{"canonical":"https://sealedbidder.com/opportunities/w911s226u4509","key":"W911S226U4509","url":"https://sealedbidder.com/opportunities/w911s226u4509","title":"DOUBLE WALL INSULATED DUCTING","solicitation_number":"W911S226U4509","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-24T15:00:00Z","first_posted":"2026-09-21","last_posted":"2026-09-23","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"332322","psc":"4520","set_aside":"SBA","place_state":"OK","place_scope":"nationwide","site":null,"place_state_source":"sam_street","place_evidence":"MCALESTER ARMY AMMUNITION PLANT; 1 C-TREE ROAD, BUILDING 6; MCALESTER, OK 74501","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"935547c9005b40848f8a202853b1e8c5","title":"DOUBLE WALL INSULATED DUCTING","solicitation_number":"W911S226U4509","notice_type":"k","base_type":"k","posted":"2026-09-21","posted_at":"2026-09-21T19:25:14.615Z","due_at":"2026-09-29T15:00:00Z","due_date":"2026-09-29","cancelled":null,"archived":null,"archive_date":"2027-09-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/935547c9005b40848f8a202853b1e8c5/view","enriched":true,"history":[{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}]},{"notice_id":"c9fa98242f5444edb154a65525a9112c","title":"DOUBLE WALL INSULATED DUCTING","solicitation_number":"W911S226U4509","notice_type":"k","base_type":"k","posted":"2026-09-22","posted_at":"2026-09-22T14:59:30.994Z","due_at":"2026-09-29T15:00:00Z","due_date":"2026-09-29","cancelled":false,"archived":false,"archive_date":"2027-09-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c9fa98242f5444edb154a65525a9112c/view","enriched":true,"history":[{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}]},{"notice_id":"dbb800de59734e918b4c8a28dccfa05b","title":"DOUBLE WALL INSULATED DUCTING","solicitation_number":"W911S226U4509","notice_type":"k","base_type":"k","posted":"2026-09-23","posted_at":"2026-09-23T11:13:17.507Z","due_at":"2026-09-24T15:00:00Z","due_date":"2026-09-24","cancelled":false,"archived":false,"archive_date":"2027-09-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dbb800de59734e918b4c8a28dccfa05b/view","enriched":true,"history":[{"index":3,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-23T11:13:17.507Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"dbb800de59734e918b4c8a28dccfa05b","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}]}],"latest_notice_id":"dbb800de59734e918b4c8a28dccfa05b","first_type":"k","notices":[{"dates":{"posted":"2026-09-21","posted_at":"2026-09-21T19:25:14.615Z","created_at":"2026-09-21T19:25:14.538Z","modified_at":"2026-09-22T14:59:30.994Z","response_deadline":{"raw":"2026-09-29T10:00:00-05:00","utc":"2026-09-29T15:00:00Z","date":"2026-09-29","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/935547c9005b40848f8a202853b1e8c5/view"},"naics":{"codes":["332322"],"primary":"332322"},"title":"DOUBLE WALL INSULATED DUCTING","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2027-09-21","archive_type":"auto_custom"},"history":[{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}],"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"935547c9005b40848f8a202853b1e8c5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"935547c9005b40848f8a202853b1e8c5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-23T00:26:54.284609957Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"8963c7122dd647cc0a906b356b8e164ce0cdc975fa4a74662bb6c8ae2c351651","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-22T04:18:56.687806512Z"},"description":{"html":"Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet  2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4  3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2  4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1  5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum.  Quantity: 41  6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum.  Quantity: 21  7. Flange for 28-inch Port  Part Code: 286G  Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1  8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","text":"Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet 2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4 3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2 4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1 5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum. Quantity: 41 6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum. Quantity: 21 7. Flange for 28-inch Port Part Code: 286G Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1 8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U4509","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"product_service_code":"4520"},{"dates":{"posted":"2026-09-22","posted_at":"2026-09-22T14:59:30.994Z","created_at":"2026-09-22T14:59:30.177Z","modified_at":"2026-09-22T14:59:30.994Z","response_deadline":{"raw":"2026-09-29T10:00:00-05:00","utc":"2026-09-29T15:00:00Z","date":"2026-09-29","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c9fa98242f5444edb154a65525a9112c/view"},"naics":{"codes":["332322"],"primary":"332322"},"title":"DOUBLE WALL INSULATED DUCTING","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-09-22","archive_type":"auto_custom"},"history":[{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}],"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"c9fa98242f5444edb154a65525a9112c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"935547c9005b40848f8a202853b1e8c5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-23T04:32:30.624763243Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"d1fc91c7576ad3e8331f05413601d328c3454f376b16449944007c46e37ad793","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-23T03:49:19.112235372Z"},"description":{"html":"amended to reduce days due to cut off.  Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet  2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4  3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2  4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1  5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum.  Quantity: 41  6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum.  Quantity: 21  7. Flange for 28-inch Port  Part Code: 286G  Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1  8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","text":"amended to reduce days due to cut off. Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet 2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4 3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2 4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1 5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum. Quantity: 41 6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum. Quantity: 21 7. Flange for 28-inch Port Part Code: 286G Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1 8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U4509","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"product_service_code":"4520"},{"dates":{"posted":"2026-09-23","posted_at":"2026-09-23T11:13:17.507Z","created_at":"2026-09-23T11:13:16.716Z","modified_at":"2026-09-23T11:13:17.507Z","response_deadline":{"raw":"2026-09-24T10:00:00-05:00","utc":"2026-09-24T15:00:00Z","date":"2026-09-24","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dbb800de59734e918b4c8a28dccfa05b/view"},"naics":{"codes":["332322"],"primary":"332322"},"title":"DOUBLE WALL INSULATED DUCTING","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-09-23","archive_type":"auto_custom"},"history":[{"index":3,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-23T11:13:17.507Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"dbb800de59734e918b4c8a28dccfa05b","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":2,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-22T14:59:30.994Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c9fa98242f5444edb154a65525a9112c","solicitation_number":"W911S226U4509","parent_opportunity_id":"935547c9005b40848f8a202853b1e8c5"},{"index":1,"title":"DOUBLE WALL INSULATED DUCTING","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-21T19:25:14.615Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"935547c9005b40848f8a202853b1e8c5","solicitation_number":"W911S226U4509"}],"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"dbb800de59734e918b4c8a28dccfa05b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"935547c9005b40848f8a202853b1e8c5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T05:03:52.800056797Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"29002450d437e0288e6680852dd067fbbc88ef157cbfbef4f9298dd01d505f57","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-24T04:21:46.782462570Z"},"description":{"html":"amended to reduce days due to cut off.  Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet  2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4  3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2  4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1  5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum.  Quantity: 41  6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum.  Quantity: 21  7. Flange for 28-inch Port  Part Code: 286G  Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1  8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","text":"amended to reduce days due to cut off. Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet 2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4 3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2 4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1 5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum. Quantity: 41 6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum. Quantity: 21 7. Flange for 28-inch Port Part Code: 286G Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1 8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U4509","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"product_service_code":"4520"}],"due_at":"2026-09-24T15:00:00Z","due_date":"2026-09-24","closes_at":"2026-09-24T15:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":"OK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"MCALESTER ARMY AMMUNITION PLANT; 1 C-TREE ROAD, BUILDING 6; MCALESTER, OK 74501","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-03T03:55:19.037358Z","principal_notice_id":"dbb800de59734e918b4c8a28dccfa05b","description":{"text":"amended to reduce days due to cut off. Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet 2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4 3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2 4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1 5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum. Quantity: 41 6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum. Quantity: 21 7. Flange for 28-inch Port Part Code: 286G Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1 8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","html":"amended to reduce days due to cut off.  Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet  2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4  3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2  4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1  5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum.  Quantity: 41  6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum.  Quantity: 21  7. Flange for 28-inch Port  Part Code: 286G  Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1  8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2","origin":"detail"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["332322"],"award":null,"attachments":[{"resource_id":"44b6ac06a5d34fb8a6cb0fe68cd386c2","name":"dodprocurementtoolbox.com","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-09-21T19:25:14.615Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false}],"awards":[],"related":[{"key":"W911S227U0167","latest_notice_id":"329dd9aaa84845dbba2130418ce2ad17","title":"Incubator Shaker","solicitation_number":"W911S227U0167","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0166","latest_notice_id":"55af918bb27d41c29cf8b4f1c1cd01e9","title":"iWorx","solicitation_number":"W911S227U0166","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0067","latest_notice_id":"27cb39c606874abaa0a99e4b30bf374c","title":"Dictionaries","solicitation_number":"W911S227U0067","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"323117","psc":"7610","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W911S227U0204","latest_notice_id":"873cf78c2d1b430ba2557e89f574a426","title":"Aerial Firefighting System","solicitation_number":"W911S227U0204","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T23:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"333120","psc":"4210","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"FORT HOOD, TEXAS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"FA446027Q0004","latest_notice_id":"3a51490b15f34443a76821f3b67e10df","title":"Roof Snow Block","solicitation_number":"FA446027Q0004","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4460","office_name":"FA4460 19 CONS PKA","naics":"332322","psc":"5650","set_aside":"SBA","state":"AR","county":"05119","county_name":"Pulaski County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"SPE4A727T4720","latest_notice_id":"9d2af17bdffd4518840cf3fc950ab738","title":"58--CAMERA,TELEVISION","solicitation_number":"SPE4A727T4720","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A7","office_name":"DLA AVIATION","naics":"332322","psc":"58","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"ISION: LINE 0001 QTY 7 UI EA DELIVER TO: DLA DISTRIBUTION SAN DIEGO BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"SPE7M227T1013","latest_notice_id":"b75a222a288a4411bff977f6c71262be","title":"58--CONTROL,TELEVISION CAM","solicitation_number":"SPE7M227T1013","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-12-03","closes_at":"2026-12-04T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M2","office_name":"DLA WEAPONS SUPPORT","naics":"332322","psc":"58","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"N CAM: LINE 0001 QTY 5 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":4,"indexable":false}