{"canonical":"https://sealedbidder.com/opportunities/w911s225u1525","key":"W911S225U1525","url":"https://sealedbidder.com/opportunities/w911s225u1525","title":"Pyrotech ultra high speed deluge system","solicitation_number":"W911S225U1525","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-19T05:00:00Z","first_posted":"2025-08-11","last_posted":"2025-08-11","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"333998","psc":"4240","set_aside":"SBA","place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 4240)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"107b3e57b6dd4ca4bf202221cb83ee1a","title":"Pyrotech ultra high speed deluge system","solicitation_number":"W911S225U1525","notice_type":"k","base_type":"k","posted":"2025-08-11","posted_at":"2025-08-11T15:03:26.108Z","due_at":"2025-08-19T05:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2026-08-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/107b3e57b6dd4ca4bf202221cb83ee1a/view","enriched":true,"history":[{"index":3,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2025-09-23T13:43:53.330Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"51a6f6f66e51476090afab5cf3b65f8e","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":2,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T16:37:53.739Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a0665283b4bd45a69c98e849206c8ec4","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":1,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T15:03:26.108Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a","solicitation_number":"W911S225U1525"}]},{"notice_id":"a0665283b4bd45a69c98e849206c8ec4","title":"Pyrotech ultra high speed deluge system","solicitation_number":"W911S225U1525","notice_type":"k","base_type":"k","posted":"2025-08-11","posted_at":"2025-08-11T16:37:53.739Z","due_at":"2025-08-19T05:00:00Z","due_date":"2025-08-18","cancelled":false,"archived":true,"archive_date":"2026-08-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a0665283b4bd45a69c98e849206c8ec4/view","enriched":true,"history":[{"index":3,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2025-09-23T13:43:53.330Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"51a6f6f66e51476090afab5cf3b65f8e","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":2,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T16:37:53.739Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a0665283b4bd45a69c98e849206c8ec4","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":1,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T15:03:26.108Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a","solicitation_number":"W911S225U1525"}]}],"latest_notice_id":"a0665283b4bd45a69c98e849206c8ec4","first_type":"k","notices":[{"dates":{"posted":"2025-08-11","posted_at":"2025-08-11T15:03:26.108Z","created_at":"2025-08-11T15:03:26.054Z","modified_at":"2025-09-23T13:43:53.330Z","response_deadline":{"raw":"2025-08-18T23:00:00-06:00","utc":"2025-08-19T05:00:00Z","date":"2025-08-18","time":"23:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/107b3e57b6dd4ca4bf202221cb83ee1a/view"},"naics":{"codes":["922160"],"primary":"922160"},"title":"Pyrotech ultra high speed deluge system","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_id":"500036690","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-11","archive_type":"auto_custom"},"history":[{"index":3,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2025-09-23T13:43:53.330Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"51a6f6f66e51476090afab5cf3b65f8e","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":2,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T16:37:53.739Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a0665283b4bd45a69c98e849206c8ec4","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":1,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T15:03:26.108Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a","solicitation_number":"W911S225U1525"}],"contacts":[{"name":"MIKE FABRY","role":"primary","email":"mike.j.fabry.civ@army.mil","phone":"918-420-6580"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"107b3e57b6dd4ca4bf202221cb83ee1a","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"107b3e57b6dd4ca4bf202221cb83ee1a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-04T03:40:50.588382908Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4f004aabb17c23487975e4ff1b0b3dbc81639b8f1af9e432243ff9d19b21ebf5","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-04T03:40:50.588382908Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Pyrotech Deluge Package Ultra high speed deluge system?