{"canonical":"https://sealedbidder.com/opportunities/w911s626qa011","key":"W911S626QA011","url":"https://sealedbidder.com/opportunities/w911s626qa011","title":"Safety Air Monitoring and Analytical Referee Systems (SAMARS) Phase III Gas Chromatograph (GC)","solicitation_number":"W911S6-26-Q-A011","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-31T16:00:00Z","first_posted":"2026-03-24","last_posted":"2026-04-20","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-DUGWAY PROV GRD","naics":"334516","psc":"6630","set_aside":null,"place_state":"UT","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"49045","place_county_name":"Tooele County","place_city":"4920450","place_city_name":"Dugway","winner":"TELEDYNE INSTRUMENTS INC","award_amount":"259488.00","publications":[{"notice_id":"be3da5dd8b324349a1765ea5e1d2079e","title":"Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III","solicitation_number":"W911S6-26-Q-A011","notice_type":"k","base_type":"k","posted":"2026-03-24","posted_at":"2026-03-24T20:53:20.862Z","due_at":"2026-03-31T16:00:00Z","due_date":"2026-03-31","cancelled":false,"archived":true,"archive_date":"2026-04-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/be3da5dd8b324349a1765ea5e1d2079e/view","enriched":true,"history":[{"index":3,"title":"Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-24T20:53:20.862Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"be3da5dd8b324349a1765ea5e1d2079e","solicitation_number":"W911S6-26-Q-A011"}]},{"notice_id":"b02cd1e2d7094e2ca724734711346f94","title":"Safety Air Monitoring and Analytical Referee Systems (SAMARS) Phase III Gas Chromatograph (GC)","solicitation_number":"W911S626PA004","notice_type":"a","base_type":"a","posted":"2026-04-20","posted_at":"2026-04-20T19:59:28.510Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-04-22","removed_at":null,"award_number":"W911S626PA004","awardee_name":"TELEDYNE INSTRUMENTS INC","amount":"259488.00","link_sam":"https://sam.gov/workspace/contract/opp/b02cd1e2d7094e2ca724734711346f94/view","enriched":true,"history":[{"index":3,"title":"Safety Air Monitoring and Analytical Referee Systems (SAMARS) Phase III Gas Chromatograph (GC)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T19:59:28.510Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"b02cd1e2d7094e2ca724734711346f94","solicitation_number":"W911S626PA004"}]}],"latest_notice_id":"b02cd1e2d7094e2ca724734711346f94","first_type":"k","notices":[{"dates":{"posted":"2026-03-24","posted_at":"2026-03-24T20:53:20.862Z","created_at":"2026-03-24T19:31:15.903Z","modified_at":"2026-04-16T03:55:45.936Z","response_deadline":{"raw":"2026-03-31T10:00:00-06:00","utc":"2026-03-31T16:00:00Z","date":"2026-03-31","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/be3da5dd8b324349a1765ea5e1d2079e/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III","agency":{"office":{"code":"W911S6","name":"W6QM MICC-DUGWAY PROV GRD"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"84022-5000","city":"DUGWAY","state":"UT","country":"USA"},"organization_id":"500036820","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-15","archive_type":"auto15"},"history":[{"index":3,"title":"Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-24T20:53:20.862Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"be3da5dd8b324349a1765ea5e1d2079e","solicitation_number":"W911S6-26-Q-A011"}],"contacts":[{"name":"Nneka Okeke-Stubbs","role":"primary","email":"nneka.okeke-stubbs.civ@army.mil","phone":"4358312748"},{"name":"Amy Eilerts","role":"secondary","email":"amy.m.eilerts.civ@army.mil","phone":"4358312103"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"be3da5dd8b324349a1765ea5e1d2079e","lineage_id":"be3da5dd8b324349a1765ea5e1d2079e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T02:50:19.184441358Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"8f7b55afcdfba616eb8a10bd918b0d8e2143daf4dac7f605ba8d46e3201304ab","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-10T02:50:19.184441358Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.