DPG MINICAMs Maintenance and Repair
W911S6-24-MINICAMs
Department of the Army, W6QM Micc-Dugway Prov GRD. Electronic and Precision Equipment Repair and Maintenance.
Response deadline
March 14, 2024 at 6:00 PM EDT
Closed 989 days ago. Posted February 28, 2024. Scheduled to archive March 14, 2024.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2024
60 like it are open now in electronic and precision equipment repair and maintenance
- Agilent Equipment Preventative Maintenance, Repair, and Upgrade Services
Department of the Army, W6QM Micc-Dugway Prov GRD
Sources soughtNAICS 811210Dugway, UTW911S626AGILENTDue in 3 daysDec 1 - SOLICITATION: 415 SCMS STRATEGIC MAC IDIQ CONTRACT
Department of the Air Force, FA8250 AFSC Pzaaa
SolicitationNAICS 811210UtahFA825026R0001Due in 3 daysDec 1 - Request for Information - Gastrointestinal Endoscopy Equipment Repair and Maintenance Services
Defense Health Agency (Dha), Defense Health Agency HCD West
Sources soughtNAICS 811210CaliforniaHT941027RFI0001Due todayNov 28
All 60 open in electronic and precision equipment repair and maintenance
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 811210 (electronic and precision equipment repair and maintenance), means no more than $34 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of February 28, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Dugway Proving Ground (DPG) West Destert Test Center requires maintenance and repair for MINICAM Safety Air Monitoring Equipment at a level that us unable to be performed locally. MINICAMS is a fully automated, continuous, near-real-time air monitoring system.
It was designed primarily for use in the U.S. Army's Chemical Stockpile Disposal Program as an automated chemical-vapor alarm system for monitoring of workplace air and other potentially contaminated in-plant zones, e.g., stack exhausts, ducts, filter banks, etc. It also works well for support of materials-penetration and permeation studies and many other laboratory or on-site test efforts involving a need to detect and quantify chemical vapors automatically and continuously.
It provides audible, visible, and electrical alarm responses to toxic military chemical agent vapors, e.g., GB, VX, HD, etc., and to many other substances at any of a variety of regulatory threshold concentrations, e.g., TWA, MDL, PEL, etc. It also provides accurate vapor concentration readings at concentrations in the general vicinity of the preset alarm threshold.
It was specifically designed to detect and accurately quantify the chemical agents and other volatile and semi-volatile compounds at far lower concentrations than most other chemical vapor monitors. MINICAMS is a readily transportable system that is designed to be set up and operated at fixed indoor locations or (under mild conditions) at sheltered outdoor monitoring stations, although instances of successful use in vehicles and other mobile platforms have occurred.
It requires one or more compressed gases and a source of 117VAC electrical power for its operation. MINICAMS is based on collection of airborne chemical vapors on a solid sorbent or in a sample loop, thermal desorption or flushing of the collected vapors into a gas chromatographic (GC) column, separation of the sample constituents on the column, and detection by a sensitive GC detector.
The available GC detectors include both universal (i.e., nonselective) detector types that respond indiscriminately to virtually all substances, and selective detectors that respond primarily to certain restricted classes of chemicals. The instrument cycles repetitively through a Sample Period, during which an air sample is accumulated, and a subsequent Purge Period, during which the collected sample constituents are separated, detected, and quantified.
Total instrument cycle times can range from about 5 min to 20 min or more. When a selective detector is installed, MINICAMS delivers accurate quantification and detection limits in the parts-per-billion and/or parts-per-quadrillion range as a matter of routine, although the system can be reconfigured or "detuned" to cover almost any desired concentration range above these levels.