\tRAM Qty 1 \tLAM Qty 3 \tRAM BP Qty 1 \tLAM BP Qty 3 \tBrass Solenoid Qty 12 \tCPF-74B Qty 12 \tNozzles Qty 12 \tOr-check Qty 12 \t19 inch Rack Qty 1 \tControl Enclosure Qty 1 \tLaMarche Charger Qty 1 \tBattery Enclosure Qty 1 \tD171-AM Detector Qty 12 \tD171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. \tCustomized Ultra-High Speed Deluge Control Panel design and fabrication\tUltra-High Speed Deluge Control Panel:\tThree part enclosure with viewing door?\tSystem Ready indication (green light)\tSystem Fault indication (amber light)\tSystem lamp test\tAC Loss indication (amber light)\tSupervised electrical manual discharge capability\tAdjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed)\tSupervision of the solenoid wiring for short, open and ground (amber LED for each fault)\tSupervision of the detector wiring for short, open and ground\tGeneral form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.)\tRelays with integral suppression and status LEDs for easier troubleshooting\tIndividually fused zones?\tCustom Graphic Annunciator indicating zone alarm (on multiple zone panels).\tRequired RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests.\tRequired LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.)\tSolenoids\tCPF-74B3 High Speed Deluge Valves\tNozzles (38MA)\tUnitized UV/IR detectors and mounting brackets\tBattery charger\tBattery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge)\tBattery enclosure\tCAD generated drawings (electronic file)\tMechanical manual discharge capability (control panel power is not required to activate this feature)\tElectrical control panel design\tMechanical design assistance\t1 set of system manuals (electronic file)\tInstrumentation and personnel necessary for startup, test and training (includes expenses and up to 3\tdays on site for each system)\tDelivery to your facility\tPyrotech components are Made In USA\t2 year warranty on all Pyrotech equipment\t5 year warranty on Detector equipment","text":"Pyrotech Deluge Package Ultra high speed deluge system? RAM Qty 1 LAM Qty 3 RAM BP Qty 1 LAM BP Qty 3 Brass Solenoid Qty 12 CPF-74B Qty 12 Nozzles Qty 12 Or-check Qty 12 19 inch Rack Qty 1 Control Enclosure Qty 1 LaMarche Charger Qty 1 Battery Enclosure Qty 1 D171-AM Detector Qty 12 D171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. Customized Ultra-High Speed Deluge Control Panel design and fabrication Ultra-High Speed Deluge Control Panel: Three part enclosure with viewing door? System Ready indication (green light) System Fault indication (amber light) System lamp test AC Loss indication (amber light) Supervised electrical manual discharge capability Adjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed) Supervision of the solenoid wiring for short, open and ground (amber LED for each fault) Supervision of the detector wiring for short, open and ground General form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.) Relays with integral suppression and status LEDs for easier troubleshooting Individually fused zones? Custom Graphic Annunciator indicating zone alarm (on multiple zone panels). Required RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests. Required LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.) Solenoids CPF-74B3 High Speed Deluge Valves Nozzles (38MA) Unitized UV/IR detectors and mounting brackets Battery charger Battery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge) Battery enclosure CAD generated drawings (electronic file) Mechanical manual discharge capability (control panel power is not required to activate this feature) Electrical control panel design Mechanical design assistance 1 set of system manuals (electronic file) Instrumentation and personnel necessary for startup, test and training (includes expenses and up to 3 days on site for each system) Delivery to your facility Pyrotech components are Made In USA 2 year warranty on all Pyrotech equipment 5 year warranty on Detector equipment","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U1525","place_of_performance":{"zip":"74501","street":"MCAAPOK"},"product_service_code":"F003"},{"dates":{"posted":"2025-08-11","posted_at":"2025-08-11T16:37:53.739Z","created_at":"2025-08-11T16:37:52.878Z","modified_at":"2025-09-23T13:43:53.330Z","response_deadline":{"raw":"2025-08-18T23:00:00-06:00","utc":"2025-08-19T05:00:00Z","date":"2025-08-18","time":"23:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a0665283b4bd45a69c98e849206c8ec4/view"},"naics":{"codes":["333998"],"primary":"333998"},"title":"Pyrotech ultra high speed deluge