solicitation attachments provided herein and submit an offer for the requested services as outlined in Attachment 1 - 150VCP-W50C Breaker &ndash; SOW and Attachment 2 - 50VCP-W50C Breaker &ndash; Photos</p>\n\n<p>Description: The Government requests pricing, and O&amp;M literature for the following item.</p>\n\n<p>CLIN &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Description &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; UoM&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; QTY</p>\n\n<p>0001 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 150kW Diesel Generator Set&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; 1</p>\n\n<p>0002 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Shipping of the Eaton CB &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;EA&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;1</p>\n\n<p></p>\n\n<p><strong>Instructions:</strong></p>\n\n<p>52.212-1 - INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS (MAR 2023) - ADDENDUM</p>\n\n<p>Proposals shall include the following:</p>\n\n<p>a. UEI Number</p>\n\n<p>b. Cage Code</p>\n\n<p>c. Contractor Name</p>\n\n<p>d. Payment Term (net30) or Discount</p>\n\n<p>e. Point of Contact &amp; Phone #</p>\n\n<p>f. Email Address</p>\n\n<p>g. Date Offer Expires</p>\n\n<p>h. Lead time&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>i. Spec sheets/information brochures for the items quoted in your package. <strong>Information should clearly show and demonstrate your company&#39;s ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.</strong></p>\n\n<p>Offerors must complete and sign the solicitation in Blocks 17, 30A, 30B, and 30C of the SF 1449 and complete the CLIN section.</p>\n\n<p>If any amendments have been issued, they must be signed, revised as required, and included in the quote package.</p>\n\n<p>Offerors shall submit quotes via email; oral offers will not be accepted.</p>\n\n<p>(i). Technical capability of the item offered to meet the Government requirement. Your quote package MUST include spec sheets/information brochures for the services quoted in your package. Information should clearly show and demonstrate your company&#39;s ability to meet the stated requirement. Failure to provide enough information will result in a determination of quote being unresponsive to the solicitation.</p>\n\n<p>Offerors shall submit quotes via email; oral offers will not be accepted.</p>\n\n<p><strong>Questions:</strong> Any questions generated from this solicitation must be submitted to consuelo.j.kiser@usace.army.mil by 12 June 2026 by 2:00 PM Pacific Time (PT). When addressing questions concerning any aspect of the solicitation, state the page number, section, and paragraph that requires clarification. The Contracting Officer will provide clarification(s) through amendment(s) to the solicitation following receipt of any questions.</p>\n\n<p><strong>Submissions</strong>: Quotes are due no later than 22 June 2026, at 12:00 PM PST. Offerors are responsible for verifying receipt of their quotes to this office before the offer due date and time. Facsimile (Fax) responses are not accepted. If you have any questions or concerns, you may contact Consuelo Kiser by email at consuelo.j.kiser@usace.army.mil.&nbsp; No late submissions will be accepted.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Consuelo Kiser","role":"primary","email":"consuelo.j.kiser@usace.army.mil","phone":"7858067187"},{"name":"Darrell Hutchens","role":"secondary","email":"darrell.d.hutchens@usace.army.mil"}],"place_of_performance":{"zip":"97452","city":{"code":"44050","name":"Lowell"},"state":{"code":"OR","name":"Oregon"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"naics_codes":["335311"],"award":null,"attachments":[{"resource_id":"fc118a5707314a77a688c99995f1f12b","name":"Attachment 2 - 50VCP-W50C Breaker - Photos.pdf","kind":"file","mime_type":".pdf","size_bytes":20274666,"posted_at":"2026-06-05T19:31:44.011Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fc118a5707314a77a688c99995f1f12b/download","mirrored":false},{"resource_id":"745f47098b9f4fb99c0da64ed24a575c","name":"Refurbish 150VCP-W50C Breaker - Photos.pdf","kind":"file","mime_type":".pdf","size_bytes":20274666,"posted_at":"2026-05-12T17:19:27.081Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/745f47098b9f4fb99c0da64ed24a575c/download","mirrored":false}],"awards":[],"related":[{"key":"W9127N27BA010","latest_notice_id":"723dc12e080347459dfcbb8a904dc91f","title":"NAVIGATION LOCK TAINTER VALVE (TV) REPAIR, TV1","solicitation_number":"W9127N27BA010","notice_type":"o","first_type":"o","first_posted":"2026-10-27","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"237990","psc":"Z2KA","set_aside":null,"state":"WA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"THE DALLES DAM (WASHINGTON SIDE), LYLE, WA 98635.","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W9127N27BA009","latest_notice_id":"269d886934d84e78b1dfee2a32db9e67","title":"JOHN DAY DAM NAVIGATION LOCK TAINTER VALVE (TV) REPAIRS TV3 AND TV4","solicitation_number":"W9127N27BA009","notice_type":"o","first_type":"o","first_posted":"2026-10-20","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"237990","psc":"Z2KA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"multi_state","state_source":null,"state_evidence":"LOCATION AND ACCESS DETAILS. OREGON SIDE PHYSICAL ACCESS, NEAR RUFUS, OR 97050 ACCESSIBLE VIA I-84, EXIT 109. WASHINGTON SIDE (CLOSEST TOWN), GOLDENDALE, WA 986","site":"John Day Dam","site_key":"john-day-dam-or","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"W9127N27B1CXI","latest_notice_id":"0adf5ef68ed646e0b66ab6bfe9f00284","title":"USACE Portland District Dredges Slops Services","solicitation_number":"W9127N27B1CXI","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"562998","psc":"S222","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"W9127N27QA010","latest_notice_id":"4d3d53a2977242c688a7e1b7ad4ba189","title":"Hydropower Technical Research & Knowledge Exchange","solicitation_number":"W9127N27QA010","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"541990","psc":"R425","set_aside":null,"state":"CT","county":null,"county_name":null,"city":"0961870","city_name":"Portland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"W9127N27BA011","latest_notice_id":"991857b7284b475b909708630c17b116","title":"JOHN DAY DAM UNIT 10 PACKING BOX REPLACEMENT","solicitation_number":"W9127N27BA011","notice_type":"o","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-10-21","notices":2,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"237990","psc":"Z2KA","set_aside":null,"state":"OR","county":"41055","county_name":"Sherman County","city":"4164200","city_name":"Rufus","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"John Day Dam","site_key":"john-day-dam-or","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open":[{"key":"SPRPA127QVA05","latest_notice_id":"f3bde6b5580d4dbead00d33fc462c395","title":"DISTRIBUTING SYSTEM","solicitation_number":"SPRPA127QVA05","notice_type":"o","first_type":"o","first_posted":"2026-10-20","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-25T20:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRPA1","office_name":"DLA AVIATION AT PHILADELPHIA, PA","naics":"335311","psc":"6150","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6150)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"SPE4A627T113S","latest_notice_id":"22f927190abf4cfdbee02437585f8021","title":"61--CABLE ASSEMBLY,SPEC","solicitation_number":"SPE4A627T113S","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A6","office_name":"DLA AVIATION","naics":"335311","psc":"61","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":",SPEC: LINE 0001 QTY 30 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"SPRPA127QYA43","latest_notice_id":"12ba5124e1d24697b4608bba06c0f4c9","title":"POWER SUPPLY","solicitation_number":"SPRPA127QYA43","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRPA1","office_name":"DLA AVIATION AT PHILADELPHIA, PA","naics":"335311","psc":"6120","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6120)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":63,"indexable":false}