MICROWAVE THERAPY SYSTEM

W81K0426QA059

Department of the Army, W40M USA Hca. Electromedical and Electrotherapeutic Apparatus Manufacturing.

Response deadline

May 21, 2026 at 10:00 AM EDT

Closed 188 days ago. Posted May 12, 2026. Scheduled to archive June 5, 2026.

Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities

This one closed in 2026

12 like it are open now in electromedical and electrotherapeutic apparatus manufacturing

All 12 open in electromedical and electrotherapeutic apparatus manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of May 12, 2026. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

This is a Request for Information (RFI) – Sought Notice Only. This notice is issued solely for information and planning purposes only.
 

1. The US Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder; not responding to this notice does not preclude participation in any further RFQ; IFB or RFP if issued.
 

2. The associated North American Industry Classification System (NAICS) is 334510. The business size standard is 750 Employees. All contractors doing business with the Department of Defense shall be registered and approved through the System for Award Management (SAM). This is the Official U.S. Government system that consolidates the capabilities of CCR/FedReg, and EPLS. There is no fee to register for this site. Entities may register at no cost directly from this page. The proposed performance start date will be on or about 1 July 2026. The Solicitation number is W81K0426QA043.
 

3. Note – Prior to award your company shall reflect the NAICS Code 334510 identified on your SAM. If your company is interested in competing on this project, and have services, please submit the following documentation no later than  21 May 2026, 10:00 AM EST, to Cynthia A. Richardson-Rhone and Jason Holck at cynthia.a.richardson-rhone.civ@health.mil. 


Your email response shall provide the following:

Can you provide the following:

General System Description

The Intelli Blate Microwave Ablation System is a software-controlled microwave therapy delivery platform intended for the coagulation (ablation) of soft tissues. The system utilizes microwave energy to produce controlled, spherical ablation zones and features integrated cooling, real-time temperature monitoring, and advanced probe placement functions.

Generator (Console) Specifications

  • Operating Frequency  2.45 GHz ± 50 MHz
  • Ablation Channels       Must support at least two (2) independent ablation channels, allowing for single-probe, dual-independent, or dual-linked probe operations
  • Output Power  Single Channel: 0 to 90 Watts. Dual Channel: 0 to 80 Watts per channel (up to 160 Watts linked)
  • Power Adjustments     Output power must be adjustable in 5-Watt increments.
  • Safety Shut off            Must feature an automatic system shutdown if probe temperatures or reflected power exceed established safety limits
  • Dimensions & Weight Console alone must weigh no more than 40 lbs. (approx. 38 lbs.) for portability and mount securely to a customized mobile cart

User Interface & Display

  • Monitor            15.6-inch foldable, high-resolution color touchscreen
  • Ergonomics     Screen must be capable of swiveling 180 degrees (CW/CCW) to allow visibility from any operating position. Must be fully operable with gloved hands or through a sterile drape
  • Visual Feedback         Interface must provide real-time tracking of time, tip power, reflected energy (power), and multi-point temperature data

Integrated Cooling System

  • Pump Mechanism       Must feature two (2) fully integrated peristaltic pumps built directly into the console (one for each ablation channel)
  • Coolant Compatibility Must be compatible with standard, user-supplied sterile water or 0.9% saline (1000 mL bags or greater)
  • Cassette Loading        Must utilize a drop-in, integrated fluid cassette system to streamline coolant delivery and prevent setup errors

Probe Assembly Characteristics (Ximitry Probes)

  • Antenna Profile           13.5 Gauge (2.3 mm diameter) fiberglass shaft with a ceramic trocar tip
  • Available Lengths       Must be available in at least three lengths: 15 cm, 20 cm, and 27 cm
  • Integrated Temperature Sensing        Probe must contain at least three (3) integrated thermocouples along the shaft and two (2) internal temperature sensors within the handle for continuous, real-time thermal feedback
  • Cable Management    Must utilize a single-cable bundle that integrates both the RF power cable and the coolant tubing (supply and return lines) into one cord
  • Visual Indicators         Probe handles must include integrated LED indicators to visually signal when microwave energy is actively being delivered

Advanced Clinical Workflow Features

  • Needle Lock    Must include a feature that delivers a short, calculated burst of microwave energy to secure the radiating section of the probe to the tissue, mitigating accidental probe migration during setup or intra-procedural imaging
  • Tract Ablation  Must include a specific track ablation/cauterization mode to safely ablate the tissue along the insertion tract (4-10 mm) during probe retraction to prevent bleeding and tumor seeding.
  • External Temperature Monitoring       System must support the connection of up to two (2) remote/external Temperature Sensor Probes to monitor collateral tissue temperatures independently from the ablation probes
  • System Integration      Must be capable of integrating with advanced 3D planning and laser guidance software (e.g., my Ablation Guide, my Needle Companion) and support laser alignment discs on the probe handles.

Please ensure to address the below:


Name of Company
Point of contact
Phone number
Email address
Identify Your Small Business Socio-Economic Group
DUNS number and CAGE Code


4. This requirement No telephonic inquiries will be responded to. A solicitation will be posted within 2-3 weeks www.Sam.gov.

               

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. May 12, 2026

    Sources sought

    Due May 21, 2026 at 10:00 AM EDT. SAM.gov, notice e67e29337ca14efd80353b6ba303b583

    1 revision on SAM
    • May 12, 2026: publish, sources sought

Points of contact