system","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_id":"500036690","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-11","archive_type":"auto_custom"},"history":[{"index":3,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":true,"posted_at":"2025-09-23T13:43:53.330Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"51a6f6f66e51476090afab5cf3b65f8e","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":2,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T16:37:53.739Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"a0665283b4bd45a69c98e849206c8ec4","solicitation_number":"W911S225U1525","parent_opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a"},{"index":1,"title":"Pyrotech ultra high speed deluge system","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-11T15:03:26.108Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"107b3e57b6dd4ca4bf202221cb83ee1a","solicitation_number":"W911S225U1525"}],"contacts":[{"name":"MIKE FABRY","role":"primary","email":"mike.j.fabry.civ@army.mil","phone":"918-420-6580"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"a0665283b4bd45a69c98e849206c8ec4","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"107b3e57b6dd4ca4bf202221cb83ee1a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-04T04:06:56.208295609Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"aebddc718b618551c0472e2eff4e7b4dac672e67c59da8cc67c9e94e3fda9b1f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-04T04:06:56.208295609Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Implemented Amendment to change NAICS from 922160 to 33998 and to change PSC code from F003 to 4240Pyrotech Deluge Package Ultra high speed deluge system?\tRAM Qty 1 \tLAM Qty 3 \tRAM BP Qty 1 \tLAM BP Qty 3 \tBrass Solenoid Qty 12 \tCPF-74B Qty 12 \tNozzles Qty 12 \tOr-check Qty 12 \t19 inch Rack Qty 1 \tControl Enclosure Qty 1 \tLaMarche Charger Qty 1 \tBattery Enclosure Qty 1 \tD171-AM Detector Qty 12 \tD171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. \tCustomized Ultra-High Speed Deluge Control Panel design and fabrication\tUltra-High Speed Deluge Control Panel:\tThree part enclosure with viewing door?\tSystem Ready indication (green light)\tSystem Fault indication (amber light)\tSystem lamp test\tAC Loss indication (amber light)\tSupervised electrical manual discharge capability\tAdjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed)\tSupervision of the solenoid wiring for short, open and ground (amber LED for each fault)\tSupervision of the detector wiring for short, open and ground\tGeneral form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.)\tRelays with integral suppression and status LEDs for easier troubleshooting\tIndividually fused zones?\tCustom Graphic Annunciator indicating zone alarm (on multiple zone panels).\tRequired RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests.\tRequired LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.)\tSolenoids\tCPF-74B3 High Speed Deluge Valves\tNozzles (38MA)\tUnitized UV/IR detectors and mounting brackets\tBattery charger\tBattery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge)\tBattery enclosure\tCAD generated drawings (electronic file)\tMechanical manual discharge capability (control panel power is not required to activate this feature)\tElectrical control panel design\tMechanical design assistance\t1 set of system manuals (electronic file)\tInstrumentation and personnel necessary for startup, test and training (includes expenses and up to 3\tdays on site for each system)\tDelivery to your facility\tPyrotech components are Made In USA\t2 year warranty on all Pyrotech equipment\t5 year warranty on Detector equipment","text":"Implemented Amendment to change NAICS from 922160 to 33998 and to change PSC code from F003 to 4240Pyrotech Deluge Package Ultra high speed deluge system? RAM Qty 1 LAM Qty 3 RAM BP Qty 1 LAM BP Qty 3 Brass Solenoid Qty 12 CPF-74B Qty 12 Nozzles Qty 12 Or-check Qty 12 19 inch Rack Qty 1 Control Enclosure Qty 1 LaMarche Charger Qty 1 Battery Enclosure Qty 1 D171-AM Detector Qty 12 D171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. Customized Ultra-High Speed Deluge Control Panel design and fabrication Ultra-High Speed Deluge Control Panel: Three part enclosure with viewing door? System Ready indication (green light) System Fault indication (amber light) System lamp test AC Loss indication (amber light) Supervised electrical manual discharge capability Adjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed) Supervision of the solenoid wiring for short, open and ground (amber LED for each fault) Supervision of the detector wiring for short, open and ground General form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.) Relays with integral suppression and status LEDs for easier troubleshooting Individually fused zones? Custom Graphic Annunciator indicating zone alarm (on multiple zone panels). Required RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests. Required LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.) Solenoids CPF-74B3 High Speed Deluge