</p>\n\n<p>Procure one GC instrument with the following specifications:&nbsp; &nbsp; &nbsp; &nbsp; <strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</strong></p>\n\n<ul>\n\t<li>Detector capable of detecting halogen containing chemical agents and compounds that also do not contain a phosphorous or sulfur element.&nbsp; Detector is an alternate to existing Flame Photometric Detector (FPD) and Flame Ionization Detector (FID)</li>\n\t<li>Chromatographic column: MXT-1701 phase&nbsp;</li>\n\t<li>Air sampling Quick Change Trap Module with flow rate through the trap of at least 500mL/min</li>\n\t<li>External mass flow controller, ability to capture the flow meter readings</li>\n\t<li>Oven programmable from ambient to 400℃</li>\n\t<li>Cycle time from injection to injection of 15 minutes or less</li>\n\t<li>Visible and audible alarms for system faults and sample concentration detections</li>\n\t<li>Integrated GC engine, NUMAVIEW with touchscreen display, integrated processor, and storage.</li>\n\t<li>Data logging.&nbsp; Ability to capture instrument set points and measured values such as: sample flow, temperatures, pressures, calibration, concentration, injection type &ndash; calibration, service, sample, etc.&nbsp; Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data.</li>\n\t<li>Automatic calibration feature.&nbsp; Calibration of the instrument using an averaged single point or multi-point calibration curve.&nbsp; Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface.</li>\n\t<li>Heated exhaust to prevent expulsion of water.&nbsp; Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector.</li>\n\t<li>Sample bypass capability.&nbsp; Ability for continuous sample flow at inlet in a bypass state.&nbsp; A minimum flow of 500mL/min required for bypass capability.</li>\n\t<li>GC approximate dimensions - 17&rdquo; x 11&rdquo; x 8.5&rdquo; (width x height x depth)</li>\n\t<li>Instrument weight approximately 25 pounds</li>\n</ul>\n\n<p><strong>Shipping:</strong> Delivery shall be completed by 30 September 2026 or upon customer notification.</p>","text":"A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.\n\nProcure one GC instrument with the following specifications:\n\n• Detector capable of detecting halogen containing chemical agents and compounds that also do not contain a phosphorous or sulfur element. Detector is an alternate to existing Flame Photometric Detector (FPD) and Flame Ionization Detector (FID)\n\n• Chromatographic column: MXT-1701 phase\n\n• Air sampling Quick Change Trap Module with flow rate through the trap of at least 500mL/min\n\n• External mass flow controller, ability to capture the flow meter readings\n\n• Oven programmable from ambient to 400℃\n\n• Cycle time from injection to injection of 15 minutes or less\n\n• Visible and audible alarms for system faults and sample concentration detections\n\n• Integrated GC engine, NUMAVIEW with touchscreen display, integrated processor, and storage.\n\n• Data logging. Ability to capture instrument set points and measured values such as: sample flow, temperatures, pressures, calibration, concentration, injection type – calibration, service, sample, etc. Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data.\n\n• Automatic calibration feature. Calibration of the instrument using an averaged single point or multi-point calibration curve. Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface.\n\n• Heated exhaust to prevent expulsion of water. Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector.\n\n• Sample bypass capability. Ability for continuous sample flow at inlet in a bypass state. A minimum flow of 500mL/min required for bypass capability.\n\n• GC approximate dimensions - 17” x 11” x 8.5” (width x height x depth)\n\n• Instrument weight approximately 25 pounds\n\nShipping: Delivery shall be completed by 30 September 2026 or upon customer notification.