Award notice, first published as combined synopsis and solicitation
Safety Air Monitoring and Analytical Referee System (SAMARS) Gas Chromatograph (GC)
W911S6-24-Q-0034
Department of the Army, W6QM Micc-Dugway Prov GRD. Analytical Laboratory Instrument Manufacturing.
Awarded
$228,674.00 on the award notice, March 24, 2025, contract W911S625P0002
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one was awarded in 2025
55 like it are open now in analytical laboratory instrument manufacturing
- Sensigent MSEM 160
Department of the Army, W6QM Micc-Ft Drum
Combined synopsis and solicitationSmall businessNAICS 334516Ship to UTW911S227U0189Due in 4 daysNov 30 - iWorx
Department of the Army, W6QM Micc-Ft Drum
Combined synopsis and solicitationSmall businessNAICS 334516Ship to NYW911S227U0166Due todayNov 26 - Incubator Shaker
Department of the Army, W6QM Micc-Ft Drum
Combined synopsis and solicitationSmall businessNAICS 334516Ship to NYW911S227U0167Due todayNov 26
All 55 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Award notice. Who won, when, and for how much. Glossary
- Time to respond
- Bidders had 13 days from the day the solicitation was posted, February 25, 2025, to the deadline.
- How it ended
- Awarded to Teledyne Instruments Inc. on March 24, 2025, 14 days after offers were due. The contracting office reported 3 offers (competed under simplified acquisition procedures).
Description
As published on SAM.gov.
Procure two GC instruments with the following specifications:
-
- Flame Photometric Detector (FPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter
- Chromatographic columns: one instrument DB-1701 phase and one instrument DB-210 phase column;
- Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500 mL/min
- External mass flow controller, ability to capture the flow meter readings
- Oven programmable from ambient to 400℃
- Cycle time from injection to injection of 15 minutes or less
- Visible and audible alarms for system faults and sample concentration detections
- Quick change trap assembly, flow rate of 500 mL/min with ability to change the preconcentrator tube in approximately 1 minute
- Onboard integration engine with graphical use interface. Ability to operate the instrument, calibrate, troubleshoot, analyze samples, etc. from the user interface. Visual readouts displayed of set points and measurements such as: sample flow, temperatures, pressures, concentrations, injection types, valve status, voltage, etc.
- Data logging. Ability to capture instrument set points and measured values such as: flow, temperatures, pressures, calibration, concentration, injection type – calibration, service, sample, etc. Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data.
- Automatic calibration feature. Calibration of the instrument using an averaged single point or multi-point calibration curve. Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface.
- Heated exhaust to prevent expulsion of water. Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector.
- Sample bypass capability. Ability for continuous sample flow at inlet in a bypass state. A minimum flow of 500 mL/min required for bypass capability.
- GC approximate dimensions - 17” x 11” x 8.5” (width x height x depth)
- Instrument weight approximately 25 pounds
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- JA SAMARS_Redacted.pdf2.1 MB, February 26, 2025
- SAMARS Combined Synopsis Solicitation SoleSource.pdf389 KB, February 26, 2025
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Teledyne Instruments Inc.
- UEI
- J1SQC3517JK5
- CAGE
- 21070
- Vendor location
- City of Industry, CA
- Contract
- W911S625P0002, purchase order
- Obligated
- $228,674.00
- Actions
- 3 between March 24, 2025 and August 19, 2025
- Competition
- Competed Under SAP, 3 offers received
- Set-aside reported
- No Set Aside Used.
- Described as
- Safety Air Monitoring and Analytical Referee System
- Match
- award number W911S625P0002 equals the contract number; same awarding office W911S6 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 26, 2025
Combined synopsis and solicitation
Due March 10, 2025 at 1:00 PM EDT. SAM.gov, notice 0b011432bab844789eb2e88e24a518b8
1 revision on SAM
- February 26, 2025: publish, combined synopsis and solicitation
April 8, 2025
Award notice
Awarded to Teledyne Instruments Inc. for $228,674. SAM.gov, notice 7902881e291d4c01a62da4541fee13f3
1 revision on SAM
- April 8, 2025: publish, award notice
Points of contact
- Nneka Okeke-Stubbsnneka.okeke-stubbs.civ@army.mil4358312748
- Paul E. Fraileypaul.e.frailey.civ@army.mil4358312587