Valves Nozzles (38MA) Unitized UV/IR detectors and mounting brackets Battery charger Battery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge) Battery enclosure CAD generated drawings (electronic file) Mechanical manual discharge capability (control panel power is not required to activate this feature) Electrical control panel design Mechanical design assistance 1 set of system manuals (electronic file) Instrumentation and personnel necessary for startup, test and training (includes expenses and up to 3 days on site for each system) Delivery to your facility Pyrotech components are Made In USA 2 year warranty on all Pyrotech equipment 5 year warranty on Detector equipment","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U1525","place_of_performance":{"zip":"74501","street":"MCAAPOK"},"product_service_code":"4240"}],"due_at":"2025-08-19T05:00:00Z","due_date":"2025-08-18","closes_at":"2025-08-19T05:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 4240)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-04T05:14:00.353426Z","principal_notice_id":"a0665283b4bd45a69c98e849206c8ec4","description":{"text":"Implemented Amendment to change NAICS from 922160 to 33998 and to change PSC code from F003 to 4240Pyrotech Deluge Package Ultra high speed deluge system? RAM Qty 1 LAM Qty 3 RAM BP Qty 1 LAM BP Qty 3 Brass Solenoid Qty 12 CPF-74B Qty 12 Nozzles Qty 12 Or-check Qty 12 19 inch Rack Qty 1 Control Enclosure Qty 1 LaMarche Charger Qty 1 Battery Enclosure Qty 1 D171-AM Detector Qty 12 D171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. Customized Ultra-High Speed Deluge Control Panel design and fabrication Ultra-High Speed Deluge Control Panel: Three part enclosure with viewing door? System Ready indication (green light) System Fault indication (amber light) System lamp test AC Loss indication (amber light) Supervised electrical manual discharge capability Adjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed) Supervision of the solenoid wiring for short, open and ground (amber LED for each fault) Supervision of the detector wiring for short, open and ground General form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.) Relays with integral suppression and status LEDs for easier troubleshooting Individually fused zones? Custom Graphic Annunciator indicating zone alarm (on multiple zone panels). Required RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests. Required LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.) Solenoids CPF-74B3 High Speed Deluge Valves Nozzles (38MA) Unitized UV/IR detectors and mounting brackets Battery charger Battery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge) Battery enclosure CAD generated drawings (electronic file) Mechanical manual discharge capability (control panel power is not required to activate this feature) Electrical control panel design Mechanical design assistance 1 set of system manuals (electronic file) Instrumentation and personnel necessary for startup, test and training (includes expenses and up to 3 days on site for each system) Delivery to your facility Pyrotech components are Made In USA 2 year warranty on all Pyrotech equipment 5 year warranty on Detector equipment","html":"Implemented Amendment to change NAICS from 922160 to 33998 and to change PSC code from F003 to 4240Pyrotech Deluge Package Ultra high speed deluge system?\tRAM Qty 1 \tLAM Qty 3 \tRAM BP Qty 1 \tLAM BP Qty 3 \tBrass Solenoid Qty 12 \tCPF-74B Qty 12 \tNozzles Qty 12 \tOr-check Qty 12 \t19 inch Rack Qty 1 \tControl Enclosure Qty 1 \tLaMarche Charger Qty 1 \tBattery Enclosure Qty 1 \tD171-AM Detector Qty 12 \tD171 Detector Mount Qty 12 Includes Pyrotech UHSD system components with the addition of a pre-wired control panel and power system engineered by Pyrotech plus an on-site visit by a Pyrotech technician. Visit includes commissioning (start-up, testing and training) and up to 3 days on site. \tCustomized Ultra-High Speed Deluge Control Panel design and fabrication\tUltra-High Speed Deluge Control Panel:\tThree part enclosure with viewing door?\tSystem Ready indication (green light)\tSystem Fault indication (amber light)\tSystem lamp test\tAC Loss indication (amber light)\tSupervised electrical manual discharge capability\tAdjustable auto reset (Automatic reset was initially developed to meet EPA requirements regarding contaminated water. The integral feature allows water to flow for a predetermined time from 0 to 90 seconds and automatically shut off. If, at any time in the predetermined time cycle, an alarm occurs, the RAM and any corresponding LAMs will actuate solenoids to provide deluge coverage. This feature can be field adjusted or bypassed)\tSupervision of the solenoid wiring for short, open and ground (amber LED for each fault)\tSupervision of the detector wiring for short, open and ground\tGeneral form C alarm and fault contacts (i.e. external devices, machine shutdown, etc.)