Sources sought
St. Mary’s Falls Canal Concrete Supply, MI
W911XK24X109T
Department of the Army, W072 Endist Detroit. Construction Sand and Gravel Mining.
Response deadline
June 4, 2024 at 2:00 PM EDT
Closed 905 days ago. Posted May 21, 2024. Scheduled to archive June 19, 2024.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2024
4 like it are open now in construction sand and gravel mining
- CD | 884 | Black Hills | Sources Sought Aggregates Supply
Department of Veterans Affairs, National Cemetery Admin
Sources soughtNAICS 212321Ship to Sturgis, SD36C78627Q0038Due tomorrowNov 27 - 2027 RFO COMANCHE OXBOW TRAIL MATERIAL
Departmental Offices, BLM Contracting Activity
Combined synopsis and solicitationSmall businessNAICS 212321Ship to Roswell, NM140LL027Q0024Closes in 11 daysDec 7 - Bushy Knoll Pit Crush & Stockpile
Forest Service, Usda-Fs, Csa Southwest 7
Combined synopsis and solicitationSmall businessNAICS 212321Arizona127EAX27Q0017Closes in 41 daysJan 6, 2027
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 212321 (construction sand and gravel mining), means no more than 500 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of May 21, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The U.S. Army Corps of Engineers, Detroit District intends to solicit for supplies and services to establish a Multiple Blanket Purchase Agreements (BPA) for Concrete Repairs. This is NOT a Request for Proposal (RFP), is Not an Invitation for Bid (IFB) nor the Solicitation. No proposal is being requested or accepted with the Sources Sought Notice, and no reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow up information requests. The work includes the following:
The United States Army Corps of Engineers (USACE) Detroit District (LRE) requires the supply of Portland Cement Concrete (PCC) for various maintenance activities at the St. Mary’s Falls Canal, colloquially known as the Soo Locks, in Sault Sainte Marie, Michigan. Additional areas under the Soo Project Office’s (SPO) area of responsibility may be included as well, to be specified at the time of each BPA call.
If you are interested, please review the SAM posting, complete the attached questionnaire, and send it back to the identified POC of this notice. Your responses will help us determine what type of set-aside we will use for this project. If you are not interested, please provide some feedback as to why (location, value, bonding, etc.) as your answers in the negative do assist us in our market research efforts.
Data collected from the responses will become the property of the USACE and will be used to provide a snapshot of how businesses who participated are capable of providing service to support the construction of the St. Mary’s Falls Canal. The estimate magnitude of construction is between $1,000,000 and $5,000,000.
The North American Industry Classification System (NAICS) code is 212321, Construction Sand and Gravel Mining, which has small business size standard in in number of employees 500. Participation in the questionnaire is entirely voluntary and non-participation will not affect the consideration of any company for future federal contracts. Materials will be delivered to:
St Mary's Falls Canal, 119 E Water St, Sault Ste. Marie, MI 49783 Reference Specification will include:
Portland cement concrete shall comply with the following specifications:
ASTM C94:
Standard Specification for Ready-Mix Concrete ASTM C150: Standard Specification for Portland Cement Concrete shall be supplied by a plant certified by the National Ready Mix Concrete Association. Concrete ordered during times of cold weather shall be heated in accordance with ACI 306R-10 Section 5 to ensure a minimum delivered temperature of 55°F. Specifics of mix design will be established at the time of each call under this contract. The minimum specs are as follows:
Cement: ASTM C150 Type I or Type II Minimum Strength: 3500 PSI at 28 days Max Aggregate Size: 1-1/2 inches Air Content: 5 ± 1% Maximum Slump: 5 inches
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 21, 2024
Sources sought
Due June 4, 2024 at 2:00 PM EDT. SAM.gov, notice 6ee0c5b4b4e44935a69ceea6a9a05153
Points of contact
- Frederick Coffeyfrederick.coffey@usace.army.mil
- Stephanie CraigSTEPHANIE.M.CRAIG@USACE.ARMY.MIL