Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 7,911 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Sources sought

DPG MINICAMs Maintenance and Repair

W911S6-24-MINICAMs

Department of the Army, W6QM Micc-Dugway Prov GRD. Electronic and Precision Equipment Repair and Maintenance.

Response deadline

March 14, 2024 at 6:00 PM EDT

Closed 989 days ago. Posted February 28, 2024. Scheduled to archive March 14, 2024.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2024

60 like it are open now in electronic and precision equipment repair and maintenance

All 60 open in electronic and precision equipment repair and maintenance

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 811210 (electronic and precision equipment repair and maintenance), means no more than $34 million in average annual receipts, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of February 28, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

Dugway Proving Ground (DPG) West Destert Test Center requires maintenance and repair for MINICAM Safety Air Monitoring Equipment at a level that us unable to be performed locally. MINICAMS is a fully automated, continuous, near-real-time air monitoring system.

It was designed primarily for use in the U.S. Army's Chemical Stockpile Disposal Program as an automated chemical-vapor alarm system for monitoring of workplace air and other potentially contaminated in-plant zones, e.g., stack exhausts, ducts, filter banks, etc. It also works well for support of materials-penetration and permeation studies and many other laboratory or on-site test efforts involving a need to detect and quantify chemical vapors automatically and continuously.

It provides audible, visible, and electrical alarm responses to toxic military chemical agent vapors, e.g., GB, VX, HD, etc., and to many other substances at any of a variety of regulatory threshold concentrations, e.g., TWA, MDL, PEL, etc. It also provides accurate vapor concentration readings at concentrations in the general vicinity of the preset alarm threshold.

It was specifically designed to detect and accurately quantify the chemical agents and other volatile and semi-volatile compounds at far lower concentrations than most other chemical vapor monitors. MINICAMS is a readily transportable system that is designed to be set up and operated at fixed indoor locations or (under mild conditions) at sheltered outdoor monitoring stations, although instances of successful use in vehicles and other mobile platforms have occurred.

It requires one or more compressed gases and a source of 117VAC electrical power for its operation. MINICAMS is based on collection of airborne chemical vapors on a solid sorbent or in a sample loop, thermal desorption or flushing of the collected vapors into a gas chromatographic (GC) column, separation of the sample constituents on the column, and detection by a sensitive GC detector.

The available GC detectors include both universal (i.e., nonselective) detector types that respond indiscriminately to virtually all substances, and selective detectors that respond primarily to certain restricted classes of chemicals. The instrument cycles repetitively through a Sample Period, during which an air sample is accumulated, and a subsequent Purge Period, during which the collected sample constituents are separated, detected, and quantified.

Total instrument cycle times can range from about 5 min to 20 min or more. When a selective detector is installed, MINICAMS delivers accurate quantification and detection limits in the parts-per-billion and/or parts-per-quadrillion range as a matter of routine, although the system can be reconfigured or "detuned" to cover almost any desired concentration range above these levels.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. February 28, 2024

    Sources sought

    Due March 14, 2024 at 6:00 PM EDT. SAM.gov, notice 7e8e5bbbea434a97b557a8cbe5452721

Points of contact