\tRelays with integral suppression and status LEDs for easier troubleshooting\tIndividually fused zones?\tCustom Graphic Annunciator indicating zone alarm (on multiple zone panels).\tRequired RAMs (Response Acceleration Modules) The RAM supervises solenoid and electrical manual pull circuitry (if electrical manual pulls are used) for short, open and ground faults. The RAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. The RAM has a key switch to individually inhibit each zone if desired. The RAM has the required internal circuitry to provide automatic reset. The RAM has an integral test jack for system reaction time tests.\tRequired LAMs (Low cost Acceleration Module) The LAM is a slave module to the RAM. The LAM supervises solenoid circuitry for short, open and ground faults. It controls up to four solenoids. The LAM provides the required high speed, high voltage pulse to achieve the required system reaction speed. (This module not required for this application.)\tSolenoids\tCPF-74B3 High Speed Deluge Valves\tNozzles (38MA)\tUnitized UV/IR detectors and mounting brackets\tBattery charger\tBattery backup (sealed, lead-acid with gelled electrolyte, 8 hours backup / 16 hour recharge)\tBattery enclosure\tCAD generated drawings (electronic file)\tMechanical manual discharge capability (control panel power is not required to activate this feature)\tElectrical control panel design\tMechanical design assistance\t1 set of system manuals (electronic file)\tInstrumentation and personnel necessary for startup, test and training (includes expenses and up to 3\tdays on site for each system)\tDelivery to your facility\tPyrotech components are Made In USA\t2 year warranty on all Pyrotech equipment\t5 year warranty on Detector equipment","origin":"detail"},"contacts":[{"name":"MIKE FABRY","role":"primary","email":"mike.j.fabry.civ@army.mil","phone":"918-420-6580"}],"place_of_performance":{"zip":"74501","street":"MCAAPOK"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["333998"],"award":null,"attachments":[{"resource_id":"bb7a2838e8304d1db4eaa4e4f4808531","name":"dodprocurementtoolbox.com","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-08-11T15:03:26.108Z","export_controlled":false,"sha256":null,"url":"https://dodprocurementtoolbox.com/","mirrored":false}],"awards":[],"related":[{"key":"W911S227U0195","latest_notice_id":"97b456f6ebf8446a8eaab01f982a6497","title":"Fiberboard filler sheet, top/bottom and side","solicitation_number":"W911S227U0195","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-11-26T11:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T11:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"322211","psc":"8135","set_aside":"SBA","state":"AR","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"PINE BLUFF ARSENAL, 504TH ST, BLDG 53-990, CENTRAL RECEIVING PT., PINE BLUFF, AR 71602","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W911S227U0167","latest_notice_id":"329dd9aaa84845dbba2130418ce2ad17","title":"Incubator Shaker","solicitation_number":"W911S227U0167","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0166","latest_notice_id":"55af918bb27d41c29cf8b4f1c1cd01e9","title":"iWorx","solicitation_number":"W911S227U0166","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0067","latest_notice_id":"27cb39c606874abaa0a99e4b30bf374c","title":"Dictionaries","solicitation_number":"W911S227U0067","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"323117","psc":"7610","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"SPE4A727R0166","latest_notice_id":"3a0f534658ab461f9e2b86fd9d6da5d5","title":"LEVEL ASSEMBLY, AIRC","solicitation_number":"SPE4A727R0166","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A7","office_name":"DLA AVIATION","naics":"333998","psc":"3655","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 3655)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N0010427QBB78","latest_notice_id":"904dbfab5c134f4883c2d2f014af543f","title":"SEAL RING,NUCLEAR C","solicitation_number":"N0010427QBB78","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"333998","psc":"4470","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4470)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0038327QMA20","latest_notice_id":"c09579a6e1ac4fc5be21c69547311fe6","title":"PIVOT,SUPPORT","solicitation_number":"N0038327QMA20","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00383","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT","naics":"333998","psc":"99","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 99)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":115,"indexable":false}