{"canonical":"https://sealedbidder.com/opportunities/w911s225u2011","key":"W911S225U2011","url":"https://sealedbidder.com/opportunities/w911s225u2011","title":"Lagoon Aerator Assembly","solicitation_number":"W911S225U2011","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-16T08:00:00Z","first_posted":"2025-09-09","last_posted":"2025-09-09","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"333998","psc":"4630","set_aside":"SBA","place_state":"CA","place_scope":"nationwide","site":null,"place_state_source":"sam_street","place_evidence":"USAG FT HUNTER LIGGETT B319 LAGOON DR JOLON, CA 93928","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"e187054f19b84615a9e31ec8c6959174","title":"Lagoon Aerator Assembly","solicitation_number":"W911S225U2011","notice_type":"k","base_type":"k","posted":"2025-09-09","posted_at":"2025-09-09T19:23:12.820Z","due_at":"2025-09-16T08:00:00Z","due_date":"2025-09-16","cancelled":false,"archived":true,"archive_date":"2026-09-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e187054f19b84615a9e31ec8c6959174/view","enriched":true,"history":[{"index":3,"title":"Lagoon Aerator Assembly","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-09T19:23:12.820Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e187054f19b84615a9e31ec8c6959174","solicitation_number":"W911S225U2011"}]}],"latest_notice_id":"e187054f19b84615a9e31ec8c6959174","first_type":"k","notices":[{"dates":{"posted":"2025-09-09","posted_at":"2025-09-09T19:23:12.820Z","created_at":"2025-09-09T19:23:12.770Z","modified_at":"2026-09-09T05:07:31.979Z","response_deadline":{"raw":"2025-09-16T01:00:00-07:00","utc":"2025-09-16T08:00:00Z","date":"2025-09-16","time":"01:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e187054f19b84615a9e31ec8c6959174/view"},"naics":{"codes":["333998"],"primary":"333998"},"title":"Lagoon Aerator Assembly","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_id":"500036690","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-09","archive_type":"auto_custom"},"history":[{"index":3,"title":"Lagoon Aerator Assembly","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-09-09T19:23:12.820Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e187054f19b84615a9e31ec8c6959174","solicitation_number":"W911S225U2011"}],"contacts":[{"name":"Juanito Bautista","role":"primary","email":"juanito.d.bautista.civ@army.mil","phone":"8313863428"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"e187054f19b84615a9e31ec8c6959174","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"e187054f19b84615a9e31ec8c6959174","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T03:11:51.871502118Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"f5fc0a85863adcc7ac44a182e02e0fd4198fa818b6817663fd3e89d5af93e44f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-10-31T03:11:51.871502118Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Waste Water Aerator System MOTOR:HORSEPWER: 14.5-15.5RPM: 1150-1250Full Load AMPS:42/21Voltage 230/460Voltage Phase: 3Cycle: 60Service Factor: 1.15-1.20Insulation Class: ?F? NON-Hygroscopic Bearings:Double Row Angular Contact Bearing Life: 950K-1200K hours Enclosure: Totally Enclose Fan-Cooled Motor (TEFC)MOTORSHAFT: Shaft Material: 17-4 Precipitation-Harding (PH), Stainless steel ( S.S), 1150 Condition Shaft Length: 28inches fromend shield face of motor Shaft Diameter: 1.625 inch O.D Minimum Yield Strength: 135K PSI Maximum Yield Strength: 250KPSIPROPELLER: Material: 316 Stainless Steel Balancing: Dynamically to Less than � MIL Maximum DEFLECTOR: Material:304 Stainless Steel, HDG Steel and FRP Exterior Finish: CHEM. Resistant GEL-Coat UV Plate Internal Fill: #3 Quartzite andResin Mixture Minimum FRP Thickness: .375 inch Exterior Color: White Weight: 485-490 LBs POWER MODULE SUPPORTRING: Material: 304 Stainless Steel Dimensions of Flat Rings: .5inch by 3inch by 42 inches O.D. Dimensions of support Rod:1.5 inch by 6 inches Method of