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S6-26-Q-A011","place_of_performance":{"zip":"84022","city":{"code":"20450","name":"Dugway"},"state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6630"},{"award":{"date":"2026-04-07","amount":"259488.00","number":"W911S626PA004","awardee":{"raw":"TELEDYNE INSTRUMENTS INC City of Industry CA 91748 USA","uei":"J1SQC3517JK5","cage":"21070","name":"TELEDYNE INSTRUMENTS INC","location":{"zip":"91748","city":{"code":"13630","name":"City of Industry"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-04-20","posted_at":"2026-04-20T19:59:28.510Z","award_date":"2026-04-07","created_at":"2026-04-08T05:29:27.610Z","modified_at":"2026-04-23T03:55:45.976Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/b02cd1e2d7094e2ca724734711346f94/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Safety Air Monitoring and Analytical Referee Systems (SAMARS) Phase III Gas Chromatograph (GC)","agency":{"office":{"code":"W911S6","name":"W6QM MICC-DUGWAY PROV GRD"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"84022-5000","city":"DUGWAY","state":"UT","country":"USA"},"organization_id":"500036820","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-22","archive_type":"auto15"},"history":[{"index":3,"title":"Safety Air Monitoring and Analytical Referee Systems (SAMARS) Phase III Gas Chromatograph (GC)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T19:59:28.510Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"b02cd1e2d7094e2ca724734711346f94","solicitation_number":"W911S626PA004"}],"contacts":[{"name":"Nneka Okeke-Stubbs","role":"primary","email":"nneka.okeke-stubbs.civ@army.mil","phone":"4358312748"},{"name":"Amy Eilerts","role":"secondary","email":"amy.m.eilerts.civ@army.mil","phone":"4358312103"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"b02cd1e2d7094e2ca724734711346f94","lineage_id":"b02cd1e2d7094e2ca724734711346f94","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T09:36:23.462615402Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3b7667a4e139f1b1ae623d76fe2c7177e6fe39aeeb521617aa24b214706ec27a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T09:36:23.462615402Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Procurement of Safety Air Monitoring Replacement Gas Chromatograph (GC) equipment under Phase III to sustain compliant air‑monitoring and analytical detection capabilities.</p>","text":"Procurement of Safety Air Monitoring Replacement Gas Chromatograph (GC) equipment under Phase III to sustain compliant air‑monitoring and analytical detection capabilities.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"W911S626PA004","place_of_performance":{"zip":"84022","city":{"code":"20450","name":"Dugway"},"state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6630"}],"due_at":"2026-03-31T16:00:00Z","due_date":"2026-03-31","closes_at":"2026-03-31T16:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S6","office_name":"W6QM MICC-DUGWAY PROV GRD","state":"UT","county":"49045","county_name":"Tooele County","city":"4920450","city_name":"Dugway","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"J1SQC3517JK5","amount":"259488.00","linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-06T10:17:53.611858Z","principal_notice_id":"b02cd1e2d7094e2ca724734711346f94","description":{"text":"Procurement of Safety Air Monitoring Replacement Gas Chromatograph (GC) equipment under Phase III to sustain compliant air‑monitoring and analytical detection capabilities.","html":"<p>Procurement of Safety Air Monitoring Replacement Gas Chromatograph (GC) equipment under Phase III to sustain compliant air‑monitoring and analytical detection capabilities.</p>","origin":"detail"},"contacts":[{"name":"Nneka Okeke-Stubbs","role":"primary","email":"nneka.okeke-stubbs.civ@army.mil","phone":"4358312748"},{"name":"Amy Eilerts","role":"secondary","email":"amy.m.eilerts.civ@army.mil","phone":"4358312103"}],"place_of_performance":{"zip":"84022","city":{"code":"20450","name":"Dugway"},"state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"84022-5000","city":"DUGWAY","state":"UT","country":"USA"},"naics_codes":["334516"],"award":{"date":"2026-04-07","amount":"259488.00","number":"W911S626PA004","awardee":{"raw":"TELEDYNE INSTRUMENTS INC City of Industry CA 91748 USA","uei":"J1SQC3517JK5","cage":"21070","name":"TELEDYNE INSTRUMENTS INC","location":{"zip":"91748","city":{"code":"13630","name":"City of