{"canonical":"https://sealedbidder.com/opportunities/w911s226u2446","key":"W911S226U2446","url":"https://sealedbidder.com/opportunities/w911s226u2446","title":"LCMS","solicitation_number":"W911S226U2446","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-30","first_posted":"2026-01-14","last_posted":"2026-01-14","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6630)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"103641ae64874cfe8be78200849a8a39","title":"LCMS","solicitation_number":"W911S226U2446","notice_type":"k","base_type":"k","posted":"2026-01-14","posted_at":"2026-01-14T18:00:03.767Z","due_at":null,"due_date":"2026-01-30","cancelled":false,"archived":false,"archive_date":"2027-01-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/103641ae64874cfe8be78200849a8a39/view","enriched":true,"history":[{"index":1,"title":"LCMS","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-01-14T18:00:03.767Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"103641ae64874cfe8be78200849a8a39","solicitation_number":"W911S226U2446"}]}],"latest_notice_id":"103641ae64874cfe8be78200849a8a39","first_type":"k","notices":[{"dates":{"posted":"2026-01-14","posted_at":"2026-01-14T18:00:03.767Z","created_at":"2026-01-14T18:00:03.710Z","modified_at":"2026-01-14T18:00:03.767Z","response_deadline":{"raw":"2026-01-30T16:00:00","date":"2026-01-30","time":"16:00:00","timezone":"America/New_York"}},"links":{"sam":"https://sam.gov/workspace/contract/opp/103641ae64874cfe8be78200849a8a39/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"LCMS","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_id":"500036690","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-14","archive_type":"auto_custom"},"history":[{"index":1,"title":"LCMS","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-01-14T18:00:03.767Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"103641ae64874cfe8be78200849a8a39","solicitation_number":"W911S226U2446"}],"contacts":[{"name":"Carl Lundell","role":"primary","email":"carl.lundell@westpoint.edu","phone":"571.748.9816"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"103641ae64874cfe8be78200849a8a39","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"103641ae64874cfe8be78200849a8a39","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-22T00:16:59.102491810Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"04f6e569e78f40a246f3ac57843eaa3f78b297d3b23c95ee14c397485dceba66","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-22T00:16:59.102491810Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration.  The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution.  Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting.  Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range.  Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.","text":"Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U2446","place_of_performance":{"zip":"10996","street":"Building 753 Cullum Road, West Point NY, 10996"},"product_service_code":"6630"}],"due_at":null,"due_date":"2026-01-30","closes_at":"2026-01-31T00:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6630)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-02T10:12:41.097506Z","principal_notice_id":"103641ae64874cfe8be78200849a8a39","description":{"text":"Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.","html":"Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration.  The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution.  Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting.  Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range.  Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.","origin":"detail"},"contacts":[{"name":"Carl Lundell","role":"primary","email":"carl.lundell@westpoint.edu","phone":"571.748.9816"}],"place_of_performance":{"zip":"10996","street":"Building 753 Cullum Road, West Point NY, 10996"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"344fbc53b0f746c09c78db07685e1cf7","name":"dodprocurementtoolbox.com","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-01-14T18:00:03.767Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false}],"awards":[],"related":[{"key":"W911S227U0195","latest_notice_id":"97b456f6ebf8446a8eaab01f982a6497","title":"Fiberboard filler sheet, top/bottom and side","solicitation_number":"W911S227U0195","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-11-26T11:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"322211","psc":"8135","set_aside":"SBA","state":"AR","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"PINE BLUFF ARSENAL, 504TH ST, BLDG 53-990, CENTRAL RECEIVING PT., PINE BLUFF, AR 71602","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W911S227U0167","latest_notice_id":"329dd9aaa84845dbba2130418ce2ad17","title":"Incubator Shaker","solicitation_number":"W911S227U0167","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0166","latest_notice_id":"55af918bb27d41c29cf8b4f1c1cd01e9","title":"iWorx","solicitation_number":"W911S227U0166","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0067","latest_notice_id":"27cb39c606874abaa0a99e4b30bf374c","title":"Dictionaries","solicitation_number":"W911S227U0067","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"323117","psc":"7610","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"SPE4A627T115J","latest_notice_id":"549884a815a04a6888c9a3d2fd835672","title":"66--PROBE,EDDY CURRENT","solicitation_number":"SPE4A627T115J","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A6","office_name":"DLA AVIATION","naics":"334516","psc":"66","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"URRENT: LINE 0001 QTY 2 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"75N98027Q00098","latest_notice_id":"c6cba74e3d69486d947ad2c0090fe443","title":"NCSS - Coldhead Exchange Parts and Calibration for","solicitation_number":"75N98027Q00098","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T12:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140D0426Q0057","latest_notice_id":"bf91e843e5d1451f813de6f01f52de01","title":"66--NOI to Sole Source ESLfemto Laser","solicitation_number":"140D0426Q0057","notice_type":"p","first_type":"r","first_posted":"2026-02-13","last_posted":"2026-11-25","notices":4,"due_at":"2026-12-01T14:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140D04","office_name":"IBC ACQ SVCS DIRECTORATE (00004)","naics":"334516","psc":"6630","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6630)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open_total":55,"indexable":false}