construction: Welded AERATOR FLOAT: Method of Construction: Hand Lay Up Material: CDM2415 PROMAT and Chemical Resistant Resin External Finish: Chemical Resistant Gel-Coat UV Stabilized External Color:White Internal Reinforcing (Power Module Support) 3/8 in by 3 inch by 42 inches O.D. Steel Ring Internal Reinforcing (MooringEyes): 3/8inch by 3inches by 9 inches Flat Bar Throat Section Reinforcing: 2inch by 2 inch Encapsulated Ribs Internal Fill:2#DEN. Polyurethane Closed Cell Foam Minimum Thickness: .25inch NON-Stress Areas Mooring Eye Dimension 5/8 inchby 3 inch long Float Diameter: 88 inches Float Thickness: 14 inches Sink Safety Factor: 2.5Volute Thickness: FRP .75 inchThick PERFORMANCE: Pumping Rate: 12,172 GPM02 Transfer Rate: 3.0 LBS/HP/HR/Min Minimum DIA. Of Complete Mix at6 feet Depth: 80 Feet Minimum DIA. Of O2 Dispersion at 6feet Depth: 210 Feet WT. Of Completed Unit: estimated 1700 LBSShipping WT Height of Complete Unit: minimum 54 inches/ max 60 inches. Vendor Provide Aerator Dimensions Chart andmanual  Mustbe able to deliver on Weekdays 7am to 3 pm","text":"Waste Water Aerator System MOTOR:HORSEPWER: 14.5-15.5RPM: 1150-1250Full Load AMPS:42/21Voltage 230/460Voltage Phase: 3Cycle: 60Service Factor: 1.15-1.20Insulation Class: ?F? NON-Hygroscopic Bearings:Double Row Angular Contact Bearing Life: 950K-1200K hours Enclosure: Totally Enclose Fan-Cooled Motor (TEFC)MOTORSHAFT: Shaft Material: 17-4 Precipitation-Harding (PH), Stainless steel ( S.S), 1150 Condition Shaft Length: 28inches fromend shield face of motor Shaft Diameter: 1.625 inch O.D Minimum Yield Strength: 135K PSI Maximum Yield Strength: 250KPSIPROPELLER: Material: 316 Stainless Steel Balancing: Dynamically to Less than � MIL Maximum DEFLECTOR: Material:304 Stainless Steel, HDG Steel and FRP Exterior Finish: CHEM. Resistant GEL-Coat UV Plate Internal Fill: #3 Quartzite andResin Mixture Minimum FRP Thickness: .375 inch Exterior Color: White Weight: 485-490 LBs POWER MODULE SUPPORTRING: Material: 304 Stainless Steel Dimensions of Flat Rings: .5inch by 3inch by 42 inches O.D. Dimensions of support Rod:1.5 inch by 6 inches Method of construction: Welded AERATOR FLOAT: Method of Construction: Hand Lay Up Material: CDM2415 PROMAT and Chemical Resistant Resin External Finish: Chemical Resistant Gel-Coat UV Stabilized External Color:White Internal Reinforcing (Power Module Support) 3/8 in by 3 inch by 42 inches O.D. Steel Ring Internal Reinforcing (MooringEyes): 3/8inch by 3inches by 9 inches Flat Bar Throat Section Reinforcing: 2inch by 2 inch Encapsulated Ribs Internal Fill:2#DEN. Polyurethane Closed Cell Foam Minimum Thickness: .25inch NON-Stress Areas Mooring Eye Dimension 5/8 inchby 3 inch long Float Diameter: 88 inches Float Thickness: 14 inches Sink Safety Factor: 2.5Volute Thickness: FRP .75 inchThick PERFORMANCE: Pumping Rate: 12,172 GPM02 Transfer Rate: 3.0 LBS/HP/HR/Min Minimum DIA. Of Complete Mix at6 feet Depth: 80 Feet Minimum DIA. Of O2 Dispersion at 6feet Depth: 210 Feet WT. Of Completed Unit: estimated 1700 LBSShipping WT Height of Complete Unit: minimum 54 inches/ max 60 inches. Vendor Provide Aerator Dimensions Chart andmanual Mustbe able to deliver on Weekdays 7am to 3 pm","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U2011","place_of_performance":{"zip":"93928","street":"USAG Ft Hunter Liggett B319 Lagoon Dr Jolon, CA 93928"},"product_service_code":"4630"}],"due_at":"2025-09-16T08:00:00Z","due_date":"2025-09-16","closes_at":"2025-09-16T08:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"sam_street","state_evidence":"USAG FT HUNTER LIGGETT B319 LAGOON DR JOLON, CA 93928","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-31T03:13:48.729550Z","principal_notice_id":"e187054f19b84615a9e31ec8c6959174","description":{"text":"Waste Water Aerator System MOTOR:HORSEPWER: 14.5-15.5RPM: 1150-1250Full Load AMPS:42/21Voltage 230/460Voltage Phase: 3Cycle: 60Service Factor: 1.15-1.20Insulation