Industry"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"19a0acc294bf4ac19360641af8a863be","name":"JA Redacted SAMARS 26PA004 DPG 03-24-26.pdf","kind":"file","mime_type":".pdf","size_bytes":439964,"posted_at":"2026-04-20T19:59:28.510Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/19a0acc294bf4ac19360641af8a863be/download","mirrored":false},{"resource_id":"5aa24d95578e46b88d2f48e42d5d6d07","name":"SAMARS Phase 3 JA Redacted.pdf","kind":"file","mime_type":".pdf","size_bytes":439964,"posted_at":"2026-03-24T20:53:20.862Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5aa24d95578e46b88d2f48e42d5d6d07/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_W911S626PA004_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W911S626PA004_9700_-NONE-_-NONE-/","piid":"W911S626PA004","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"J1SQC3517JK5","recipient_name":"TELEDYNE INSTRUMENTS INC","recipient_uei":"J1SQC3517JK5","recipient_cage":"21070","recipient_city":"CITY OF INDUSTRY","recipient_state":"CA","sub_name":"Department of the Army","office_name":"W6QM MICC-DUGWAY PROV GRD","office_key":"o-W911S6","first_action_date":"2026-04-07","last_action_date":"2026-04-07","actions":1,"obligated":"259488.00","current_total_value":"259488.00","potential_total_value":"259488.00","naics":"334516","psc":"6630","extent_competed":"NOT COMPETED","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"THE PURCHASE AND DELIVERY OF THE SAFETY AIR MONITORING AND ANALYTICAL REFEREE SYSTEMS (SAMARS) PHASE III GAS CHROMATOGRAPH (GC).","method":"piid","confidence":"high","evidence":["award number W911S626PA004 equals the contract number","same awarding office W911S6"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"W911S626AGILENT","latest_notice_id":"a206fcc4e6854dbdbddc3d3df9c21ea3","title":"Agilent Equipment Preventative Maintenance, Repair, and Upgrade Services","solicitation_number":"W911S626AGILENT","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S6","office_name":"W6QM MICC-DUGWAY PROV GRD","naics":"811210","psc":"J066","set_aside":null,"state":"UT","county":"49045","county_name":"Tooele County","city":"4920450","city_name":"Dugway","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"W911S627RA001","latest_notice_id":"8a3c247f801e40bda623b7c12e69f7c9","title":"Custodial Services","solicitation_number":"W911S6-27-R-A001","notice_type":"r","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S6","office_name":"W6QM MICC-DUGWAY PROV GRD","naics":"561720","psc":"S201","set_aside":"8A","state":"UT","county":"49045","county_name":"Tooele County","city":"4920450","city_name":"Dugway","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"}],"similar_open":[{"key":"W911S227U0189","latest_notice_id":"16fcf7e6617f41c693bf28ad16bb9f12","title":"Sensigent MSEM 160","solicitation_number":"W911S227U0189","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-23","notices":2,"due_at":"2026-11-30T18:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6640","set_aside":"SBA","state":"UT","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"WDTC RCVGDUGWAY PROVING GROUND4223 2ND ST.DUGWAY, UT 84022","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"80NSSC27948984Q","latest_notice_id":"8633902fb0824dcdb772b67cf406e07e","title":"Cryostar, 3 High Pressure Pumps for Liquid Oxygen System, RECIPROCATING PUMP A-MRP 40/55 OL1 T and 1 Triple Auto Control Panel for Liquid Oxygen Pumps","solicitation_number":"80NSSC27948984Q","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T13:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"334516","psc":"6695","set_aside":"SBA","state":"NM","county":"35013","county_name":"Doña Ana County","city":"3539380","city_name":"Las Cruces","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"N3904027Q5950","latest_notice_id":"7854cc2258d4429d88f50a77f602eac5","title":"Calibrate PAMAS SBSS","solicitation_number":"N3904027Q5950","notice_type":"o","first_type":"o","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N39040","office_name":"PORTSMOUTH NAVAL SHIPYARD GF","naics":"334516","psc":"J066","set_aside":null,"state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":62,"indexable":false}