Class: ?F? NON-Hygroscopic Bearings:Double Row Angular Contact Bearing Life: 950K-1200K hours Enclosure: Totally Enclose Fan-Cooled Motor (TEFC)MOTORSHAFT: Shaft Material: 17-4 Precipitation-Harding (PH), Stainless steel ( S.S), 1150 Condition Shaft Length: 28inches fromend shield face of motor Shaft Diameter: 1.625 inch O.D Minimum Yield Strength: 135K PSI Maximum Yield Strength: 250KPSIPROPELLER: Material: 316 Stainless Steel Balancing: Dynamically to Less than � MIL Maximum DEFLECTOR: Material:304 Stainless Steel, HDG Steel and FRP Exterior Finish: CHEM. Resistant GEL-Coat UV Plate Internal Fill: #3 Quartzite andResin Mixture Minimum FRP Thickness: .375 inch Exterior Color: White Weight: 485-490 LBs POWER MODULE SUPPORTRING: Material: 304 Stainless Steel Dimensions of Flat Rings: .5inch by 3inch by 42 inches O.D. Dimensions of support Rod:1.5 inch by 6 inches Method of construction: Welded AERATOR FLOAT: Method of Construction: Hand Lay Up Material: CDM2415 PROMAT and Chemical Resistant Resin External Finish: Chemical Resistant Gel-Coat UV Stabilized External Color:White Internal Reinforcing (Power Module Support) 3/8 in by 3 inch by 42 inches O.D. Steel Ring Internal Reinforcing (MooringEyes): 3/8inch by 3inches by 9 inches Flat Bar Throat Section Reinforcing: 2inch by 2 inch Encapsulated Ribs Internal Fill:2#DEN. Polyurethane Closed Cell Foam Minimum Thickness: .25inch NON-Stress Areas Mooring Eye Dimension 5/8 inchby 3 inch long Float Diameter: 88 inches Float Thickness: 14 inches Sink Safety Factor: 2.5Volute Thickness: FRP .75 inchThick PERFORMANCE: Pumping Rate: 12,172 GPM02 Transfer Rate: 3.0 LBS/HP/HR/Min Minimum DIA. Of Complete Mix at6 feet Depth: 80 Feet Minimum DIA. Of O2 Dispersion at 6feet Depth: 210 Feet WT. Of Completed Unit: estimated 1700 LBSShipping WT Height of Complete Unit: minimum 54 inches/ max 60 inches. Vendor Provide Aerator Dimensions Chart andmanual Mustbe able to deliver on Weekdays 7am to 3 pm","html":"Waste Water Aerator System MOTOR:HORSEPWER: 14.5-15.5RPM: 1150-1250Full Load AMPS:42/21Voltage 230/460Voltage Phase: 3Cycle: 60Service Factor: 1.15-1.20Insulation Class: ?F? NON-Hygroscopic Bearings:Double Row Angular Contact Bearing Life: 950K-1200K hours Enclosure: Totally Enclose Fan-Cooled Motor (TEFC)MOTORSHAFT: Shaft Material: 17-4 Precipitation-Harding (PH), Stainless steel ( S.S), 1150 Condition Shaft Length: 28inches fromend shield face of motor Shaft Diameter: 1.625 inch O.D Minimum Yield Strength: 135K PSI Maximum Yield Strength: 250KPSIPROPELLER: Material: 316 Stainless Steel Balancing: Dynamically to Less than � MIL Maximum DEFLECTOR: Material:304 Stainless Steel, HDG Steel and FRP Exterior Finish: CHEM. Resistant GEL-Coat UV Plate Internal Fill: #3 Quartzite andResin Mixture Minimum FRP Thickness: .375 inch Exterior Color: White Weight: 485-490 LBs POWER MODULE SUPPORTRING: Material: 304 Stainless Steel Dimensions of Flat Rings: .5inch by 3inch by 42 inches O.D. Dimensions of support Rod:1.5 inch by 6 inches Method of construction: Welded AERATOR FLOAT: Method of Construction: Hand Lay Up Material: CDM2415 PROMAT and Chemical Resistant Resin External Finish: Chemical Resistant Gel-Coat UV Stabilized External Color:White Internal Reinforcing (Power Module Support) 3/8 in by 3 inch by 42 inches O.D. Steel Ring Internal Reinforcing (MooringEyes): 3/8inch by 3inches by 9 inches Flat Bar Throat Section Reinforcing: 2inch by 2 inch Encapsulated Ribs Internal Fill:2#DEN. Polyurethane Closed Cell Foam Minimum Thickness: .25inch NON-Stress Areas Mooring Eye Dimension 5/8 inchby 3 inch long Float Diameter: 88 inches Float Thickness: 14 inches Sink Safety Factor: 2.5Volute Thickness: FRP .75 inchThick PERFORMANCE: Pumping Rate: 12,172 GPM02 Transfer Rate: 3.0 LBS/HP/HR/Min Minimum DIA. Of Complete Mix at6 feet Depth: 80 Feet Minimum DIA. Of O2 Dispersion at 6feet Depth: 210 Feet WT. Of Completed Unit: estimated 1700 LBSShipping WT Height of Complete Unit: minimum 54 inches/ max 60 inches. Vendor Provide Aerator Dimensions Chart andmanual  Mustbe able to deliver on Weekdays 7am to 3 pm","origin":"detail"},"contacts":[{"name":"Juanito Bautista","role":"primary","email":"juanito.d.bautista.civ@army.mil","phone":"8313863428"}],"place_of_performance":{"zip":"93928","street":"USAG Ft Hunter Liggett B319 Lagoon Dr Jolon, CA 93928"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["333998"],"award":null,"attachments":[{"resource_id":"0080f79f141e48c39945041a329451cd","name":"dodprocurementtoolbox.com","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-09-09T19:23:12.820Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false}],"awards":[],"related":[{"key":"W911S227U0192","latest_notice_id":"c63b595eb73347679b26c29f638410f6","title":"Rebar","solicitation_number":"W911S227U0192","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T12:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"332111","psc":"9640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 9640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"W911S227U0124","latest_notice_id":"ec53ce66812b4a5cbedbd1d943848e4c","title":"Dry Suit","solicitation_number":"W911S227U0124","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-23","notices":2,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"314999","psc":"8475","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"FORT IRWIN, CA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W911S227U0191","latest_notice_id":"87d52eddd10d48a9b7897da6d1273621","title":"Mower","solicitation_number":"W911S227U0191","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T19:15:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"333111","psc":"3710","set_aside":"SBA","state":"WI","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"FORT MCCOY, WI","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"W911S227U0193","latest_notice_id":"f0f1d795e38b4700ad8afd0f6f268082","title":"H24 OPTIMIZED TURRETMOUNT (OTM)","solicitation_number":"W911S227U0193","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-25T20:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"332994","psc":"2541","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 2541)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"W911S227U0170","latest_notice_id":"8e384efad4304afa9f8a55c7438674ba","title":"MEDICAL EQUIPMENT AND SUPPLIES","solicitation_number":"W911S227U0170","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-25T06:17:21.102542Z"}],"similar_open":[{"key":"SPMYM227Q0216","latest_notice_id":"68d97a47c2534703969754d96afbe561","title":"CASE HYD AMP 7.250 (SOLE SOURCE)","solicitation_number":"SPMYM227Q0216","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPMYM2","office_name":"DLA MARITIME - PUGET SOUND","naics":"333998","psc":"5360","set_aside":"SDVOSBC","state":"WA","county":"53035","county_name":"Kitsap County","city":"5307695","city_name":"Bremerton","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N0010427QQA05","latest_notice_id":"9a334f65e99d425e81bc86131c127ffa","title":"CARRIER,WEAPONS","solicitation_number":"N0010427QQA05","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-04","notices":3,"due_at":"2026-11-25T20:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333998","psc":"1398","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"D IN THE SCHEDULE. ^^ ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"N0010423QFA30","latest_notice_id":"9ae6913b233e4ced9cbc04f3da89f426","title":"30--CABLE ASSY","solicitation_number":"N0010423QFA30","notice_type":"p","first_type":"o","first_posted":"2026-10-21","last_posted":"2026-10-21","notices":3,"due_at":"2026-11-25T20:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333998","psc":"3040","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 3040)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open_total":110,"indexable":false}